• Title/Summary/Keyword: reservoir water effect

Search Result 353, Processing Time 0.024 seconds

Effect of irrigation reservoir, antecedent soil moisture condition and Huff time distribution on peak discharge in a basin (농업용 저수지, 선행토양함수조건 및 Huff 시간 분포가 유역의 첨두홍수량에 미치는 영향 분석)

  • Kwon, Minsung;Ahn, Jae-Hyun;Jun, Kyung Soo;Kim, Tae-Woong
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.5
    • /
    • pp.417-424
    • /
    • 2018
  • This study analyzed the effect of irrigation reservoirs, antecedent soil moisture conditions (AMC) and Huff time distribution on peak discharge using Monte Carlo simulation. The peak discharge was estimated for four different cases in combination of irrigation reservoir capacity, AMC, and Huff time distribution. Applying 100% reservoir capacity or AMC-III, the peak discharges corresponding return periods of 50~300 years were overestimated by 25~30% compared to those of cases that considered the probability of occurrence for individual condition. Applying the 3rd quantile huff distribution, the peak discharges were overestimated by 5% over the peak discharge that considered the probability of occurrence. The overall results indicated that the effect on the peak flood of Huff distribution was less than AMC and reservoir storage.

Prediction of Excess Pore Water Pressure of Reservoir Embankment on Soft Ground (연약지반상에 축조된 저수지 제방의 과잉공극수압 예측)

  • Min, Hag-Gyou;Lee, Dal-Won
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.2
    • /
    • pp.37-44
    • /
    • 2008
  • A theoretical equation was proposed to consider the effect of ponding for the excess pore water pressure in agricultural reservoir on soft clay ground. The value of excess pore water pressure predicted using the proposed equation was compared to those predicted with the Terzaghi's method and the finite difference method(FDM), respectively, for the purpose of verification. The degree of consolidation according to ponding predicted by applying the proposed equation was close to the observed degree of consolidation on the double drainage condition(at DP-3) but it was less than the observed degree of consolidation on the single drainage condition(at DP-5). The equation was very applicable to practice because the analysis result by the equation was close to the observed data.

Application of an Unsteady River Water Quality Model for the Analysis of Reservoir Flushing Effect on Downstream Water Quality (저수지 플러싱 방류 효과분석을 위한 비정상상태 하천수질모형의 적용)

  • Chung, Se-Woong
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.10
    • /
    • pp.857-868
    • /
    • 2004
  • Since the self-purification capacity of rivers in Korea is significantly controlled by environmental maintenance flow supplied by upstream reservoirs during drought season, it is obviously important to operate the river and reservoir systems considering not only water quantity aspect but also conservation of downstream water quality and ecosystem. In this study, an unsteady river water quality model KORIVl- WIN was developed as a tool for evaluating the impact. of reservoir operations on the downstream water quality. The model parameters were calibrated and verified using field data obtained in Geum River on September and October of 2002, respectively. Intensive data sampling was performed on November 22, 2003 to investigate the effect of a short-term flushing discharge of Daecheong Reservoir, which increased outflow from 30 $m^3$/s to 200 $m^3$/s for 6 hours, on downstream water quality. The model performance was evaluated by comparing simulated results with observed data including hydraulics, biochemical oxygen demand(BOD$_{5}$), nitrogen and phosphorus species during the flushing event. It showed very good performance in predicting the travel time of flushing flow and water quality variations of dissolved forms of nitrogen and phosphorus species, while revealed large deviations for BOD$_{5}$ possibly due to missing the effect of organic matters resuspension from river bottom sediment during the wave front passage.

Effect of Hydraulic-Gun-Aerators on Cyanobacterial Bloom in a Dam Reservoir (댐저수지의 남조류 수화에 대한 간헐식 폭기장치의 효과)

