• 제목/요약/키워드: resistance detection

검색결과 555건 처리시간 0.041초

경북북부지역 젖소 유방염 우유 및 각종 동물로부터 분리한 staphylococcus aureus의 항균제 내성과 MRSA검출에 관한 연구 (Study on antimicrobial resistance of staphylococcus aureus isolated from bovine mastitic milk and several animals in kyongbuk northern province and detection of MRSA from the isolates of S aureus)

  • 김신;오유미;김상윤;우용구;권헌일
    • 한국동물위생학회지
    • /
    • 제23권2호
    • /
    • pp.153-163
    • /
    • 2000
  • This study was carried out the antimicrobial resistance of staphylococcus aureus isolated from bovine mastitic milk, chickens, korean native cattle, korean native goats, pigs, dog and mice in northern area of kyongbuk. The result were summarised as follows ; A total of 149 S aureus were isolated from bovine mastitic milk, chickens, korean native cattle, korean native goats, pigs, dog and mice. In 80 isolates of S aureus from bovine mastitic milk, 60% of isolates revealed resistance to penicillin and ampicillin, 19% to gentamicin, 6% to tetracycline. In 36 isolates of S aureus from chickens, 72% of isolates revealed resistance to tetracycline, 58% to penicillin and ampicillin, 42% to streptomycin, 31% to lincomycin, 25% to norfloxacin, 22% to gentamicin. In 17 isolates of S aureus from korean native cattle, 100% of isolates revealed resistance to penicillin and ampicillin, 88% to lincomycin, 76% to tetracycline. 2 MRSA were isolated from the isolates of S aureus from bovine mastitic milk and revealed multi-drug resistance.

  • PDF

Impedance Parameter Variations at Intravenous (IV) Infiltration Using Bioelectrical Impedance: A Pilot Study

  • Kim, Jaehyung;Lee, Mansup;Baik, Seungwan;Kim, Gunho;Hwang, Youngjun;Jeon, Gyerok
    • 한국멀티미디어학회논문지
    • /
    • 제20권10호
    • /
    • pp.1678-1688
    • /
    • 2017
  • Infiltration is one of detrimental problems occurring in nursing or medical settings. Early detection of infiltration is essential to minimize the risk of injury from infiltration. To perform a preliminary study on the point of care and automated infiltration detection system, bioelectrical impedance was investigated using bioelectrical impedance analyzer. We would like to report experimental results that allow impedance parameters to effectively distinguish infiltration. Electrodes were attached to both sides of the transparent dressing on the fusion site where IV solution was being infused. Then, impedance parameters before and after infiltration were measured as a function of time and frequency. The experimental results are as follows. After infiltration was intentionally induced by puncturing the vein wall with a needle, the resistance gradually decreased with time. That is, when an alternating current having a frequency of 20 kHz was applied to the electrodes, the resistance gradually decreased with time, reflecting the accumulation of IV solution in the extracellular fluid since the current could not pass through the cell membrane. Impedance parameters and equivalent circuit model for human cell were used to examine the mechanism of current flow before and after infiltration, which could be used for early detection of infiltration.

메티실린 내성 황색 포도상 구균에서 mecA, femA 유전자의 임상적 의의 (Detection of Methicillin-Resistant Staphylococcus aureus by In Vitro Enzymatic Amplification of MecA and FemA Gene)

  • 박정은;김택선;박수성;김은령;김일수;안일영;김영진;김재종;강성옥;박한오
    • Pediatric Infection and Vaccine
    • /
    • 제3권2호
    • /
    • pp.133-138
    • /
    • 1996
  • Purpose : In the treatment of MRSA infection, rapid detection of MRSA is extremely important. The mecA gene codes the new drug resistant polypeptides called PBP2' which mediates the clinically relevant resistance to all beta-lactam antibiotics. The identical mecA gene has been found in coagulase-negative staphylococcus with the methicillin-resistant phenotype. On the other hand, the femA gene was absent from coagulase negative staphylococcus strains with the methicillin resistant phenotype. This study is aimed at early detection and definite diagnosis of MRSA. Methods : A total of 24 MRSA strains were studied. All strains were tested for antimicrobial susceptibility and purified DNA. We amplified both mecA and femA genes by PCR in 24 strains. Results : In MRSA all the 16 strains (100%) carried femA gene and 11 strains (68.7%) carried mecA gene. In contrast, in methicillin sensitive staphylococcus all the 8 strains (100%) carried femA and only 3 strains (37.5%) were detected mecA. Conclusions : As results, there are difference in the phenotype and genotype of methicillin resistance by PCR of mecA and femA. Such disparities between methicillin resistance and the presence of mecA gene suggest the presence of control gene of the mecA.

