• Title/Summary/Keyword: residual time

Search Result 2,098, Processing Time 0.031 seconds

Prediction of Post-Deformation for Plastic Component Considering Residual Stress and Viscoelasticity (판류응력 및 점탄성을 고려한 플라스틱 부품의 후면형 예측)

  • Moon, H.I.;Kim, H.Y.;Choi, C.W.;Jeong, K.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.10a
    • /
    • pp.341-344
    • /
    • 2008
  • Plastics is commonly used in consumer electronics because of it is high strength per unit mass and good productivity. But. using, transporting, and keeping of plastic component was happened post-deformation. As time goes by and temperature is changed, the post-deformation causes the problems of exterior design and performance. But, it is difficult to estimate the post-deformation by only thermal deformation analysis. Also, the estimation technique of the pest-deformation must be easily applied to product development and it should be reliable because development time of product is limited. In the paper. the process to predict the post deformation under cyclic thermal loadings was suggested. The process was applied to the real panel, and the deformation predicted by the analysis was compared with that of real test, which showed the possibility of applying the suggested process to predict the post deformation of plastic product under thermal loadings.

  • PDF

Characteristics of Adsorption on the RO Membrane Surface by Coagulants Types (응집제 종류에 따른 RO막 표면 흡착 특성)

  • Jeong, Youngmi;Park, Chanhyuk;Lee, Sanghyup;Kweon, Jihyang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.477-483
    • /
    • 2007
  • A coagulation process for RO (reverse osmosis) membrane pretreatment system was an effective technology to remove colloidal and particulate matters. However, coagulant residuals from the pretreatment process may negatively affect RO membrane performance. The bench-scale coagulant exposure study was performed to investigate the effect of their residual on adsorbed mass which related to the membrane performance. Coagulant addition in this study ranged from 0 to 5mg/L ferric chloride, alum, and 2mg/L cationic polymer(poly-di-methyldiallyl ammonium chloride) as coagulant aids. This results showed that adsorbed mass is not significantly increased during short-time period, however, accumulated mass of coagulants on the membrane surface is significantly increased during long-time experimental period. The effect of pH on coagulants adsorption characteristics was significantly differed due to the electrostatic repulsive interactions between soluble coagulants and membrane surface charge. This data suggest that the RO membrane performance of drinking water treatment plant could be decreased by adsorption of residual coagulants when applied for the coagulant pretreatment process.

Comparison of Efficiency between Pre-storage and Post-storage filtration by Leukoreduction Blood Filter

  • Shin, Geon Sik;Kim, Bohee;Kim, Sung Hoon;Rhee, Ki-Jong;Kim, Yoon Suk
    • Biomedical Science Letters
    • /
    • v.23 no.2
    • /
    • pp.111-117
    • /
    • 2017
  • Leukocytes in blood components are involved in diverse adverse transfusion reactions such as febrile non-hemolytic transfusion reactions. Therefore, leukocyte reduction is required to reduce these adverse reactions. The objective of this study was to compare the efficiency of pre-storage filtration and post-storage filtration. Filtration time, residual leukocyte count, RBC recovery, and hemolysis were assessed after pre-storage or post-storage filtration. Compared to pre-storage filtration, filtration time was prolonged and hemolysis was dramatically increased when post-storage filtration was performed. Residual leukocytes count and RBC recovery after post-storage filtration were similar with those obtained after pre-storage filtration. These results suggest that pre-storage filtration has better efficiency than post-storage filtration. These are thought to contribute to the production of better quality of leukoreduction blood components.

Continuous Production of Cyclodextrin in Two-Stage Immobilized Enzyme Reactor Coupled with Ultrafiltration Recycle System (2단계 고정화 효소반응기를 활용한 Cyclodextrin의 연속생산)

  • Lee, Yong-Hyun;Lee, Sang-Ho;Han, Il-Keun
    • Microbiology and Biotechnology Letters
    • /
    • v.19 no.2
    • /
    • pp.171-178
    • /
    • 1991
  • The two-stage enzyme reactor, packed with cyclodextrin glucanotransferase (CGTase) immobilized on Amberite IRA 900, coupled with ultrafiltration membrane was investigated for continuous production of cyclodextrin (CD). 5% (w/v) of soluble starch was partially cyclized, in the 0.1 l first-stage immobilized enzyme reactor, up to CD conversion yield of 10% (w/w) at retention time of 0.56hr and 1.5 units of immobilized CGTase/1g of carrier. In the second stage main immobilized enzyme reactor capacity of 1.5 l, the maximum CD conversion yield of 39% (w/v) was achieved at retention time of 2.8hr and 0.47 unit of CGTase/1 g of carrier. Unreacted residual dextrin was fractionated with ultrafiltration membrane, and then, recycled into the second-stage main bioreactor to increase the CD conversion yield. The most suitable membrane size and the volume concentration ratio (concentrate: filterate) for recycling of unreacted residual dextrin were found to be 5K dalton and 4:6, respectively. CD conversion yield was increased about 3~4% upon co-immobilization of pulluanase along with CGTase. Spent Amberite IRA 900 can be reutilized consecutively more than 3 times for immobilization of CGTase after regeneration.

