• Title/Summary/Keyword: resident concentration

Search Result 59, Processing Time 0.021 seconds

COMPARISON OF FLUX AND RESIDENT CONCENTRATION BREAKTHROUGH CURVES (BTCs) IN STRUCTURED SOIL COLUMNS

  • Kim, Dong-Ju
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1997.05a
    • /
    • pp.25-29
    • /
    • 1997
  • In many solute transport studies, either flux or resident concentration has been used. Choice of the concentration mode was dependent on the monitoring device in solute displacement experiments. It would be questionable, however. to accept the equivalency in the solute transport parameters between flux and resident concentrations in structured soils exhibiting preferential movement of solute. In this study, we investigate how they differ in the monitored breakthrough curves (BTCs) and transport parameters for a given boundary and flow condition by performing solute displacement experiments on a number of undisturbed soil columns. Both flux and resident concentrations have been simultaneously obtained by monitoring the effluent and resistance of the Horizontally-positioned TDR probes. The study reveals that soil columns having relatively high flux densities exhibited great differences in the degree of peak concentration and travel time of peak between flux and resident concentrations. The peak concentration in flux mode was several times higher than that in resident one. This was mainly due to the bypassing of solute through soil macropores.

  • PDF

COMPARISON OF FLUX AND RESIDENT CONCENTRATION BREAKTHROUGH CURVES IN STRUCTURED SOIL COLUMNS (구조토양에서의 침출수와 잔존수농도의 파과곡선에 관한 비교연구)

  • Kim, Dong-Ju
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.2
    • /
    • pp.81-94
    • /
    • 1997
  • In many solute transport studies, either flux or resident concentration has been used. Choice of the concentration mode was dependent on the monitoring device in solute displacement experiments. It has been accepted that no priority exists in the selection of concentration mode in the study of solute transport. It would be questionable, however, to accept the equivalency in the solute transport parameters between flux and resident concentrations in structured soils exhibiting preferential movement of solute. In this study, we investigate how they differ in the monitored breakthrough curves (BTCs) and transport parameters for a given boundary and flow condition by performing solute displacement experiments on a number of undisturbed soil columns. Both flux and resident concentrations have been simultaneously obtained by monitoring the effluent and resistance of the horizontally-positioned TDR probes. Two different solute transport models namely, convection-dispersion equation (CDE) and convective lognormal transfer function (CLT) models, were fitted to the observed breakthrough data in order to quantify the difference between two concentration modes. The study reveals that soil columns having relatively high flux densities exhibited great differences in the degree of peak concentration and travel time of peak between flux and resident concentrations. The peak concentration in flux mode was several times higher than that in resident one. Accordingly, the estimated parameters of flux mode differed greatly from those of resident mode and the difference was more pronounced in CDE than CLT model. Especially in CDE model, the parameters of flux mode were much higher than those of resident mode. This was mainly due to the bypassing of solute through soil macropores and failure of the equilibrium CDE model to adequate description of solute transport in studied soils. In the domain of the relationship between the ratio of hydrodynamic dispersion to molecular diffusion and the peclet number, both concentrations fall on a zone of predominant mechanical dispersion. However, it appears that more molecular diffusion contributes to the solute spreading in the matrix region than the macropore region due to the nonliearity present in the pore water velocity and dispersion coefficient relationship.

  • PDF

Application of an Automated Time Domain Reflectometry to Solute Transport Study at Field Scale: Transport Concept (시간영역 광전자파 분석기 (Automatic TDR System)를 이용한 오염물질의 거동에 관한 연구: 오염물질 운송개념)

  • Kim, Dong-Ju
    • Economic and Environmental Geology
    • /
    • v.29 no.6
    • /
    • pp.713-724
    • /
    • 1996
  • The time-series resident solute concentrations, monitored at two field plots using the automated 144-channel TDR system by Kim (this issue), are used to investigate the dominant transport mechanism at field scale. Two models, based on contradictory assumptions for describing the solute transport in the vadose zone, are fitted to the measured mean breakthrough curves (BTCs): the deterministic one-dimensional convection-dispersion model (CDE) and the stochastic-convective lognormal transfer function model (CLT). In addition, moment analysis has been performed using the probability density functions (pdfs) of the travel time of resident concentration. Results of moment analysis have shown that the first and second time moments of resident pdf are larger than those of flux pdf. Based on the time moments, expressed in function of model parameters, variance and dispersion of resident solute travel times are derived. The relationship between variance or dispersion of solute travel time and depth has been found to be identical for both the time-series flux and resident concentrations. Based on these relationships, the two models have been tested. However, due to the significant variations of transport properties across depth, the test has led to unreliable results. Consequently, the model performance has been evaluated based on predictability of the time-series resident BTCs at other depths after calibration at the first depth. The evaluation of model predictability has resulted in a clear conclusion that for both experimental sites the CLT model gives more accurate prediction than the CDE model. This suggests that solute transport at natural field soils is more likely governed by a stream tube model concept with correlated flow than a complete mixing model. Poor prediction of CDE model is attributed to the underestimation of solute spreading and thus resulting in an overprediction of peak concentration.

