• Title/Summary/Keyword: residential-commercial building

Search Result 154, Processing Time 0.028 seconds

Structural Design of Mid-Story SI Tall-building with RC Frame Placed on Steel Structure

  • Isobe, Tomonobu;Aono, Hideshi
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.3
    • /
    • pp.173-178
    • /
    • 2021
  • In this paper we introduce Shinagawa HEART, located in Shinagawa district, Tokyo. It is a mixed-use building with residences on the upper floors, offices on the lower floors, and commercial uses on the first and second floors, and is intended to meet the various needs of a building on the border between residential and commercial areas. The upper floors of the building are made of reinforced concrete, while the middle and lower floors are made of steel with CFT columns. First, an overview of the structural plan of the building is presented. Next, the adoption of the middle layer seismic isolation and the switch between the lower steel structure and the upper reinforced concrete structure, which are the features of this building, are explained. Finally, the construction method adopted to achieve the design performance is explained.

The Regionally Specific Residential Characteristics of ′Residential-Commercial Mixed Use Buildings′ in Seoul (서울시 주상복합건물의 지역별 주거 특성)

  • 정은진
    • Journal of the Korean Geographical Society
    • /
    • v.38 no.5
    • /
    • pp.741-753
    • /
    • 2003
  • This study begins with paying attention to the agglomeration of 'Residential-Commercial Mixed Use Buildings(hereafter, R-C MU Buildings)', which tend to be a high grade and large sized building cluster at various neighboring areas in Seoul. The purpose of this study is to understand the relationship between emerging new housing type and residential area by analyzing the characteristics of residential neighborhood that is mainly created by R-C MU Buildings. For this purpose, the specialization and the regional characteristics(in connection with the hierarchy in urban spatial structure) of R-C MU Building's residential neighborhood were analyzed. In the end, the specific type of housing reveals the tendency to be differentiated in terms of income, education and occupation related with housing and residential area. And the residential characteristics also seem to be different according to the regions based on the central place hierarchical structure. It means that the social and class factors are important in choosing house, but the characteristics of the neighborhood area play an important role in the selection of resident area. Finally, the location of certain type of housing can influence the selecting process of residence and it can also determine the characteristics of the resident area in turn.

A Study on the SCW Ground Source Heat Pump System Technologies for Residential Cluster Homes (수주지열정 지열원 열펌프 시스템의 집단주거시설 적용을 위한 기반 기술 분석)

  • Lee, Kwang Ho;Do, Sung Lok;Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.3
    • /
    • pp.14-20
    • /
    • 2019
  • In this study, the technologies and regulations for distributing standing column well(SCW) ground source heat pump systems to the residential cluster homes were investigated. They have only been installed in the public or commercial building having different load pattern and site structure compared with the residential cluster homes. Some of SCWs for the residential cluster homes should be installed under the basement due to a lack of site area. There are pressure differences between the SCWs installed under ground surface and basement. It is needed to develop the technology or devices to prevent overflow caused by pressure difference among the SCWs. In addition, heat balance algorithm between SCWs should be adopted to maximize the system efficiency. A heat pump having heating, cooling, hot water, heating-hot water, and cooling-hot water modes should be developed for adopting an individual air-conditioning system to the residential cluster homes.

Development of a Novel Air-Conditioning Method for Energy Savings in Commercial Building Under Time of Use Electricity Pricing (계시별 전기 요금제하의 에너지 절약을 위한 건물 냉방 제어 방법의 개발)

  • Noh, Sung-Jun;Jeon, Jeong-Pyo;Kim, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.164-170
    • /
    • 2013
  • The commercial buildings are consuming about 30% of total energy used in Korea. And a large amount of energy consumption in commercial buildings is consumed by HVAC(Heating, Ventilation, Air Conditioning) system. Therefore, if we can reduce the energy consumption in HVAC or air-conditioning system in commercial buildings, the overall energy consumption in Korea can be reduced. Currently, an electricity charge called Time of Use (TOU) is applied to typical commercial buildings. This paper proposes the novel energy management method where the temperature setting of air-conditioning system are adjusted to minimize the use of electrical energy while indoor comfort level is retained. The simulation test for a typical commercial building shows that the proposed method gives over 10% savings in electricity bills and electricity consumption compared to the conventional air-conditioning method.

The Novel Configuration of Integrated Network for Building Energy System (빌딩 에너지시스템 통합네트워크 구축에 관한 연구)

  • Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.229-234
    • /
    • 2008
  • The new millennium has started with several innovations driven by fast evolution of the technologies in energy sector. A strong impulse towards the diffusion of new economical efficient technologies regulatory incentives related to energy production from renewable source and a small scale building trigeneration and to promotion of more sustainable environmental-friendly generation solutions, the evolution of electricity markets, more and more binding local emission constraints, and the need for improving the security of supply to reduce the energy system vulnerability. The 24 percentage energy quantify of total energy consumption consumes in commercial buildings and residential houses and the 30% portion of total $CO_2$ emissions covers also in the commercial buildings and residential houses sector. To cope with efficiently this energy sinuation in building sector, Building microgrid or building tooling, heating & power(BCHP) system has been interested in recent day due to meeting thermal and electric energy requirements efficiently and with appropriate energy quality. A multi agent system is a collective of intelligent agents that communicate with each other and work cooperatively to achieve common goals. Also, it is to medicate and coordinate communication between Control Areas and Security Coordinators for teal-time control of the BCHP system and the power pid. In this new circumstance, it is very important to integrate the power and energy delivery system and the information system(communication, networks, and intelligent equipment) that controls it. Therefore, development of smart control modules with open communication protocol and seamlessly interchange the data and information between control network and data network including extranet and intranet give a great meanings. We designed and developed the TCP/IP-CAN IED agent modules and ModBus./LonTalk/(TCP/IP) IED agent ones to configure the multi-agent system based smart energy network of commercial buildings and also intelligent algorithms for inverter fault diagnostics which ran be operated in control level or agent level network.

