• Title/Summary/Keyword: replacement ratio selection

Search Result 18, Processing Time 0.03 seconds

Replacement Algorithm Selection Mechanism Considering File Size for Web Cache Server

  • Sontisiri, Tanasun;Sopechoke, Pawin;Thipchaksurat, Sakchai;Varakulsiripunth, Ruttikorn
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1084-1089
    • /
    • 2004
  • This paper describes the improvement of web cache server by scoping in replacement algorithm of data which are collected from the clients. We have found that each replacement algorithm is suitable for each type of data in the web pages. Therefore, we introduce the mechanism to select the replacement algorithm depending on the size of data called the Replacement Algorithm Selection Mechanism (RASM). RASM allows the web cache server to have the suitable replacement algorithm for each type of data. As the result, the byte hit ratio of web cache server can be increased and the congestion in the network can be alleviated.

  • PDF

Video Compression using Characteristics of Wavelet Coefficients (웨이브렛 계수의 특성을 이용한 비디오 영상 압축)

  • 문종현;방만원
    • Journal of Broadcast Engineering
    • /
    • v.7 no.1
    • /
    • pp.45-54
    • /
    • 2002
  • This paper proposes a video compression algorithm using characteristics of wavelet coefficients. The proposed algorithm can provide lowed bit rate and faster running time while guaranteeing the reconstructed image qualify by the human virtual system. In this approach, each video sequence is decomposed into a pyramid structure of subimages with various resolution to use multiresolution capability of discrete wavelet transform. Then similarities between two neighboring frames are obtained from a low-frequency subband which Includes an important information of an image and motion informations are extracted from the similarity criteria. Four legion selection filters are designed according to the similarity criteria and compression processes are carried out by encoding the coefficients In preservation legions and replacement regions of high-frequency subbands. Region selection filters classify the high-frequency subbands Into preservation regions and replacement regions based on the similarity criteria and the coefficients In replacement regions are replaced by that of a reference frame or reduced to zero according to block-based similarities between a reference frame and successive frames. Encoding is carried out by quantizing and arithmetic encoding the wavelet coefficients in preservation regions and replacement regions separately. A reference frame is updated at the bottom point If the curve of similarity rates looks like concave pattern. Simulation results show that the proposed algorithm provides high compression ratio with proper Image quality. It also outperforms the previous Milton's algorithm in an Image quality, compression ratio and running time, leading to compression ratio less than 0.2bpp. PSNR of 32 dB and running tome of 10ms for a standard video image of size 352${\times}$240 pixels.

Replacement and Lifetime Production Traits: Effect of Non-genetic Factors and Sire Evaluation

  • Singh, S.;Khanna, A.S.;Singh, R.P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.1
    • /
    • pp.11-15
    • /
    • 2002
  • The present investigation was undertaken to study the effects of non-genetic factors and association among replacement and lifetime production traits. The data on 542 Holstein Friesian cows maintained during 1975-98 at State Cattle Breeding Project, Sector III, Hisar, were utilized. The average sex-ratio, abnormal births, mortality, culling and replacement rates on total calf born and total female calf born basis were 51.62, 8.50, 17.52, 31.05, 22.78 and 51.41 per cent, respectively. The study revealed that a minimum of 4 to 5 progenies are required per cow over its lifetime to replace itself. It indicated that each cow should produce a minimum of 2 female calves during its life so as to replace herself before being lost. The least-squares means for productive herd life, longevity and lifetime production were $1439.32{\pm}87.64$ and $2419.18{\pm}8.25$ days and $11317.95{\pm}913.15kg$, respectively. The heritability estimates for all replacement traits were very low indicating that sire selection may bring no desirable change in these traits. Heritability estimates were $0.178{\pm}0.157$, $0.288{\pm}0.184$ and $0.096{\pm}0.195$ for corresponding lifetime production traits. Breeding values and ranking of sires were generated for replacement and lifetime production traits to estimate the rank correlations between these traits. Moderate desirable rank correlations were obtained between replacement rate and lifetime production traits indicating that sires proven on the basis of milk production are also expected to have better replacement rate.

An application and development of an activity lesson guessing a population ratio by sampling with replacement in 'Closed box' ('닫힌 상자'에서의 복원추출에 의한 모비율 추측 활동수업 개발 및 적용)

  • Lee, Gi Don
    • The Mathematical Education
    • /
    • v.57 no.4
    • /
    • pp.413-431
    • /
    • 2018
  • In this study, I developed an activity oriented lesson to support the understanding of probabilistic and quantitative estimating population ratios according to the standard statistical principles and discussed its implications in didactical respects. The developed activity lesson, as an efficient physical simulation activity by sampling with replacement, simulates unknown populations and real problem situations through completely closed 'Closed Box' in which we can not see nor take out the inside balls, and provides teaching and learning devices which highlight the representativeness of sample ratios and the sampling variability. I applied this activity lesson to the gifted students who did not learn estimating population ratios and collected the research data such as the activity sheets and recording and transcribing data of students' presenting, and analyzed them by Qualitative Content Analysis. As a result of an application, this activity lesson was effective in recognizing and reflecting on the representativeness of sample ratios and recognizing the random sampling variability. On the other hand, in order to show the sampling variability clearer, I discussed appropriately increasing the total number of the inside balls put in 'Closed Box' and the active involvement of the teachers to make students pay attention to controlling possible selection bias in sampling processes.

