• Title/Summary/Keyword: residual time

Search Result 2,097, Processing Time 0.035 seconds

Assessment of Variable Characteristics in Water Quality of the Supply Systems in the Building (건축물내 급수설비의 수질변화 특성과 영향력 평가)

  • Lee, H.D.;Hwang, J.W.;Bae, C.H.;Kim, S.J.
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.4
    • /
    • pp.313-320
    • /
    • 2004
  • In this study, variable characteristics of drinking water and the influences on underground water reservoirs, rooftop water tanks, and service water pipes in the building were assessed. The influence of underground water reservoir material and water capacity on water quality also were assessed. The results are the following as; First of all, the drinking water passing through underground water reservoirs or service water pipes in the building, averagely metal component concentration more increased from percent of 41.3 to percent of 74.2 totally than other items of water quality. On the other hand, both residual chlorine and total solid highly decreased 65.6 percent and 35.3 percent, respectively. Therefore, it was thought that water quality could be getting worse for microorganism re-growth by residual chlorine reduction, and total solid also could be a cause for extraneous matters accumulated in water reservoir. Secondly, the variations on water quality of each stage for water supply system in the building were higher in water service pipes connected from rooftop water tanks to the tap than in underground water reservoirs. In addition to, among of twelve items on water quality, ten items on water quality except dissolved oxygen and residual chlorine increased. Therefore, it was thought that the influence of water service pipes connected from rooftop water tanks to the tap on water quality were higher than other stages of water supply system in the building. Thirdly, in case of materials of underground water reservoir, it was likely that the variation on water quality by stainless steel and concrete materials got some similar. In case of water capacity, the variations on water quality of underground water reservoirs over $1,000m^3$ higher than those under $1,000m^3$. That reasons was likely that the retention time(49.72 hours averagely) of underground water reservoirs over $1,000m^3$ was two times longer than it of those under $1,000m^3$(23.37 hours). Therefore, it was thought that the influence on water quality by materials were some similar, but in case of water capacity, the influence of underground water reservoirs were higher.

Establishment of An Optimal Process to Improve Structural Integrity by Investigating Effect of the Process Variables on Fatigue Lifetime of Steel-Sleeve Repair Welds in Buried Gas Pipeline (매설가스배관 강 슬리브 보수 용접부의 피로수명에 미치는 공정변수 영향 고찰을 통한 최적공정 수립)

  • Kim, Jong Sung;Lee, Cheol;Kim, Woo Sik;Kim, Ik Jung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.11
    • /
    • pp.1021-1033
    • /
    • 2017
  • In this study, an optimum process to improve structural integrity was established by investigating effect of the process variables on fatigue lifetime of steel-sleeve repair welds in buried gas pipeline. Residual stresses in the repair welds were derived through sequentially-coupled temperature-stress analysis using ABAQUS, which is a commercial finite element analysis program. In addition, variations of operating stresses were derived by finite element linear elastic stress analysis. Fatigue lifetimes of the steel-sleeve repair welds were evaluated by substituting the derived weld residual stresses and operating stress variations into the structural stress/fracture mechanics approach as input. Parametric study using finite element analysis and fatigue assessment for various repair welding process variables were carried out to investigate the effects of the process variables on the fatigue lifetime. Finally, based on the effects of the process variables on the fatigue lifetime, an optimal process to minimize the welding time and economic costs and to improve the fatigue lifetimes was derived.

Biological Dosimetry of In Vitro Irradiation with Radionuclides : Comparison of Whole Blood, Lymphocyte and Buffy Coat Culture (전혈, 림프구와 백혈구 연층 각각의 방사성 동위원소 체외 조사 후 배양을 이용한 생물학적 선량측정)