  • PDF

Application of Loop-Mediated Isothermal Amplification (LAMP) Assay to Rapid Detection of Methicillin-Resistant Staphylococcus aureus from Blood Cultures

  • Baek, Yun-Hee;Jo, Mi-Young;Song, Min-Suk;Hong, Seung-Bok;Shin, Kyeong-Seob
    • 대한의생명과학회지
    • /
    • 제25권1호
    • /
    • pp.75-82
    • /
    • 2019
  • We developed the multiplex LAMP assay using 16S rRNA, femA and mecA genes for direct detection of the methicillin resistance in Staphylococci from positive blood culture. To simultaneously recognize Staphylococci genus, S. aureus and methicillin resistance, three sets of six primers for 16S rRNA, femA and mecA were designed, respectively. The performance of LAMP assay was affirmed using VITEK system for the phenotypic methods of identification and for oxacillin and cefoxitin antimicrobial susceptibility. The optimal condition for LAMP assay was obtained under $64^{\circ}C$ for 50 min. The detection limit was determined to be of 20 copies and CFU/reaction ($10^4CFU/mL$). For clinical application of comparison with phenotypic methods, the sensitivity and specificity of the LAMP with femA gene for detecting S. aureus was 95.31% and 100%, respectively. The sensitivity and specificity of the LAMP with mecA gene for detecting methicillin resistance was 98.46% and 100%, respectively. The multiplex LAMP assay with femA and mecA gene successfully detected all of MRSA (38 isolates) isolates from 103 Staphylococci in blood cultures. The LAMP assay developed in this study is sensitive, specific, and of excellent agreement with the phenotypic methods.

A LAMP-SNP Assay Detecting C580Y Mutation in Pfkelch13 Gene from Clinically Dried Blood Spot Samples

  • Khammanee, Thunchanok;Sawangjaroen, Nongyao;Buncherd, Hansuk;Tun, Aung Win;Thanapongpichat, Supinya
    • Parasites, Hosts and Diseases
    • /
    • 제59권1호
    • /
    • pp.15-22
    • /
    • 2021
  • Artemisinin resistance (ART) has been confirmed in Greater Mekong Sub-region countries. Currently, C580Y mutation on Pfkelch13 gene is known as the molecular marker for the detection of ART. Rapid and accurate detection of ART in field study is essential to guide malaria containment and elimination interventions. A simple method for collection of malaria-infected blood is to spot the blood on filter paper and is fast and easy for transportation and storage in the field study. This study aims to evaluate LAMP-SNP assay for C580Y mutation detection by introducing an extra mismatched nucleotide at the 3' end of the FIP primer. The LAMP-SNP assay was performed in a water bath held at a temperature of 56℃ for 45 min. LAMP-SNP products were interpreted by both gel-electrophoresis and HNB-visualized changes in color. The method was then tested with 120 P. falciparum DNA from dried blood spot samples. In comparing the LAMP-SNP assay results with those from DNA sequencing of the clinical samples, the 2 results fully agreed to detect C580Y. The sensitivity and specificity of the LAMP-SNP assay showed 100%. There were no cross-reactions with other Plasmodium species and other Pfkelch13 mutations. The LAMP-SNP assay performed in this study was rapid, reliable, and useful in detecting artemisinin resistance in the field study.

