• Title/Summary/Keyword: research tendon

Search Result 215, Processing Time 0.023 seconds

Feasibility Study of Determining the Healing Phase of Achilles Tendon Rupture in Rats Using Optical Coherence Tomography

  • Kim, Young-Sik;Chae, Yu-Gyeong;Jeon, Min Yong;Kim, Dong Kyu;Ahn, Yeh-Chan
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.175-181
    • /
    • 2015
  • Optical coherence tomography (OCT) is a noninvasive technique for microscopic investigation of tissue. We thought that the OCT method could be a potential tool for monitoring the healing process of a tendon. In this study we used two rat models, denervated and non-denervated groups, to observe a variety of healing phases of Achilles tendon (AT) injury. We made samples of AT injury lesions, to take OCT images and to make histopathological samples of serial sectional tissue. In an OCT image the denervated rat showed no specific finding, but the non-denervated rat showed a large defect lesion that was scaffolding tissue. OCT findings combined with pathologic findings showed advantages in visualization of tendon microstructure over other imaging modalities such as MRI and US, and OCT is beneficial to making a treatment plan, especially the timing and intensity of rehabilitation. Therefore a multimodal platform using OCT for evaluation of tendon injury may be potentially useful for many applications.

Magnetic resonance imaging features of the biceps tendon rupture in a Labrador retriever dog

  • Cho, Hyunju;Choi, Hojung;Lee, Youngwon
    • Korean Journal of Veterinary Research
    • /
    • v.60 no.4
    • /
    • pp.233-236
    • /
    • 2020
  • A five-year-old spayed female Labrador retriever presented with right forelimb lameness one day earlier. Radiographs and computed tomography of the right shoulder joint revealed conspicuous enthesophytes, bone cyst, and bone fragment at the intertubercular groove. Magnetic resonance imaging showed a loss of continuity of the biceps tendon and inhomogeneous hyperintense signal of the surrounding soft tissue and moderate synovial fluid on T2- and proton density-weighted images with contrast enhancement on the postcontrast T1-weighted images. The dog was diagnosed with tenosynovitis and biceps tendon rupture with osteoarthritis based on a comprehensive evaluation of the computed tomography and magnetic resonance imaging features.

Comparison of Microbiological Safety of Porcine Grafts on Gamma Irradiation for Use of Xenografts (돼지 유래 생체 조직의 이식재 활용을 위한 방사선 조사 미생물 제어 평가)

  • Jo, Eu-Ri;Kim, Jeongsoo;Choi, Jong-il;Kim, Jae-Hun;Sung, Nak-Yun;Song, Beom-Seok;Kim, JaeKyung;Park, Jong-Heum;Lee, Ju-Woon
    • Journal of Radiation Industry
    • /
    • v.5 no.3
    • /
    • pp.279-283
    • /
    • 2011
  • This study was compared microbiological safety with gamma-irradiated porcine tendon and skin, as materials for the development of xenografts to regenerate damaged tissues and protect secondary contamination. The porcine tendon and skin were gamma-irradiated after inoculation of bacteria and virus to evaluate irradiation sensitivity of microorganisms. The result showed that the porcine tendon and skin were not different on the sensitivity of microorganisms by gamma irradiation. Bacteria inoculated in the porcine tendon and skin were confirmed that E. coli was the $D_{10}$ values of $0.32{\pm}0.082$ and $0.25{\pm}0.1kGy$ on tendon and skin, and B. subtilis was $4.00{\pm}0.312$ and $3.88{\pm}0.3kGy$ on gamma irradiation, respectively. Moreover, Virus inoculated in the porcine tendon and skin was observed that poliovirus (PV) was $6.26{\pm}0.332$ and $6.88{\pm}0.3kGy$, and porcine parvovirus (PPV) was $1.75{\pm}0.131$ and $1.73{\pm}0.2kGy$ and bovine viral diarrhoea virus (BVDV) was $3.70{\pm}0.212$ and $3.81{\pm}0.2kGy$ on gamma irradiation, respectively. Virus showed higher resistance compared to bacteria on gamma irradiation, but was not detected CPE (cytopathic effect) by virus both tendon and skin at 25 kGy, a standard dose recommended from IAEA for sterilization of medical products. Therefore, These results were considered that gamma irradiation could control effectively bacteria and virus to develop safe porcine xenograft, and apply same irradiation doses to all tissues including tendon and skin of porcine.

