Water Quality Change Characteristics of Treated Water in Distribution System of Water Treatment Plant of Jeiu City (제주시 정수장 처리수의 급수과정별 수질변화 특성)

  • Han, Kyung-Yong;Lee, Min-Gyu;Chung, Ho-Jin;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • v.16 no.1
    • /
    • pp.81-94
    • /
    • 2007
  • The purpose of this work is to investigate the water quality change characteristics of treated water in water distribution systems of Water Treatment Plants (WTPs) of Jeju City. For this, the raw water, treated water and tap water that did not pass (named as not pass-tap water) and passed through the water storage tank (named as pass-tap water) were sampled and analyzed monthly from September 2001 to August 2002, for four (W, S, B and O) WTPs except for D WTP (where treated water is not supplied continuously) among WTPs of Jeju City. The concentrations of $NO_3^-$ and $Cl^-$ of treated water in distribution systems changed little, but changed seasonally, which is considered to be based on the seasonal variation of the quality of raw water. The pH of treated water changed little in distribution systems for S WTP, but for the other WTPs, the pH of not pass-tap water was similar to that of treated water and the pH of pass-tap water was higher than that of treated water. The turbidity of treated water in distribution systems changed little except for W2 of W WTP and S4 and S5 of S WTP, where it was higher than that of each treated water. The residual chlorine concentrations between treated water and not pass-tap water changed little, but those between treated water and pass-tap water changed greatly, based on the its long residence time in water storage tank and so its reaction with organic matter, etc or its evaporation. The concentrations of TTHMs (total trihalomethanes) and $CHCl_3$ that induce cancers in water distribution systems of these WTPs, were much lower than their water quality criteria and those in other cities. The concentrations of TTHMs of treated water and not pass-tap water were similar, but concentrations of pass-tap water were 1.5 to 2.0 times higher than those of treated water and not pass-tap water, due to the reaction of residual chlorine and organic matter, etc, with the result of long residence time in water storage tank.

Different Pharmacokinetics of Aucubin in Rats of Carbon tetrachloride and D-Galactosamine-induced Hepatic Failure (사염화탄소와 갈락토사민 간장해 시의 오큐빈의 체내동태 차이)

  • 김미형;심창구;장일무
    • YAKHAK HOEJI
    • /
    • v.37 no.4
    • /
    • pp.383-388
    • /
    • 1993
  • Pharmacokinetics of aucubin, an irdoid glucoside, was compared in rats of experimental hepatic failure(EHF). EHF was induced by CCI$_{4}$ or D-galactosamine pretreatment. This work was designed to find out any differences in the pharmacokinetics of aucubin that may explain the different protective effect of aucubin on CCI$_{4}$- and galactosamine-induced EHF : aucubin reportedly protected CCI$_{4}$-inducing hepatotoxicity effectively, but did not for galactosamine-hepatotoxicity. EHF was induced by intraperitoneal injection Of CCI$_{4}$(0.9ml/kg) or galactosamine(250 mg/kg) to Wistar rats 24 hr before the pharmacokinetic study. The rats were fasted during the 24 hr. Aucubin was iv injected at a dose of 15 mg/kg and the plasma aucubin was assayed by HPLC. There were no significant differences in the pathophysiologies(body weight, liver weight, GTP, hematocrit, blood cell distrbution and plasma protein binding of aucubin) between the two EHF models except GOP which was significantly (p<0.05) higher in CCI$_{4}$-than in galactosamine-EHF. On the other hand, pharmacokinetics of aucubin such as total cleatance(CL$_{t}$), distribution volume at steady-state(Vd$_{ss}$), and mean residence time(MRT) differed significantly(p<0.05) between the models : for example, CL$_{t}$ was increased two fold by CCI$_{4}$, but not by galaclosamine ; Vd$_{ss}$, in galactosamine-EHF was higher than that in CCI$_{4}$-EHF ; MRT was decreased by CCI$_{4}$, but increased conversely by galactosamine. The increase of CL$_{t}$(and decrease of MRT) in rats of CCI$_{4}$-EHF was contrary to the general expectation for the hepatic failure : most of the hepatic failures have been known to decrease CL$_{t}$ of the administered drugs. Whether the difference in the pharmacokinetics is responsible for the different protective effect of aucubin against the two EHF models is of interest. However, much more studies on biliary excretion, urinary excretion, and hepatic uptake in cellular level should be preceded before any conclusions are made on the role of different pharmacokinetics on the different pharmacology of aucubin.

