• Title/Summary/Keyword: reservoir temperature

Search Result 413, Processing Time 0.024 seconds

Hydrodynamic Modeling of Saemangeum Reservoir and Watershed using HSPF and EFDC (HSPF-EFDC를 이용한 새만금호와 유역의 수리 변화 모의)

  • Shin, Yu-Ri;Jung, Ji-Yeon;Choi, Jung-Hoon;Jung, Kwang Wook
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.3
    • /
    • pp.384-393
    • /
    • 2012
  • Saemangeum lake is an artificial lake created by reclamation works and an estuary embankment since 2006. The sea water flows into the lake by the operation of two sluice gates, and the freshwater enters into the lake by the upper streams. For the reflection of hydrology and hydrodynamics effects in Saemangeum area, a hydrodynamics model was developed by connecting Hydrological Simulation Program with Fortran (HSPF) and Environmental Fluid Dynamic Code (EFDC). The HSPF was applied to simulate the freshwater discharge from the upper steam watershed, and the EFDC was performed to compute water flow, water temperature, and salinity based on time series from 2008 to 2009. The calibration and validation are performed to analyze horizontal and vertical gradients. The horizontal trend of model simulation results is reflected in the trend of observed data tolerably. The vertical trend is conducted an analysis of seasonal comparisons because of the limitation of vertically observed data. Water temperature reflects on the seasonal changes. Salinity has an effect on the near river input spots. The impact area of salinity is depending on the sea water distribution by gate operation, mainly.

Community Dynamics of Phytoplankton and Bacteria as Affected by Physicochemical Environmental factors in Hoeya Dam Reservoir (회야댐 저수지에서 물리 ${\cdot}$ 화학적 환경요인에 따른 식물플랑크톤과 세균 군집의 변화)

  • Kim, Dae-Kyun;Choi, Ae-Ran;Lee, Hye-Kyeong;Kwon, O-Seob;Kim, Jong-Seol
    • Korean Journal of Ecology and Environment
    • /
    • v.37 no.1 s.106
    • /
    • pp.26-35
    • /
    • 2004
  • We investigated the effect of physicochemical environmental factors on the community dynamics of phytoplanktons and bacteria at the Hoeya Dam Reservoir, a drinking water reservoir for Ulsan city. Water samples were collected and analyzed every two to four weeks at three sites along the reservoir from April to October, 2001. During the study period, the Secchi depths were between 0.4 and 3.5 m. At the surface layer of water column, temperature ranged 10.2 ~ $32.0^{\circ}C$, pH 7.3${\sim}$9.6, dissolved oxygen 5.5 ${\sim}$ 12.4 mg $L^{-1}$, $BOD_5$ 0.8 ${\sim}$ 5.0 mg $L^{-1}$, $COD_{Mn}$ 3.7 ${\sim}$ 10.0 mg $L^{-1}$, and Chl-a 8.9 ${\sim}$ 60.9 mg $m^{-3}$. At the bottom layer, temperature varied 7.2 ${\sim}$ $28.9^{\circ}C$, pH 7.1 ${\sim}$ 9.3, dissolved oxygen 0.6 ${\sim}$ 9.7 mg $L^{-1}$, $BOD_5$ 0.8 ${\sim}$ 4.5 mg $L^{-1}$, $COD_{Mn}$ 3.9 ${\sim}$ 10.0 mg $L^{-1}$, and Chl-a 4.3 ${\sim}$ 81.9 mg $m^{-3}$. The numbers of phytoplanktons were 7.4${\pm}10^2{\sim}2.6{\pm}10^5$ cells $mL^{-1}$ at surface and 2.5${\pm}10^2{\sim}2.4{\pm}10^4$ cells $mL^{-1}$ at bottom, and were positively correlated with water temperature and Chl- a concentration. Genus Stephanodiscus and genus Oscillatoria dominated on April and on May, respectively. Cyanobacterial blooms of Aphanizomenon, Microcystis, Anabaena were observed from June to early September, and thereafter Stephanodiscus and Aulacoseiral dominated again. Total microbial counts ranged 1.73${\pm}10^4{\sim}1.68{\pm}10^5$ cells $mL^{-1}$, and were positively correlated with water temperature and phytoplankton counts at surface water. Heterotrophic plate counts (HPCs) ranged 30${\sim}4.1{\pm}10^3$ CFU $mL^{-1}$, and were positively correlated with $BOD_5$ and $NO^3\;^-$-N concentration at bottom water. Unlike the total microbial counts, the numbers of fecal coliforms and fecal streptococci as well as HPCs were higher at the bottom than the surface layer and were highest at the upper a site among the three sampling sites. Since the concentrations of fecal coliforms and streptococci were still high at the bottom of site c, where intake for water treatment plant is located, it appeared that special management of water treatment processes may be needed especially after strong rainfall.

