• Title/Summary/Keyword: residual value

Search Result 930, Processing Time 0.033 seconds

Study on Electrical Characteristics of Chloromethylated Polyimide

  • Yu, I.H.;Zhong, Z-X;Lee, M.H.;Lee, S.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.472-475
    • /
    • 2005
  • The electrical performances of liquid crystal (LC) cells with chloromethylated polyimide (CMPI) alignment layers were investigated. The CMPI layer was previously reported as a multifunctional layer that does role of LC alignment and planarization layer as well as photo-alignment material with high photosensitivity and excellent thermal stability. The capacitance-voltage (C-V) characteristics of LC cells with CMPI alignment layers were measured. Mechanical rubbing of the CMPI layer did not generate much difference in residual DC when compared to commercial PI. However, the LC cell with photo-oxidation CMPI layer shows a high residual DC value and a corresponding low voltage holding ratio (VHR) due to the photo-induced ionic charges on the alignment layer.

  • PDF

Study on Thermal Stability of Liquid Crystal Display for Projection TV Application (프로젝션 TV 적용을 위한 액정 디스플레이의 열적 안정성에 관한 연구)

  • Kang, Hee-Jin;Hwang, Jeoung-Yeon;Oh, Yong-Cheul;Seo, Dae-Shik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.11
    • /
    • pp.1033-1036
    • /
    • 2006
  • We have investigated electro-optical characteristics in three kinds of twisted nematic (TN) cells on the polyimide surface. The threshold voltage and the response time of thermal stressed TN cells were same that of no thermal stressed TN cells. There were little change of value in these TN cells. On the other hand, transmittance of no thermal stressed TN cells were better than that of thermal stressed TN cells. Transmittances of TN cells on the polyimide surface decreased by increasing thermal stress time. Moreover, the residual DC of the thermal stressed TN cells increased as increasing thermal stress temperature and time. Therefore, thermal stability of TN cells were decreased gradually by giving high thermal stress for a long time.

Improvement of Mechanical Property by Single Ion Exchange Process in Substrate Glass

  • Lee, Hoi-Kwan;Kang, Won-Ho;Green, David J.
    • Journal of Information Display
    • /
    • v.4 no.3
    • /
    • pp.12-16
    • /
    • 2003
  • In connection with the ion exchange strengthening on soda-lime-silicate, substrate glass for display use was investigated. In the processing, the temperature was varied during the ion exchange in order to make stress profile and to determine optimum condition. In the present work, we found that the maximum value of strength was 617.8 MPa after an ion exchange process at 470 $^{\circ}C$ for 1h, and then, at 450 $^{\circ}C$ for 24h. Also, the effect of residual stress placed on the near surface was measured by analyzing the number of crack branches and brittleness. This approach allowed us the residual stress profile to be engineered to improve mechanical reliability.

Study for Thermal Stability of Liquid Crystal Device (액정 소자의 열적 안전성에 관한 연구)

  • 이상극;황정연;서대식;이준웅
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.4
    • /
    • pp.439-442
    • /
    • 2004
  • In this study, we investigated about electrooptics characteristic of three kinds of TN cell on the polyimide surface. Monodomain alignments of thermal stressed TN cell over temperature of liquid crystal isotropic phase were almost the same as that of no thermal stressed TN cells. However, the thermal stressed TN cells have many defects. Also, threshold voltage and response time of thermal stressed TN cells show the same performances as no thermal stressed TN cells. There were little changes of value in these TN cells. However, transmittances of TN cells on the polyimide surface decrease with increasing thermal stress time. Finally, the residual DC voltage of the thermal stressed TN cell on the polyimide surface shows decrease of characteristics as increasing thermal stress time. Therefore, the thermal stability of TN cell was decreased by high thermal stress for the long times.

Seismic response of dual structures comprised by Buckling-Restrained Braces (BRB) and RC walls

  • Beiraghi, Hamid
    • Structural Engineering and Mechanics
    • /
    • v.72 no.4
    • /
    • pp.443-454
    • /
    • 2019
  • In order to reduce the residual drift of a structure in structural engineering field, a combined structural system (dual) consisting of steel buckling-restrained braced frame (BRBF) along with shear wall is proposed. In this paper, BRBFs are used with special reinforced concrete shear walls as combined systems. Some prototype models of the proposed combined systems as well as steel BRBF-only systems (without walls) are designed according to the code recommendations. Then, the nonlinear model of the systems is prepared using fiber elements for the reinforced concrete wall and appropriate elements for the BRBs. Seismic responses of the combined systems subjected to ground motions at maximum considered earthquake level are investigated and compared to those obtained from BRBFs. Results showed that the maximum residual inter-story drift from the combined systems is, on average, less than half of the corresponding value of the BRBFs. In this research, mean of absolute values of the maximum inter-story drift ratio demand obtained from combined systems is less than the 3% limitation, while this criterion has not been fulfilled by BRBF systems.

