• Title/Summary/Keyword: reproducibility of results

Search Result 861, Processing Time 0.037 seconds

Reproducibility of Lateral Cephalometric Landmarks According to Radiographic Image Enhancement (방사선상 enhancement 정도에 따른 측모두부방사선규격사진 계측점 설정의 재현도)

  • Ryu, Hwang-Sog;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.32 no.1 s.90
    • /
    • pp.59-69
    • /
    • 2002
  • The purpose of this study was to evaluate the reproducibility of lateral cephalometric landmarks according to radiographic image enhancement, and to contribute to the identification of cephalometric landmarks. Lateral cephalograms of ten individuals were taken and stored into computer. The images were then enhanced up to four grades by Quick Ceph Image Pro$^{TM}$ on condition that the gray-scale equalization number was 50 and the detail enhancement number was 50. After thirty two landmarks were identified on monitor images by five observers, the deviations from the mean, the distances estimated between identified points and the mean point of five identified points, were evaluated for each landmark at each enhancement grade. Through the statistical analysis, following results were obtained. 1. In case of unenhanced radiographic images, the inter-observer reproducibility of the landmarks showed a large variation. 2. The comparison of deviation from the mean according to the degree of radiographic image enhancement for each landmark showed that the inter-observer reproducibility was significantly different at 5 landmarks. 3. The landmark of pterygomaxillary fissure showed higher reproducibility at enhancement grade 1 and 2 images than at unenhanced images. So did the landmark of posterior nasal spine at enhancement grade 1 images, and the landmark of menton at enhancement grade 2, 3 and 4 images respectively. The above results suggest that the reproducibility of some landmarks can be increased by radiographic image enhancement during the identification of the lateral cephalometric landmarks on the monitor.

Comparative Evaluation of Reproducibility for Spatio-temporal Rainfall Distribution Downscaled Using Different Statistical Methods (통계적 공간상세화 기법의 시공간적 강우분포 재현성 비교평가)

  • Jung, Imgook;Hwang, Syewoon;Cho, Jaepil
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.1
    • /
    • pp.1-13
    • /
    • 2023
  • Various techniques for bias correction and statistical downscaling have been developed to overcome the limitations related to the spatial and temporal resolution and error of climate change scenario data required in various applied research fields including agriculture and water resources. In this study, the characteristics of three different statistical dowscaling methods (i.e., SQM, SDQDM, and BCSA) provided by AIMS were summarized, and climate change scenarios produced by applying each method were comparatively evaluated. In order to compare the average rainfall characteristics of the past period, an index representing the average rainfall characteristics was used, and the reproducibility of extreme weather conditions was evaluated through the abnormal climate-related index. The reproducibility comparison of spatial distribution and variability was compared through variogram and pattern identification of spatial distribution using the average value of the index of the past period. For temporal reproducibility comparison, the raw data and each detailing technique were compared using the transition probability. The results of the study are presented by quantitatively evaluating the strengths and weaknesses of each method. Through comparison of statistical techniques, we expect that the strengths and weaknesses of each detailing technique can be represented, and the most appropriate statistical detailing technique can be advised for the relevant research.

Construction reproducibility of a composite tooth model composed of an intraoral-scanned crown and a cone-beam computed tomography-scanned root

  • Lim, Seung-Weon;Moon, Ryu-Jin;Kim, Min-Seok;Oh, Min-Hee;Lee, Kyung-Min;Hwang, Hyeon-Shik;Kim, Tae-Woo;Baek, Seung-Hak;Cho, Jin-Hyoung
    • The korean journal of orthodontics
    • /
    • v.50 no.4
    • /
    • pp.229-237
    • /
    • 2020
  • Objective: To evaluate the construction reproducibility of a composite tooth model (CTM) composed of an intraoral-scanned crown and a cone-beam computed tomography (CBCT)-scanned root. Methods: The study assessed 240 teeth (30 central incisors, 30 canines, 30 second premolars, and 30 first molars in the maxillary and mandibular arches) from 15 young adult patients whose pre-treatment intraoral scan and CBCT were available. Examiner-Reference (3 years' experience in CTM construction) and Examiners-A and Examiner-B (no experience) constructed the individual CTMs independently by performing the following steps: image acquisition and processing into a three-dimensional model, integration of intraoral-scanned crowns and CBCT-scanned teeth, and replacement of the CBCT-scanned crown with the intraoral-scanned crown. The tooth axis angle in terms of mesiodistal angulation and buccolingual inclination of the CTMs constructed by the three examiners were measured. To assess the construction reproducibility of CTMs, intraclass correlation coefficient (ICC) assessments were performed. Results: The ICC values of mesiodistal angulation and buccolingual inclination among the 3 examiners showed excellent agreement (0.950-0.992 and 0.965-0.993; 0.976-0.994 and 0.973-0.995 in the maxillary and mandibular arches, respectively). Conclusions: The CTM showed excellent construction reproducibility in mesiodistal angulation and buccolingual inclination regardless of the construction skill and experience levels of the examiners.

