• 제목/요약/키워드: repeated measurements

검색결과 439건 처리시간 0.029초

Evaluation of the accuracy of linear and angular measurements on panoramic radiographs taken at different positions

  • Nikneshan, Sima;Sharafi, Mohamad;Emadi, Naghmeh
    • Imaging Science in Dentistry
    • /
    • 제43권3호
    • /
    • pp.191-196
    • /
    • 2013
  • Purpose: This study assessed the accuracy of linear and angular measurements on panoramic radiographs taken at different positions in vitro. Materials and Methods: Two acrylic models were fabricated from a cast with normal occlusion. Straight and $75^{\circ}$ mesially and lingually angulated pins were placed, and standardized panoramic radiographs were taken at standard position, at an $8^{\circ}$ downward tilt of the occlusal plane compared to the standard position, at an $8^{\circ}$ upward tilt of the anterior occlusal plane, and at a $10^{\circ}$ downward tilt of the right and left sides of the model. On the radiographs, the length of the pins above (crown) and below (root) the occlusal plane, total pin length, crown-to-root ratio, and angulation of pins relative to the occlusal plane were calculated. The data were subjected to repeated measures ANOVA and LSD multiple comparisons tests. Results: Significant differences were noted between the radiographic measurements and true values in different positions on both models with linear (P<0.001) and those with angulated pins (P<0.005). No statistically significant differences were observed between the angular measurements and baselines of the natural head posture at different positions for the linear and angulated pins. Conclusion: Angular measurements on panoramic radiographs were sufficiently accurate and changes in the position of the occlusal plane equal to or less than $10^{\circ}$ had no significant effect on them. Some variations could exist in the pin positioning (head positioning), and they were tolerable while taking panoramic radiographs. Linear measurements showed the least errors in the standard position and $8^{\circ}$ upward tilt of the anterior part of the occlusal plane compared to other positions.

Accuracy of inter-arch measurements performed on digital models generated using two types of intraoral scanners: Ex vivo study

  • Yoo, Jo-Kwang;Kang, Yoon-Koo;Lee, Su-Jung;Kim, Seong-Hun;Moon, Cheol-Hyun
    • 대한치과의사협회지
    • /
    • 제58권4호
    • /
    • pp.194-205
    • /
    • 2020
  • Objective: The purpose of this study was to evaluate the accuracy of the inter-arch relationship of digital models generated using two types of intraoral scanners. Methods: In total, 34 plaster model samples were used. Two corresponding digital models were created using two types of intraoral scanners. A total of 15 variables were measured. The plaster model was directly measured using a digital caliper, while the digital models were measured using a software. The accuracy of the measurements was evaluated using repeated measures analysis of variance and the Friedman test. Results: Among the 15 measurements, 6 measurements[Overjet, Overbite, DZ_11-41 (Distance between the gingival zenith of maxillary right central incisor and mandibular right central incisor), DZ_16-46 (Distance between the gingival zenith of maxillary right first molar and mandibular right first molar), DZ_13-33 (Distance between the gingival zenith of maxillary right canine and mandibular left canine), and DZ_23-43 (Distance between the gingival zenith of maxillary left canine and mandibular right canine)]showed statistically significant differences, with DZ_23-43 showing the largest difference of 0.18 mm. The other measurements showed no statistically significant differences. Conclusions: Regardless of the type of scanner used for preparation, digital models can be used as clinically acceptable alternatives to conventional plaster models.

  • PDF

외복사근과 다열근에 대한 초음파 영상과 표면 근전도 측정방법의 신뢰도와 타당도 (Reliability and Validity of Ultrasound Imaging and sEMG Measurement to External Abdominal Oblique and Lumbar Multifidus Muscles)

  • 김창용;최종덕;김선엽;오덕원;김진경
    • 한국전문물리치료학회지
    • /
    • 제18권1호
    • /
    • pp.37-46
    • /
    • 2011
  • The purpose of this study was to investigate intra-rater reliability and determine the validity of electromyography (EMG) measurements to represent muscle activity and ultrasonography (US) to represent muscle thickness during manual muscle testing (MMT) to external abdominal oblique (EO) and lumbar multifidus (MF). Twenty healthy subjects were recruited for this study and asked to perform MMT at differing levels. The subjects' muscle activity using EMG was measured by a ratio to maximum voluntary contraction (MVC) and root mean square (RMS) methods. The subjects' muscle thickness using US was measured by raw muscle thickness and change ratio of thickness to maximum (MVC) or resting condition. In three trials, measurements were performed on each subject by one examiner. The intra-rater reliability of measurements of EMG and US to EO and MF was calculated using intra-class coefficients. The intra-rater reliability of all measurements was excellent (ICC=.75~.98) in EMG and US. The conduct validity was calculated by one-way ANOVA with repeated measurements to compare whether the EMG and US measurements were different between MMT at different levels. There was only a significant difference between all grades at %MVC thickness measurement of US. These results suggest that a %MVC thickness measurement of US was a more sensitive and discriminate in all manual muscle testing grades. This information will be useful for the selection of US measurement and analysis methods in clinics.

