• Title/Summary/Keyword: residual capacity

Search Result 478, Processing Time 0.022 seconds

Correlation of Tracheal Cross-sectional Area with Parameters of Pulmonary Function in COPD (만성 폐쇄성 폐질환에서 기관의 단면적과 폐기능지표와의 상관관계)

  • Lee, Chan-Ju;Lee, Jae-Ho;Song, Jae-Woo;Yoo, Chul-Gyu;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo;Chung, Hee-Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.5
    • /
    • pp.628-635
    • /
    • 1999
  • Background : Maximal expiratory flow rate is determined by the size of airway, elastic recoil pressure and the collapsibility of airway in the lung. The obstruction of expiratory flow is one of the major functional impairments of emphysema, which represents COPD. Nevertheless, expiratory narrowing of upper airway may be recruited as a mechanism for minimizing airway collapse, and maintaining lung volume and hyperinflation by an endogenous positive end-expiratory pressure in patients with airflow obstruction. We investigated the physiologic role of trachea in respiration in emphysema. Method : We included 20 patients diagnosed as emphysema by radiologic and physiologic criteria from January to August in 1997 at Seoul Municipal Boramae Hospital. Chest roentgenogram, high resolution computed tomography(HRCT), and pulmonary function tests including arterial blood gas analysis and body plethysmography were taken from each patient. Cross-sectional area of trachea was measured according to the respiratory cycle on the level of aortic arch by HRCT and calibrated with body surface area. We compared this corrected area with such parameters of pulmonary function tests as $PaCO_2$, $PaO_2$, airway resistance, lung compliance and so on. Results : Expiratory cross-sectional area of trachea had significant correlation with $PaCO_2$ (r=-0.61, p<0.05), $PaO_2$ (r=0.6, p<0.05), and minute ventilation (r=0.73, p<0.05), but inspiratory cross-sectional area did not (r=-0.22, p>0.05 with $PaCO_2$, r=0.26, p>0.05 with $PaO_2$, and r=0.44, p>0.05 with minute ventilation). Minute ventilation had significant correlation with tidal volume (r=0.45, p<0.05), but it had no significant correlation with respiratory frequency (r=-0.31, p>0.05). Cross-sectional area of trachea had no significant correlation with other parameters of pulmonary function including $FEV_1$, FVC, $FEV_1$/FVC, peak expiratory flow, residual volume, diffusing capacity, airway resistance, and lung compliance, whether the area was expiratory or inspiratory. Conclusion : Cross-sectional area of trachea narrowed during expiration in emphysema, and its expiratory area had significant correlation with $PaCO_2$, $PaO_2$, and minute ventilation.

  • PDF

Quality Characteristics of Emulsion-Type Sausage Containing Pine Needle, Perilla Leaves and Green Tea Powder (솔잎, 깻잎 및 녹차분말이 함유된 유화형 소시지 품질특성)

  • Kim, I.K.;Jin, S.K.;Hah, K.H.;Lyou, H.J.;Park, K.H.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.4
    • /
    • pp.667-678
    • /
    • 2005
  • This study was carried out to investigate the effects of addition of functional material(T1; pine needle powder, 0.4%, T2; perilla leaves powder, 0.4%, T3; green tea powder, 0.4%) on the quality characteristics of emulsion-type sausages. The samples were stored at $9{\pm}1^{\circ}C$ for 40 days and analyzed with an interval of 10 days. The pH of all emulsion-type sausages increased as storage period increased. Water holding capacity(WHC) of all treatments were slightly increased as storage period increased and rapidly decreased on 40 days of storage. In texture analysis, hardness, chewiness, gumminess and brittleness were increased with storage in all treatments group. TBARS values of T3 was lower than those of other treatments at 1 days of storage, while that was the slightly higher in T4 at 40 day of storage. The L* values was decreased as storage period increased. The a* values was highest in C, while it was the lowest in T2 and T3. The residual nitrite content of all samples were in very safe range during the whole storage period. During the storage period 40 days, the Lactobacilli spp. of C were higher($10^7$CFU/g) than those of 3 treatments. In sensory evaluation, the score of overall acceptability were higher in the order of C(5.5-6.5)>T1(4.8-6.0)>T2(4.8-5.8)>T3(4.3-4.8). In the manufacture of functional sausage containing pine needle, perilla leaves and green tea powder, further studied are needs on addition type/ratio of functional materials and the use of added spices.

