• 제목/요약/키워드: resin acid

검색결과 775건 처리시간 0.024초

RESEARCH PAPERS : CHARACTERIZATION OF DISSOLVED ORGANIC MATTER IN A SHALLOW EUTROPHIC LAKE AND INFLOWING WATERS

  • 김용환;이선화
    • Environmental Engineering Research
    • /
    • 제7권2호
    • /
    • pp.93-101
    • /
    • 2002
  • The seasonal patterns of dissolved organic matter (DOM) in Lake Kasumigaura, a shallow, eutrophic lake, and serveral DOM sources in its catchment area were investigated. DOM was fractionated using three resin adsorbents into classes: aquatic humic substances (AHS=humic acid+fulvic acid), hydrophobic neutrals (HoN), hydrophilic acids (HiA), bases (BaS) and hydrophilic neutrals (HiN). The DOM produced significantly different fraction distributions depending on the origin of sample. AHS and HiA prevailed over AHS in the lake while AHS and HiA existed at almost the same concentration levels in the rivers. AHS seems to be a more dominant component in rever water than lake water. The dominance of organic acids was also observed in the DOM sources: forest stream (FS), plowed field percolate (PFP), domestic sewage (DS) and sewage treatment plant effluent (STPE).

Metal Ion Selectivity of Surface Templated Resins Carrying Phosphate Groups

  • Murata, Masaharu;Maeda, Mizuo;Takagi, Makoto
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.529-534
    • /
    • 1995
  • The metal ion selective resins were prepared by surface template polymerization using monooleyl phosphoric acid (1), oleyl methyl phosphoric acid (2) or oleyl ethyl phosphoric acid (3) as an amphiphilic host surfactant. The $Cu^{2+}$-imprinted resins prepared in the presence of $Cu^{2+}$ adsorbed $Cu^{2+}$ much more effectively than did their reference resins. On the other hand, the $Cu^{2+}$-imprinted resins showed much less binding ability to $Zn^{2+}$. The template-dependent selectivity should be ascribed to a favorable placement of the surface-anchored metallophilic groups for multidentate coordination to specific metal ion.

  • PDF

충전재 변화에 따른 PET 재활용 폴리머 콘크리트의 황산 부식에 관한 특성 (Characteristics of Sulfuric acid corrosion of Recycled PET Polymer Concrete with Different Filler)

  • 조병완;구자갑;박종화;박승국
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.719-722
    • /
    • 2004
  • Resins using recycled PET offer the possibility of a lower source cost of materials for making useful polymer concrete products. The purposed of this paper is to form a part of reducing the damage of sulfuric acid, through investigating recycled PET polymer concrete, . immersed at sulfuric acid solution for 84 days. Recycled PET PC is excellent chemical resistance, resulting in the role of unsaturated polyester resin which consists of polymer chain structure accomplishes bond of aggregates and filler strongly. Also, Recycled PET PC, used fly-ash as filler, is stronger resistance of sulfuric acid corrosion than $CaCO_3$, because it is composed of $SiO_2$ and very strong glassy crystal structure. Therefore, Recycled PET PC, used fly-ash as filler, is available under corrosion circumstances like sewer pipe or waste disposal plant.

  • PDF

콘크리트-폴리머 복합재료 개발(II) -폴리머(레진) 콘크리트의 물성- (Development of Concrete-Polymer Composite(II) -Physical Properties of Polymer(Resin) Concrete-)

  • 황의환;황택성;길덕수
    • 공업화학
    • /
    • 제10권7호
    • /
    • pp.1066-1072
    • /
    • 1999
  • 고기능성 건설재료로 활용하기 위하여 불포화폴리에스테르수지를 사용한 폴리머 콘크리트의 물성에 대하여 조사하였다. 탄산칼슘(충전제)의 첨가량(5~20 wt %)과 세골재의 첨가량(10~50 wt %)에 따라 다양한 배합의 공시체를 제작하여 압축 및 휨강도, 흡수시험, 내열수성시험, 내산성시험, 세공분포측정 및 SEM에 의한 미세조직 관찰등을 실시하였다. 그 결과 폴리머 콘크리트의 압축강도와 휨강도는 시멘트 콘크리트보다 4배 정도 향상되었고, 흡수율은 1/100로 감소되었으며, 내산성시험에 의한 중량감소율은 1/27로 현저히 감소되었다. 내열수성시험후에 측정한 폴리머 콘크리트의 압축 및 휨강도는 모두 내열수성시험전에 측정한 강도에 비하여 67%, 47%로 각각 감소되었으며 폴리머결합재의 분해에 의하여 세공량과 세공율은 크게 증가되었다.