  • PDF

Key Parameters Analysis of Important Radionuclides in Dose Evaluation Model of Decommissioning Site (해체 부지 선량평가모텔의 주요 핵종에 대한 Key parameter 분석)

  • 임용규;김학수;손중권;박경록;강기두;김경덕;정찬우
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.52-57
    • /
    • 2004
  • In order to analyze key parameters of important radionuclides in dose evaluation model of decommissioning site, a sensitivity analysis was performed. This analysis assumed a resident farmer for an exposure scenario and 0.037Bq/g for the concentration of radionuclides. As a result of sensitivity analysis, the key parameters of radionuclides considered were the area of contaminated zone, external gamma shielding factor and indoor time fraction for Cs-137 and Co-60. The key parameters for C-14 were the environmental parameters and hydrological parameters of unsaturated zone. Also, the key parameter for Sr-90 was the density of contaminated zone.

  • PDF

A Study on Concentration Change of Volatile Organic Compounds; VOCs by using Mock-up Test (실물실험을 통한 개별 VOC의 농도변화에 관한 연구)

  • Kim Chang-Nam;Lee Yun-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.487-495
    • /
    • 2005
  • Recently, due to the airtightness of buildings or the misuse of building materials, we have been witness SHS (Sick House Syndrome) which can have bad influences on the resident in an existing apartment house as well as newly constructed apartment house start to attract public attention. As a result of this situation, we went to restrict the TVOC (Total Volatile Organic Compound) and formaldehyde. But these guidelines concentrated on only TVOC although TVOC are consist of many individual VOC. Therefore, in this study, we will look about concentration change of VOCs (Volatile Organic Compounds) by using Mock-up test. As result of test, the concentration of four individual VOC (Benzene, Toluene, Ethylbenzene, Styrene) showed quitely low level after 7 days. On the other hand the concentration of Xylene and formaldehyde showed low level after 14 days.

Rheological Studies of Greases (潤滑油의 粘性學的 硏究)

  • Shao Mu Ma;Tai Kyu Ree
    • Journal of the Korean Chemical Society
    • /
    • v.20 no.3
    • /
    • pp.173-184
    • /
    • 1976
  • A steel capillary viscometer was built for the study of rheological properties of greases. Bentone greases with thickener concentration of 2.0, 4.0, 6.0, 8.0, and 10.0 weight percent and lime-soap greases with soap concentrations of 2.4, 7.0, 9.3, 12.1 and 15.2 weight percent were studied. Capillaries with various radii R and lengths L were used to study the resident-time effect on the flow properties of lime soap greases. Detailed studies on bentone greases were conducted using a capillary with a fixed size. The results were analyzed by using Ree-Eyring flow equation. The factors appearing in the latter, ($X_1{\beta}_1/{\alpha}_1$ for Newtonian units, $X_2/{\alpha}_2$ and ${\beta}_2$ both for non-Newtonian units), were studied in order to investigate how they change with thickener concentrations and temperatures. Through this analysis, we have found that TEX>${\Delta}H_1^{\neq}$ and ${\Delta}H_2^{\neq}$, the activation enthalpies for flow of type-1 unit and of type-2 unit, respectively, are approximately equal to that of the base oil, the solvent. From this fact, it is concluded that these type units flow into the holes which were produced by the movement of solvent molecules. For bentone greases, the ${\beta}_2$ is about constant independent of concentration at a given temperature as found in the literature. The resident-time effect has not been clearly demonstrated in this research; this is due partly to the nature of the greases used in our research and partly to the small values of L/R of our capillaries, the resident time being proportional to the value L/R.

  • PDF

A Study on the Indoor Air Quality in the bedroom with respect to Temperature and Humidity conditions (온도 및 습도 조건에 따른 침실 공기환경에 관한 연구)

  • Kim, Dong-Gyu;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.11 no.3
    • /
    • pp.31-36
    • /
    • 2011
  • People spend most of their time inside buildings recently, so the indoor air quality is one of the most important factors to human health. Furthermore, minimum energy use with proper ventilation systems for pleasant indoor environment is necessary because of energy shortage over the world. The concern to maintain proper indoor air quality at home has been increased, and a proper indoor air quality is continuously requested by the residents. By measuring and analyzing the density fluctuation of $CO_2$ through indoor humidity and testing personal reactions regarding comfort condition, we can obtain a way to effective ventilation. Heat and carbon dioxide emissions from resident's metabolism and construction materials could be the causes of indoor air pollution. If these materials stay indoors for a long time, it could directly influence the resident's health condition with diseases. It also leads massive energy use. Therefore, the way to save energy and to have effective control of indoor ventilation is needed. This study presented the control method of bedroom ventilation by $CO_2$ concentration change and subjective evaluation.