On decrease program of Radioactive Wastewater and Sewages in High Dose Radioiodine Therapy Ward (고용량 방사성옥소 치료병실의 오.폐수 저감화를 위한 연구)

  • Ryu, Jae-Kwang;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.19-26
    • /
    • 2008
  • Purpose: In general, We discharged radioactive wastewater and sewages less than $8.1{\times}10^{-13}$ Ci/ml in a exclusive water-purifier tank. Our hospital operating three exclusive water-purifier tank for radioactive wastewater and sewages of 60 tons capacity respectively. In order to meet the criteria it need a enough decay more than 125 days per each exclusive tank. However, recently we fell into the serious situation that decay period was decreased remarkably, owing to the wastewater amount increased rapidly by enlarge the therapy ward. For that reason, in this article, I'd like to say the way that reducing of radioactive wastewater and sewages rationally. Materials and Methods: From January, 2006 to October, four hundred and two cases were analyzed. They were all hospitalized during 3 days and 2 nights. We calculated the average amount of water used (include toilet water used, shower water used, washstand water used, $\cdots$), each exclusive water-purifier tank's decay period, as well as try to search the increased factors about water-purifier tank inflow flux by re-analysis of the procedure of radioisotope therapy step by step. Results: We could increase each exclusive water-purifier tank's decay period from 84 days to 130 days through the improvement about following cause: (1) Improvement of conventional toilet stool for excessive water waste $\rightarrow$ Replacement of water saving style toilet stool (2) Prevention of unnecessary shower and wash (3) Stop the diuretics taking during hospitalization (4) Analysis of relationship between water intakes and residual dose of body (5) Education about outside toilet utilization before the administration (6) Changed each water-purifier tank's maximum level from85% to 90% Conclusion: The originality of our efforts are not only software but hardware performance improvements. Incidentally the side of software's are change of therapy procedures and protocols, the side of hardware's are replacement of water saving style toilet stool and change of each water-purifier tank's maximum level. Thus even if a long lapse of time, problem such as return to the former conditions may not happen. Besides, We expect that our trials become a new reasonable model in similar situation.

  • PDF

Behavior of Hollow Box Girder Using Unbonded Compressive Pre-stressing (비부착 압축 프리스트레싱을 도입한 중공박스 거더의 거동)

  • Kim, Sung Bae;Kim, Jang-Ho Jay;Kim, Tae Kyun;Eoh, Cheol Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.3A
    • /
    • pp.201-209
    • /
    • 2010
  • Generally, PSC girder bridge uses total gross cross section to resist applied loads unlike reinforced concrete member. Also, it is used as short and middle span (less than 30 m) bridges due to advantages such as ease of design and construction, reduction of cost, and convenience of maintenance. But, due to recent increased public interests for environmental friendly and appearance appealing bridges all over the world, the demands for longer span bridges have been continuously increasing. This trend is shown not only in ordinary long span bridge types such as cable supported bridges but also in PSC girder bridges. In order to meet the increasing demands for new type of long span bridges, PSC hollow box girder with H-type steel as compression reinforcements is developed for bridge with a single span of more than 50 m. The developed PSC girder applies compressive prestressing at H-type compression reinforcements using unbonded PS tendon. The purpose of compressive prestressing is to recover plastic displacement of PSC girder after long term service by releasing the prestressing. The static test composed of 4 different stages in 3-point bending test is performed to verify safety of the bridge. First stage loading is applied until tensile cracks form. Then in second stage, the load is removed and the girder is unloaded. In third stage, after removal of loading, recovery of remaining plastic deformation is verified as the compressive prestressing is removed at H-type reinforcements. Then, in fourth stage, loading is continued until the girder fails. The experimental results showed that the first crack occurs at 1,615 kN with a corresponding displacement of 187.0 mm. The introduction of the additional compressive stress in the lower part of the girder from the removal of unbonded compressive prestressing of the H-type steel showed a capacity improvement of about 60% (7.7 mm) recovery of the residual deformation (18.7 mm) that occurred from load increase. By using prestressed H-type steel as compression reinforcements in the upper part of cross section, repair and rehabilitation of PSC girders are relatively easy, and the cost of maintenance is expected to decrease.

