• 제목/요약/키워드: repeated sequence

검색결과 181건 처리시간 0.026초

Assessment and Interpretation of Bioequivalence for Two Drug Formulations using Crossover Design

  • Ko, Seoung-gon;Oh, Hyun-Sook
    • Communications for Statistical Applications and Methods
    • /
    • 제6권2호
    • /
    • pp.601-610
    • /
    • 1999
  • Crossover design is officially except for special occasions recommended by KFDA and FDA for assessing Bioequivalence between two drugs one for reference and the other for innovator. Such design is regarded as a special case of latin square split-polt or repeated measurement design and its main difference with other designing methods is that each subject in an experiment is exposed two drugs in sequence. Therefore general statistical analysis is not suitable since the model for this experiment includes carryover effect in addition to period and sequence effect. in this paper analysis for crossover model with two drugs and its interpretation are mainly discussed and an example is given for illustration.

  • PDF

페이딩과 재밍 환경에서 LDPC 부호화된 OFDM/DS 시스템의 성능 (Performance of LDPC Coded OFDM/DS Under Fading and Jamming Environment)

  • 서동철;이우찬;김종훈
    • 한국군사과학기술학회지
    • /
    • 제11권5호
    • /
    • pp.23-33
    • /
    • 2008
  • In this paper, we verify the performance of LDPC coded OFDM/DS system by Monte-Carlo simulation of BER on Eb/No. The simulation results show that LDPC coded OFDM/DS has a strong anti-jamming characteristic over pulse-noise jammer and partial-band noise jammer. The performance of LDPC coded OFDM/DS system is evaluated on both faded waveforms and non-faded waveforms. For non-faded waveforms, high coding gain is attained due to LDPC, even when waveforms have short PN sequence and JSR is only 5dB. Especially, the increase in the repeated number of LDPC decoding enhances coding gain. However, faded waveforms cannot achieve sufficient average effect when PN sequence is short. High coding gain of faded waveforms can be achieved by extending length of PN sequence. In addition, we compare LDPC coded OFDM/DS system with Convolutional coded OFDM/DS system. The simulation results illustrate that when LDPC coded OFDM/DS system with short PN sequence has sufficient average effects, the system shows lower BER than Convolutional coded OFDM/DS system with long PN sequence.

흰쥐에 있어서 톨루엔 흡입노출이 시간경과에 따른 혈중 톨루엔농도 및 행동변화에 미치는 영향 (The Effects of Toluene Inhalation on Blood Toluene Concentration in Time Sequence and Behavioral Change in Rats)

  • 백승경;노일협
    • 약학회지
    • /
    • 제40권5호
    • /
    • pp.545-549
    • /
    • 1996
  • Male Sprague-Dawley rats were exposed to the toluene at 3,000${\pm}$200ppm via inhalation for two hours in the single inhalation group and three weeks by two hours per day, six da ys per week in the repeated inhalation group. The blood toluene concentration in the repeated inhalation group was significantly lower than that in the single inhalation group after 210 and 240 minutes of exposure. The peak concentration of blood toluene was 58.13${\pm}$4.63${\mu}$g/ml in the single inhalation group and 54.24${\pm}$6.87mcg/ml in the repeated at the end of 120 minutes of the exposure. The behavioral change of rats for the initial 30 minutes of the toluene inhalation showed mildly increased movement and excitement but remained calm and inhibitory behaviors after that period; more inhibitory behaviors in the single inhalation group compared with the repeated inhalation group. In open-field test, after the termination of the toluene inhalation, no difference had been statistically observed between the toluene inhalation group and the control group in ambulation, rearing, preening and grooming.

  • PDF

MPEG-2 비디오 스트림 편집시의 비트율 제어 (Image Retrieval using Adaptable Weighting Scheme on Relevance Feedback)

  • 윤범식;노홍진;최윤식
    • 방송공학회논문지
    • /
    • 제5권2호
    • /
    • pp.188-198
    • /
    • 2000
  • 편집 과정에서의 언더플로우의 문제는 이미 이전에 페이드-인 시퀀스를 삽입하여 해결하는 방법이 연구된 것이 있으나, 이는 원하지 않는 영상신호를 임의로 삽입한다는 점이 문제였다. 본 연구에서는 압축영역에서 수행할 수 있는. 시퀀스의 압축율에 따른 적절한 재양자화를 통한 기법을 적용하여 이러한 페이드-인 시퀀스 삽입 방법에서와 같은 문제점 없이 언더플로우를 해결하였다. 제안된 방법은 본래의 움직임 예측 영상에 재양자화에 의한 에러를 보상하여 재양자화로 인하여 발생하는 GOP 전체로의 영상에러의 흐름에 의한 화질 열화를 방지하여 PSNR에서 약 0.5~1dB 화질이 향상되었음이 실험 결과 확인되었다.