  • Lee, Jeong-Ho
    • ALGAE
    • /
    • v.19 no.1
    • /
    • pp.23-30
    • /
    • 2004
  • The purpose of this study is to assess the effects that hydraulic-gun-aerators have on cyanobactedial bloom in Sayeon Dam Reservoir in Ulsan City, Korea. A total of nine hydraulic-gun-aerators are in operation at the reservoir withe 100 m spacing between each aerator to control severe cyanobacterial bloom in the dam reservoir. The field studies were performed an total four times at two sampling stations in the reservoir from July to August in 2001. The standing crops of phytoplankton did not changed significantly by the operation. The cell concentration of the cyanobacteria at the surface layer were reduced about 10%, which is a poor result for the dispersing cyandobacteria deeper into the water. The average surface temperature during the study was reduced by 2.0$^{\circ}C$ by the hydraulic-gun-aerators. The effect of the operation on the vertical distribution of DO concentration was clear. However, the hydraulic-gun-aerators were not expected to have an effect in the lowest layer of the hypolimnion. In the study, it was proposed that installation distance between each hydraulic-gun-aerator would be proper when they are apart about 120 m based on DO depth profiles.

An Efficient Management of Sediment Deposit for Reservoir Long-Term Operation (2) - Sediment Distribution and Reduction Method in Reservoir (저수지 장기운영을 위한 퇴적토사의 효율적 관리(2) - 저수지 퇴사분포 및 저감방안)

  • Ahn, Jae Hyun;Jang, Su Hyung;Choi, Won Suk;Yoon, Yong Nam
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1094-1100
    • /
    • 2006
  • In this study, the reservoir sediment reduction methods for long-term operation are proposed by the analysis of both sediment deposit characteristics and sediment reduction effect by each method. To that end, a flowchart for sediment analysis in reservoir is established and sediment deposit is simulated by SMS-SED2D model. The sediment reduction methods which are sediment passing (sluicing), flushing, trapping, bypassing and mechanical removal are used. From the simulation results, the effective method for sediment reduction is operation which is coupled by both sediment passing with sand gate and sediment trapping with debris dam. And If sediment flushing will be used once a year after 50 years, conservation storage can be secured until 100 years after dam construction.

Analysis on Flood Control Effect of Siphon Spillway by Reservoir Routing (저수지 추적을 통한 사이펀 여수로의 홍수조절 효과 분석)

  • Ko, Suhyeon;Kim, Jaeyoung;Lee, Giha
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.11
    • /
    • pp.55-63
    • /
    • 2013
  • Agricultural small dam reservoirs in Korea are vulnerable to flooding because of insufficient flood control capacity and deterioration such that reservoir water level is likely to rise rapidly and a large amount of water release quickly to downstream without flood warning. In this study, we performed hydrologic analysis to estimate design flood(200 years return period ${\times}1.2$) and also evaluated the effect of siphon spillway as a structural countermeasure for flood control and mitigation by applying reservoir routing to the Jipyeong reservoir, located in Sangju, Korea. The results show that the design flood was calculated at $284.3m^3/s$, and water level and water release decreased by 40cm and $91m^3/s$, respectively.

Integrated Watershed Modeling Under Uncertainty (불확실성을 고려한 통합유역모델링)

  • Ham, Jong-Hwa;Yoon, Chun-Gyoung;Loucks, Daniel P.
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.4
    • /
    • pp.13-22
    • /
    • 2007
  • The uncertainty in water quality model predictions is inevitably high due to natural stochasticity, model uncertainty, and parameter uncertainty. An integrated modeling system under uncertainty was described and demonstrated for use in watershed management and receiving-water quality prediction. A watershed model (HSPF), a receiving water quality model (WASP), and a wetland model (NPS-WET) were incorporated into an integrated modeling system (modified-BASINS) and applied to the Hwaseong Reservoir watershed. Reservoir water quality was predicted using the calibrated integrated modeling system, and the deterministic integrated modeling output was useful for estimating mean water quality given future watershed conditions and assessing the spatial distribution of pollutant loads. A Monte Carlo simulation was used to investigate the effect of various uncertainties on output prediction. Without pollution control measures in the watershed, the concentrations of total nitrogen (T-N) and total phosphorous (T-P) in the Hwaseong Reservoir, considering uncertainty, would be less than about 4.8 and 0.26 mg 4.8 and 0.26 mg $L^{-1}$, respectively, with 95% confidence. The effects of two watershed management practices, a wastewater treatment plant (WWTP) and a constructed wetland (WETLAND), were evaluated. The combined scenario (WWTP + WETLAND) was the most effective at improving reservoir water quality, bringing concentrations of T-N and T-P in the Hwaseong Reservoir to less than 3.54 and 0.15 mg ${L^{-1}$, 26.7 and 42.9% improvements, respectively, with 95% confidence. Overall, the Monte Carlo simulation in the integrated modeling system was practical for estimating uncertainty and reliable in water quality prediction. The approach described here may allow decisions to be made based on probability and level of risk, and its application is recommended.