Residual Stress and Elastic Modulus of Y2O3 Coating Deposited by EB-PVD and its Effects on Surface Crack Formation

  • Kim, Dae-Min;Han, Yoon-Soo;Kim, Seongwon;Oh, Yoon-Suk;Lim, Dae-Soon;Kim, Hyung-Tae;Lee, Sung-Min
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.6
    • /
    • pp.410-416
    • /
    • 2015
  • Recently, a new $Y_2O_3$ coating deposited using the EB-PVD method has been developed for erosion resistant applications in fluorocarbon plasma environments. In this study, surface crack formation in the $Y_2O_3$ coating has been analyzed in terms of residual stress and elastic modulus. The coating, deposited on silicon substrate at temperatures higher than $600^{\circ}C$, showed itself to be sound, without surface cracks. When the residual stress of the coating was measured using the Stoney formula, it was found to be considerably lower than the value calculated using the elastic modulus and thermal expansion coefficient of bulk $Y_2O_3$. In addition, amorphous $SiO_2$ and crystalline $Al_2O_3$ coatings were similarly prepared and their residual stresses were compared to the calculated values. From nano-indentation measurement, the elastic modulus of the $Y_2O_3$ coating in the direction parallel to the coating surface was found to be lower than that in the normal direction. The lower modulus in the parallel direction was confirmed independently using the load-deflection curves of a micro-cantilever made of $Y_2O_3$ coating and from the average residual stress-temperature curve of the coated sample. The elastic modulus in these experiments was around 33 ~ 35 GPa, which is much lower than that of a sintered bulk sample. Thus, this low elastic modulus, which may come from the columnar feather-like structure of the coating, contributed to decreasing the average residual tensile stress. Finally, in terms of toughness and thermal cycling stability, the implications of the lowered elastic modulus are discussed.

Optimization of organosolv pretreatment with sulfuric acid for enhancing enzymatic hydrolysis of Pitch Pine (Pinus rigida)

  • Park, Na-Hyun;Kim, Hye-Yun;Gwak, Ki-Seob;Koo, Bon-Wook;Yeo, Hwan-Myeong;Choi, In-Gyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.505-505
    • /
    • 2009
  • The object is to optimize the best condition of organosolv pretreatment process with sulfuric acid as a catalyst. As a material, Pitch pine (Pinus rigida) was ground and sieved through 40-mesh screen, and Celluclast and $\beta$-glucosidase were used as enzymes for enzymatic hydrolysis. Pretreatment processes were carried out in the minibomb, and 20 g of materials with 200 ml of 50% ethanol solution (v/v) with 1% sulfuric acid as a catalyst. Pretreatment temperature was varied from $150^{\circ}C$ to $190^{\circ}C$, and time was varied from 0 to 20 min. Then, residual materials were used for enzymatic hydrolysis. The best conditions were selected by estimating followed enzymatic hydrolysis rate and degradable rates after pretreatment process. The highest value of enzymatic hydrolysis rate was obtained as 55 - 60% at 160 and at $180^{\circ}C$, but the value decreased under more severe conditions. As the residual rates decreased under severe conditions, it infered that the decrease of sugar contents limits enzymatic hydrolysis rates. Combined with enzymatic hydrolysis rate, degradable rates and H-factors, the temperatures at $160^{\circ}C$ for 20 min and at $180^{\circ}C$ for 0 min were concluded as the optimized conditions where have the lowest H-factor value for considering energy input.

  • PDF

Performance Comparison of the CCA Adaptive Equalization Algorithm based on Compact Slice Weighting Values in 16-QAM Signal (16-QAM 신호에서 Compact Slice 가중치에 의한 CCA 적응 등화 알고리즘의 성능 비교)

  • Kang, Dae-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.4
    • /
    • pp.127-133
    • /
    • 2013
  • This paper compare the performance of CCA (Compact Constellation Algorithm) adaptive equalization algorithm by effect of the compact slice weighting value for minimization of the intersymbol interference in the communication channel. The CCA combines the conventional DDA and RCA algorithm, it uses the constant modulus of the transmission signal and the considering the output of decision device by the power of compact slice weighting value in order to improving the initial convergence characteristics and the equalization noise by misadjustment in the steady state. In this process, it is confirmed by computer simulation that the compact slice weight affects the performance of CCA adaptive equalization algorithm. The performance index includes the output signal constellation, the residual isi and maximum distortion and MSE that is for the convergence characteristics, the SER according to the signal and noise power ratio at the channel is used. As a result of computer, it shows that the large weighting value gives more good in every performance index. But in SER performance, it is known that the small values gives more good in low SNR and the large values gives more good in high SNR.

