• Title/Summary/Keyword: requirement engineering

Search Result 3,024, Processing Time 0.042 seconds

Requirement analysis and architecture establishment for ship production monitoring system (조선소 생산공정모니터링 시스템 개발을 위한 요구사항 분석 및 아키텍처 수립)

  • Lee, Kwangkook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.9
    • /
    • pp.2079-2086
    • /
    • 2014
  • Shipbuilding production management is one of the most significant activities in productivity improvement. Shop-floor managers and production planners still do not have enough production information for shop-floor scheduling due to shortage of information sharing among them. In this research, main issues were derived from requirement analysis between production planning and shop-floor control to establish a software system architecture for ship production monitoring system(SPMS), which is developed with component based design(CBD). The proposed system's key functions cover from block shop assembly to quay outfitting stage to visualize production progress as well as to maximize production information sharing. The system will allow more reliable and accurate production information to permeate down to members of the workforce just in time.

A Novel High Rate Flocculator/Filter in Water and Wastewater Treatment (상하수처리를 위한 새로운 고효율 응집/여과 장치)

  • Vigneswaran, S.;Ngo, H.H.;Kwon, Dae-young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.2
    • /
    • pp.149-154
    • /
    • 2005
  • Conventionally used flocculation tanks require large space and high energy requirement for mixing. Static flocculators using gravel bed filter operate at a lower flow rate ($5-10m^3/m^2{\cdot}h$). Further, the cleaning of this system is difficult. A novel high rate static flocculator/filter developed at UTS packed with buoyant media such as polystyrene, polypropylene has been found to operate at higher filtration rates (30-45 $5-10m^3/m^2{\cdot}h$). They can easily be cleaned with minimal energy. Detailed experiments conducted with an artificial kaolin clay solution show that buoyant media is an excellent static flocculator in producing uniform filterable microflocs (12-15 m) even when it is operated at a high rate of 30-40 m/h. Detailed filtration experiments were conducted in a wastewater treatment plant to treat the biologically treated effluent with a floating media of depth of 120 cm. This filter was able to remove majority of phosphorus and remaining solids. It reduced significantly the fecal coliforms and fecal streptoccoci, thus requiring less amount of chlorine for disinfection. The advantage of this system is the low energy and water requirement for cleaning of filter bed. The periodic backwash adopted 30 seconds air and water and 30 seconds water cleaning every 90 minutes filter operation. Thisis equivalent to 1-2% of filtered water production. Mechanical cleaning system on the other hand, requires very low energy requirement (<1% of filtered water production).

Estimation of Agricultural Reservoir Water Storage Based on Empirical Method (저수지 관리 관행을 반영한 농업용 저수지 저수율 추정)

  • Kang, Hansol;An, Hyunuk;Nam, Wonho;Lee, Kwangya
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.5
    • /
    • pp.1-10
    • /
    • 2019
  • Due to the climate change the drought had been occurring more frequently in recent two decades as compared to the previous years. The change in the pattern and frequency of the rainfall have a direct effect on the farming sector; therefore, the quantitative estimation of water supply is necessary for efficient agricultural water reservoir management. In past researches, there had been several studies conducted in estimation and evaluation of water supply based on the irrigational water requirement. However, some researches had shown significant differences between the theoretical and observed data based on this requirement. Thus, this study aims to propose an approach in estimating reservoir rate based on empirical method that utilized observed reservoir rate data. The result of these two methods in comparison with the previous one is seen to be more fitted for both R2 and RMSE with the observed reservoir rate. Among these procedures, the method that considers the drought year data shows more fitted outcomes. In addition, this new method was verified using 15-year (2002 to 2006) linear regression equation and then compare the preceeding 3-year (1999 to 2001) data to the theoretical method. The result using linear regression equation is also perceived to be more closely fitted to the observed reservoir rate data than the one based on theoretical irrigation water requirement. The new method developed in this research can therefore be used to provide more suitable supply data, and can contribute to effectively managing the reservoir operation in the country.

