• Title/Summary/Keyword: residual layer thickness

Search Result 116, Processing Time 0.027 seconds

A Geophysical Study of a Deep sea basin southeast of the Hawaiian Island: Gravity, Magnetic, and Seismic Profiling (Hawaii 동남부 심해저 분지에 대한 지구물리학적 연구 : 중력, 자력 및 탄성파 탐사)

  • 서만철;박찬홍
    • 한국해양학회지
    • /
    • v.26 no.1
    • /
    • pp.1-12
    • /
    • 1991
  • A multi-disciplinary geophysical study including gravity, magnetic, and seismic reflection profiling was carried out in the area between the Clarion fracture zone and the Clippertone fracture zone o the northeastern equatorial Pacific basin. There are small free-air gravity anomalies of less than 20 mgal over seamounts and the east-west trending abyssal hills. The negative residual gravity anomalies over seamounts may indicate the existence of low density seamount roots compared to surrounding oceanic crust. Non-existence of magnetic lineations and the magnetic anomalies of small smplitude with no polarity change in the east-west direction support that the study area belongs to the Cretaceous magnetic quite zone. Positive magnetic anomalies over seamounts offset 100 km in the east-west direction in the southern part of the study area suggest a possibility of left-lateral movement of those seamounts along unknown fractures. The sedimentary section in the study area can be divided into three units (Unit I, unit IIA, and Unit IIB) n the basis of reflection characteristics. the total thickness of sedimentary section varies from 200 to 400 meters and the sedimentary section is thicker in the southern area of rough topography near the seamount belt than in the northern flat area. Manganese nodules are abundant in the southern part of the study area where the ridges are developed and the Unit I layer is thicker than 100 meters.

  • PDF

Optimization of Crack-Free Polytypoidally Joined Dissimilar Ceramics of Functionally Graded Material (FGM) Using 3-Dimensional Modeling (폴리타이포이드 경사 방식으로 접합 된 이종 세라믹간의 적층 수의 최적화 및 잔류응력 해석에 대한 연구)

  • Ryu, Sae-Hee;Park, Jong-Ha;Lee, Sun-Yong;Lee, Jae-Sung;Lee, Jae-Chul;Ahn, Sung-Hoon;Kim, Dae-Keun;Chae, Jae-Hong;Riu, Do-Hyung
    • Korean Journal of Materials Research
    • /
    • v.18 no.10
    • /
    • pp.547-551
    • /
    • 2008
  • Crack-free joining of $Si_3N_4\;and\;Al_2O_3$ using 15 layers has been achieved by a unique approach introducing Sialon polytypoids as a functionally graded materials (FGMs) bonding layer. In the past, hot press sintering of multilayered FGMs with 20 layers of thickness $500{\mu}m$ each has been fabricated successfully. In this study, the number of layers for FGM was reduced to 15 layers from 20 layers for optimization. For fabrication, model was hot pressed at 38 MPa while heating up to $1700^{\circ}$, and it was cooled at $2^{\circ}$/min to minimize residual stress during sintering. Initially, FGM with 15 layers had cracks near 90 wt.% 12H / 10 wt.% $Al_2O_3$ and 90 wt.% 12H/10 wt.% $Si_3N_4$ layers. To solve this problem, FEM (finite element method) program based on the maximum tensile stress theory was applied to design optimized FGM layers of crack free joint. The sample is 3-dimensional cylindrical shape where this has been transformed to 2-dimensional axisymmetric mode. Based on the simulation, crack-free FGM sample was obtained by designing axial, hoop and radial stresses less than tensile strength values across all the layers of FGM. Therefore, we were able to predict and prevent the damage by calculating its thermal stress using its elastic modulus and coefficient of thermal expansion. Such analyses are especially useful for FGM samples where the residual stresses are very difficult to measure experimentally.

The South Sea Circulation of Korea: Two-dimensional Barotrophic Model (한국 남해의 해수순환: 2차원 순압모델)

  • Chang, Kyung-Il;Park, Kyeong;Suk, Moon-Sik;Kim, Choong-Ki
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.5 no.4
    • /
    • pp.257-266
    • /
    • 2000
  • A vertically-averaged, two-dimensional version of the Princeton Ocean Model has been applied to the South Sea to simulate the circulation driven by tides and inflows/outflows across open boundaries. To incorporate both forcing properly, a two-step modeling approach is adopted, in which the tidal circulation is first simulated by specifying the tides along the open boundaries, and then both the calculated tidal currents and the observed steady mean currents are prescribed across the open boundaries. Model results show that the steady, subtidal circulation of the South Sea is different from the residual circulation due to tidal rectification, and subtidal currents become locally as strong as tidal currents. The Cheju Current entering the model domain across the Cheju Strait flows eastward in general while shifting onshore or offshore areas following local isobaths. The Tsushima Current entering across the southern boundary reaches farther to the north in the eastern vicinity of Cheju-Do as compared to that entering across other parts of the southern boundary. The Tsushima Current turns to the east, merges with the Cheju Current, and both the Cheju and Tsushima Current exit to the East Sea through the western channel of the Korea Strait. An intensification of the outflow occurs over the deep trough adjacent to the Tsushima Island, which appears to be due to the formation of the frictional boundary layer in order to remove excess positive relative vorticity generated by an increase in the layer thickness. The circulation driven by both the tidal and inflows/outflows is different from that driven by each forcing separately in coastal areas, which implies that both forcings should be considered simultaneously in the simulation of more realistic coastal circulation.