Seasonal Patterns of Reservoir Thermal Structure and Water Column Mixis and Their Modifications by Interflow Current (인공호에서 수온의 수직분포와 수층혼합의 계절적 변화 및 중층수 유입 현상의 영향)

  • An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.34 no.1 s.93
    • /
    • pp.9-19
    • /
    • 2001
  • contrasting monsoon between 1993 and 1994 produced an interannual difference in hydrology. Theoretical water residence time (TWRT) in monsoon 1993 averaged 27 d, which was>3 months shorter compared to the TWRT in monsoon 1994. A dominant physical process influencing thermal stratification, water movement, and mixing regime was an interflow current in 1993. During summer 1993, river water plunged to mid-lake (location 27 km) and passed through the 10${\sim}$20m stratum of the reservoir, resulting in an isolation of epilimnetic lake water from advected river water. The interflow disrupted thermal stratification and produced a meta-hypolimnetic warming of >4$^{\circ}C$ downlake, thereby increased a mixing depth (>13 m). In contrast, during monsoon 1994 density currents were not observed and strong thermal stratification occurred in the entire reservoir, resulting in > 2 fold greater thermal resistance (8.2${\times}10^{5}$ erg)compared to 1993 (4.0${\times}10^{5}$ erg). This reservoir was identified as a typical warm monomictic reservoir which showed one mixis during early winter. The timing of overturn, however, differed between the two years as a result of distinct contrast in TWRT and thermal regime; overturn in 1993 occured about one month earlier relative to that in 1994. Hypolimnetic warming was predictable in this system; the variation in discharge accounted (Y = 4.35-0.06X+0.10X$^{2}$, p<0.0001)for 98% of the interannual variation in hypolimnetic temperature. Overall data suggest that thermal stability, the timing of fall overturn, and water residence time in this system are primarily regulated by the intensity of monsoon.

  • PDF

The Development of Evaluation Chart for the Applicability of CO2 Flooding in Oil Reservoirs and Its Applications (생산유전의 CO2 공법 적용성 평가를 위한 평가차트 개발 및 응용)

  • Kwon, Sunil;Cho, Hyunjin;Ha, Sehun;Lee, Wonkyu;Yang, Sungoh;Sung, Wonmo
    • Korean Chemical Engineering Research
    • /
    • v.45 no.6
    • /
    • pp.638-647
    • /
    • 2007
  • In this study, we present the evaluation chart for assessing the applicability of $CO_2$ flooding method to oil reservoirs. The evaluation chart consists of four categories as source availability, miscibility, applicability and injecting method of miscible flooding. The applicability of reservoir and oil in the chart has basic items of the properties such as oil gravity, viscosity, oil saturation, reservoir temperature and permeability, and these are quantitatively graded. Meanwhile, for additional items of $CO_2$ purity, reservoir thickness and formation dip, they are graded as "highmediumlow". In the case of evaluating the injection method of either continuous injection or WAG ($CO_2$), the qualitative decision will be made according to formation dip, vertical permeability, reservoir thickness, etc. The recommended score in the chart was assigned by utilizing 51 oil producing fields which $CO_2$ flooding is successfully being applied. The evaluation chart developed in this work has been applied to the Captain oil producing field located in Scotland as well as to the Onado oil field of Venezuela, which Korean oil companies have participated in. For the Captain field, the reservoir quality in terms of permeability and porosity is considered to be very excellent to flow the oil. The oil in captain field contains heavier component of $C_{21+}$ as 54%. Therefore, this heavy oil could be immiscibly displaced, hence the evaluating result with the basis of immiscible criteria shows that $CO_2$ immiscible flooding in this field could be properly applied. In the case of Onado oil producing field, since the estimated minimum miscibility pressure is lower than the reservoir pressure, it was assessed that the Onado field would be efficiently conducted for $CO_2$ miscible flooding.

Effects of different stocking density in lairage of fattening pigs in high temperatures