Behavior Analysis of Concrete Structure under Blast Loading : (II) Blast Loading Response of Ultra High Strength Concrete and Reactive Powder Concrete Slabs (폭발하중을 받는 콘크리트 구조물의 실험적 거동분석 : (II) 초고강도 콘크리트 및 RPC 슬래브의 실험결과)

  • Yi, Na Hyun;Kim, Sung Bae;Kim, Jang-Ho Jay;Cho, Yun Gu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.565-575
    • /
    • 2009
  • In recent years, there have been numerous explosion-related accidents due to military and terrorist activities. Such incidents caused not only damages to structures but also human casualties, especially in urban areas. To protect structures and save human lives against explosion accidents, better understanding of the explosion effect on structures is needed. In an explosion, the blast load is applied to concrete structures as an impulsive load of extremely short duration with very high pressure and heat. Generally, concrete is known to have a relatively high blast resistance compared to other construction materials. However, normal strength concrete structures require higher strength to improve their resistance against impact and blast loads. Therefore, a new material with high-energy absorption capacity and high resistance to damage is needed for blast resistance design. Recently, Ultra High Strength Concrete(UHSC) and Reactive Powder Concrete(RPC) have been actively developed to significantly improve concrete strength. UHSC and RPC, can improve concrete strength, reduce member size and weight, and improve workability. High strength concrete are used to improve earthquake resistance and increase height and bridge span. Also, UHSC and RPC, can be implemented for blast resistance design of infrastructure susceptible to terror or impact such as 9.11 terror attack. Therefore, in this study, the blast tests are performed to investigate the behavior of UHSC and RPC slabs under blast loading. Blast wave characteristics including incident and reflected pressures as well as maximum and residual displacements and strains in steel and concrete surface are measured. Also, blast damages and failure modes were recorded for each specimen. From these tests, UHSC and RPC have shown to better blast explosions resistance compare to normal strength concrete.

Optimization and Stabilization of Automated Synthesis Systems for Reduced 68Ga-PSMA-11 Synthesis Time (68Ga-PSMA-11 합성 시간 단축을 위한 자동합성장치의 최적화 및 안정성 연구)

  • Ji hoon KANG;Sang Min SHIN;Young Si PARK;Hea Ji KIM;Hwa Youn JANG
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.56 no.2
    • /
    • pp.147-155
    • /
    • 2024
  • Gallium-68-prostate-specific membrane antigen-11 (68Ga-PSMA-11) is a positron emission tomography radiopharmaceutical that labels a Glu-urea-Lys-based ligand with 68Ga, binding specifically to the PSMA. It is used widely for imaging recurrent prostate cancer and metastases. On the other hand, the preparation and quality control testing of 68Ga-PSMA-11 in medical institutions takes over 60 minutes, limiting the daily capacity of 68Ge/68Ga generators. While the generator provides 1,110 MBq (30 mCi) nominally, its activity decreases over time, and the labeling yield declines irregularly. Consequently, additional preparations are needed, increasing radiation exposure for medical technicians, prolonging patient wait times, and necessitating production schedule adjustments. This study aimed to reduce the 68Ga-PSMA-11 preparation time and optimize the automated synthesis system. By shortening the reaction time between 68Ga and the PSMA-11 precursor and adjusting the number of purification steps, a faster and more cost-effective method was tested while maintaining quality. The final synthesis time was reduced from 30 to 20 minutes, meeting the standards for the HEPES content, residual solvent EtOH content, and radiochemical purity. This optimized procedure minimizes radiation exposure for medical technicians, reduces patient wait times, and maintains consistent production schedules, making it suitable for clinical application.

Relationship of Compliance and Oxygen Transport in Experimental Acute Respiratory Failure during Positive End-Expiratory Pressure Ventilation (실험적 급성호흡부전에서 호기말양압에 의한 폐유순도와 산소운반의 변화 및 상관관계 - 호흡부전의 기전에 따른 차이 -)