High-level mupirocin resistance in Gram-positive bacteria isolated from diseased companion animals

  • Sum, Samuth;Park, Hee-Myung;Oh, Jae Young
    • Journal of Veterinary Science
    • /
    • 제21권3호
    • /
    • pp.40.1-40.8
    • /
    • 2020
  • The purpose of this study was to investigate the high-level mupirocin resistance (HLMR) in Gram-positive bacteria isolated from companion animals. A total of 931 clinical specimens were collected from diseased pets. The detection of mupirocin-resistant bacteria and plasmid-mediated mupirocin resistance genes were evaluated by antimicrobial susceptibility tests, polymerase chain reactions, and sequencing analysis. Four-hundred and six (43.6%) bacteria were isolated and 17 (4.2%), including 14 staphylococci and 3 Corynebacterium were high-level mupirocin-resistant (MICs, ≥ 1,024 ug/mL) harboring mupA. Six staphylococci of HLMR strains had plasmid-mediated mupA-IS257 flanking regions. The results show that HLMR bacteria could spread in veterinary medicine in the near future.

호퍼스케일용 고주파 저항방식의 습도센서 및 컨트롤러 개발 (A Development of the Humidity Sensor and Controller Using High Frequency Resistance Method for Hopper-Scale)

  • 서양오;이창근;이동철;홍연찬
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(5)
    • /
    • pp.163-166
    • /
    • 2000
  • This paper describes the principle of humidity sensor using high frequency resistance method for Hopper-Scale that is used in RPC(Rice processing Complex) which is spreaded out in domestic, and we also understand the principle and specificity of controller and humidity sensor. After artworking the humidity sensor and controller circuit, we measure the humidity of the designed system. In this progress, we suggested substitute parts which are easy to get in domestic and also we could propose correct method of humidity detection.

  • PDF

Increased Sensitivity of Carbon Nanotube Sensors by Forming Rigid CNT/metal Electrode

  • 박대현;전동렬
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.348-348
    • /
    • 2011
  • Carbon nanotube (CNT) field effect transistors and sensors use CNT as a current channel, of which the resistance varies with the gate voltage or upon molecule adsorption. Since the performance of CNT devices depends very much on the CNT/metal contact resistance, the CNT/electrode contact must be stable and the contact resistance must be small. Depending on the geometry of CNT/electrode contact, it can be categorized into the end-contact, embedded-contact (top-contact), and side-contact (bottom-contact). Because of difficulties in the sample preparation, the end-contact CNT device is seldom practiced. The embedded-contact in which CNT is embedded inside the electrode is desirable due to its rigidness and the low contact resistance. Fabrication of this structure is complicated, however, because each CNT has to be located under a high-resolution microscope and then the electrode is patterned by electron beam lithography. The side-contact is done by depositing CNT electrophoretically or by precipitating on the patterned electrode. Although this contact is fragile and the contact resistance is relatively high, the side-contact by far has been widely practiced because of its simple fabrication process. Here we introduce a simple method to embed CNT inside the electrode while taking advantage of the bottom-contact process. The idea is to utilize a eutectic material as an electrode, which melts at low temperature so that CNT is not damaged while annealing to melt the electrode to embed CNT. The lowering of CNT/Au contact resistance upon annealing at mild temperature has been reported, but the electrode in these studies did not melt and CNT laid on the surface of electrode even after annealing. In our experiment, we used a eutectic Au/Al film that melts at 250$^{\circ}C$. After depositing CNT on the electrode made of an Au/Al thin film, we annealed the sample at 250$^{\circ}C$ in air to induce eutectic melting. As a result, Au-Al alloy grains formed, under which the CNT was embedded to produce a rigid and low resistance contact. The embedded CNT contact was as strong as to tolerate the ultrasonic agitation for 90 s and the current-voltage measurement indicated that the contact resistance was lowered by a factor of 4. By performing standard fabrication process on this CNT-deposited substrate to add another pair of electrodes bridged by CNT in perpendicular direction, we could fabricate a CNT cross junction. Finally, we could conclude that the eutectic alloy electrode is valid for CNT sensors by examine the detection of Au ion which is spontaneously reduced to CNT surface. The device sustatined strong washing process and maintained its detection ability.

  • PDF