• 제목/요약/키워드: required time to signal

검색결과 518건 처리시간 0.028초

Retrieving the Time History of Displacement from Measured Acceleration Signal

  • Han, Sangbo
    • Journal of Mechanical Science and Technology
    • /
    • 제17권2호
    • /
    • pp.197-206
    • /
    • 2003
  • It is intended to retrieve the time history of displacement from measured acceleration signal. In this study, the word retrieving means reconstructing the time history of original displacement signal from already measured acceleration signal not just extracting various information using relevant signal processing techniques. Unlike extracting required information from the signal, there are not many options to apply to retrieve the time history of displacement signal, once the acceleration signal is measured and recorded with given sampling rate. There are two methods, in general, to convert measured acceleration signal into displacement signal. One is directly integrating the acceleration signal in time domain. The other is dividing the Fourier transformed acceleration signal by the scale factor of - $\omega$$^2$and taking the inverse Fourier transform of it. It turned out both the methods produced a significant amount of errors depending on the sampling resolution in time and frequency domain when digitizing the acceleration signals. A simple and effective way to convert the time history of acceleration signal into the time history of displacement signal without significant errors is studied here with the analysis on the errors involved in the conversion process.

PREDICTION OF THE DETECTION LIMIT IN A NEW COUNTING EXPERIMENT

  • Seon, Kwang-Il
    • 천문학회지
    • /
    • 제41권4호
    • /
    • pp.99-107
    • /
    • 2008
  • When a new counting experiment is proposed, it is crucial to predict whether the desired source signal will be detected, or how much observation time is required in order to detect the signal at a certain significance level. The concept of the a priori prediction of the detection limit in a newly proposed experiment should be distinguished from the a posteriori claim or decision whether a source signal was detected in an experiment already performed, and the calculation of statistical significance of a measured source signal. We formulate precise definitions of these concepts based on the statistical theory of hypothesis testing, and derive an approximate formula to estimate quickly the a priori detection limit of expected Poissonian source signals. A more accurate algorithm for calculating the detection limits in a counting experiment is also proposed. The formula and the proposed algorithm may be used for the estimation of required integration or observation time in proposals of new experiments. Applications include the calculation of integration time required for the detection of faint emission lines in a newly proposed spectroscopic observation, and the detection of faint sources in a new imaging observation. We apply the results to the calculation of observation time required to claim the detection of the surface thermal emission from neutron stars with two virtual instruments.

An Efficient Method to Track GPS L1 C/A and Galileo E1B CBOC(6,1,1/11) Signal Simultaneously using a Low Cost GPU in SDR

  • Park, Jong-Il;Park, Chansik
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제9권4호
    • /
    • pp.337-345
    • /
    • 2020
  • In this paper, an efficient signal tracking method to simultaneously track both GPS L1 C/A and Galileo E1B CBOC(6,1,1/11) using a low cost GPU is proposed. In the existing method that each GNSS signal is processed within 1 ms, more than 2 ms processing time is required in GPU to process 4 ms CBOC signal. It means that real time operation is possible if only Galileo E1B CBOC signal is concerned. But when both GPS C/A and Galileo CBOC is required, it cannot process GPS C/A signal in real time. To process 1 ms GPS C/A and 4 ms Galileo CBOC signal in real time, 4 ms Galileo CBOC signal is divided into 4 by 1 ms signal block in the proposed method. Specially, a buffer that simultaneously manages 1 ms and 4 ms signals is designed. In addition, a module that accumulates the 1 ms correlation value of the Galileo CBOC by 4 ms and passes it to the PLL and DLL is implemented. The operation and performance are evaluated with real measurements in the GPU based SDR. The experimental results show that tracking of more than 16 satellites of GPS C/A and Galileo E1B is possible using the proposed method.

Comparison of two sampling intervals and three sampling intervals VSI charts for monitoring both means and variances

  • Chang, Duk-Joon
    • Journal of the Korean Data and Information Science Society
    • /
    • 제26권4호
    • /
    • pp.997-1006
    • /
    • 2015
  • In industrial quality control, when engineers use VSI control procedure they should consider both required time to signal and switching behaviors together in the case of production process changed. Up to the present, many researchers have studied fixed sampling interval (FSI) chart and variable sampling interval (VSI) chart in the points of average number of samples to signal (ANSS) and average time to signal (ATS). However, ANSS and ATS do not provide any switching information between different sampling intervals of VSI schemes. In this study, performances of two sampling intervals VSI chart and three sampling intervals VSI chart are evaluated and compared. The numerical results show that ANSS and ATS values of two sampling intervals VSI chart and three sampling interval VSI chart are similar regardless the amount of shifts. However, the values of switching behaviors including ANSW are less efficient in three sampling intervals VSI charts than in two sampling intervals VSI chart.

션트저항을 이용한 3상 인버터의 전압 변조지수 증대 (Improvement of Modulation Index in 3-phase Inverters using Shunt Resistors)

  • 김정대;최종우
    • 전기학회논문지
    • /
    • 제67권3호
    • /
    • pp.374-382
    • /
    • 2018
  • This paper has done a hardware-based approach to increase the modulation index in 3-phase inverters, unlike the conventional software algorithm-based approaches. The minimum required time to measure the currents in a three-phase inverters with shunt resistors has also been analyzed. By the analysis, the longest time in minimum required time is AD conversion time. To shorten the minimum required time, this paper proposed a sample-and-hold(S/H) circuit implemented at the inverter current signal output to retain the current signal. When the linear operation region of an inverter with S/H was compared with that without it, the modulation index was increased by 7.8 %. Inverters with S/H circuits can employ the traditional software algorithms, such as the voltage injection method or current restoration method, and it will yield further increase the modulation index.