  • Lee, Sang-Do;Yoon, Se-Jin;Lee, Bok-Hee;Han, Sung-Koo;Shim, Young-Soo;Kim, Keun-Youl;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.1
    • /
    • pp.6-15
    • /
    • 1993
  • Background: Positive end, expiratory pressure (PEEP) has become one of the standard therapies for adult respiratory distress syndrome (ARDS). Total static compliance has been proposed as a guide to determine the size of PEEP ('best PEEP') which is of unproven clinical benefit and remains controversial. Besides increasing functional residual capacity and thus improving oxygenation, PEEP stimulate prostacyclin secretion and was proposed for the treatment of acute pulmonary embolism. But little is known about the effect of PEEP on hemodynamic and gas exchange disturbances in acute pulmonary embolism. Methods: To study the validity of total static compliance as a predictor of 'best PEEP' in ARDS and acute pulmonary embolism, experimental ARDS was induced in mongrel dog with oleic acid and acute pulmonary embolism with autologous blood clot. Then hemodynamic and gas exchange parameters were measured with serial increment of PEEP. Results:In ARDS group, total static compliance and oxygen transport were maximal at 5 cm$H_2O$, and decreased thereafter (p<0.05). With increment of PEEP, arterial oxygen tension ($PaO_2$) and arterial carbon dioxide tension ($PaCO_2$) increased and cardiac output and physiological shunt decreased. In pulmonary embolism group, total static compliance, oxygen transport, physiological shunt and cardiac output decreased and $PaO_2$ and $PaCO_2$ increased with increment of PEEP (p<0.05). Comparing the change induced by increment of PEEP by 1 cm$H_2O$ in ARDS group with that in pulmonary embolism group, there was no significant difference between two groups except cardiac output which decreased more in pulmonary embolism group (p<0.05). In ARDS group, oxygen transport and total static compliance increased after PEEP application, and total static compliance was maximal at the PEEP level where oxygen transport was maximal. However in pulmonary embolism group, oxygen transport and total static compliance decreased after application of PEEP. There was significant correlation between change of total static compliance and change of oxygen transport in both groups. Conclusion: In both ARDS and acute pulmonary embolism, it can be concluded that total static compliance is useful as a predictor of 'best PEEP'.

  • PDF

A study on the factors to affect the career success among workers with disabilities (지체장애근로자의 직업성공 요인에 관한 연구)

  • Lee, Dal-Yob
    • 한국사회복지학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.185-216
    • /
    • 2003
  • This study was aimed at investigating important factors influencing career success among regular workers. The current researcher scrutinized the degree to which variables and factors affect the career success and occupational turnover rates of the research participants. At the same tune, two hypothetical path models established by the researcher were examined using linear multiple regression methods and the LISREL. After examining the differences among the factors of career success, a comparison was made between the disabled worker group and the non-disabled worker group. A questionnaire using the 5-point Likert scale was distributed to a group of 374 workers with disabilities and 463 workers without disabilities. For the data analysis purpose, the structural equation model, factor analysis, correlation analysis, and multiple regression analysis were carried out. The results of this study ran be summarized as follows. First, the results of factor analysis showed important categories of conceptual themes of career success. The initial conceptual factor model did not accord with the empirical one. A three-factorial model revealed categories of personal, family, and organizational factor respectively. The personal factor was composed of the self-esteem and self-efficiency. The family factor was consisted of the multi-roles stress and the number of children. Finally, the organizational factor was composed of the capacity for utilizing resources, networking, and the frequency of mentoring. In addition, the total 10 sub areas of career success were divided by two important aspects; the subjective career success and the objective career success. Second, both research participant groups seemed to be influenced by their occupational types. However, all predictive variables excluding the wage rate and the average length of work years had significant impact on job success for the disabled work group, while all the variables excluding the frequency of advice and length of working years had significant impact on job success for the non-disabled worker group. Third, the turnover rate was significantly influenced by the age and the experience of turnover of the research participants. However, the number of co-workers was the strongest predictive variable for the worker group with disabilities, but the occupation choice variable for the worker group without disabilities. For the disabled worker group, the turnover rate was differently influenced by the type of occupation, the length of working years, while multi-role stress and the average working years at the time of turnover for the worker group without disabilities. Fifth, as a result of verifying the hypothetical path model, it showed that the first model was somewhat proper and could predict the career success on both research participant groups. In the second model, the Chi-square, the degree of freedom (($x^2=64.950$, df=61, P=0.341), and the adjusted Goodness of Fit Index (AGFI) were .964, and the Comparative Fit Index (CFI) were .997, and the Root Mean Squared Residual (RMR) was respectively. .038. The model was best fitted and could predict the career success more highly because the goodness of fit index in the whole models was within the allowed range. In conclusion, the following research implications can be suggested. First, the occupational type of research participants was one of the most important variables to predict the career success for both research participant groups. It means that people with disabilities require human development services including education. They need to improve themselves in this knowledge-based society. Furthermore, for maintaining the career success, people with disabilities should be approached by considering the subjective career success aspects including wages and the promotion opportunities than the objective career success aspects.

  • PDF