  • PDF

Long-term clinical and experimental/surface analytical studies of carbon/carbon maxillofacial implants

  • Szabo, Gyorgy;Barabas, Jozsef;Bogdan, Sandor;Nemeth, Zsolt;Sebok, Bela;Kiss, Gabor
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.37
    • /
    • pp.34.1-34.14
    • /
    • 2015
  • Background: Over the past 30-40 years, various carbon implant materials have become more interesting, because they are well accepted by the biological environment. The traditional carbon-based polymers give rise to many complications. The polymer complication may be eliminated through carbon fibres bound by pyrocarbon (carbon/carbon). The aim of this study is to present the long-term clinical results of carbon/carbon implants, and the results of the scanning electron microscope and energy dispersive spectrometer investigation of an implant retrieved from the human body after 8 years. Methods: Mandibular reconstruction (8-10 years ago) was performed with pure (99.99 %) carbon implants in 16 patients (10 malignant tumours, 4 large cystic lesions and 2 augmentative processes). The long-term effect of the human body on the carbon/carbon implant was investigated by comparing the structure, the surface morphology and the composition of an implant retrieved after 8 years to a sterilized, but not implanted one. Results: Of the 16 patients, the implants had to be removed earlier in 5 patients because of the defect that arose on the oral mucosa above the carbon plates. During the long-term follow-up, plate fracture, loosening of the screws, infection or inflammations around the carbon/carbon implants were not observed. The thickness of the carbon fibres constituting the implants did not change during the 8-year period, the surface of the implant retrieved was covered with a thin surface layer not present on the unimplanted implant. The composition of this layer is identical to the composition of the underlying carbon fibres. Residual soft tissue penetrating the bulk material between the carbon fibre bunches was found on the retrieved implant indicating the importance of the surface morphology in tissue growth and adhering implants. Conclusions: The surface morphology and the structure were not changed after 8 years. The two main components of the implant retrieved from the human body are still carbon and oxygen, but the amount of oxygen is 3-4 times higher than on the surface of the reference implant, which can be attributed to the oxidative effect of the human body, consequently in the integration and biocompatibility of the implant. The clinical conclusion is that if the soft part cover is appropriate, the carbon implants are cosmetically and functionally more suitable than titanium plates.

A Study on the Improvement of the Electrochemical Performance of Graphite Anode by Controlling Properties of the Coating Pitch (코팅 피치의 물성제어를 통한 흑연 음극재의 전기화학 성능 향상 연구)

  • Kim, Bo Ra;Kim, Ji Hong;Kang, Seok Chang;Im, Ji Sun
    • Applied Chemistry for Engineering
    • /
    • v.33 no.5
    • /
    • pp.459-465
    • /
    • 2022
  • A pitch coating method was proposed for the purpose of improving the electrochemical properties of natural graphite. The synthesis conditions of pitch coating were optimized via measuring electrochemical properties of pitch-coated graphite anodes. As the synthesis temperature increased, the thermal stability was improved in addition to an increase in the softening point and residual carbon weight. However, the synthesis temperature of 430 ℃ resulted in the synthesis of a large amount of NI (NMP Insoluble) due to excessive condensation reaction. As the surface uniformity and coating thickness increased due to high thermal stability, the initial coulombic efficiency and rate capability of the pitch-coated graphite were improved. However, the graphite coated with the pitch containing excessive NI showed lower electrochemical properties than the uncoated graphite. NI had low dispersibility and formed spheres after heat treatment, so it formed the heterogeneous and thicker SEI layer. The optimum conditions for forming a uniform surface and an appropriate coating layer were investigated.

Property of Nickel Silicide with 60 nm and 20 nm Hydrogenated Amorphous Silicon Prepared by Low Temperature Process (60 nm 와 20 nm 두께의 수소화된 비정질 실리콘에 따른 저온 니켈실리사이드의 물성 변화)

  • Kim, Joung-Ryul;Park, Jong-Sung;Choi, Young-Youn;Song, Oh-Sung
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.6
    • /
    • pp.528-537
    • /
    • 2008
  • 60 nm and 20 nm thick hydrogenated amorphous silicon(a-Si:H) layers were deposited on 200 nm $SiO_2$/single-Si substrates by inductively coupled plasma chemical vapor deposition(ICP-CVD). Subsequently, 30 nm-Ni layers were deposited by an e-beam evaporator. Finally, 30 nm-Ni/(60 nm and 20 nm) a-Si:H/200 nm-$SiO_2$/single-Si structures were prepared. The prepared samples were annealed by rapid thermal annealing(RTA) from $200^{\circ}C$ to $500^{\circ}C$ in $50^{\circ}C$ increments for 40 sec. A four-point tester, high resolution X-ray diffraction(HRXRD), field emission scanning electron microscopy(FE-SEM), transmission electron microscopy(TEM), and scanning probe microscopy(SPM) were used to examine the sheet resistance, phase transformation, in-plane microstructure, cross-sectional microstructure, and surface roughness, respectively. The nickel silicide from the 60 nm a-Si:H substrate showed low sheet resistance from $400^{\circ}C$ which is compatible for low temperature processing. The nickel silicide from 20 nm a-Si:H substrate showed low resistance from $300^{\circ}C$. Through HRXRD analysis, the phase transformation occurred with silicidation temperature without a-Si:H layer thickness dependence. With the result of FE-SEM and TEM, the nickel silicides from 60 nm a-Si:H substrate showed the microstructure of 60 nm-thick silicide layers with the residual silicon regime, while the ones from 20 nm a-Si:H formed 20 nm-thick uniform silicide layers. In case of SPM, the RMS value of nickel silicide layers increased as the silicidation temperature increased. Especially, the nickel silicide from 20 nm a-Si:H substrate showed the lowest RMS value of 0.75 at $300^{\circ}C$.