지연요소를 수반하는 일차계통의 패러미터 추정에 관한 연구 (A Study of Parameter Estimation for First Order System with Dead Time)

  • 하주식
    • 전기의세계
    • /
    • 제18권1호
    • /
    • pp.15-23
    • /
    • 1969
  • A lot of recent researches have shown that a Pseudo Random Binary Signal is a quite effective test signal to measure the impulse response of a plant. Generally speaking, however, such a response itself is not satisfactory to determine the appropriate control parameters or control inputs. Here, the author intends to estimate the unknown parameters of the First Order Plant with Dead Time by means of correlation method using M-sequence signal. The time constant T and the dead time L of the plant are eatimated with one tracking loop by automatically adjusting delay time .tau. of M-sequence signal according to variations of T and L. In this paper, a three level M-sequence signal is used as a test signal in order to avoid troublesome operations to calculate partial derivatives of a given performance index with respect to the parameters which are usually required in the Model Method. Several experiments with analogue computer using low pass filters as averaging circuits showed good results as expected.

  • PDF

근접영역에서의 IR 탐색기 정보를 이용한 표적적응유도 (Target Adaptive Guidance Using Near-Zone Information from IR Seeker)

  • 엄태윤;김필성
    • 한국군사과학기술학회지
    • /
    • 제5권3호
    • /
    • pp.113-119
    • /
    • 2002
  • A target adaptive guidance(TAG) algorithm is proposed employing the near-zone signal that can be measured from an infrared seeker. The guidance order is composed of a conventional PNG command and an additional command to be calculable from an additional LOS rate between a hot point of target and a required intercept point. The characteristic of the near-zone signal is similar to that of LOS rate that is inversely proportional to the square of time-to-go. Hence the proposed scheme can be applied to real systems with no estimator for time-to-go. From analysis results on the miss distance with perfect missile and perfect seeker, it follows that the proposed TAG algorithm guarantees missile to be ideally guided to the required intercept point. And it is less affected by the TAG start time and a proportional navigation ratio than other TAG schemes using a LOS rate such as a step bias or a ramp bias.

Improved Dynamic Programming in Local Linear Approximation Based on a Template in a Lightweight ECG Signal-Processing Edge Device

  • Lee, Seungmin;Park, Daejin
    • Journal of Information Processing Systems
    • /
    • 제18권1호
    • /
    • pp.97-114
    • /
    • 2022
  • Interest is increasing in electrocardiogram (ECG) signal analysis for embedded devices, creating the need to develop an algorithm suitable for a low-power, low-memory embedded device. Linear approximation of the ECG signal facilitates the detection of fiducial points by expressing the signal as a small number of vertices. However, dynamic programming, a global optimization method used for linear approximation, has the disadvantage of high complexity using memoization. In this paper, the calculation area and memory usage are improved using a linear approximated template. The proposed algorithm reduces the calculation area required for dynamic programming through local optimization around the vertices of the template. In addition, it minimizes the storage space required by expressing the time information using the error from the vertices of the template, which is more compact than the time difference between vertices. When the length of the signal is L, the number of vertices is N, and the margin tolerance is M, the spatial complexity improves from O(NL) to O(NM). In our experiment, the linear approximation processing time was 12.45 times faster, from 18.18 ms to 1.46 ms on average, for each beat. The quality distribution of the percentage root mean square difference confirms that the proposed algorithm is a stable approximation.

거리 측정 시스템의 정밀도 향상을 위한 카운터 회로의 설계 (Design of Counter Circuit for Improving Precision in Distance Measuring System)

  • 최진호
    • 한국정보통신학회논문지
    • /
    • 제24권7호
    • /
    • pp.885-890
    • /
    • 2020
  • 거리측정 시스템에서 사용되는 시간-디지털 변환회로는 시작신호와 멈춤신호 사이의 시간 간격을 이용하여 거리를 측정한다. 응답속도를 고려한 시간 간격은 일반적으로 카운터 회로를 이용하여 디지털 정보로 변환한다. 그러므로 정밀도 향상을 위해서는 높은 주파수의 클록 신호가 요구되며, 미세 거리의 측정을 위해서도 높은 주파수의 클록 신호가 필요하다. 본 논문에서는 동일한 주파수를 사용하면서도 거리 측정의 정밀도를 높이기 위한 카운터 회로를 설계하였다. 회로의 설계는 0.18㎛ CMOS 공정을 이용하였으며, 설계된 회로의 동작은 HSPICE 시뮬레이션을 통하여 확인하였다. 시뮬레이션 결과 일반적인 카운터 회로를 사용한 경우에 비해 4배의 향상된 정밀도를 얻을 수 있었다.

Switching performances of multivarite VSI chart for simultaneous monitoring correlation coefficients of related quality variables

  • Chang, Duk-Joon
    • Journal of the Korean Data and Information Science Society
    • /
    • 제28권2호
    • /
    • pp.451-459
    • /
    • 2017
  • There are many researches showing that when a process change has occurred, variable sampling intervals (VSI) control chart is better than the fixed sampling interval (FSI) control chart in terms of reducing the required time to signal. When the process engineers use VSI control procedure, frequent switching between different sampling intervals can be a complicating factor. However, average number of samples to signal (ANSS), which is the amount of required samples to signal, and average time to signal (ATS) do not provide any control statistics about switching performances of VSI charts. In this study, we evaluate numerical switching performances of multivariate VSI EWMA chart including average number of switches to signal (ANSW) and average switching rate (ASWR). In addition, numerical study has been carried out to examine how to improve the performance of considered chart with accumulate-combine approach under several different smoothing constant and sample size. In conclusion, process engineers, who want to manage the correlation coefficients of related quality variables, are recommended to make sample size as large and smoothing constant as small as possible under permission of process conditions.