  • PDF

Ignition of a solid fuel by thermal radiation (열복사에 의한 고체연료 점화 연구)

  • Kim, Myeong-Hyo;Baek, Seung-Uk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.3
    • /
    • pp.294-302
    • /
    • 1998
  • Ignition characteristics of a vertical solid fuel plate with block have been investigated experimentally. For low radiant heat flux, ignition does not occur in a vertical solid fuel plate without block. In the case with the block on a vertical fuel plate, however, ignition can occur by increasing the residence time and the time to absorb the incident radiation flux by fuel vapor in gas phase. The ignition occurs below block and the point varies according to the block location and the block height. As the block height increases, the block locates at higher position, and the hot wall temperature increases, the ignition delay time decreases. Also as the initial temperature of fuel plate rises, the ignition delay time of the solid fuel plate decreases. The temperature distribution of solid fuel plate with block is nearly proportional to the radiant heat flux distribution. Therefore, the effect temperature by natural convection heat transfer is of the same order as that of inhibition of temperature increase by pyrolysis.

Effect of Flow Distribution on the Combustion Efficiency In an Entrained-Bed Coal Reactor (분류층 석탄반응로에서 유동분포가 연소성능에 미치는 영향)

  • CHO, Han Chang;SHIN, Hyun Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.8
    • /
    • pp.1022-1030
    • /
    • 1999
  • A numerical study was carried out to analyze the effect of flow distribution of stirred part and plug flow part on combustion efficiency at the coal gasification process in an entrained bed coal reactor. The model of computation was based on gas phase eulerian balance equations of mass and momentum. The solid phase was described by lagrangian equations of motion. The $k-{\varepsilon}$ model was used to calculate the turbulence flow and eddy dissipation model was used to describe the gas phase reaction rate. The radiation was solved using a Monte-Carlo method. One-step parallel two reaction model was employed for the devolatilization process of a high volatile bituminous Kideco coal. The computations agreed well with the experiments, but the flame front was closer to the burner than the measured one. The flow distribution of a stirred part and a plug flow part in a reactor was a function of the magnitude of recirculation zone resulted from the swirl. The combustion efficiency was enhanced with decreasing stirred part and the maximum value was found around S=1.2, having the minimum stirred part. The combustion efficiency resulted from not only the flow distribution but also the particle residence time through the hot reaction zone of the stirred part, in particular for the weak swirl without IRZ(internal recirculation zone) and the long lifted flame.

Deposition of Polydisperse Particles in a Falkner-Skan Wedge Flow (포크너-스캔 경계층유동에서의 다분산 입자부착에 대한 연구)

  • 조장호;황정호;최만수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.9
    • /
    • pp.2342-2352
    • /
    • 1995
  • Deposition of flame-synthesized silica particles onto a target is utilized in optical fiber preform fabrication processes. The particles are convected and deposited onto the target. Falkner-Skan wedge flow was chosen as the particle laden flow. Typically the particles are polydisperse in size and follow a lognormal size distribution. Brownian diffusion, thermophoresis, and coagulation of the particles were considered and effects of these phenomena on particle deposition were studied. A moment model was developed in order to predict the particle number density and the particle size distribution simultaneously. Particle deposition with various wedge configurations was examined for conditions selected for a typical VAD process. When coagulation was considered, mean particle size and its standard deviation increased and particle number density decreased, compared to the case without coagulation. These results proved the fact that coagulation effect expands particle size distribution. The results were discussed with characteristics of thermal and diffusion boundary layers. As the boundary layers grow in thickness, overall temperature and concentration gradients decrease, resulting in decrease of deposition rate and increase of particle residence time in the flow and thus coagulation effect.

Fabrication of High-Density Nickel Hydroxide Powder-I (고밀도 수산화니켈 분말의 제조에 관한 연구-I)

  • 신동엽;조원일;신치범;조병원;강탁;윤경석
    • Journal of Surface Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.92-100
    • /
    • 1995
  • To increase the capacity of positive electrode materials for matching the high capacity negative electrode materials in alkaline rechargeable batteries, high-density nickel hydroxide powders were made through a continuous process from nickel sulfate reacted with ammonia and sodium hydroxidc. The effect of operating conditions on structure, shape, size distribution, apparent density and tap density of powders were investigated. Crystal structure of nickel hydroxide powder was hcp according to Bravais Lattice. The increase of mean residence time promoted the growth of (101) plane. The shape of powder was nearly spherical. Their size was in the range of $2~50\mu\textrm{m}$. The size distribution of the powders prepared was narrower than that of commercially obtained nickel hydroxide. Apparent density and tap density were 1.6~1.7g/cc and 2.0~2.1g/cc, respectively.