  • PDF

The effect of silane applied to glass ceramics on surface structure and bonding strength at different temperatures

  • Yavuz, Tevfik;Eraslan, Oguz
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권2호
    • /
    • pp.75-84
    • /
    • 2016
  • PURPOSE. To evaluate the effect of various surface treatments on the surface structure and shear bond strength (SBS) of different ceramics. MATERIALS AND METHODS. 288 specimens (lithium-disilicate, leucite-reinforced, and glass infiltrated zirconia) were first divided into two groups according to the resin cement used, and were later divided into four groups according to the given surface treatments: G1 (hydrofluoric acid (HF)+silane), G2 (silane alone-no heat-treatment), G3 (silane alone-then dried with $60^{\circ}C$ heat-treatment), and G4 (silane alonethen dried with $100^{\circ}C$ heat-treatment). Two different adhesive luting systems were applied onto the ceramic discs in all groups. SBS (in MPa) was calculated from the failure load per bonded area (in $N/mm^2$). Subsequently, one specimen from each group was prepared for SEM evaluation of the separated-resin-ceramic interface. RESULTS. SBS values of G1 were significantly higher than those of the other groups in the lithium disilicate ceramic and leucite reinforced ceramic, and the SBS values of G4 and G1 were significantly higher than those of G2 and G3 in glass infiltrated zirconia. The three-way ANOVA revealed that the SBS values were significantly affected by the type of resin cement (P<.001). FIN ceramics had the highest rate of cohesive failure on the ceramic surfaces than other ceramic groups. AFM images showed that the surface treatment groups exhibited similar topographies, except the group treated with HF. CONCLUSION. The heat treatment was not sufficient to achieve high SBS values as compared with HF acid etching. The surface topography of ceramics was affected by surface treatments.

Group Separation of Water-soluble Organic Carbon Fractions in Ash Samples from a Coal Combustion Boiler

  • Park, Seung-Shik;Jeong, Jae-Uk;Cho, Sung-Yong
    • Asian Journal of Atmospheric Environment
    • /
    • 제6권1호
    • /
    • pp.67-72
    • /
    • 2012
  • The chemical characterization of water-soluble organic carbon in ash emitted from a coal combustion boiler has not been reported yet. A total of 5 ash samples were collected from the outlet of an electrostatic precipitator in a commercial 500 MW coal-fired power plant, with their chemical characteristics investigated. XAD7HP resin was used to quantify the hydrophilic and hydrophobic water-soluble organic carbons (WSOC), which are the fractions of WSOC that penetrate and remain on the resin column, respectively. Calibration results indicate that the hydrophilic fraction includes aliphatic dicarboxylic acids and carbonyls (<4 carbons), amines and saccharides, while the hydrophobic fraction includes aliphatic dicarboxylic acids (>4-5 carbons), phenols, aromatic acids, cyclic acid and humic acid. The average mass of the WSOC in the ash samples was found to depend on the bituminous coal type being burned, and ranged from 163 to 259 ${\mu}g$ C/g of ash, which corresponds to 59-96 mg C of WSOC/kg of coal combusted. The WSOC mass accounted for 0.02-0.03 wt% of the used ash sample mass. Based on the flow rate of flue gas produced from the combustion of the blended coals in the 500 MW coal combustion boiler, it was estimated that the WSOC particles were emitted to the atmosphere at flow rates of 4.6-7.2 g C/hr. The results also indicated that the hydrophilic WSOC fraction in the coal burned accounted for 64-82% of the total WSOC, which was 2-4 times greater than the mass of the hydrophobic WSOC fraction.

XAD 수지에 의한 친수성 및 소수성 수용성 유기탄소의 특성조사 (Study on Characterization of Hydrophilic and Hydrophobic Fractions of Water-soluble Organic Carbon with a XAD Resin)

  • 정재욱;김자현;박승식;문광주;이석조
    • 한국대기환경학회지
    • /
    • 제27권3호
    • /
    • pp.337-346
    • /
    • 2011
  • 24-hr integrated measurements of water-soluble organic carbon (WSOC) in PM2.5 were made between May 5 and September 25, 2010, on a six-day interval basis, at the Metropolitan Area Air Pollution Monitoring Supersite. A macro-porous XAD7HP resin was used to separate hydrophilic and hydrophobic WSOC. Compounds that penetrate the XAD7HP column are referred to hydrophilic WSOC, while those retained by the column are defined as hydrophobic WSOC. Laboratory calibrations using organic standards suggest that hydrophilic WSOC includes lowmolecular aliphatic dicarboxylic acids and carbonyls with less than 4 or 5 carbons, amines, and saccharides. While the hydrophobic WSOC is composed of compounds of aliphatic dicarboxylic acids with carbon numbers larger than 4~5, phenols, aromatic acids, cyclic acid, and humic-like Suwannee River fulvic acid. Over the entire study period, total WSOC accounted for on average 48% of OC, ranging from 32 to 65%, and hydrophilic WSOC accounted for on average 30.5% (9.3~66.7%) of the total WSOC. Based on the previous results, our measurement result suggests that significant amounts of hydrophobic WSOC during the study period were probably from primary combustion sources. However, on June 9 when 1-hr highest ozone concentration of 130 ppb was observed, WSOC to OC was 0.61, driven by increases in the hydrophilic WSOC. This result also suggests that processes, such as secondary organic aerosol formation, produce significant levels of hydrophilic WSOC compounds that add substantially to the fine particle fraction of the organic aerosol.