A Study on the Optimal Concrete Mix-proportion Selection of PHC-pile by Using of Air-cooled Blast Furnace Slag Coarse Aggregate (괴재 고로슬래그 굵은 골재 사용에 따른 PHC-Pile용 콘크리트 최적 배합 도출에 관한 연구)

  • Jeon, In Ki;Lee, Joo Hun;Park, Yong Kyu;Kim, Hyun Woo;Yoon, Ki Won
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.270-271
    • /
    • 2014
  • In this study, a replacement ratio of blast furnace slag coarse aggregate and a water binder ratio by an optimum combination of PHC file was investigated. As a results, the target strength 78.5MPa was altogether satisfied in a mix proportion 28-G100-SG0 and W/B ratio 26 %. The surface rupture was generated in 28-G0-SG100 combination after curing with the autoclave. According to the result of measuring the ingredient, the majority were the MgOH2 hydrate.

  • PDF

The Mixing Control Range Selection of Concrete according to High Volume Mineral Admixture Replacement (광물질 혼화재 다량 치환에 따른 콘크리트의 배합 조정 범위 선정)

  • Yang, Seong-Hwan;Yoon, Gi-Won;Hur, Kab-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.3
    • /
    • pp.282-290
    • /
    • 2013
  • In this study, the adjustment range of mixture factor with replacement mineral admixture was reviewed to secure the mixture change data of high volume concrete compared to general concrete. When changing the concrete mix to high volume concrete within the universal concrete mixing, the adjustment range of mixture to ensure optimum quality is as follows. Unit-water content is $20{\sim}30kg/m^3$ downward. Fine aggregate ratio dropped by approximately 1% when W/B was reduced by 5%, and it is reduced by approximately 0.12% when there is a 5% increase in the total replacement rate. When the FA replacement rate was increased by 5%, the AE agent was approximately 20% to 30% higher compared with the conventional one. When the FA and BS replacement rate rose by 5%, W/B was reduced by about 1 to 4%.

Optimizing cement replacement with rice husk ash and eggshell ash for enhanced mechanical properties of geopolymer concrete: A comparative study with and without admixture

  • Yashwanth Pamu;Venkata Sarath Pamu;Praveen Samarthi;Mahesh Kona
    • Computers and Concrete
    • /
    • v.33 no.6
    • /
    • pp.707-724
    • /
    • 2024
  • This paper proposes a study of cement replacement with rice husk ash (RHA) and eggshell ash (ESA) for enhanced mechanical properties of geopolymer (GP) concrete with and without admixture. The main objective is to investigate the mechanical properties of GP with various replacement levels of Pozzolana Portland cement by RHA and ESA. The GP resistance to durability is examined and impact of ash materials on concrete's durability performance is determined. The environmental benefits of using agricultural waste materials in GP manufacturing minimize cement usage and CO2 emissions. The goal is to assess value of RHA-ESA of building material, paving stones for structures to lessen environmental impact. The novelty lies in use of ESA and RHA as partial replacements for cement and investigation of admixtures to enhance concrete properties, and reduce environmental impact. The research contributes by introducing a novel approach to reducing cement consumption by using ESA and RHA to address environmental concerns. It also explores the potential benefits of admixtures improving concrete performance and reducing environmental pollution. A study is carried with and without impacts of admixture to find compressive strength of GP cubes. The cement has been replaced by RHA and ESA in the range of (2.5%+7.5%, 5%+5%, 7.5%+2.5) by weight of cement for M20 mix. The compressive strength (CS) and split tensile strength (STS) at 7days, 14 days and 28 days is obtained as 21 N/mm2 at 7.5%RHA+2.5%ESA and 2.3 at 7.5%RHA+2.5%ESA, 24 N/mm2 at 7.5%RHA+2.5%ESA and 2.3 at 7.5%RHA+2.5%ESA, 28 N/mm2 at 7.5%RHA+2.5%ESA and 2.8 at 7.5%ESA respectively with normal curing condition.

Long-Term Result of Tricuspid Valve Replacement (삼첨판막 치환술의 장기성적)

