• Title/Summary/Keyword: repeated measurements.

Search Result 439, Processing Time 0.025 seconds

Evaluation of repeated measurement stability of dentition type of maxillary anterior tooth: an in vitro study (상악 전치의 치열 형태에 따른 스캔 반복 측정 안정성 평가: in vitro 연구)

  • Park, Dong-In;Son, Ho-Jung;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.41 no.3
    • /
    • pp.211-217
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate the repeated measurement stability of scans related to dentition type. Methods: A normal model and the crowding and diastema models are also duplicated using duplicating silicon. After that, a plaster model is made using a plaster-type plaster on the duplicate mold, and each model is scanned 5 times by using an extraoral scanner. The gingival part and molar part were deleted from the 3D STL file data obtained through scanning. Using the 3D stl file obtained in this way, data is nested between model groups. Thereafter, RMS values obtained were compared and evaluated. The normality test of the data was performed for the statistical application of repeated measurements with dentition type, and the normality was satisfied. Therefore, the one-way ANOVA test, which is a parametric statistical method, was applied, and post-tests were processed by the Scheffe method. Results: The average size of each RMS in the Normal, Diastema, and Crowding groups was Normal> Crowding> Diastema. However, the standard deviation was in the order of Crowding> Normal> Diastema. The average value of each data is as follows. Diastema model was the smallest ($5.51{\pm}0.55{\mu}m$), followed by the crowding model ($12.30{\pm}2.50{\mu}m$). The normal model showed the maximum error ($13.23{\pm}1.06{\mu}m$). Conclusion: There was a statistically significant difference in the repeatability of the scanning measurements according to the dentition type. Therefore, you should be more careful when scanning the normal intense or crowded dentition than scanning the interdental lining. However, this error value was within the range of applicable errors for all clinical cases.

Evaluation of accuracy of 3D reconstruction images using multi-detector CT and cone-beam CT

  • Kim, Mi-Ja;Huh, Kyung-Hoe;YI, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.42 no.1
    • /
    • pp.25-33
    • /
    • 2012
  • Purpose : This study was performed to determine the accuracy of linear measurements on three-dimensional (3D) images using multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). Materials and Methods : MDCT and CBCT were performed using 24 dry skulls. Twenty-one measurements were taken on the dry skulls using digital caliper. Both types of CT data were imported into OnDemand software and identification of landmarks on the 3D surface rendering images and calculation of linear measurements were performed. Reproducibility of the measurements was assessed using repeated measures ANOVA and ICC, and the measurements were statistically compared using a Student t-test. Results : All assessments under the direct measurement and image-based measurements on the 3D CT surface rendering images using MDCT and CBCT showed no statistically difference under the ICC examination. The measurements showed no differences between the direct measurements of dry skull and the image-based measurements on the 3D CT surface rendering images (P>.05). Conclusion : Three-dimensional reconstructed surface rendering images using MDCT and CBCT would be appropriate for 3D measurements.

Accuracy, Precision, and Validity of Fever Detection using Non-invasive Temperature Measurement in Adult Coronary Care Unit Patients with Pulmonary Catheters (폐동맥관을 부착하고 있는 심장수술 환자에 대한 비침습적 체온측정 방법의 정확도, 정밀도 및 발열감별 타당도)

  • Joo, Ga-Eul;Sohng, Kyeong-Yae
    • Journal of Korean Academy of Nursing
    • /
    • v.42 no.3
    • /
    • pp.424-433
    • /
    • 2012
  • Purpose: To investigate the accuracy, precision and validity of fever detection of tympanic membrane (TM), temporal artery (TA) and axillary temperature (AT) compared with pulmonary artery temperature (PA). Methods: Repeated-measures design was conducted for one year on 83 adult cardiac care unit patients with pulmonary artery catheters after open heart surgery. Sequential temperature measurements were taken three times at 20-minute intervals. Accuracy, precision, repeatability, and validity of fever detection were analyzed. Results: Mean pulmonary artery temperature was $37.04^{\circ}C$ (SD $0.70^{\circ}C$). The mean (SD) offsets from PA, with the mean reflecting accuracy and SD reflecting precision, were $-1.31^{\circ}C$ ($0.75^{\circ}C$) for TA, $-0.20^{\circ}C$ ($0.24^{\circ}C$) for TM, and $-0.97^{\circ}C$ ($0.64^{\circ}C$) for AT. Percentage of pairs with differences within ${\pm}0.5^{\circ}C$ was 9.6% for TA, 19.7% for AT, and 91.6% for TM. Repeated measurements with all three methods had mean SD values within $0.04^{\circ}C$. Sensitivity, specificity, and positive and negative predictive values of tympanic measurements were 0.76, 1.0, and 1.0, and 0.90, respectively. Conclusion: Results show that TM best reflects PA, and is most consistent, accurate, and precise. AT tends to underestimate PA, and TA is least accurate and precise. Therefore tympanic membrane measurement is a reliable alternative to other non-invasive methods of measuring temperatures.