A Study of the Tendon Profile of a PSC Continuous Beam Able to Resist the Negative Bending Moment of Continuous Intergirders (거더 연속부의 부모멘트 제어에 효과적인 PSC 연속보의 텐던 배치에 관한 연구)

  • Kim, Eui Hun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.617-625
    • /
    • 2021
  • The problems associated with the continuous method of a domestically improved prestressed concrete (PSC) girder and the bending moment of a continuous tendon were studied. Based on the results, a continuous tendon model was proposed that can resist the negative bending moment of an intergirder. This model lowers the anchorage of the continuous tendon as far as possible under the girder, and extends the tendon section arranged under the girder. This method reduces the PS's bending moment in the middle of the span, but maximizes it in the intergirder. This continuous tendon model can offer a suitable method for continuity before manufacturing a composite, which requires a higher design bending moment in the intergirder than in the middle of the span.

Parameter Analysis for Design of Pretension Girder Bridge for Urban Maglev Transit (도시형 자기부상열차 프리텐션 거더교의 설계변수 분석)

  • Lee, Jae-Ho;Kim, Do-Hak;Kim, Seung-Hyun;Kim, Sung-Il
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.4
    • /
    • pp.515-525
    • /
    • 2016
  • Parameter analysis of a pretension girder bridge for urban maglev transit was performed to identify the main design parameters and their effect. Girder deflection at mid-span is the most important design criteria of urban maglev transit. Therefore, concrete compressive strength, girder height, girder length, and unbonded tendon length were selected as the design parameters that relate to girder deflection. In addition, tendon layout and unbonded tendon ratios were also considered as design parameters to control the top stress of the pretension girder section at the support. The analysis results show that both the girder height and length are dominant design parameters governing girder deflection, more important than compressive strength and unbounded tendon length. And, sensitivity analysis makes this study suggest design weight value. In terms of stress, a tendon layout that can satisfy the unbounded tendon rule requires an additional tendon or rebar at the upper section to control the tensile stress on top of the section. Therefore, to improve feasibility and constructability in the future, an enhanced unbonded tendon rule considering the load characteristics of the urban maglev system should be studied.

Osteogenic Potential of the Periosteum and Periosteal Augmentation for Bone-tunnel Healing

  • Youn Inchan;Suh J-K Francis;Choi Kuiwon
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.2
    • /
    • pp.101-110
    • /
    • 2005
  • Periosteum and periosteum-derived progenitor cells have demonstrated the potential for stimulative applications in repairs of various musculoskeletal tissues. It has been found that the periosteum contains mesenchymal progenitor cells capable of differentiating into either osteoblasts or chondrocytes depending on the culture conditions. Anatomically, the periosteum is a heterogeneous multi-layered membrane, consisting of an inner cambium and an outer fibrous layer. The present study was designed to elucidate the cellular phenotypic characteristics of cambium and fibrous layer cells in vitro, and to assess whether structural integrity of the tendon in the bone tunnel can be improved by periosteal augmentation of the tendon­bone interface. It was found the cells from each layer showed distinct phenotypic characteristics in a primary monolayer culture system. Specifically, the cambium cells demonstrated higher osteogenic characteristics (higher alkaline phosphatase and osteocalcin levels), as compared to the fibrous cells. Also in vivo animal model showed that a periosteal augmentation of a tendon graft could enhance the structural integrity of the tendon-bone interface, when the periosteum is placed between the tendon and bone interface with the cambium layer facing toward the bone. These findings suggest that extra care needs to be taken in order to identify and maintain the intrinsic phenotypes of the heterogeneous cell types within the periosteum. This will improve our understanding of periosteum in applications for musculoskeletal tissue repairs and tissue engineering.