  • Kim, Jong-Ho;Lee, Dong-Soo;Choi, Chang-Woon;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Kim, Chong-Soon;Kim, Hee-Geun;Kang, Duck-Won;Song, Myung-Jae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.125-132
    • /
    • 1995
  • The purpose of this study was to establish mononuclear cell cultures such as lymphocytes or buffy coat for the biological dosimetry of in vitro Irradiation of the radionuclide Tc-99m in order to exclude the effect of residual doses seen in the cultures of whole blood. Biological do simetry of Tc-99m on cultured mononuclear cells at doses ranging from 0.05 to 6.00 Gy, by scoring unstable chromosomal aberrations(Ydr) observed in cultured lymphocytes, were performed using peripheral venous blood of healthy normal person. The results showed that; (1) In vitro irradiation of radioisotope in separated lymphocyte or buffy coat showed trace amount of residual doses of isotope after washing. Residual doses of isotopes are increased in proportion to exposed time and irradiated dose without difference between I-131 and Tc-99m. (2) We obtained these linear-quadratic dose response equations in lymphocyte and buffy coat culture after in vitro irradiation of Tc-99m, respectively (Ydr = 0.001949 $D^2$ +0.006279D + 0.000185; Ydr= 0.002531 $D^2$-0.003274 D+0.003488). In conclusion, the linear quadratic dose-response equation from in vitro irradiation of Tc-99m with lymphocyte and buffy coat culture was thought to be useful for assessing Tc-99m induced biological effects. And mono-nuclear cell cultures seem to be the most appropriate experimental model for the assessment of biological dosimetry of internal irradiation of radionuclides.

  • PDF

Effects of Foliar Treatment of Underground Water, Chitosan Solution, and Wood Vinegar Solution on Residual Procymidone Removal in Altari Radish (지하수, 키토산 및 목초액의 엽면살포에 의한 알타리무 체내의 잔류 Procymidone 제거효과)

  • Jeong, Soon-Jae;Cho, Mi-Yong;Seok, Woon-Young;Oh, Ju-Sung
    • Korean Journal of Organic Agriculture
    • /
    • v.19 no.1
    • /
    • pp.121-134
    • /
    • 2011
  • For this study, Smilex powder, a pesticide, was sprayed on the Altari radish, and then underground water, Chitosan solution (${\times}$500), and wood vinegar solution (${\times}$1000) were evenly sprayed on the Altari radish respectively. Samples of Altari radishs for residual pesticide analysis were taken two hours, 1 day, 7 days, and 15 days after treatments, and the detectable concentration and degradability of procymidone, the pesticide residue, were measured. The results obtained are as follows: 1. When detectable concentration of procymidone within the altari radish was measured, treatment plots sprayed with underground water, Chitosan solution (${\times}$500), and wood vinegar solution (${\times}$1000) were found to show lower detectable concentration than the non-treatment plot which was sprayed with pesticide only. Especially, the treatment plots sprayed with Chitosan solution (${\times}$500), and with wood vinegar solution (${\times}$1,000) showed lower values than the average. 2. When the degradability of procymidone within the Altari radish was measured, the plot treated with Chitosan solution (${\times}$500) and the plot treated with wood vinegar solution (${\times}$1,000) were found to have relatively higher degradability of procymidone. There were not much differences among testing materials in the degradability of residual pesticides. However, the plot treated with Chitosan solution (${\times}$500) showed higher degradability. In terms of average degradability with time, degradability increased sharply 7 days after the foliar application of testing materials. 3. When the daily far-sighted view survey was conducted in order to find out growth disorder and damage on the Altari radish plants by the treatment of un-derground water, Chitosan solution (${\times}$500), and wood vinegar solution (${\times}$1,000), no symptomatic physiological disorders was observed on all the plants tested during the whole growing season at the tested concentration level.

Survival and Physiological Response of Olive Flounder, Paralichthys olivaceus Exposed to Seawater Chlorinated by Chlorine Dioxide ($CIO_2$) (이산화염소($CIO_2$) 처리해수에 노출된 넙치, Paralichthys olivaceus의 생존과 생리적 반응)