Measurements of Thermal Expansion Coefficients in GRP Pipe (GRP 복합관의 열팽창계수 측정)

  • Oh, Jin-Oh;Yoon, Sung-Ho
    • Composites Research
    • /
    • v.25 no.1
    • /
    • pp.26-30
    • /
    • 2012
  • This study was focused on the measurement of thermal expansion coefficients for GRP pipe through strain gage circuits. First of all, thermal expansion coefficients of aluminum beam were measured to examine the validity of the suggested method by using various types of strain gage circuits. Thermal expansion coefficients of GRP pipes along axial and hoop directions were measured to investigate the effect of the location of strain gages, number of repeated measurements, and strain gage types with different thermal expansion coefficients on the thermal strains and the repeatability of measured results. According to the results, thermal expansion coefficients of GRP pipes along hoop direction were lower than those along axial direction due to the constraint effect of reinforced glass fibers on thermal strains along hoop direction. As measurements were repeated, thermal expansion coefficients of GRP pipes were slightly increased, but the degree of increase became smaller. Finally, the same thermal expansion coefficients were obtained irrespective of different types of strain gages with different thermal expansion coefficients if thermal strains of strain gages were compensated by using reference compensation specimen.

Comparison of cone-beam computed tomography cephalometric measurements using a midsagittal projection and conventional two-dimensional cephalometric measurements

  • Jung, Pil-Kyo;Lee, Gung-Chol;Moon, Cheol-Hyun
    • The korean journal of orthodontics
    • /
    • v.45 no.6
    • /
    • pp.282-288
    • /
    • 2015
  • Objective: This study investigated whether it is possible to use a two-dimensional (2D) standard in three-dimensional (3D) analysis, by comparing the angles and lengths measured from a midsagittal projection in 3D cone-beam computed tomography (CBCT) with those measured by 2D lateral cephalometric radiography (LCR). Methods: Fifty patients who underwent both LCR and CBCT were selected as subjects. CBCT was reoriented in 3 different methods and the measuring-points were projected onto the midsagittal plane. Twelve angle values and 8 length values were measured on both LCR and CBCT and compared. Results: Repeated measures analysis of the variance revealed statistically significant differences in 7 angular and 5 linear measurements among LCR and 3 types of CBCT (p < 0.05). Of these 12 measurements, multiple comparisons showed that 6 measurements (ANB, AB to FH, IMPA, FMA, Co-Gn, Go-Me) were not significantly different in pairwise comparisons. LCR was significantly different from 3 types of CBCT in 3 angular (SN to FH, interincisal angle, FMIA) and 2 linear (S-Go, Co-ANS) measurements. The CBCT method was similar for all measurements, except for 1 linear measurement, i.e., S-N. However, the disparity between the mean values for all parameters was within the range of clinical measurement error. Conclusions: 3D-CBCT analysis, using midsagittal projection, is a useful method in which the 2D-LCR normative values can be used. Although the measurements changed with reorientation, these changes were not clinically significant.

Study on a 4-Week Recovery Test of Sweet Bee Venom after a 13-Week, Repeated, Intramuscular Dose Toxicity Test in Sprague-Dawley Rats

  • Kang, Hyunmin;Lim, Chungsan;Lee, Seungbae;Kim, Byoungwoo;Kwon, Kirok;Lee, Kwangho
    • Journal of Pharmacopuncture
    • /
    • v.17 no.2
    • /
    • pp.18-26
    • /
    • 2014
  • Objectives: This study was performed to check for reversibility in the changes induced by a 13-week, repeated, dose toxicity test of Sweet Bee Venom (SBV) in Sprague-Dawley (SD) rats. Methods: Fifteen male and 15 female SD rats were treated with 0.28 mg/kg of SBV (high-dosage group) and the same numbers of male and female SD rats were treated with 0.2 mL/kg of normal saline (control group) for 13 weeks. We selected five male and five female SD rats from the high-dosage group and the same numbers of male and female SD rats from the control group, and we observed these rats for four weeks. We conducted body-weight measurements, ophthalmic examinations, urinalyses and hematology, biochemistry, histology tests. Results: (1) Hyperemia and movement disorder were observed in the 13-week, repeated, dose toxicity test, but these symptoms were not observed during the recovery period. (2) The rats in the high-dose group showed no significant changes in weight compared to the control group. (3) No significant differences in the ophthalmic parameters, urine analyses, complete blood cell counts (CBCs), and biochemistry were observed among the recovery groups. (4) No changes in organ weights were observed during the recovery period. (5) Histological examination of the thigh muscle indicated cell infiltration, inflammation, degeneration, necrosis of muscle fiber, and fibrosis during the treatment period, but these changes were not observed during the recovery period. The fatty liver change that was observed during the toxicity test was not observed during the recovery period. No other organ abnormalities were observed. Conclusion: The changes that occurred during the 13-week, repeated, dose toxicity test are reversible, and SBV can be safely used as a treatment modality.