Design of a Digital Signal Processing System for Analysis of Tendon Reflex Response (T-반사 응답의 분석을 위한 디지탈 신호 처리 시스템의 설계)

  • 김재국;권도철
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.221-226
    • /
    • 1996
  • Tendon reflex responses generated from mechanical stimulus had been studied for quantitative analysis of activity of tendon reflex, especially patellar tendon reflex responses are known to be a criterion for diagnosing the L3 or L4 radiculopathy. In this paper, we developed a digital signal processing system for analysis of the tendon reflex response. The system parameter, i.e., $\textit{sampling frequency, pre-amplification gain, input channel and filter bank}$ are selected by Using software switches. From the view points of flexibility, the system hardware is connected to an IBM PC for analyzing the tendon reflex parameters, amplitude, latency duration We applied the proposed system to the analysis of the patellar tendon reflex reponses. In the experiment, we measured latency, duration, amplitude of the reflex action potentials generated from vastus medialis, vastus lateralis and rectus femoris that compose quadriceps, and the measured data are analyzed througll the ANOVA test which has 5% significant level. As a result, we showed that the mean amplitude of reflex action potential at the vastus lateralis is larger than any other muscle and the mean latency of the reflex action potential at the rectus femoris is shorter than any other muscle.

  • PDF

Experimental Study on Stress Evaluation Study on Stress Evaluation of Unbonded Tendon under Ultimate Load (극한하중상태에서 비부착 긴장재의 응력평가에 관한 실험연구)

  • 임재형;문정호;이리형
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04b
    • /
    • pp.519-524
    • /
    • 1998
  • The current study is a part of series of research about the evaluation method of the unbonded tendon stress in prestressed concrete member at flexural failure. As the experimental study, a test program with 14 beams and slabs was planed to identify the contribution of each important variable. The variables are (1) the effective prestress, (2) the concrete strength, (3) the amount of tendons (4) the amount of bonded reinforcements, (5) the loading type, (6) the span/depth ratio. It was found that the tendon stress increment decreases as the effective prestress increases. Also, the contributions of concrete strength, amount of tendons, bonded reinforcements, and loading type were observed to affect on tendon stresses. However, the tendon stress increments were minimal at high values of span/depth in contrast with the ACI Code.

  • PDF

Effects of tendon damage on static and dynamic behavior of CFTA girder

  • Vu, Thuy Dung;Lee, Sang Yoon;Chaudhary, Sandeep;Kim, Dookie
    • Steel and Composite Structures
    • /
    • v.15 no.5
    • /
    • pp.567-583
    • /
    • 2013
  • Experimental studies and finite element analyses have been carried out to establish the effect of tendon damage on the structural behavior of concrete filled tubular tied arch girder (CFTA girder). The damage of tendon is considered in different stages by varying the number of damaged cables in the tendon. Static and dynamic structural parameters are observed at each stage. The results obtained from the experiments and numerical studies have been compared to validate the studies. The tendons whose damage can significantly affect the stiffness of the CFTA girder are identified by performing the sensitivity analysis. The locations in the girder which are sensitive to the tendon damage are also identified.

Two cases report of Supraspinatus Tendon Tear Treated with The Daoyin exercise program combined with Korean medicine Treatment (도인운동요법을 병행한 극상근 파열 환자 치험 2례)

  • Choi, Bongseok;Oh, Minseok
    • Journal of Haehwa Medicine
    • /
    • v.25 no.1
    • /
    • pp.27-36
    • /
    • 2016
  • Objectives : The purpose of this report is to prove the effect of The Daoyin exercise program combined with Korean medicine treatment on supraspinatus tendon tear. Methods : Two patients, diagnosed with Supraspinatus tendon tear by shoulder MRI, were treated with The Daoyin exercise program and Korean medicine treatment. VAS(Visual analog scale), ROM(Range of motion) and Physical examination were used to evaluate patients. Results of application : The Daoyin exercise program combined with Korean medicine treatment reduced shoulder pain and improved shoulder ROM of the two patients significantly. Conclusions : The Daoyin exercise program combined with Korean medicine treatment is proved to be effective treatment for reducing pain and improving shoulder ROM of supraspinatus tendon tear patients.