• Title/Summary/Keyword: residential fire

Search Result 191, Processing Time 0.025 seconds

A Study on Reinforcement of Fire Safety in Residential Spaces of Low-Income Classes (저소득계층 주거 공간 화재안전성 강화를 위한 연구)

  • Park, Nam-Kwon
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.4
    • /
    • pp.882-889
    • /
    • 2021
  • Purpose: The purpose of this study was to improve fire safety in Gosiwon, a residential space for the low-income class. Method: Problems appearing in the process of fire occurrence and damage were verified once again. In addition, we would like to suggest improvement measures through systematic discussions on blind spots. Results: As a result of examining the risk of cool fire, the causes of fire occurred in various ways. In addition, the possibility of radiant heat due to heat accumulation due to narrow rooms inside the Gosiwon was high. Also, it was found that the possibility of fire spread was high due to clothing and household goods. It was reconfirmed that the poor internal structure of a narrow indoor space had a significant effect on the spread of fire and the scale of damage as it tried to accommodate as many people as possible inside. Conclusion: It is necessary to complete the installation as soon as possible for Gosiwon where the simple sprinkler is not installed. For this, a stronger driving force from the government and local governments is needed. In addition, it will be necessary to discuss how to improve the spatial and structural fire vulnerabilities that appear due to the structural characteristics of the Gosiwon.

Characterization of Live Fire Load in Buildings - Heat Release Characteristics of Typical Live Fire Load in Post Office Building - (건축물의 적재가연물 특성에 관한 연구 -우체국 적재가연물의 연소성상 -)

  • Nam, Dong-Gun;Yuji, Hasemi;SaKong, Seong-Ho;Jung, Jong-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.7-10
    • /
    • 2008
  • Heat release characteristics of live fire load are an important parameter for performance oriented fire safety design of a building. While investigations have been carried out on the fire load and its burning behavior in office, residential and commercial buildings and so on, little effort has been paid for the rational treatment of fire load in post office buildings in Japan. In this report, burning behavior of typical combustible objects in post office buildings are studied by measuring heat release rates of plastic palettes with and without postal envelopes or packages and special containers loading numbers of palettes. The test results suggest that dynamic heat release rate is highly dependent on the condition of palettes especially if they load appropriate amount of postal envelopes or not.

  • PDF

A Study on the Fire Safety Design and Predicting Fire Behavior Using Compartment Fire Test (단일화재실험을 통한 화재성상예측 및 건축구조물의 화재안전 설계에 관한 연구)

  • Yoon, Ung-Gi;Seo, Dong-Goo;Kim, Dong-Eun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.107-108
    • /
    • 2013
  • In this study, combustibles investigation and fire growth rate experiment were performed for predicting initial fire behavior in buildings. Combustibles investigation was performed for residential buildings, which is most frequently affected by fire in Korea. Spatial characteristics and combustibles properties were separately investigated, and occupied area and layout characteristics of combustibles were identified to produce general layout models. Of the layout models, room was selected for fire test of a single compartment. From this test, fire propagation for each combustible was identified, which was delayed compared to the summed heat release rate of a single combustible.

  • PDF

Evaluation on Residential Environment of Purchased Rental Housing (다가구 매입임대주택의 주거환경 실태 평가)

  • Cho, Seung-Yeoun;Kwon, Hyuk-sam;Hyun, Chang-guk;Cheong, Jae-Jin
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.4
    • /
    • pp.3-10
    • /
    • 2018
  • The purpose of this study is to evaluate the residential environment by indicators of internal and external conditions of Purchased Rental Housings (PRH). In this study, we conducted a field survey on 200 units of PRH to evaluate the residental environment located in Seoul, Incehon, Kyounggi, Daejeon, Busan and Daegu. As a result, the residential environment of PRH is managed as above average at most indicators. Partly parking areas and fire-fighting facilities are need to be improved for safety and health. It is considered that the political goal of PRH, such as housing safety and stability for low-income class, is achieved by decent housings and appropriate maintenance. However, it is still necessary to improve its management system for sustainable and safe residential environments.