  • Dongcheol Song;Seyeon Chang;Jaewoo An;Sehyun Park;Kyeongho Jeon;Hyuck Kim;Jinho Cho
    • Korean Journal of Agricultural Science
    • /
    • v.50 no.4
    • /
    • pp.861-867
    • /
    • 2023
  • Lairages serve several functions, such as providing post-mortal inspections and providing a reservoir of animals to ensure the slaughter line runs efficiently. High stress lairage conditions can contribute to the accumulation of transport stress in pigs, causing poor pork quality and still stressed pigs at slaughter. The objective of this study was to investigate meat quality, blood profile and behavior changes according to lairage stocking density in in high temperature. Density treatments were as follows: LD, low density (lower than 0.5 m2/100 kg); ND, normal density (0.5 m2/100 kg to 0.83 m2/100 kg); HD, high density (higher than 0.83 m2/100 kg). Air temperature treatment was as follows: HT, high temperature (higher than 24℃). Pigs stocked with LD showed lower pH, WHC (water holding capacity), and higher DL (drip loss) and CL (cooking loss) than those stocked with HD. Pigs stocked with LD showed lower cortisol level than those stocked with HD. Therefore, Pigs exposed to high stock density (lower than 0.5 m2/100 kg) in high air temperature during pre-slaughter caused acute stress and lead to PSE (pale, soft, exudative) pork incidence. Based on obtained results, stocking of too high (lower than 0.5 m2/100 kg) density is generally not good for meat quality and animal welfare at high temperatures.

Cyanobacterial Development and Succession and Affecting Factors in a Eutrophic Reservoir (부영양 저수지에서 남조류의 발달과 천이 및 영향 요인)

  • Kim, Ho-Sub;Hwang, Soon-Jin;Kong, Dong-Soo
    • Korean Journal of Ecology and Environment
    • /
    • v.40 no.1
    • /
    • pp.121-129
    • /
    • 2007
  • This study was conducted to evaluate the causes and effects of cyanobacterial development and succession in a shallow eutrophic reservoir from March 2003 to February 2004. Phytoplankton succession, sedimentation rate, and sediment composition were analyzed. Algal bioassay also was conducted with the consideration of light, water temperature and nutrients. Cyanobacteria dominated throughout the year, except for spring season (March${\sim}$April) in which diatoms and flagellates dominated. Total cell density increased in July and November when P loading through inflows was high. Oscillatoria spp. and Aphanizomenon sp. were dominant in May and June, respectively, but replaced with Microcystis spp. in July. Thereafter, Microcystis spp. sustained until December, and again shifted to Oscillatoria spp. and Aphanizomenon sp. The dominance of Oscillatoria spp. in May was accompanied with high TN/TP ratio and the increase of water temperature and light intensity. While the dominance of Microcystis spp. was related with relatively low TN/TP ratio, ranging from 46 to 13 (average: 27). The sedimentation rate was highest in March (0.6 m $day^{-1}$) when diatoms dominated. During the period of cyanobacterial dominance, relatively high sedimentation rate was observed in May (0.4 m $day^{-1}$) and October (0.36m $day^{-1}$). C/N ratio of the sediment ranged $6{\sim}8$. Inorganic P concentration in the pore water was low when DO concentration was < 2 mg $O_2$ $L^{-1}$ in the hypolimnion, reflecting the P release from the sediment. Cyanobacterial growth rate depended on phosphorus concentration and water temperature, and high P concentration compensated for the low temperature in the growth rate. Our results suggest that the potential of cyanobacterial development and substantiality in eutrophic reservoirs be high throughout the year, as being supplied with enough P, and emphasize the consideration of sediment man. agement for the water quality improvement and algal bloom control.

Parameter Sensitivity Analysis for Spatial and Temporal Temperature Simulation in the Hapcheon Dam Reservoir (합천댐 저수지에서의 시공간적 수온모의를 위한 매개변수 민감도 분석)

  • Kim, Boram;Kang, Boosik
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.12
    • /
    • pp.1181-1191
    • /
    • 2013
  • This study have implemented finding the optimal water temperature parameter set for Hapcheon dam reservoir using CE-QUAL-W2 model. In particular the sensitivity analysis was carried out for four water temperature parameters of wind sheltering coefficient (WSC), radiation heat coefficient (BETA), light extinction coefficient (EXH2O), heat exchange coefficient at the channel bed (CBHE). Firstly, WSC, BETA, EXH2O shows relatively high sensitivity in common during April to September, and CBHE does during August to November. Secondly, as a result of identifying depth range of parameter influence, BETA and EXH2O show 0~9 m and 8~14 m which is thermocline layer close to water surface, CBHE is deep layer 12 m away from bottom. Finally, applying annual or monthly optimal parameter sets indicates that the bias between two sets does not show much differences for WSC and CBHE parameters, but BETA and EXH2O parameters show $0.20^{\circ}C$ and $0.51^{\circ}C$ of monthly average biases for two parameter sets. In particular the bias reveals to be $0.4^{\circ}C$ and $1.09^{\circ}C$ during May and August that confirms the necessity of use of monthly parameters during that season. It is claimed that the current operational custom use of annual parameters in calibration of reservoir water quality model requires the improvement of using monthly parameters.