Dyeability of Nylon Fabrics with Dyestuff for Supercritical Fluid Dyeing (1) : C.I. Disperse Red 167, C.I. Disperse Violet 93 (초임계 유체 염색용 염료에 따른 Nylon 섬유의 염색 특성 (1) : C.I. Disperse Red 167, C.I. Disperse Violet 93 Azo계 염료)

  • Choi, Hyunseuk;Park, Shin;Kim, Taeyoung
    • Textile Coloration and Finishing
    • /
    • v.32 no.4
    • /
    • pp.217-225
    • /
    • 2020
  • In this study, the dyeing characteristics of nylon fabric which is dyed with supercritical fluid were investigated. There were two dyes used in the dyeing experiment: C.I. Disperse Red 167 and C.I. Disperse Violet 93. Dyeing temperature, pressure, and leveling time were fixed at 110℃, 250bar, 60minutes, and the experiment was conducted with dyeing concentration of 0.1, 0.3, 0.5, and 0.85% o.w.f. The analysis of the experimental results was found out through the measurement of washing fastness and color coordinate. In addition, the calibration curve of each dye was drawn up and the amount of remaining dye was checked by measuring the absorbance of the residual dye. As a result of color difference measurement, as the concentration increased, the L⁎ value decreased and the K/S value increased. However, the increase in K/S value compared to the amount of input decreased as the concentration increased. The comparative experiment on the amount of residual dye(C.I. Disperse Red 167) in the pot showed that 99.14% of the amount was dyed at the concentration of 0.1% o.w.f, while it rapidly decreased to 77% at 0.85% o.w.f. C.I. Disperse Violet 93 dye also decreased from 0.5% o.w.f to 93.91%. In the washing fastness experiment of both dyes, the level of washing fastness began to decrease from samples dyed at 0.5% o.w.f. It may be because the simply absorbed dye was produced instead of completely being fixed in the amorphous region of the nylon fiber.

Pulmonary Function Following Open Heart Surgery -early and late postoperative changes- (개심술후 폐기능 -수술직후 및 장기간의 추이에 대하여-)

  • 이성행
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.364-374
    • /
    • 1980
  • Twenty-two patients were selected for evaluation of pre-and postoperative pulmonary function. These patients were performed open cardiac surgery with the extracorporeal circulation from March 1979 to July 1980 at the Department of Thoracic and Cardiovascular Surgery, Kyungbook National University Hospital. Patients were classified with ventricular septal defect 5 cases, atrial septal defect 5 cases, tetralogy of Fallot 5 cases, mitral stenosis 4 cases, rupture of aneurysm of sinus Valsalva 1 case, left atrial myxoma I case, and aortic insufficiency 1 case. The pulmonary function tests were performed and listed: [1] respiratory rate, tidal volume [TV], and minute volume[MV], [2] forced vital capacity [FVC] and forced expiratory volume[FEV 0.5 & FEV 1.0], [3] forced expiratory flow [FEF 200-1200 ml & FEF 25-75%]. [4] Maximal voluntary ventilation [MVV], [5] residual volume [RV] and functional residual capacity[FRC], measured by a helium dilution technique. Respiratory rate increased during the early postoperative days and tidal volume decreased significantly. These values returned to the preoperative levels after postoperative 5-6 days. Minute volume decreased slightly, but essentially unchanged. Preoperative mean values of the forced vital capacity, functional residual capacity and total lung capacity decreased [63.2%, 87.2% & 77.3% predicted, respectively], and early postoperatively these values decreased further [19.6%, 76.0% & 38.0% predicted], but later progressively increased to the preoperative levels. In residual volume, there was no decline in the preoperative mean values [100.9% predicted] and postoperatively the value rather increased [106.3-161.7% predicted]. Forced expiratory volume [FEV 0.5 & FEV 1.0] and forced expiratory flow [FEF 200-1200 ml & FEF 25-75%] also revealed significant declines in the early postoperative period. There was no significant difference in values of the spirometric pulmonary function tests, such as FEF 1.O and FEF 25-75% between successful weaning group [17 cases] extubated within 24 hrs post-operatively and unsuccessful weaning group [5 cases] extubated beyond 24 hrs. Static compliance and airway resistance measured for the two cases during assisted ventilation, however, any information was not obtained. Long term follow-up pulmonary function studies were carried out for 8 cases in 9 months post-operatively. All of the results returned to the pre-operative or to normal predicted levels except FVC, FEV 1.0, and FEF 25-75% those showed minimal declines compared to the pre-operative figures.

  • PDF