Necessity for Performance Grade for Residential Structure Waterproofing based on Application Areas - Using AHP Methodology - (공동주택 방수 시공 부위에 따른 성능등급의 필요성 확인 - AHP 분석을 중심으로 -)

  • An, Ki-Won;Oh, Kyu-Hwan;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.21-22
    • /
    • 2021
  • Domestic residential buidling grading is currently comprised of 5 fields; sound-proofing, structure, ambient condition, living environment and fire-proofing. However, factors the take up most of the civil complaints are related to leakage, and waterproofing is not listed as part of the grading system. In particular, the Ministry of Land and Transport claims that the most crucial problems are leakage related in residential structures. Therefore, this study proposes to provide such grading system for waterproofing by AHP methodology based on waterproofing application locations in residential structures.

  • PDF

A investigation study on the Maintenance Management for Fire Safety According to Analysis of Fire Accident in Korea(I) (국내 지하공동구의 화재사례 분석을 통한 화재안전관리방안에 관한 조사 연구(I))

  • Kim, Dong-Eun;Shin, Yi-Chul;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.328-333
    • /
    • 2008
  • Underground utility tunnels are important facilities not only as an essential social infrastructure for modern information society but as the economic and efficient carrier of various urban infrastructure including electric power lines, communication cables, gas pipes, water supply and drainage pipes and energy supplies to metropolitan and residential areas. It is the aim of this study to investigation study on the Maintenance Management for Fire Safety According to Analysis of Fire Accident in Korea.

  • PDF

Statistical Analysis on the Structure of the Front Door in Apartment House (공동주택 세대 현관 방화문 구조에 관한 통계적 분석)

  • Shim, Han-Young;Park, Won-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.23-24
    • /
    • 2021
  • Since 2011, apartment houses account for about 41% of the fires in residential facilities for the past 10 years. Fire-resistant performance of fire doors is becoming more important to prevent the spread of fire in apartment houses. This research analyzed the structure of fire door through each 10 DB based on the quality inspection report of Continuous Acquisition & Life-cycle Support(CALS) from 2016 to 2020, which passed the fire performance test based on the laws and notices of domestic fire door. Therefore, based on the results of the analysis of DB in the future, we will conduct a study on structural improvement and addition for fireproof performance improvement of fire door.

  • PDF

A Study on the Fire Safety of High-rise Apartments Based on Fire Door Switch and Automatic Fire Extinguishing System

  • Zhang, ZeChen;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.424-430
    • /
    • 2021
  • The purpose of this study is to analyse the characteristics and spreading laws of parameters such as fire smoke, concentration of CO, visibility, and temperature at fire scene in high-rise residential buildings under the different conditions of fire doors and automatic fire extinguishing systems. Using Pyrosim to simulate diverse fire scenes in a high-rise apartment with corridors, to analyze the changes in those parameters. The results show that when a fire occurs, closing the fire-fighting corridor will increase the smoke temperature and concentration of CO in the stairwell, and reduce the height and visibility of the smoke layer; the automatic fire extinguishing system effectively suppresses the increase in the temperature of the fire smoke and the sedimentation of the smoke layer. Reasonable setting and operation of the automatic fire extinguishing system could effectively inhibit the spread of fire. Although closing fire corridor can slow down the direct upward spread of smoke through the corridor, it will force the fire smoke into the stairwell, which will seriously affect evacuation through the stairs. Therefore, in order to reduce risks, it is forbidden to close the fire doors of the firefighting corridor and stacking combustible materials in the corridor, Also, intensifying inspections and ensuring the normal operation of the automatic fire extinguishing system are indispensable. Based on the research results, the significance of installing fire-fighting facilities in the construction of high-rise apartments was discussed and proved.

A Study on the Analysis of Evacuation Risk by Building Application for Fire Safety (화재안전을 위한 건축물 용도별 피난리스크 분석에 관한 연구)

  • Jin, Seung-hyeon;Koo, In-Hyuk;Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.164-165
    • /
    • 2021
  • In Korea, in the case of fire scenarios in performance design, it is assumed that the sprinkler is not working. In addition, it does not applicate various fire conditions. Therefore it is not enough that the accuracy about fire scenario. In foreign countries, reseach is being conducted to predict the casualities that can occur due to fire in the building space through statistical risk analysis. Also, research is consistently conducting for design that consider the sprinker probability of operation. Therefore, to analyze the fire risk of each building in Korea, the risk was analyzed using statistical data. As a result, the risk of casualties that can occur for each building use was analyzed as 0.6(persons/cases) for residential buildings, 0.25(persons/cases) for sales facilities, and 0.12(persons/cases) for buisiness facilities.

  • PDF