  • Lim, Cheong;Kang, Moon-Chul;Kim, Kyung-Hwan;Kim, Ki-Bong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.680-685
    • /
    • 2001
  • Background: Tricuspid valve replacement is very rarely performed procedure and its long-term result is not yet satisfactory. Moreover, it is not well known whether bioprosthesis or mechanical prosthesis is the best selection for artificial valve. We reviewed 72 cases of tricuspid valve replacements in 71 patients between January 1989 and December 1998, trying to analyze the overall results and risk factors for mortality and morbidity. Material and Method: Average age of the patients at the time of operation was 42$\pm$13 years(range 16 to 65 years) and the sex ratio of male versus female was 32/39. Primary diagnosis consisted of 50 cases of aquired valvular heart disease and 18 cases of congenital heart disease, such as Ebstein’s anomaly. 4 cases had isolated tricuspid valve regurgitation. Implanted valves were 69 mechanical prosthesis and 3 bioprosthesis. Concomitant mitral or aortic valve replacements were performed in 50 cases. One patient received concomittant pulmonary valve replacement. Result: There were 7(9.72%) operative deaths and 7(13.0%) late deaths. Actuarial survival at 10 years was 59.2$\pm$7.2%. Prosthetic tricuspid valve thrombosis occurred 11 times in 5 patients. Reoperation for prosthetic tricuspid valve failure was performed in 1 patient. In this case, examination of the explanted prostheses showed that the tricuspid stenosis was the result of valve thrombosis. Among the 47 survivors, 46 patients(98%) were in functional class I or II. Conclusion: In our ten-year experience of tricuspid valve replacement, mortality and morbidity were satisfactory. Mechanical prosthesis in tricuspid position showed comparable clinical results as bioprosthesis.

  • PDF

Pericardial Versus Porcine Valves for Surgical Aortic Valve Replacement

  • Hong Ju Shin;Wan Kee Kim;Jin Kyoung Kim;Joon Bum Kim;Sung-Ho Jung;Suk Jung Choo;Cheol Hyun Chung;Jae Won Lee
    • Korean Circulation Journal
    • /
    • v.52 no.2
    • /
    • pp.136-146
    • /
    • 2022
  • Background and Objectives: There still are controversies on which type between bovine pericardial and porcine valves is superior in the setting of aortic valve replacement (AVR). This study aims to compare clinical outcomes of AVR using between pericardial or porcine valves. Methods: The study involved consecutive 636 patients underwent isolated AVR using stented bioprosthetic valves between January 2000 and May 2016. Of these, pericardial and porcine valves were implanted in 410 (pericardial group) and 226 patients (porcine group), respectively. Clinical outcomes including survival, structural valve deterioration (SVD) and trans-valvular pressure gradient were compared between the groups. To adjust for potential selection bias, inverse probability treatment weighting (IPTW) was conducted. Results: The mean follow-up duration was 60.1±50.2 months. There were no significant differences in the rates of early mortality (3.1% vs. 3.1%; p=0.81) and SVD (0.3%/patient-year [PY] vs. 0.5%/PY; p=0.33) between groups. After adjustment using IPTW, however, landmark mortality analyses showed a significantly lower late (>8 years) mortality risk in pericardial group over porcine group (hazard ratio [HR], 0.61; 95% confidence interval, [CI] 0.41-0.90; p=0.01) while the risks of SVD were not significantly difference between groups (HR, 0.45; 95% CI, 0.12-1.70; p=0.24). Mean pressure gradient across prosthetic AV was lower in the Pericardial group than the Porcine group at both immediate postoperative point and latest follow-up (p values <0.001). Conclusions: In patients undergoing bioprosthetic surgical AVR, bovine pericardial valves showed superior results in terms of postoperative hemodynamic profiles and late survival rates over porcine valves.

Clinical Evaluation of St.Jude Medical Valve Replacement (St.Jude 기계판막을 이용한 인공심장판막 치환의 외과적 고찰)

  • Jin, Ung;Rha, Suk-Joo;Cho, Kyu-Do;Kim, Chi-Kyung;Jo, Keon-Hyon;Wang, Young-Pil;Lee, Sun-Hee;Kwak, Moon-Sub;Kim, Se-Wha;Lee, Hong-Kyun
    • Journal of Chest Surgery
    • /
    • v.27 no.4
    • /
    • pp.272-280
    • /
    • 1994
  • Total 400 St.Jude Medical Bileaflet Valves were implanted in 336 pts from January 1983 to June 1993; 64 were aortic, 205 were mitral, 64 were double valve and 3 were tricuspid position. The follow up period extended from 6 months to 10 years[mean 24.3 months]. Male to female ratio was 1:1.7. There were total 27 deaths[cardiac related 20, cardiac non-related 7]. Overall mortality was 2.9%/pt-yr. There were 10 early deaths[3.0%] and 10 late cardiac related deaths [3.0%]. Prosthetic valve related complications occurred in 19 patients[5.7%] and among them, seven died; four died of thromboembolic events, two died of anticoagulants therapy related hemorrhagic complications and one died of bacterial endocarditis. NYHA class improved significantly especially in aortic valve replacement and double valve replacement. In AVR cases, the mean NYHA was 2.8 preoperatively and 1.3 postoperatively. And in DVR cases, 3.3 preoperatively and 2.2 postoperatively. The decision to employ a particular prosthesis was made according to the anticipated or known complications of the valve. The St.Jude Medical Valve retains all the hazards of other mechanical valves, most notably, thromboembolism. But the hemodynamic performance of St.Jude Medical Valve compared most favorably with other substitute valves in many reports. 0ur experience didn`t show any differences compared other authors in terms of valve related complication. So we concluded St. Jude Medical Valve can be primarily considered in the selection of artificial valve except in the patients when the usage of anticoagulant therapy is contraindicated.

  • PDF