Seasonal Variations of Nitrifying Bacteria in Agricultural Reservoir (농업용 저수지에서의 질화세균의 계절적인 변화)

  • Lee, Hee-Soon;Lee, Young-Ok
    • Korean Journal of Ecology and Environment
    • /
    • v.35 no.3 s.99
    • /
    • pp.152-159
    • /
    • 2002
  • The seasonal variations of nitrifying bacterial population sampled from 3 sites in Moon-Chon reservoir were analyzed by in situ hybridization with fluorescently labeled rRNA-targeted oligonucleotide probes from August 2000 until July 2001. In addition, physico-chemical parameters such as temperature, pH, chi-a and DOC were measured to determine correlations between those factors and the size of nitrifying bacterial populations. Total bacterial numbers varied in the range of $0.8{\sim}1.5{\times}10^6\;cells/ml$ independent of sites and had the maximal values in March at all 3 stations. The ratio of eubacteria to total bacteria ranged from 44.9% to 79.5%, and the ratio of each nitrifying bacteria to eubacterial numbers reached only $1.0{\sim}7.4%$. The variations of ammonia-oxidizing bacteria ranged from $1.1{\times}10^4$ to $3.0{\times}10^4\;cells/ml$ without noticeable peak values whereas those of nitrite-oxidizing bacteria varied in $1.3{\sim}5.7{\times}10^4\;cells/ml$ with the increasing tendency in winter regardless of the sites. Moreover it was observed that the numbers of nitrite-oxidizing bacteria were higher than those of ammonia-oxidizing bacteria. Total bacterial numbers correlated with water temperature (r = 0.355, p<0.05) and DOC (r = 0.58G, p<0.01) positively whereas nitrite-oxidizing bacteria correlated with temperature (r = -0.416, p<0.05) and pH (r = -0.568, p = 0.001) negatively. In addition, DOC represented good correlations with eubacterial numbers (r = 0.448, p<0.01). These results indicate that temperature, DOC and pH might be one of the main factors affecting variations of bacterial populations in the aquatic ecosystem. It was also suggested that FISH method is a useful tool for detection of slow growing nitrifying bacteria.

Experimental results of Stilting type Pulse Tube refrigerator with inertance tube

  • Hong, Yong-Ju;Park, Seong-Je;Kim, Hyo-Bong;Koh, Deuk-Yong;Park, Young-Don
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.118-122
    • /
    • 2003
  • Pulse tube refrigerator, which has no moving parts at its cold section, is attractive fer obtaining higher reliability, simpler construction and lower vibration than Stilting refrigerator or Gifford-McMahon refrigerator. Commonly used means to achieve optimum performance of Stilting type pulse tube refrigerator is an inertance tube. The use of inertance tube is a simple way to generate the phase shift needed to make pulse tube refrigerator operate as efficiently as Stilting refrigerator. In this study, the performance of the inertance pulse tube refrigerator (IPTR) was investigated experimentally. An in-line type IPTR consists of a linear compressor with two reciprocating pistons driven by linear motors, which makes pressure waves, a regenerator a pulse tube with the inertance tube, and a reservoir, The dynamic pressures (the compressor, pulse tube, reservior) and the temperature at the cold heat exchanger are measured to explore the dependence of the inertance tube on the performance of the IPTR. The experimental results show the dependency of cool-down characteristics, no-load temperature and amplitude of the pressures on the length and diameter of the inertance tube.

A Study for Performance Improvements in the Coaxial Type Stirling Pulse Tube Cryocooler (동축형 스털링 맥동관 냉동기의 성능개선에 관한 연구)

  • Park, S.J.;Hong, Y.J.;Kim, H.B.;Kim, Y.H.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1329-1334
    • /
    • 2004
  • The most compact and convenient pulse tube cryocooler for practical applications is the coaxial type. It can replace Stirling cryocooler without any change to the Dewar or the connection to the cooled devices. The experimental results of the coaxial inertance tube pulse tube cryocooler for cooling superconductor RF filter are presented in this paper. To find optimal conditions of inertance tube pulse tube cryocooler, no load temperature according to the variations of inertance tube volume, reservoir volume are measured, and the cool down characteristics at the particular conditions are presented. In case of the coaxial type inertance tube pulse tube refrigerator, cool down time is the lowest in the inertance tube diameter of 1.3 mm and inertance tube length of 1900 mm and lowest temperature is 112K. This results are not satisfactory for practical applications. So, We propose vacuum insulation between regenerator and pulse tube in the Stirling type coaxial pulse tube cryocooler. Stirling type coaxial pulse tube cryocooler with the vacuum insulation between regenerator and pulse tube was designed and manufactured by KIMM(Korea Institute of Machinery and Materials). The optimal conditions will be tested for Stirling type coaxial pulse tube cryocooler with the vacuum insulation between regenerator and pulse tube.

  • PDF