고온초전도 BSCCO 2223 선재간의 초전도 접합부 제조연구 (Fabrication of superconducting Joints Between PIT Processed BSCCO 2223 Tapes by Single and Multiple Press & reaction Annealing)

  • 유재무;고재웅;정형식
    • 연구논문집
    • /
    • 통권27호
    • /
    • pp.175-181
    • /
    • 1997
  • Superconducting joints between Bi-2223/Ag tapes are fabricated by a press & reaction anneal and a multiple press & anneal. The silver sheath was mechanically or chemically removed from one side of each tape without altering the superconducting core. The exposed superconducting core of the two tapes were brought into contact and pressed so as to form a lap joint. The joined tapes were then subjected to a series of different thermomechanical treatments to achieve optimum heat treatment condition. The result from transport measurements shows that critical current ($I_c$) transmitting through joined area reaches 9A, approximately 60% of the current capacity of the tapes themselves. The critical current through joined area was improved by repeated press and reaction annealing. Measurements of the current-voltage relationship were made with several configuration of the voltage probes to characterize the critical current variation and I-V curve along the joint. Also discussed are microstructural aspects of the superconducting joint.

  • PDF

Bayesian Parameter :Estimation and Variable Selection in Random Effects Generalised Linear Models for Count Data

  • Oh, Man-Suk;Park, Tae-Sung
    • Journal of the Korean Statistical Society
    • /
    • 제31권1호
    • /
    • pp.93-107
    • /
    • 2002
  • Random effects generalised linear models are useful for analysing clustered count data in which responses are usually correlated. We propose a Bayesian approach to parameter estimation and variable selection in random effects generalised linear models for count data. A simple Gibbs sampling algorithm for parameter estimation is presented and a simple and efficient variable selection is done by using the Gibbs outputs. An illustrative example is provided.

지연성 근육통(delayed onset muscle soreness)에 대한 경피선경자극(transcutaneous electrical nerve stimulation)의 효과 (Effects of Transcutaneous Electrical Nerve Stimulation on Delayed Onset Muscle Soreness)

  • 남기석;이윤주;김종만
    • 한국전문물리치료학회지
    • /
    • 제4권3호
    • /
    • pp.70-83
    • /
    • 1997
  • The purpose of this study was to determine the effects of transcutaneous electrical nerve stimulation(TENS) on delayed onset muscle soreness(DOMS). Twenty males performed eccentric exercise of the elbow flexor. Subjects were randomly assigned to one of three groups: 1) a group ($n_1$=7) that received low frequency TENS (7 Hz), 2) a group ($n_2$=7) that received high frequency TENS (500 Hz), 3) a control group ($n_3$=6) that received no treatment. DOMS was induced in a standardised fashion in the non-dominant elbow flexor of all subjects by repeated eccentric exercise. Treatments were applied immediately following exercise and again at 24 hours and at 48 hours after. Subjects attended on three consecutive days for treatment and measurement of elbow flexion, extension and resting angle(universal goniometer), and pain(Visual Analogue Scale; VAS) on a daily basis. Measurements were taken after treatment. Analysis of results using repeated measures analysis of variance(ANOVA) and post hoc tests were as follows: 1) there were between groups differences in pain value at 48 hours after (p<0.05), 2) one-way ANOVA with repeated measurement for pain, resting angle, flexion angle and extension angle revealed significant differences within low frequency TENS group, 3) one-way ANOVA with repeated measurement for flexion angle revealed significant difference within high frequency TENS group.

  • PDF

A 90-Day Inhalation Toxicity Study of Ethyl Formate in Rats

  • Lee, Mi Ju;Kim, Hyeon-Yeong
    • Toxicological Research
    • /
    • 제33권4호
    • /
    • pp.333-342
    • /
    • 2017
  • Ethyl formate, a volatile solvent, has insecticidal and fungicidal properties and is suggested as a potential fumigant for stored crop and fruit. Its primary contact route is through the respiratory tract; however, reliable repeated toxicological studies focusing on the inhalation route have not been published to date. Therefore, the present study was conducted to investigate the safety of a 90-day repeated inhalation exposure in rats. Forty male and 40 female rats were exposed to ethyl formate vapor via inhalation at concentrations of 0, 66, 330, and 1,320 ppm for 6 hr/day, 5 days a week for 13 weeks. Clinical signs, body weights, food consumption, urinalysis, hematologic parameters, serum chemistry measurements, organ weights, necropsy, and histopathological findings were compared between the control and ethyl formate-exposed groups. Locomotor activity decreased during exposure and recovered afterward in male and female rats exposed to 1,320 ppm ethyl formate. Body weight and food consumption continuously decreased in both sexes exposed to 1,320 ppm ethyl formate from week 1 or 3 compared with the control values. The increases in adrenal weight and decreases in thymus weight were noted in both sexes exposed to ethyl formate at 1,320 ppm. Degeneration, squamous metaplasia of olfactory epithelium in the nasopharyngeal tissue, or both were noted in the male and female rats at 1,320 ppm and female rats at 330 ppm ethyl formate. Taken together, our results indicate that ethyl formate-induced changes were not observed in male and female rats at 330 and 66 ppm, respectively. This indicates that exposure to ethyl formate at concentrations below 66 ppm for 90 days is relatively safe in rats. This is the first report of a full-scale repeated inhalation toxicity assessment in rats and could contribute to controlling occupational environmental hazards related to ethyl formate.