  • PDF

카라테 구미테 정면 지르기의 동작수행시간에 따른 운동학적 시퀀스 패턴 (Kinematic Sequence Patterns according to Movement Time of Choku-tsuki in Karate Kumite)

  • Kim, Tae-Whan;Kim, Mi-Sun;Kim, Joo-Nyeon
    • 한국운동역학회지
    • /
    • 제30권3호
    • /
    • pp.225-234
    • /
    • 2020
  • Objective: The purpose of this study was to investigate the kinematic sequence patterns according to movement times during Karate choku-tsuki. Method: Ten Korea national Karate athletes participated in this study. Participants asked to perform jodan and chudan choku-tsuki. 30 infrared cameras were used to measure angular kinematic of elbow, shoulder, trunk, pelvis, hip, knee, ankle. Results: The two-way repeated measures ANOVA revealed significant effects for the joints (p<.05). But no significant effect for the movement time and interaction of joints x movement time existed for the kinematic sequence variables. Conclusion: For karate kumite players to reduce the movement time of punch, it is necessary to train kinematic sequences that allow each joint to rotate at a relatively similar timing.

가변 원형 베일러의 결속 기구 제어 장치 개발 (Development of a Tying-Unit Controller for a Variable Chamber Round Baler)

  • 김종언;김경욱
    • Journal of Biosystems Engineering
    • /
    • 제25권5호
    • /
    • pp.341-350
    • /
    • 2000
  • This study was conducted to develop a control unit for a tying device of a variable chamber round baler. The work process of the tying device was thoroughly analyzed and the control sequence was established according to the work process. Based on this control sequence, a control unit using an 8 bit microprocessor AT 89C52 as a CPU was developed. The driving circuit to control the actuator motion was developed and the PWM method was used to regulate the velocity of the actuator. On the front panel of the control unit, indicators were also installed to show the operations being conducted. A prototype of the developed control unit was manufactured and tested. A total of 50 complete cycles of the control sequence was repeated and no failure was observed. It was evaluated that the developed control unit has an excellent performance and can be used practically for variable chamber round balers.

  • PDF

선형혼합모형을 활용한 생물학적 동등성 분석 (Bio-Equivalence Analysis using Linear Mixed Model)

  • 안형미;이영조;유경상
    • 응용통계연구
    • /
    • 제28권2호
    • /
    • pp.289-294
    • /
    • 2015
  • 생동성 시험과 같은 임상약리학분야의 연구는 일반적으로 한 개체 내에서 반복하여 측정된 자료구조를 사용하므로 선형혼합모형을 이용하여 분석하는 것이 보편적이다. 이러한 모형에서 랜덤효과는 개체 내 관측 자료 사이의 상관관계를 설명하고, 공분산행렬은 개체-내 변동을 설명한다. 생동성 분석은 두 약물의 약동학적 변수인 Cmax와 AUC의 기하평균비에 대한 90% 신뢰구간이 동등성 한계인 [0.8, 1.25] 범위에 드는지 알아보는 분석으로, 고정효과에는 시기, 순서군, 치료효과를, 랜덤효과에는 개체효과를 가지는 선형혼합모형을 이용하여 분석한다. 이러한 분석이 적용된 실제 예를 살펴보기 위하여 레보플록사신 연구의 자료를 활용하였다.

LED-ID 시스템을 위한 효율적인 OFDM 프레임 동기화 방식 (Efficient OFDM Frame Synchronization Scheme for LED-ID Systems)

  • 김경호;박영식;황유민;김진영
    • 한국전자파학회논문지
    • /
    • 제25권4호
    • /
    • pp.411-417
    • /
    • 2014
  • 본 논문에서는 LED-ID(Identification) 시스템을 위한 효율적인 프레임 동기화 방식을 제안한다. 프레임 동기화는 OFDM(Orthogonal Frequency Division Multiplexing) 시스템의 정상 동작을 위한 필수적인 절차이다. LED-ID 시스템 환경에서는 Bernoulli-Gaussian 잡음이 고려되어진다. OFDM 프레임 동기화 성능을 향상시키기 위해, 시간 영역에서 OFDM 신호에 반복 직교 골드 시퀀스(ROGS: Repeated Orthogonal Gold Sequence)를 추가했다. ROGS의 전력 레벨은 LED-ID 시스템의 정상 동작에 영향을 주지 않는다. ROGS의 우수한 자기상관 및 상호상관 성능 특성으로 인하여 임펄스 잡음 때문에 간섭이 있는 LED-ID 시스템 채널에서 프레임 동기화는 성공적으로 이루어진다.