폐수중 암모늄 이온 회수를 위한 불균질 양이온교환막의 제조 및 특성 (Preparation and Properties of Heterogeneous Cation Exchange Membrane for Recovery of Ammonium Ion from Waste Water)

  • 정부영;송상헌;백기완;조인희;황택성
    • 폴리머
    • /
    • 제30권6호
    • /
    • pp.486-491
    • /
    • 2006
  • 본 연구에서는 폐수중에 함유된 암모늄 이온을 전기투석 방법으로 회수하기 위하여 불균질 이온교환막을 압축성형 방법으로 제조하였다. 설폰화 양이온교환수지의 설폰화도는 설폰화제인 chlorosulfonic acid의 함량이 증가함에 따라 증가하였고, 최대 설폰화율은 10 vol%일때 3.32 meq/g이었다. 불균질 이온교환막의 인장강도와 신장률은 이온교환수지의 함량이 증가함에 따라 각각 감소하였으며 인장강도는 LLDPE 막이 가장 높게 나타났으며, 신장률의 경우 EVA 막이 가장 높게 나타났다. 불균질 이온교환막의 함수율은 이온교환수지의 함량이 증가함에 따라 증가하였으며 이온수송수는 PE 막의 경우 최대 0.973이었고, 전기저항값은 LLDPE막이 가장 낮게 나타났으며 수지의 함량 70 wt%일때 $10.36{\Omega}/cm^2$이었다.

강산성 양이온 교환수지를 충전한 고정층에서 리튬이온의 제거특성 (Removal Characteristics of Lithium Ions by Fixed-bed Column Packed with Strong-Acid Cation Exchange Resin)

  • 유해나;이민규
    • 청정기술
    • /
    • 제20권2호
    • /
    • pp.166-170
    • /
    • 2014
  • 강산성 양이온 교환수지를 충전한 고정층 컬럼을 사용하여 수중의 리튬이온을 제거하는 연속식 실험을 수행하였다. 층 높이, 유입 유량 및 유입 농도와 같은 파라미터들을 살펴보았으며, 파과곡선으로부터 파과시간($t_{0.05}$), 포화시간($t_{0.95}$) 및 제거된 리튬이온의 총량(mtotal)을 구하였다. 실험 결과 $t_{0.05}$$t_{0.95}$는 층 높이가 감소함에 따라 감소하였고, 유입 농도와 유입 유량이 증가함에 따라 감소하였다. mtotal은 유입 유량과 층 높이가 증가함에 따라 증가하였지만, 유입 유량이 증가함에 따라서는 감소하였다. 실험자료를 토마스 모델식과 윤-넬슨 모델식을 적용한 결과, 토마스 모델식이 파과 데이터에 잘 부합하였다.

Can prosthetic limbs made too quickly cause kidney damage?: a pilot study

  • Petrofsky, Jerrold S.;Browne, Mary;Jamshidi, Mahyar;Libo-on, Anthony;Lee, Haneul
    • Physical Therapy Rehabilitation Science
    • /
    • 제3권2호
    • /
    • pp.119-124
    • /
    • 2014
  • Objective: The use of chemicals for building prosthetic sockets present the possibility of being hazardous and unsafe due to off-gassing. The purpose of the present study was to investigate if freshly made materials used in prosthetic sockets causes off-gassing that would penetrate the skin and cause damage to the kidneys or blood. Design: Cross-sectional study. Methods: In this research, the off-gassing effects during the initial curing process of styrene monomer, vinyl ester resin, epoxy methacrylate resin, benzene-1, 3-dimethaneamine, trimethylhexanedlamine, and paratertiarybutylphenol were analyzed. Acid detection strips were placed inside newly fabricated mock-prosthetic sockets and left overnight in a closed environment to find out if acid was present in the invisible fumes. The plastic was worn by 9 subjects and urinalysis was made after 48 hours to test for any kidney or blood toxicity of the resins. Results: After wearing the plastic cuff for 48 hours, the ratio of protein to creatinine in the urine was raised to an abnormal level in five out of nine subjects. Four out of the nine subjects showed normal protein to creatinine ratios after wearing the device. The results showed that damage to the kidney occurred from wearing the resins after curing in half of the subjects. Conclusions: It is very important to conduct patient intakes which includes the assessment of renal function. Off-gassing in vented chambers may be needed to protect both prosthetists and patients.