Comparative Evaluation of Reproducibility of Knee Joint Collateral Ligament Stress-radiogram Using Telometer (Telometer를 이용한 슬관절 측부인대 Stress-radiogram의 재현성 비교평가)

  • Jeong, Jin-Man;Jeong, Seong-Bin;Kim, Sang-Hyun;Lee, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.539-543
    • /
    • 2018
  • Telometer is a supplementary filming device that improves the image quality and minimizes the motion unsharpness by enhancing the reproducibility of diagnostic images because it applies constant pressure (force) to the affected area. The stress-radiogram which is widely used to provide the o-bjective quantitative stability of knee ligament is reported in literature as the most suitable method to evaluate the stability of ligament and it is advised to use the Telometer. In order to evaluate the image reproducibility of the Telometer, the collateral ligament which is the most vulnerable among the ligaments consisting of the knee joint, the stress-radiogram was executed in the order of the Telometer, the push pull gauge and the conventional stress radiogram. Then, SPSS (Statistical Package for the Social Science) for Windows 22.0 was used for comparison and evaluation. According to the results of comparison and evaluation, the standard errors and standard deviations became smaller in the order of the Telometer, the push pull gauge, the conventional stress radiogram while the image reproducibility was higher in the order of the Telometer, the push pull gauge, the conventional stress radiogram. Therefore, it is considered that the use of the TELOS for stress-radiogram would enhance the quality of patient diagnostic images and the work performance of radiologists.

Evaluation of Reliability of Automatic System for Measuring Sizing Degree by Basis Weight Variation of Paper (종이 평량의 차이에 따른 자동 사이즈도 측정 시스템의 신뢰성 평가)

  • Lee, Ji-Young;Kim, Chul-Hwan;Lee, Ji-Young;Nam, Hye-Gyeong;Lee, Gyeong-Sun;Jo, Hu-Seung;Park, Hyung-Hun
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.46 no.3
    • /
    • pp.11-19
    • /
    • 2014
  • Reliability of the novel automatic system capable of measuring both St$\ddot{o}$ckigt sizing degree and contact angle at a time was evaluated through the calculation of its repeatability and reproducibility based on TAPPI Standard Method T 1200. As the basis weight of paper specimen increased, the repeatability and reproducibility of the automatic system became more improved than those from Hercules sizing test and contact angle test designated on TAPPI Standard Method T 530 and T 558. The more improved repeatability and reproducibility implies that a single tester can obtain the similar results under similar test conditions in spite of repetitive testing using the automatic system, and likewise that multiple testers can respectively reproduce similar data without big variation from the same paper specimen using the automatic system. In conclusion, this study is greatly meaningful in having developed the world's first automatic system to measure both St$\ddot{o}$ckigt sizing degree and contact angle simultaneously with excellent repeatability and reproducibility.

Clinical Comparison Of Manual Probe With Florida Probe In Adult Periodontitis (성인형 치주염 환자에 있어 manual probe의 Florida probe의 임상적 비교)

  • Yu, Hyang-Mi;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.244-254
    • /
    • 1996
  • The periodontal probe is a commonly used instrument to assess periodontal conditions. And so, there has been many studies to develop the accuracy and reproducibility of the periodontal probe. The purpose of this study was to compare two different periodontal probes for measurement reliability and time required to use in subjects with moderate periodontitis. It was done after evaluating reproducibility of probing depth by stent guiding for a Manual probe and a Florida probe in subjects with healthy periodontal condition. The results were as follows 1. In experiment to evaluate the reproducibility of probing depth by stent guiding for a Manual probe and Florida probe in subjects with healthy periodontal condition, there was no major significant difference between intraprobe and interprobe relationships. 2. There were reduced probing measuremint error by using the Florida probe for posterior teeth and by using the Manual probe for anterior teeth of subjects with moderate periodontitis. 3. At proximal area, there was higher measurement error by using the Manual probe than the Florida probe. 4. The mean of pocket depth measurement using Manual probe was signifi cantly higher than that using Florida probe(p<0.05). With increasing pocket depth, interprobe difference increased and reproducibility reduced. 5. There was no significant difference in time required to use between Manual probe and Florida probe(p<0.05). 6. There was slight probing measurement difference between Manual probe and Florida probe at different site, but both probes have similar degrees of reproducibility and similar time required to probe.