반복배열된 토마토 phenylalanine ammonia-Iyase(p AL X1, PAL X2) 유전자의 구조해석 (Structural Analysis of Repeated Tomato Phenylalanine Ammonia-Lyase Gene (PAL X1, PAL X2))

  • 이신우;여윤수
    • Applied Biological Chemistry
    • /
    • 제42권1호
    • /
    • pp.34-38
    • /
    • 1999
  • 토마토의 genome내에는 적어도 5개 이상의 PAL유전자 좌가 존재한다는 사실을 이 등(1992)이 이미 genomic Southern blot hybridization으로 확인하여 보고하였다. 그러나 본 연구에서 제작한 genomic DNA libraries를 대상으로 검색한 결과 기존에 보고된 PAL유전자 이외에 약 15 kb 와 10 kb에 해당하는 큰 EcoRI 단편을 확보 할 수 있었다. 이들 단편을 BamHI, HindIII등 9종의 제한효소를 사용하여 Southern blot hybridization을 행한 결과 PAL X1의 경우는 모든 효소에 대하여 2개의 단편이 hybridization 되었으며, 특히 BamHI으로 절단하여 얻은 3개의 단편중 두 개는 PAL5 유전자의 exon 2 부위에서 취한 oligomer(18 mer)와 primer extension 반응이 진행되어서 약 200 bp의 PAL유전자와 아주 높은 상동성을 갖는 염기서열이 확인되었다. 따라서 PAL X1유전자는 2 copy의 유전자가 나란히 존재하거나 아니면 염색체 재배열이 진행된 것으로 추정된다. 이러한 결과는 적어도 7개 이상의 PAL유전자 좌가 토마토 염색체내에 존재하는 것으로 사료된다.

  • PDF

효모염색체내에 다양한 유전자발현 cassette의 반복적 integration을 위한 system 구축 (System for Repeated Integration of Various Gene Expression Cassettes in the Yeast Chromosome)

  • 김연희
    • 생명과학회지
    • /
    • 제28권11호
    • /
    • pp.1277-1284
    • /
    • 2018
  • 본 연구에서는 효모염색체내에 다양한 유전자 발현 cassette를 도입하기 위해 Cre/loxP system을 가진 repeated yeast integrative plasmid (R-YIp)를 구축하였다. R-YIp는 반복적으로 형질전환체를 선별할 수 있는 selective marker (CgTRP1)와 loxP 서열, 그리고 integration을 위한 목적서열을 함유하고 있어 같은 염색체의 동일한 위치에 여러 개의 유전자 발현 cassette를 도입하는 것이 가능하다. 따라서 xylan/xylose 대사에 관련된 endoxylanase (XYLP), ${\beta}$-xylosidase (XYLB), xylose reductase (GRE3) 그리고xylitol dehydrogenase (XYL2)의 효모염색체내에 도입을 시도하였다. 먼저 XYLP, XYLB, GRE3그리고 XYL2 유전자의 효율적인 발현을 위한 promoter를 선별하기 위해 pGMF-GENE과 pAMF-GENE plasmid를 구축하였고, 각 유전자들의 발현에 GAL10 promoter가 적합함을 확인하였다. 다음으로 GAL10p-GENE-GAL7t cassette를 가진 pRS-GENE plasmid (R-YIp)를 구축하여, 반복적 integration 과정과 selective marker의 제거를 통해 각각의 R-YIps를 효모 7번염색체에 순차적으로 도입하였다. R-YIp system을 통해 효모염색체내에 도입된 유전자들은 모두 안정적으로 발현되었고, 활성형의 재조합효소를 생산함을 확인할 수 있었다. 따라서 다수의 외래유전자를 효모염색체내 도입함에 있어 selective marker와 숙주세포 선택의 한계를 R-YIp system을 통해 어느 정도 극복할 수 있을 것이라 기대한다.