  • PDF

Postfire reliability analysis of axial load bearing capacity of CFRP retrofitted concrete columns

  • Cai, Bin;Hao, Liyan;Fu, Feng
    • Advances in concrete construction
    • /
    • v.10 no.4
    • /
    • pp.289-299
    • /
    • 2020
  • A reliability analysis of the axial compressive load bearing capacity of postfire reinforced concrete (RC) columns strengthened with carbon fiber reinforced polymer (CFRP) sheets was presented. A 3D finite element (FE) model was built for heat transfer analysis using software ABAQUS. Based on the temperature distribution obtained from the FE analysis, the residual axial compressive load bearing capacity of RC columns was worked out using the section method. Formulas for calculating the residual axial compressive load bearing capacity of the columns after fire exposure and the axial compressive load bearing capacity of postfire columns retrofitted with CFRP sheets were developed. Then the Monte Carlo method was used to analyze the reliability of the axial compressive load bearing capacity of the RC columns retrofitted with CFRP sheets using a code developed in MATLAB. The effects of fire exposure time, load ratio, number of CFRP layers, concrete cover thickness, and longitudinal reinforcement ratio on the reliability of the axial compressive load bearing capacity of the columns after fire were investigated. The results show that within 60 minutes of fire exposure time, the reliability index of the RC columns after retrofitting with two layers of CFRPs can meet the requirements of Chinese code GB 50068 (GB 2001) for safety level II. This method is effective and accurate for the reliability analysis of the axial load bearing capacity of postfire reinforced concrete columns retrofitted with CFRP.

k-Fragility Maximization Problem to Attack Robust Terrorist Networks

  • Thornton, Jabre L.;Kim, Donghyun;Kwon, Sung-Sik;Li, Deying;Tokuta, Alade O.
    • Journal of information and communication convergence engineering
    • /
    • v.12 no.1
    • /
    • pp.33-38
    • /
    • 2014
  • This paper investigates the shaping operation problem introduced by Callahan et al., namely the k-fragility maximization problem (k-FMP), whose goal is to find a subset of personals within a terrorist group such that the regeneration capability of the residual group without the personals is minimized. To improve the impact of the shaping operation, the degree centrality of the residual graph needs to be maximized. In this paper, we propose a new greedy algorithm for k-FMP. We discover some interesting discrete properties and use this to design a more thorough greedy algorithm for k-FMP. Our simulation result shows that the proposed algorithm outperforms Callahan et al.'s algorithm in terms of maximizing degree centrality. While our algorithm incurs higher running time (factor of k), given that the applications of the problem is expected to allow sufficient amount of time for thorough computation and k is expected to be much smaller than the size of input graph in reality, our algorithm has a better merit in practice.

AGE ESTIMATION TECHNIQUE OF INDUSTRIALIZED TIMBER PLANTATION USING VARIOUS REMOTE SENSING DATA

  • Kim, Jong-Hong;Heo, Joon;Park, Ji-Sang
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.94-97
    • /
    • 2006
  • Timber stand age information of timber in industrialized plantation forest is generally collected by field surveying which is labor-intensive, time-consuming, and very costly. It is also inconsistent in analyses perspective. As an alternative, The objective of this research is to present a practical solution for estimating timber age of loblolly pine plantation using Landsat thematic mapper (TM) images, shuttle radar topography mission (SRTM), and national elevation dataset (NED). A multivariate regression model was developed based upon satellite image-based information (i.e.normalized difference vegetation index (NDVI), tasseled cap (TC) transformation, and derived tree heights). A residual studentized technique was applied to remove potential outliers. After that, a refined age estimation model with a correlation coefficient R-square of 84.6% was obtained. Finally, the feasibility test of estimated model was performed by comparing estimated and measured stand ages of timber plantations using test datasets of plantation stands (2,032 stands). The result shows that the proposed method of this study can estimate loblolly pine stand age within an error of $2{\sim}3$ years in an effective and consistent way in terms of time and cost.