  • 김흥윤;김진도
    • Journal of Aquaculture
    • /
    • v.16 no.3
    • /
    • pp.151-158
    • /
    • 2003
  • This study was conducted to estimate the effects of residual chlorine dioxide ($CIO_2$) in chlorinated seawater on survival and physiological responses (hematocrit: Ht, hemoglobin: Hb, serum electrolyte and glucose levels, and osmolality) of olive flounder, Paralichthys olivaceus. All the flounders were exposed for 10 min to different concentrations of residual $CIO_2$ just after chlorination for 1 min in each experimental aquarium (EA). ClO$_2$-free seawater was continuously supplied to each EA after 10 min exposure to $CIO_2$. By means of probit analysis, the median lethal times (LT$_{50}$, min) of flounder exposed to 0.43 and 0.51 ppm $CIO_2$, were at 103 and 32 min, respectively. In the range from 0.34 to 0.51 ppm $CIO_2$, the values of Ht, Hb, electrolytes and osmolality of fish exposed to $CIO_2$ were significantly elevated as elapsed time and residual concentrations of $CIO_2$ increased after chlorination. The levels of Ht, Hb, electrolytes and osmolality in flounder exposed to 0.27 ppm $CIO_2$ were not significantly different compared to control fish, which were maintained in $CIO_2$-free seawater; however, the levels of serum glucose were significantly increased with elapse times.

Use of Hydrogen Peroxide with Ozone to Simultaneously Reduce MIB and Quench Ozone Residual in Existing Water Treatment Plants Sourcing Water from the Han River (한강을 원수로 하는 오존/과산화수소 고도정수처리공정에서의 MIB제거 및 잔류오존 농도에 관한 연구)

  • McAdams, Stephen R.;Koo, Bon Jin;Jang, Myung Hoon;Lee, Sung Kyoo
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.5
    • /
    • pp.704-716
    • /
    • 2012
  • This paper provides a detailed account of pilot testing conducted at South Lake Tahoe (California), the Ddukdo (Seoul) water treatment plant (WTP) and the Bokjung (Seongnam) WTP between February, 2010, and February, 2012. The objectives were first, to characterize the reactions of ozone with hydrogen peroxide (Peroxone) for Han River water following sand filtration, second to determine empirical ozone and hydrogen peroxide doses to remove a taste-and-odor surrogate 2-methylisoborneol (MIB) using an advanced oxidation process (AOP) configuration and third, to determine the optimum dosing configuration to reduce residual ozone to a safe level at the exit of the process. The testing was performed in a real-time plant environment at both low- and high seasonal water temperatures. Experimental results including ozone decomposition rates were dependent on temperature and pH, consistent with data reported by other researchers. MIB in post-sand-filtration water was spiked to 40-50 ng/L, and in all cases, it was reduced to below the specified target level (7 ng/liter) and typically non-detect (ND). It was demonstrated that Peroxone could achieve both MIB removal and low effluent ozone residual at ozone+hydrogen peroxide doses less than those for ozone alone. An empirical predictive model, suitable for use by design engineers and operating personnel and for incorporation in plant control systems was developed. Due to a significant reduction in the ozone reaction/decomposition at low winter temperatures, results demonstrate the hydrogen peroxide can be "pre-conditioned" in order to increase initial reaction rates and achieve lower ozone residuals. Results also indicate the method, location and composition of hydrogen peroxide injection is critical to successful implementation of Peroxone without using excessive chemicals or degrading performance.

Convergence Speed Improvement in MMA Algorithm by Serial Connection of Two Stage Adaptive Equalizer (2단 적응 등화기의 직렬 연결에 의한 MMA 알고리즘의 수렴 속도 개선)

  • Lim, Seung-Gag
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.3
    • /
    • pp.99-105
    • /
    • 2015
  • This paper deals with the mMMA (modified MMA) which possible to improving the convergence speed that employing the serial connecting form of two stage digital filter instead of signal filter of MMA adaptive equalizer without applying the variable step size for compensates the intersymbol interference by channel distortion in the nonconstant modulus signal. The adaptive equalizer can be implemented by signal digital filter using the finite order tap delay line. In this paper, the equalizer is implemented by the two stage serial form and the filter coefficient are updated by the error signal using the same algorithm of MMA in each stage. The fast convergence speed is determined in the first stage, and the residual isi left at the output of first stage output is minimized in the second stage filter. The same digital filter length was considered in single stage and two stage system and the performance of these systems were compared. The performance index includes the output signal constellation, the residual isi and maximum distortion, MSE that is measure of the convergence characteristics, the SER. As a result of computer simulation, mMMA that has a FIR structure of two stage, has more good performance in every performance index except the constellation diagram due to equalization noise and improves the convergence speed about 1.5~1.8 time than the present MMA that has a FIR structure of single stage.