PERFORMANCE OF AN OSCILLATING SUBSOILER IN BREAKIN HARD PAN

  • Bandalan, E.P.;Gupta, C.P.;Salokhe, V.M.;Niyamapa, T.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.1043-1052
    • /
    • 1993
  • Field experiments were conducted to determine the optimum combination of performance parameters of a single-shank, tractor-mounted oscillating subsoiler. Tests were conducted at frequencies of oscillation of 3.7 , 5.67, 7.58, 9.48 and 11.456Hz ; amplitudes of 18, 21, 23.5, 34 and 36.5 mm ; and forward speeds of 1.84, 2.19 and 3.42 kmph at moisture content close to the plastic limit of the soil. It was observed that there was a reduction in average draft but an a increase in average total power requirement for oscillating than non-oscillating subsoiling. The draft and power ratios were significantly affected by the forward speed, frequency and amplitude. Their combined interaction expressed in terms of the velocity ratio parameter( the ratio of peak tool velocity and forward speed) however has the strongest influence. At the same velocity ratio, the draft reduction and power increase were less at higher amplitude of oscillation . As the oscillating frequency is increased toward the soil resonance the draft requirement becomes less. For the field conditions tested. the optimum operation was obtained at an amplitude of 36.5mm, frequency of 9.48Hz and speed of 2.19 kmph with a draft ratio of 0.33 and a power ratio of only 1.24.

  • PDF

H$_{\infty}$ Control System for Tandem Cold Mills with Roll Eccentricity

  • Kim, Seung-Soo;Kim, Jong-Shik;Yang, Soon-Yong;Lee, Byung-Ryong;Ahn, Kyung-Kwan
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.45-54
    • /
    • 2004
  • In order to meet the requirement for higher thickness accuracy in cold rolling processes, it is strongly desired to have high performance in control units. To meet this requirement, we have considered an output regulating control system with a roll-eccentricity estimator for each rolling stand of tandem cold mills. Considering entry thickness variation as well as roll eccentricity as the major disturbances, a synthesis of multivariable control systems is presented based on H$\sub$$\infty$/ control theory, which can reflect the knowledge of input direction and spectrum of disturbance signals on the design. Then, to reject roll eccentricity effectively, a weight function having some poles on the imaginary axis is introduced. This leads to a non-standard H_ control problem, and the design procedures for solving this problem are analytically presented. The effectiveness of the proposed control method is evaluated through computer simulations and compared to that of the conventional LQ control and feedforward control methods for roll eccentricity.

Wideband Low-Reflection Transmission Lines for Bare Chip on Multilayer PCB

  • Ramzan, Rashad;Fritzin, Jonas;Dabrowski, Jerzy;Svensson, Christer
    • ETRI Journal
    • /
    • v.33 no.3
    • /
    • pp.335-343
    • /
    • 2011
  • The pad pitch of modern radio frequency integrated circuits is in the order of few tens of micrometers. Connecting a large number of high-speed I/Os to the outside world with good signal fidelity at low cost is an extremely challenging task. To cope with this requirement, we need reflection-free transmission lines from an on-chip pad to on-board SMA connectors. Such a transmission line is very hard to design due to the difference in on-chip and on-board feature size and the requirement for extremely large bandwidth. In this paper, we propose the use of narrow tracks close to chip and wide tracks away from the chip. This narrow-to-wide transition in width results in impedance discontinuity. A step change in substrate thickness is utilized to cancel the effect of the width discontinuity, thus achieving a reflection-free microstrip. To verify the concept, several microstrips were designed on multilayer FR4 PCB without any additional manufacturing steps. The TDR measurements reveal that the impedance variation is less than 3 ${\Omega}$ for a 50 ${\Omega}$ microstrip and S11 better than -9 dB for the frequency range 1 GHz to 6 GHz when the width changes from 165 ${\mu}m$ to 940 ${\mu}m$, and substrate thickness changes from 100 ${\mu}m$ to 500 ${\mu}m$.

Bolted T-stubs: A refined model for flange and bolt fracture modes

  • Francavilla, Antonella B.;Latour, Massimo;Piluso, Vincenzo;Rizzano, Gianvittorio
    • Steel and Composite Structures
    • /
    • v.20 no.2
    • /
    • pp.267-293
    • /
    • 2016
  • It is well known that, in order to accurately predict the behaviour of steel structures a requirement the definition of the mechanical behaviour of beam-to column joints is of primary importance. This goal can be achieved by means of the so-called component method, which, in order to obtain the whole behaviour of connections, provides to break up joints in basic components of deformability and resistance. One of the main joint components used to model bolted connections is the so-called equivalent T-stub in tension, which is normally used to predict the behaviour of bolted plates in bending starting from the behaviour of the single bolt rows. In past decades, significant research efforts have been devoted to the prediction of the behaviour of bolted T-stubs but, to date, no particular attention has been devoted to the characterization of their plastic deformation capacity. To this scope, the work presented in this paper, taking into account the existing technical literature, proposes a new theoretical model for predicting the whole behaviour up to failure of bolted T-stubs under monotonic loading conditions, including some complexities, such as the bolt/plate compatibility requirement and the bolt fracture, which are necessary to accurately evaluate the ultimate displacement. After presenting the advances of the proposed approach, a comparison between theoretical and experimental results is provided in order to verify its accuracy.