Properties of Indoor Particles Collected in Japanese Homes

  • Ma, Chang-Jin;Kang, Gong-Unn;Kang, Chang-Hee
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.1
    • /
    • pp.31-38
    • /
    • 2015
  • Due to the heightened ambient $PM_{2.5}$ levels, the whole citizen of Japan, especially dwellers in Fukuoka Prefecture, start to make attention to the particulate matter (PM) of indoor environments. This study was aimed to thoroughly estimate the characteristics of indoor PM collected in five Japanese homes located in Fukuoka Prefecture. Simultaneous indoor measurements of PM were intensively made at five homes using filter-pack samplers, particle counters, and $PM_{2.5}$ monitors for a day in springtime, 2012. Major ionic and carbonaceous components were also analyzed. The time series fluctuation of PM number concentration was gradually decreased by 6 AM and then it was rapidly increased by 8 AM in all indoor sites. The maximum level of $PM_{2.5}$ was measured at the morning time (8 AM-9 AM) when the resident's behavior was fast and strenuous. The Indoor/Out-door (I/O) ratio for the giant PM larger than $5.0{\mu}m$ was 1.16. It was possible to identify PM types and estimate the resident's behavior through the comparison the theoretically calculated and the measured retention times for several types of PM in an indoor site. The theoretically reconstructed mass concentration of $PM_{2.0-0.3}$ suggested that the portion of $PM_{2.5}$ in indoor was quietly occupied by $PM_{0.3}$ or the PM inherently originated from indoor environment.

Drug Interaction of Metformin and Aspirin in Rabbits (메트포르민과 아스피린의 약물상호작용)

  • Choi, Jun Shik;Choi, In
    • Korean Journal of Clinical Pharmacy
    • /
    • v.13 no.2
    • /
    • pp.67-71
    • /
    • 2003
  • The purpose of this study was to investigate the effect of aspirin (5, 10, 20 mg/kg) on the pharmacokinetics of metformin $(15\;mg/kg)$ in rabbits. The plasma concentration of metformin was decreased significantly (p<0.05) by co-administration of aspirin (10, 20 mg/kg) compared with control. Area under the plasma concentration-time curve (AUC) of metformin was decreased significantly (p<0.05) by co-administration of aspirin (10, 20mg/kg) compared with control. Relative bioavailability $(R.B\%)$ of metformin by co-administration was 79.3 (5 mg/kg), 57.5 (10 mg/kg) and 62.5 (20 mg/kg). Peak plasma concentration of metformin was significantly (p<0.05) decreased by co-administration of aspirin (10, 20 mg/kg) compared with control. The elimination rate constant $(K_{el})$ of metformin was increased by co-administration of aspirin (10, 20 mg/kg) compared with control. The terminal half-lifes $(t_{1/2})$ and mean resident time (MRT) of metformin by co-administration of aspirin (10, 20 mg/kg) were decreased significantly (p<0.05) compared with control. It is considered that the significantly decreased plasma concentration and AUC of metrormin is due to increase of elimination in urine acidified by co-administration of aspirin. The results suggest that the dosage of metformin should be adjusted when metformin is co-administered with aspirin in the clinical situation.

  • PDF

The Actual State of Indoor Environment in Solitary Elderly Houses at Rural District during Winter (농촌지역 독거노인주택의 겨울철 실내환경 실태)

  • Choi, Yoon-Jung;Kim, Yun-Hee;Kim, Lan-Hee
    • Journal of the Korean housing association
    • /
    • v.21 no.3
    • /
    • pp.1-9
    • /
    • 2010
  • The purposes of this study were to determine the actual state of indoor environments of solitary elderly houses in the rural district during winter and to analyze the relationship between the influencing factors and indoor physical elements. Field surveys consisted of measurements of physical elements, observations of living factors, and resident's responses in interviews. Field surveys were carried out in 4 houses from $28^{th}$ of February to $2^{nd}$ of March 2008. The elements measured were air temperature, relative humidity, floor temperature, seating-place temperature, CO2 concentration, CO concentration, and illumination. The results showed that the average indoor temperature for houses was $13.5{\sim}22.5^{\circ}C$, relative humidity was 30.6~55.4%, floor temperature was $13.9{\sim}24.0^{\circ}C$, temperature when seated was $27.6{\sim}51.1^{\circ}C$, $CO_2$ concentration was 1434.6~3305.5 ppm, CO concentration was 2.8~8.4 ppm, and illumination was 31.0~96.7 lux. The residents' clothing values were 1.10~1.78 clo. The environment was evaluated as being in an unsuitable state, and it was revealed that the main reason was the lack of heating and ventilation.