  • PDF

Start-up dynamics in a CMSMPR crystallizer (CMSMPR 결정화기의 시동 특성 연구)

  • 신영준;이철수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.200-204
    • /
    • 1986
  • Particle size distribution in a Continuous Mixed Suspension Mixed Crystal Removal (CMSMPR) crystallizer has been analyzed using the Population Balance (PB) model. This method presents difficulties when the growth rate of crystal depends on the crystal size. Recent studies indicate that in many cases the growth rate is dependent on size when the crystal sizes are small. In this study, a Residence Time Distribution(RTD) model was proposed to take the size dependence into account together with an appropriate numerical scheme. When compared with the approximate results based on PB model, RTD model results showed improvements also a nucleation effect which is normally unimportant for steady state analysis. Start-up data for NaCl-Water-Ethanol system was compared with computed values.

  • PDF

Experimental Analysis on Particle Growth m TEOS/O2 Plasma Reactor (TEOS/O2 플라즈마 반응기에서 미립자 성장에 대한 실험적 분석)

  • Kim, Dong-Joo;Kim, Kyo-Seon
    • Journal of Industrial Technology
    • /
    • v.21 no.B
    • /
    • pp.149-153
    • /
    • 2001
  • A study on the particle growth in $TEOS/O_2$ plasma was performed, and particle size and its distribution was measured by the electrical aerosol analyzer (EAA), light scattering particle size analyzer and the particle size was also determined by SEM. The effects of process variables such as total gas flow rate, reactor pressure, supplied power and initial reactant concentration on the particle growth were investigated. From the EAA results, the particle size distribution is divided into three groups of the cluster size and the small and large size particles. The particle size distribution measured by the light scattering particle size analyzer becomes bimodal, because the cluster size particles smaller than 20 nm in diameter cannot be detected by the light scattering particle size analyzer. The size of particles measured by the light scattering particle size analyzer is in good agreements with those by the SEM. Also we could understand that the particle formation is very sensitive to the changes of reactor pressure and reactant concentration. As the total gas flow rate increases, the particle size decreases because of the shorter residence time. As the reactor pressure, or the reactant concentration increases, the particle concentration increases and the particles grow more quickly by the faster coagulation between particles.

  • PDF

Pharmacokinetics rind Tissue Distribution of a Recombinant truman Erythropoietin, GC-rhEPO (유전자 재조합 사람형 erythropoietin, GC-rhEPO의 약물동태 및 조직분포)

  • 김선돈;한성규;이호성;김성남;정원휘;백대현;조은성;허재욱;류판동
    • Biomolecules & Therapeutics
    • /
    • v.8 no.2
    • /
    • pp.171-178
    • /
    • 2000
  • To evaluate the pharmacokinetic properties and tissue distribution of a newly developed recombinant human erythropoietin (GC-rhEPO), we analyzed the plasma and tissue levels of erythropoietin by an ELISA after intravenous (IV) and subcutaneous (SC) adminstration to the male rats at the doses of 20, 100, 500 or 2,500 unit/kg. After single IV bolus injection of GC-rhEPO, the plasma concentration was rapidly increased and decreased with two phases with half-lives of 13.4 min and 2.94 hours. AUC was increased dose- dependently but plasma half-lives remained constant regardless of GC-rhEPO doses. Following SC administration, the plasma concentration increased slowly with half-life of 9.2 hours and reached peak at 8 hours. Mean residence time and bioavailability were 18.2 hours and 44%, respectively. After single IV dose of 100 unit/kg, tissue GC-rhEPO level was higher in bone marrow and spleen, while the depletion rate was slower in liver and bone marrow, indicating the higher affinity of GC-rhEPO to bone marrow. Taken together, the experimental results indicate that GC-rhEPO contained the typical pharmacokinetic properties and the tissue distribution patterns inherent to human erythropoietin.

  • PDF

Activity Factors of the Korean Exposure Factors Handbook

  • Jang, Jae-Yeon;Jo, Soo-Nam;Kim, So-Yeon;Lee, Kyung-Eun;Choi, Kyung-Ho;Kim, Young-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.47 no.1
    • /
    • pp.27-35
    • /
    • 2014
  • Exposure factors based on the Korean population are required for making appropriate risk assessment. It is expected that handbooks for exposure factors will be applied in many fields, as well as by health department risk assessors. The present article describes the development of an exposure factors handbook that specifically focuses on human activities in situations involving the possible risk of exposure to environmental contaminants. We define majour exposure factors that represent behavioral patterns for risk assessment, including time spent on routine activities, in different places, on using transportation, and engaged in activities related to water contact including swimming, bathing and washing. Duration of residence and employment are also defined. National survey data were used to identify recommended levels of exposure factors in terms of time spent on routine activities and period of residence and employment. An online survey was conducted with 2073 subjects who were selected using a stratified random sampling method in order to develop a list of exposure factors for the time spent in different places and in performing water-related activities. We provide the statistical distribution of the variables, and report reference levels of average exposure based on the reliable data in our exposure factors handbook.