  • PDF

Long-Term GPS Satellite Orbit Prediction Scheme with Virtual Planet Perturbation (가상행성 섭동력을 고려한 긴 주기 GPS 위성궤도예측기법)

  • Yoo, Seungsoo;Lee, Junghyuck;Han, Jin Hee;Jee, Gyu-In;Kim, Sun Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.11
    • /
    • pp.989-996
    • /
    • 2012
  • The purpose of this paper is to analyze GPS (Global Positioning System) satellite orbital mechanics, and then to propose a novel long-term GPS satellite orbit prediction scheme including virtual planet perturbation. The GPS orbital information is a necessary prerequisite to pinpointing the location of a GPS receiver. When a GPS receiver has been shut down for a long time, however, the time needed to fix it before its reuse is too long due to the long-standing GPS orbital information. To overcome this problem, the GPS orbital mechanics was studied, such as Newton's equation of motion for the GPS satellite, including the non-spherical Earth effect, the luni-solar attraction, and residual perturbations. The residual perturbations are modeled as a virtual planet using the least-square algorithm for a moment. Through the modeling of the virtual planet with the aforementioned orbital mechanics, a novel GPS orbit prediction scheme is proposed. The numerical results showed that the prediction error was dramatically reduced after the inclusion of virtual planet perturbation.

Multi-analysis of the Organochlorine Pesticides in Ginseng at Gyeongbuk, Korea (경북지역 인삼 중 유기염소계 농약의 다성분 분석)

  • Park Moon-Ki;Kim Jung-Ho
    • Journal of Environmental Science International
    • /
    • v.14 no.2
    • /
    • pp.193-199
    • /
    • 2005
  • To obtain the residual organochlorine pesticides in the ginseng, the methods of multi-analysis for BHC's isomer, DDT's isomer and other organochlorine pesticides by GC-ECD are surveyed. The relative retention time for $\alpha-BHC,\;\beta-BHC,\;\delta-BHC\;and\;\gamma-BHC$ is 1.000, 1.025, 1.034 and 1.056, respectively. The relative retention time for o,p-DDE, p,p-DDE, o,o-DDD, o,p-DDT, o,p-DDD, and p,p-DDT is 1.199, 1.230, 1.242, 1.286, 1.329 and 1.333, respectively. The BHC isomers, DDT's isomer and other organochlorine pesticides are separated with multianalysis condition. The qualified defection concentration for $\alpha-BHC$, Quintozene, Aldrin, Captan, $\alpha-Endosulfan$, and Dieldrin is 0.95ng/g, 0.27ng/g, 1.04ng/g, 0.63ng/g, 0.55ng/g and 0.62ng/g, respectively. The qualified defection concentration for Fenhexamid, Endrin, $\beta-Endosulfan$, o,p-DDT, Endosulfan-sulfate is 5.71ng/g, 0.61ng/g, 0.48ng/g, 0.44ng/g and 0.51ng/g, respectively. BHC, Aldrin, Dieldrin, Endrin and DDT, which were Korea Food & Drug Administration advisory pesticides, are not detected in soil environment. Also it's residual organochlorine pesticides are not polluted in the ginseng on Sangju Korea.

Inactivation of Ralstonia Solanacearum using Filtration-Plasma Process (여과-Plasma 공정을 이용한 Ralstonia Solanacearum 불활성화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.23 no.6
    • /
    • pp.1165-1173
    • /
    • 2014
  • For the field application of dielectric barrier discharge plasma reactor in nutrient solution culture, a filtration-DBD (dielectric barrier discharge) plasma reactor was investigated for the Ralstonia solanacearum which causes bacterial wilt in aquiculture. The filtration-DBD plasma reactor system of this study was consisted of filter, plasma reactor, reservoir. The DBD plasma reactor consisted of a quartz dielectric tube, discharge electrode (inner) and ground electrode (outer). The experimental results showed that the inactivation of R. solanacearum with filter media type in filter reactor ranked in the following order: anthracite > fiber ball > sand > ceramic ball > quartz ceramic. In filtration + plasma process, disinfection effect with the voltage was found to small. In disinfection time of 120 minutes, residual R. solanacearum concentration was 1.17 log (15 CFU/mL). When the continuous disinfection time was 120 minute, disinfection effect was thought to keep the four days. In sporadic operation mode of 30 minutes disinfection - 24 hours break, residual R. solanacearum concentration after five days was 0.3 log (2 CFU/mL). It is considered that most of R. solanacearum has been inactivated substantially.