Visual Measurement of Rotational Displacements by Using Two Different Moire Fringes Simultaneously Generated by Repeated Sinusoidal Gratings (반복사인격자에서 동시에 생기는 두 가지 무아레 무늬를 이용한 회전변위의 가시적 측정)

  • Jeong, Youn-Hong;Oh, Jeong-Hyo;Jo, Jae-Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.4
    • /
    • pp.302-309
    • /
    • 2008
  • We present the precise visual measurement method of rotational displacements using two different moire fringes simultaneously generated by repeated sinusoidal gratings. We investigate the variation of moire fringes depending on rotational displacements through computer simulation and experiment using a rotator in detail. The moire fringes are composed of the wide linear fringe part with a long period and the narrow linear fringe part with a short period. These parts are superior to the angle detection of more than 12 degrees and less than 12 degree, respectively. Additionally, the method can be visually used in the determination of the rotational direction by observing the moire fringe's direction.

Bankruptcy Prediction Model with AR process (AR 프로세스를 이용한 도산예측모형)

  • 이군희;지용희
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.26 no.1
    • /
    • pp.109-116
    • /
    • 2001
  • The detection of corporate failures is a subject that has been particularly amenable to cross-sectional financial ratio analysis. In most of firms, however, the financial data are available over past years. Because of this, a model utilizing these longitudinal data could provide useful information on the prediction of bankruptcy. To correctly reflect the longitudinal and firm-specific data, the generalized linear model with assuming the first order AR(autoregressive) process is proposed. The method is motivated by the clinical research that several characteristics are measured repeatedly from individual over the time. The model is compared with several other predictive models to evaluate the performance. By using the financial data from manufacturing corporations in the Korea Stock Exchange (KSE) list, we will discuss some experiences learned from the procedure of sampling scheme, variable transformation, imputation, variable selection, and model evaluation. Finally, implications of the model with repeated measurement and future direction of research will be discussed.

  • PDF

Measurements of Extracellular Excitatory Amino Acid Neurotransmitter Levels in Corpus Striatum of Toluene Inhaled Rat by Microdialysis (톨루엔 흡입 흰쥐의 선조체에서 미세투석법을 이용한 세포외성 흥분성 아미노산 신경전달물질의 측정)

  • Baeck, Seung-Kyung;Kim, Hae-Kyu;Kim, Cheol-Min
    • YAKHAK HOEJI
    • /
    • v.42 no.1
    • /
    • pp.95-100
    • /
    • 1998
  • Male Sprague-Dawley rats were exposed to the toluene at 3,000${\pm}$200ppm via inhalation for two hours (single inhalation group), three weeks by two hours per day, six days per wee k (repeated inhalation group). We examined the level of excitatory amino acids of the extracellular neurotransmitter within the corpus striatum of rats by using in vivo microdialysis. Aspartate (Asp) and glutamate (Glu) of excitatory amino acid neurotransmitters were generally decreased in the inhalation groups compared with the control group, and more significantly decreased in the repeated inhalation group than in the single inhalation group except that Asp was increased from 60 min after the beginning of the inhalation to 30 min after the termination.

  • PDF

Validation of a new three-dimensional imaging system using comparative craniofacial anthropometry

  • Naini, Farhad B.;Akram, Sarah;Kepinska, Julia;Garagiola, Umberto;McDonald, Fraser;Wertheim, David
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.23.1-23.8
    • /
    • 2017
  • Background: The aim of this study is to validate a new three-dimensional craniofacial stereophotogrammetry imaging system (3dMDface) through comparison with manual facial surface anthropometry. The null hypothesis was that there is no difference between craniofacial measurements using anthropometry vs. the 3dMDface system. Methods: Facial images using the new 3dMDface system were taken from six randomly selected subjects, sitting in natural head position, on six separate occasions each 1 week apart, repeated twice at each sitting. Exclusion criteria were excess facial hair, facial piercings and undergoing current dentofacial treatment. 3dMDvultus software allowed facial landmarks to be marked and measurements recorded. The same measurements were taken using manual anthropometry, using soluble eyeliner to pinpoint landmarks, and sliding and spreading callipers and measuring tape to measure distances. The setting for the investigation was a dental teaching hospital and regional (secondary and tertiary care) cleft centre. The main outcome measure was comparison of the craniofacial measurements using the two aforementioned techniques. Results: The results showed good agreement between craniofacial measurements using the 3dMDface system compared with manual anthropometry. For all measurements, except chin height and labial fissure width, there was a greater variability with the manual method compared to 3D assessment. Overall, there was a significantly greater variability in manual compared with 3D assessments (p < 0.02). Conclusions: The 3dMDface system is validated for craniofacial measurements.