Modeling the Effect of Intake Depth on the Thermal Stratification and Outflow Water Temperature of Hapcheon Reservoir (취수 수심이 합천호의 수온성층과 방류 수온에 미치는 영향 모델링)

  • Sun-A Chong;Hye-Ji Kim;Hye-Suk Yi
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.6
    • /
    • pp.473-487
    • /
    • 2023
  • Korea's multi-purpose dams, which were constructed in the 1970s and 1980s, have a single outlet located near the bottom for hydropower generation. Problems such as freezing damage to crops due to cold water discharge and an increase the foggy days have been raised downstream of some dams. In this study, we analyzed the effect of water intake depth on the reservoir's water temperature stratification structure and outflow temperature targeting Hapcheon Reservoir, where hypolimnetic withdrawal is drawn via a fixed depth outlet. Using AEM3D, a three-dimensional hydrodynamic water quality model, the vertical water temperature distribution of Hapcheon Reservoir was reproduced and the seasonal water temperature stratification structure was analyzed. Simulation periods were wet and dry year to compare and analyze changes in water temperature stratification according to hydrological conditions. In addition, by applying the intake depth change scenario, the effect of water intake depth on the thermal structure was analyzed. As a result of the simulation, it was analyzed that if the hypolimnetic withdrawal is changed to epilimnetic withdrawal, the formation location of the thermocline will decrease by 6.5 m in the wet year and 6.8 m in the dry year, resulting in a shallower water depth. Additionally, the water stability indices, Schmidt Stability Index (SSI) and Buoyancy frequency (N2), were found to increase, resulting in an increase in thermal stratification strength. Changing higher withdrawal elevations, the annual average discharge water temperature increases by 3.5℃ in the wet year and by 5.0℃ in the dry year, which reduces the influence of the downstream river. However, the volume of the low-water temperature layer and the strength of the water temperature stratification within the lake increase, so the water intake depth is a major factor in dam operation for future water quality management.

Optimal Flood Control System for Irrigation Reservoir (관개저수지의 최적 홍수관리방안)

  • 문종필;민진우;김영식;박승기;김태철
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.311-317
    • /
    • 1998
  • Recently irrigation reservoir has been developed to perform multipurpose function. To get a maximum effect it requires to establish optimal management system for irrigation reservoir in drought and flood season. Especially we dealt with optimal flood control system for irrigation reservoir in this study. This system consists of real-time rainfall data via online system, real-time flood forecasted by SCS method in hourly basis, storage volume by water balance equation, optimal releasing discharge from the gate, the water level in right downstream, and calculation of innundated area, depth, and time using GIS, and amount of flood damages. If we consider the relation of these sub module reasonably, we can reach the optimal flood control to minimize flood damage

  • PDF

Estimation of Pollutant Load to Yongdam Reservoir Considering Rainfall Effect (강우의 영향을 고려한 용담호 유입오염부하량 산정)

  • Lee, Eun-Hyong;Seo, Dong-Il
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.4
    • /
    • pp.521-531
    • /
    • 2003
  • Pollutant load to Yongdam Reservoir considering rainfall effect is estimated using data collected during dry and wet days between Dec 1998 and Oct. 1999. Limit of significant rainfall was assumed to be as 10 mm/day and numbers of days of significant rainfall for each month were counted using 10 years of meteorological data of the study area. Water quality input concentrations were estimated by taking weighted averages of concentrations in dry and wet days in each month. The resulting concentrations were used as inputs for water quality modeling of Yongdam Reservoir. When rainfall effect was included average reservoir concentrations of BOD, TN and TP were increased by 70%, 5% and 27%, respectively Considering the fact that Korea is under the significant influence of monsoon effect during the summer, it should be important to include rainfall effect in estimating pollutant input to receiving waters. This method is expected to increase reliability of annual water quality modeling results by providing realistic input data.