  • PDF

Three-dimensional evaluation on the repeatability and reproducibility of dental scanner-based digital models (치과용 스캐너로 채득한 디지털 모형의 반복성 및 재현성에 관한 3차원적 평가)

  • Lee, Gyeong-Tak;Kim, Jae-Hong;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.34 no.3
    • /
    • pp.213-220
    • /
    • 2012
  • Purpose: The aim of this study was to determine the repeatability and reproducibility of two dental scanners. Methods: The master die and the stone replicas(Kavo, Germany) were digitized in touch-probe scanner(Incise, Renishaw, UK), white light scanner(Identica, Medit, Korea) to create 3-dimensional surface-models. The number of points in the point clouds from each reading were calculated and used as the CAD reference model(CRM). Discrepancies between the points in the 3-dimensional surface models and the corresponding CRM were measured by a matching-software(Power-Inspect R2, Delcam Plc, UK). The t-student test for one samples were used for statistical analysis. Results: The reproducibility of both scanner was within $3{\mu}m$, based on mean value. The mean value between measurements made directly on the touch probe scanner digital models and those made on the white light scanner digital models was $2.20-2.90{\mu}m$, and was statistically significant(P<0.05). Conclusion: With respect to adequate data acquisition, the reproducibility of dental scanner differs. Three-dimensional analysis can be applied to differential quality analysis of the manufacturing process as well as to evaluation of different analysis methods.

Enhancing the Reproducibility of a Photoacoustic Signal Using a Minimum-volume Cell (최소 부피 광음향 셀의 광음향 신호 재현성 향상에 관한 연구)

  • Kim, Kyong-Seok;Lee, Kew-Seung;Ahn, Hong-Gyu;Lee, Eung-Jang;Kim, Dae-Kyu;Park, Seung-Han
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.2
    • /
    • pp.77-82
    • /
    • 2011
  • Reproducibility obtained by a minimum-volume cell for photoacoustic (PA) signals is strongly dependent upon the sealing materials and sealing efficiency. Therefore, we have proposed, designed, and constructed an apparatus to enhance the sealing efficiency, and we have examined the reproducibility of amplitude and phase of PA signals with a minimum-volume cell. In particular, we have measured the PA signal as a function of modulation frequency for various rubber O-rings by using our apparatus. The results show that a silicon rubber O-ring can improve the reproducibility of the PA signal and phase by up to 53.4% and 80.4%, respectively, compared to that obtained by using the conventional sealing material, vacuum grease.

Application of Bias-Correction and Stochastic Analogue Method (BCSA) to Statistically Downscale Daily Precipitation over South Korea (남한지역 일단위 강우량 공간상세화를 위한 BCSA 기법 적용성 검토)

  • Hwang, Syewoon;Jung, Imgook;Kim, Siho;Cho, Jaepil
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.6
    • /
    • pp.49-60
    • /
    • 2021
  • BCSA (Bias-Correction and Stochastic Analog) is a statistical downscaling technique designed to effectively correct the systematic errors of GCM (General Circulation Model) output and reproduce basic statistics and spatial variability of the observed precipitation filed. In this study, the applicability of BCSA was evaluated using the ASOS observation data over South Korea, which belongs to the monsoon climatic zone with large spatial variability of rainfall and different rainfall characteristics. The results presented the reproducibility of temporal and spatial variability of daily precipitation in various manners. As a result of comparing the spatial correlation with the observation data, it was found that the reproducibility of various climate indices including the average spatial correlation (variability) of rainfall events in South Korea was superior to the raw GCM output. In addition, the needs of future related studies to improve BCSA, such as supplementing algorithms to reduce calculation time, enhancing reproducibility of temporal rainfall patterns, and evaluating applicability to other meteorological factors, were pointed out. The results of this study can be used as the logical background for applying BCSA for reproducing spatial details of the rainfall characteristic over the Korean Peninsula.

Analysis of Reproducibility of Constitutions dy IGM(InyoungGigu Macjin:人迎氣口脈法) and Agreement Rate between Sasang Constitutions dy QSCCII and Constitutions by IGM (인영기구맥법을 이용한 한의사 A씨의 체질감별 재현성 및 QSCCII체질과의 일치율 분석)

  • Park Soo-Jin;Kwon Young-Kyu
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.20 no.1
    • /
    • pp.262-267
    • /
    • 2006
  • We verified the reproducibility of constitution by IGM and the agreement rate between sasang constitution by QSCCII and constitution by IGM. We analyzed the results of 64 subject who were judged as identical sasang constitution by repeated QSCC II. First, we compared the two results of constitutions by IGM hat peformed by one O.M.D(Oriental Medicine Doctor) at an interval of one year. Second, we examined hypothesis established by one O.M.D, that is about relation of constitutions by IGM and QSCCII, such as I type-Taeeumin, II type-Soyangin and III type-Soeumin in constitutions. There were no statistical significances in reproducibility of constitution by IGM. Although there was a tendency of relevance of sasang constitution by QSCC II with constitution by IGM, there was no statistical significance. Hypothesis that is established by clinical experiences must be verified by an effective statistical method. And there is a necessity to complement the method including mechanical measurements about constitution classification which are performed by a diagnosis relying on individual intuition.