  • PDF

The ASHRAE Design Guide for Tall, Supertall and Megatall Building Systems

  • Simmonds, Peter
    • International Journal of High-Rise Buildings
    • /
    • v.4 no.4
    • /
    • pp.311-318
    • /
    • 2015
  • The ASHRAE Design Guide for Tall, Supertall and Megatall Building Systems was produced in collaboration with the CTBUH. The design guide outlines various tall building mechanical systems that are presently being designed or are planned for the future. Tall commercial buildings in particular present a series of design problems that set them apart from other functions. The Design Guide will be of interest to owners, architects, structural engineers, mechanical engineers, electrical engineers and other specialized engineers and consultants. This design guide addresses design issues for tall commercial buildings, which are very often mixed-use, and commonly consist of low level retail, office floors, residential units, and hotel uses.

A Comparative Study on the Horizontal Openness of High-rise Residential Buildings in terms of Building Arrangement Type - Focused on the Cases in Daegu - (상업지역 내 초고층 주거건축의 주동배치방식에 따른 수평적 개방성 비교연구 - 대구지역 사례 중심으로 -)

  • Kwon, Jong-Wook;Park, Sang-Min;Park, Byong-Han
    • Journal of the Korean housing association
    • /
    • v.23 no.3
    • /
    • pp.53-61
    • /
    • 2012
  • Openness to outside is one of the most critical advantages for high-rise buildings. However, the effect of openness can be decreased if it is blocked by other high-rise buildings, especially built within the building complex of commercial district. The purpose of this study is to identify the horizontal openness of high-rise residential buildings by comparing 3 different cases of building arrangement type. A new method of evaluation has been introduced on the basis of distance to measure the openness including the matter of securing privacy. As a result of this study, comparative analysis was possible and relatively plentiful results of analysis could be drawn out. Through the process of analysis, this study set the evaluation indicators suitable to the analysis of openness of unit households. Thereby, the results of this study are expected to be used as useful basic data in planning high-rise mixed-use buildings.

Efficient Analysis of Building Structures with a Rigid Floor System (주상복합건물의 효율적인 지진해석)

  • 황현식;이동근
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.1
    • /
    • pp.79-88
    • /
    • 1997
  • Very stiff floor system in a residential-commercial building causes some problems in the numerical analysis procedure due to significant difference in stiffness with adjacent elements. Static analysis of structure with a stiff transfer-floor can be performed approximately in two steps for upper and lower parts for the structure. However, it is impossible to perform dynamic analysis in two steps with separate models. An efficient method for dynamic analysis of a structure with a right floor system is proposd in this study. The matrix condensation technique is employed to reduce the degree of freedom for upper and lower parts of the structure and a beam elements with rigid bodies at both ends are introduce to model the rigid floor system. Efficiency and accuracy of the proposed method are verified through analysis of several example structures.

  • PDF

District Energy Use Patterns and Potential Savings in the Built Environment: Case Study of Two Districts in Seoul, South Korea

  • Lee, Im Hack;Ahn, Yong Han;Park, Jinsoo;Kim, Shin Do
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.1
    • /
    • pp.48-58
    • /
    • 2014
  • Energy efficiency is vital to improve energy security, environmental and social sustainability, and economic performance. Improved energy efficiency also mitigates climate change by lowering greenhouse gas (GHG) emissions. Buildings are the single largest industrial consumer of energy and are therefore key to understanding and analyzing energy consumption patterns and the opportunities for saving energy at the district level in urban environments. This study focused on two representative boroughs in the major metropolitan area of Seoul, South Korea as a case study: Gandong-gu, a typical residential district, and Jung-gu, a typical commercial district. The sources of the energy supplied to the boroughs were determined and consumption patterns in different industry sectors in Seoul used to identify current patterns of energy consumption. The study analyzed the energy consumption patterns for five different building categories and four different sectors in the building using a bottom-up energy modeling approach. Electricity and gas consumption patterns were recorded for different building categories and monthly ambient temperatures in the two boroughs. Finally, a logarithmic equation was developed to describe the correlation between commercial activity and cooling energy intensity in Jung-gu, the commercial district. Based on these results, recommendations are made regarding the current energy consumption patterns at the district level and government energy policies are suggested to reduce energy consumption and, hence, greenhouse gas emissions, in both commercial and residential buildings.

A Study on the Vitality of the Main Street in Urban Residential Estate (택지개발지구 중심가로 활성화에 관한 연구 - 대구광역시 사례를 중심으로 -)

  • 박선경;김혜경;하재명
    • Journal of the Korean housing association
    • /
    • v.14 no.2
    • /
    • pp.9-18
    • /
    • 2003
  • The vitality of a main street is essential to get the urbanity of the urban residential estates. The purpose of this study is to analyze the relationship between the vitality of a main street and street land uses in the residential estate. The outcomes of this study are as follows: first, the street land uses have influence on the vitality of a main street; the main streets with the small commercial and business facilities are more vitalized than those with the boundary wall of the residential building or the buffer zone. Second, the number of shops in street has positive influence on the vitality of a main street. Third, the vitality of a main street is effected by the entrance of apartment site.