전방머리자세 대상자에게 어깨관절 멀리건테이핑 적용이 손목굽힘근의 근활성도와 파악력에 미치는 영향 (The Effects of Shoulder Mulligan Taping and Repeated Measurements on Wrist Flexor Muscle Activity and Grip Strength in Forward Head Posture)

  • 오강오;박수형;김동우;백용현;최수홍
    • 대한정형도수물리치료학회지
    • /
    • 제24권2호
    • /
    • pp.1-7
    • /
    • 2018
  • Background: This study was carried out to investigate the effect of mulligan taping group and repeated measurement group on muscle activity and grip strength of adult with forward head posture. Methods: Thirty adults with forward head posture were randomly assigned to each of 15 mulligan taping and repeat measurement groups. The mulligan taping group measured the pre-test and post-test muscle activity and the grip strength three times and compared the mean values. The repeat group was repeatedly measured and measured before and after the experiment, The collected data were analyzed using SPSS statistical program. Results: There was no significant difference between mulligan taping group and repeated measurement group in changes of muscle activity. There was a significant difference between mulligan taping group and repeated measurement group in changes of grip strength. Conclusions: Mulligan taping was applied to an adult with forward head posture, there was no significant change in muscle activity of flexor carpi radialis and palmaris longus, but it seems to improve hand function by re-aligned of nearby muscles by maintaining scapular stability.

Sprague-Dawley 랫드를 이용한 땃두릅나무 열수추출물 분말의 단회 경구투여 독성시험 및 4주 반복 경구투여 용량 결정 시험 (Single Oral Dose Toxicity Test and Four Weeks Repeated Oral Dose Determination Test of Oplopanax elatus (Nakai) Nakai Hydrothermal Extract Powder in Sprague-Dawley Rats)

  • 유남호;권용수;천현수;안규섭;김혜진;류현열;이소민;송경석;박병준;김명조
    • 생약학회지
    • /
    • 제50권3호
    • /
    • pp.205-218
    • /
    • 2019
  • This study was conducted to investigate the toxicity symptoms and approximate lethal dose (ALD) of Oplopanax elatus (Nakai) Nakai hydrothermal extract powder by single oral dose toxicity and 4 weeks of repeated oral dose determination. The Sprague-Dawley (SD) male and female rats were treated with 1,250 (low- dosage group), 2,500 (medium- dosage group) and 5,000 (high- dosage group) mg/kg. In the single oral dose toxicity test, no dead animals and toxic symptoms were observed during the experiment. And there were no related with anomalies in normal weight changes and autopsy results. In the four-week repeated oral dose determination test, no death animals and toxicity symptoms were observed during the experiment, and there were no abnormal results in weight changes, feed and negative intake measurements. Results of eye examination, urinalysis, hematological values and serum biochemical values, gross findings and absolute organ were not of singularity. These result demonstrated that no toxic symptoms were observed by the test substance Oplopanax elatus (Nakai) Nakai hydrothermal extract powder under this test condition, and the non-toxic content is determined to be 5,000 mg/kg/day.

한의학 변수들의 반복측정시 변동량에 대한 수학적 모형 제안 및 교육에의 적용 가능성 (Proposal of a Mathematical Model for Variations in Repeated Measurement of Korean Medicine Clinical Variables and its Applicability to Education)

  • 정하영;권영규;김창업
    • 동의생리병리학회지
    • /
    • 제36권5호
    • /
    • pp.193-208
    • /
    • 2022
  • In this study, we proposed a mathematical model that can explain the source of the observed variability of repeated measurement data collected in Korean medicine clinical practice, and conducted a pilot analysis to infer the source of these variability based on our model. Mathematical model was constructed by dividing the observed variations into three components: common time-dependent variations, signal shift, and measurement error. To show the applicability of our model in real data, we analyzed 20 repeated measurement data of Korean clinical indicators in graduate students of Pusan National University Graduate School of Korean Medicine. We showed how to infer each source of variations based on our model and also showed the limitation of inference given the acquired the dataset. On the basis of objective recognition of these source of the variability, we hope that quantitative investigations on these sources for each Korean medicine clinical indicator are made in the future, so that they can be used in the clinical and educational areas of Korean medicine.