The characteristics of chloramine formation and decay with pH variation (pH 변화에 따른 클로라민 생성과 분해 특성)

  • 조관형;김평청;우달식;조영태
    • Journal of Environmental Science International
    • /
    • v.11 no.4
    • /
    • pp.347-353
    • /
    • 2002
  • This study was conducted to investigate the characteristics of chloramination as a secondary disinfection in a drinking water distribution system. At the range from pH 6 to pH 8, monochloramine was predominant with a trace of dichloramine, and the free chlorine was detected after breakpoint. At $25^{\circ}C$, the breakpoints of pH 6, 7 and 8 appeared when the weight ratios of chlorine to ammonia nitrogen were 11:1, 9:1 and 10:1 respectively, and the peak points on the breakpoint curves at pH 6, 7 and 8 were in the Cl$_2$ / NH$_3$-N ratio of 9:1, 6:1 and 5:1 respectively. As pH increased from 6 to 8, maximum point of monochloramine on the breakpoint curve was moved from 7:1 to 5:1 in the weight ratio of chlorine to ammonia nitrogen. The maximum concentration of monochloramine was formed at the pH values of 7~8 and in the Cl$_2$ / NH$_3$-N ratio below 5:1. As the Cl$_2$/NH$_3$-N ratio increased and the pH lowered, chloramines decay proceeded at an increased rate, and residual chloramines lasted longer than the residual free chlorine. The monochloramine and the dichloramine were formed at pH 6, and then the dichloramine continued increasing with contact time.

Deduction for Key Uncertainty Factors for the Next-generation Convergence Service (차세대 컨버전스서비스 핵심불확실성요인 도출에 관한 분석)

  • Sawng, Yeong-Wha;Park, Sun-Young;Lee, Jung-Mann
    • Journal of Korea Technology Innovation Society
    • /
    • v.12 no.1
    • /
    • pp.212-236
    • /
    • 2009
  • This study is an attempt to deduct environmental uncertainties facing next-generation convergence services, in four areas including customer, technology, service provider and regulation. We assess the level of residual uncertainty with regard to key environmental uncertainty factors, and conduct a scenario planning analysis. Based on the results of this analysis, we provide suggestions on market entry strategy for providers of this next-generation convergence service. The strategic assessment of six scenarios developed in this study, each with two levels of residual uncertainty (alternate futures and a range of futures) resulted in two key success factors (KSF), namely, customer demand trends and easing of advertising restrictions. Four types of strategic scenarios were then discerned, for each of which we present response capabilities that may be required of service providers, along with strategic suggestions. The results of this study are rich in implications for both policy-makers and regulators seeking ways to create and stimulate a convergence service market and prospective providers of next-generation convergence services, as they provide concrete tips related to market entry strategy, including efficient resource allocation, types of market entry and time-frames for entry.

  • PDF

An Analytical Study on Composite Beam Performance with Post-Fire Temperature Using ANSYS Program (ANSYS를 이용한 화재 후 온도에 따른 합성보 성능에 관한 해석적 연구)

  • Kwak, Sung-Shin;Choi, Byong-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.391-400
    • /
    • 2019
  • In the case of fire, a structure loses its original stiffness due to the temperature rise, and the load bearing capacity decreases. The loss of structural strength increases with increasing fire time of the structure. To prevent the collapse of buildings, it is very important to understand whether or not the members are damaged. On the other hand, there is insufficient data to be a guideline for diagnosing and evaluating the residual strength of the members in Korea. Therefore, this study examined the resistance performance by Finite-Element-Analysis of composite beams, which are composite structures among structural members. Composite beam modeling was carried out based on the model used in the Electrical Penetration Room (EPR) in cooperation with KEPCO. The heat transfer analysis and structural analysis of the critical phase were performed using ANSYS, a finite element analysis program. ANSYS was used to perform heat transfer analysis and structural analysis at the static analysis. To analyze the residual performance, the temperature distribution of the composite beam and the maximum displacement result of the heat-affected structure analysis were derived and the experimental data and the structural analysis result data were compared and analyzed.