A Research on the $CO_2$ Peak Point Control According to Ventilation Rate During Sleeping (취침 시 환기횟수에 따른 $CO_2$ 피크치 제어에 관한 연구)

  • Kim, Se-Hwan;Kim, Dong-Gyu;Park, Jong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.1
    • /
    • pp.49-54
    • /
    • 2009
  • Ventilation requirement of apartment was mandated according to building equipment standards in 2006. When ventilation unit was considering for indoor air quality maintenance, we needed energy saving and efficiency ventilation control methods. This study carried out experiment of ventilation rate 0.7 adequacy. When we lived in apartment, we assumed that sleeping time was long stayed time in unconsciousness. Experiments carried out ventilation rate 0, 0.1, 0.4 and 0.7 in environment chamber from 22 o'clock to 06 o'clock, the concentration of $CO_2$, temperature and humidity rate measured. Analyzing the results, conclusions are as follows. 1) When we sleep in bedroom, ventilation rate 0.4 meet the requirements of domestic legal standards. Conform fan of similarity law, ventilation rate 0.4 reduced power cost about 80% than 0.7. 2) In generally sleeping time 8 hours, peak point control reduced running time of ventilation unit about 43% than normal control.

An Improvement Study on National Fire Safety Code of Sprinkler System for Hydraulic Calculation Application (수리계산 적용을 위한 스프링클러설비의 화재안전기준 개선방안 연구)

  • Lee, Keun-Oh;Kang, Joo-Hyeong
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.1 s.79
    • /
    • pp.7-12
    • /
    • 2007
  • There are two kinds of design process for sprinkler system. one is pipe schedule system and the other is hydraulically designed system. We have inefficient results when we design by hydraulically designed system because the design process for sprinkler system is restricted by domestic fire code. Therefore, it is essential to do an introduction of hydraulically designed system which is based on engineering for enhancing reliability and efficiency of sprinkler system. This study presents points at issue by comparing and studying design standards of sprinkler system from Korea, Japan and NFPA, and presents improvement plans of national fire safety code of sprinkler system by processing, comparing and analyzing designs according to piping schedule and hydraulically designed system about domestic objects. Installation standards of sprinkler system have to be applied not by object buildings but by hazard classification. It is hard to design an efficient sprinkler system for fire control when water supply requirement of sprinkler systems allocated according to a size of a building because the same purpose but other buildings may request more water requirement or less. We should sublate the pipe schedule system from national fire safety code and need to introduce the hydraulically designed system. The pipe schedule system presents easy access because it is based on the forecasted engineering calculations but it is applied to only small buildings like NFPA due to its low reliability.

Regional Integrity Analysis using modernized GPS, Galileo and SBAS

  • Han, Sang-Sul;Shin, Dae-Sik;Cho, Jong-Chul;Park, Chan-Sik;Jun, Hyang-Sik;Nam, Gi-Wook;Lee, Sang-Jeong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.417-421
    • /
    • 2006
  • ICAO defines performance requirements of navigation system such as accuracy, integrity, continuity and availability. The integrity is most significant performance requirement in aviation where safety of life is crucial. Many researches on this topic anticipate that GPS with SBAS or Galileo can meet APV requirements and GPS with GBAS or Galileo with GBAS will meet CAT II and III requirements. These performance expectations are based on global analysis. In this paper regional integrity analysis in Korea using various combinations of modernized GPS, Galileo and SBAS is given. The simulation results show that CAT I requirement can be met using modernized GPS and Galileo alone, however, CAT II and III are not met even augmenting SBAS because of VPL. A more efficient augmentation such as GBAS which can reduce VPL dramatically is required to meet CAT II and III in Korean region.

  • PDF