• Title/Summary/Keyword: repeated error

Search Result 254, Processing Time 0.024 seconds

An Effect for Sequential Information Processing by the Anxiety Level and Temporary Affect Induction (불안수준 및 일시적 유발정서가 서열정보 어휘처리에 미치는 효과)

  • Kim, Choong-Myung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.224-231
    • /
    • 2019
  • The current paper was conducted to unravel the influence of affect induction as a background emotion in the process of cognitive task to judge the degree of sequence in groups with or without anxiety symptoms. Four types of affect induction and two sequential task types were used as within-subject variables, and two types of college students groups classified under the Beck Anxiety Inventory (BAI) as a between-subject variable were selected to determine reaction times involving sequential judgment among the lexical relevance information. DmDx5 was used to present a series of stimuli and elicit a response from subjects. Repeated measured ANOVA analyses revealed that reaction times and error rates were significantly larger with anxiety participants compared to the normal group regardless of affect and task types. Within-subject variable effects found that specific affect type (sorrow condition) and number-related task type showed a more rapid response compared to other affect types and magnitude-related task type, respectively. In sum, these findings confirmed the difference in tendency with reaction time and error rates that varied as a function of accompanying affect types as well as anxiety level and task types suggesting the that underlying background affect plays a major role in processing affect-cognitive association tasks.

Effects of Cervical Stabilization and Scapular Stabilization Exercise on the Proprioception and Craniovertebral Angle and Upper Trapezius Muscle Tone of People with F orward Head Posture

  • Seung-Hwan, Lee;Byoung-Ha, Yoo;Hyun-Seo, Pyo;Dongyeop, Lee;Ji-Heon, Hong;Jae-Ho, Yu;Jin-Seop, Kim;Seong-Gil, Kim
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.17 no.4
    • /
    • pp.1-13
    • /
    • 2022
  • PURPOSE: This study examined the effects of the craniovertebral angle, proprioception (joint error test), and the upper trapezius on the muscle tone when comparing cervical stabilization and scapula stabilization exercises and when two exercises were performed together. METHODS: The participants in this study agreed in advance, and this study was carried out by recruiting 27 university students in their twenties with mild frontal posture. The subjects were assigned randomly to three groups that performed cervical stabilization exercises, scapular stabilization exercises, and both cervical and scapular stabilization exercises. One-way repeated ANOVA was used to analyze the evaluation values of the 1st, 3rd, and 6th weeks of exercise intervention within the group, and one-way ANOVA was used to compare the difference in the effects of exercise intervention among the three groups. RESULTS: Proprioception was significantly different in the cervical stabilization exercises (CSE) group and the cervical stabilization exercises + Scapular stabilization exercises (CSE+SSE) groups at three weeks, and there was a significant difference between the scapular stabilization exercises (SSE) group and the CSE+SSE group (p < .05). At six weeks, there was a significant difference between the CSE group and the CSE+SSE group, and there was a significant difference between the SSE group and the CSE+SSE group (p < .05). There was a significant difference between three and six weeks in the CSE group (p < .05). In the SSE group, there was a significant difference between pre and six weeks, and between three and six weeks (p < .05). In the CSE+SSE group, there was a significant difference between pre and three weeks, and between pre and six weeks (p < .05). On the other hand, there were no significant differences between CVA and muscular tone in all three groups (P > .05). CONCLUSION: In all groups, the proprioception (joint error test) showed significant improvement, and the CSE+SSE group showed greater improvement than the other groups. As a result, the appropriate combination of neck stabilization exercise and scapular stabilization exercise effectively improved proprioception in the presence of forward head posture (FHP).

Design of SC-FDE System Using CAZAC Sequence (CAZAC Sequence를 이용한 SC-FDE 시스템 설계)

  • Kang, Hoon;Im, Se-Bin;Choi, Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.2A
    • /
    • pp.169-178
    • /
    • 2007
  • In this paper, we propose a signal structure and its optimum receiver to improve performance of SC-FDE(Single Carrier with Frequency Domain Equalization) system. Conventional SC-FDE systems have a drawback of power unbalance in frequency domain due to generation of pilot signals in time domain. The unbalanced power in frequency domain induces a channel estimation error and the performance of the receiver is degraded significantly. To overcome the drawback we apply CAZAC sequence which has constant power distribution in time and frequency domain. We design the signal structure to improve the performance with the repeated CAZAC sequence, and we design a receiver to optimize the proposed structure. Computer simulation results show that the proposed structure is superior to the conventional structure considering frame synchronization, frequency synchronization and channel equalization on typical wireless mobile channel environment.

Analysis of Korean Language Parsing System and Speed Improvement of Machine Learning using Feature Module (한국어 의존 관계 분석과 자질 집합 분할을 이용한 기계학습의 성능 개선)

  • Kim, Seong-Jin;Ock, Cheol-Young
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.8
    • /
    • pp.66-74
    • /
    • 2014
  • Recently a variety of study of Korean parsing system is carried out by many software engineers and linguists. The parsing system mainly uses the method of machine learning or symbol processing paradigm. But the parsing system using machine learning has long training time because the data of Korean sentence is very big. And the system shows the limited recognition rate because the data has self error. In this thesis we design system using feature module which can reduce training time and analyze the recognized rate each the number of training sentences and repetition times. The designed system uses the separated modules and sorted table for binary search. We use the refined 36,090 sentences which is extracted by Sejong Corpus. The training time is decreased about three hours and the comparison of recognized rate is the highest as 84.54% when 10,000 sentences is trained 50 times. When all training sentence(32,481) is trained 10 times, the recognition rate is 82.99%. As a result it is more efficient that the system is used the refined data and is repeated the training until it became the steady state.

Reliability of the Active Knee Extension Test With a Pressure Biofeedback Unit

  • Kim, Chang-ho;Gwak, Gyeong-tae;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.24 no.3
    • /
    • pp.40-46
    • /
    • 2017
  • Background: The active knee extension (AKE) test commonly used to assess the flexibility of the hamstring muscles. Many researchers have tested the reliability of the AKE test; however, no published studies have examined the intrarater and interrater reliability of the AKE test using a PBU. Objects: The purpose of this study was to determine the intrarater and interrater reliability of the AKE test performed with a pressure biofeedback unit (PBU) on healthy subjects. Methods: Sixteen healthy male participants volunteered and gave informed consent to participate in this study. Two raters conducted AKE tests independently with a PBU. Each knee was measured twice, and the AKE testing was repeated one week after the first round of testing. Results: The interrater reliability's intraclass correlation coefficients ($ICC_{2,1}$) were .887~.986 for the right knees and .915~.988 for the left knees. In addition, the intrarater (test-retest) reliability ($ICC_{3,1}$) values ranged between .820~.915 and .820~.884 for Raters 1 and 2, respectively. The values for the standard error of mesurement were low for all tests ($.81{\sim}2.97^{\circ}$); the calculated minimum detectable change was $2.24{\sim}8.21^{\circ}$. Conclusion: These findings suggest that the AKE test performed with a PBU had excellent interrater and intrarater reliability for assessing hamstring flexibility in healthy young males.

Developing an Estimation Model for Safety Rating of Road Bridges Using Rule-based Classification Method (규칙 기반 분류 기법을 활용한 도로교량 안전등급 추정 모델 개발)

  • Chung, Sehwan;Lim, Soram;Chi, Seokho
    • Journal of KIBIM
    • /
    • v.6 no.2
    • /
    • pp.29-38
    • /
    • 2016
  • Road bridges are deteriorating gradually, and it is forecasted that the number of road bridges aging over 30 years will increase by more than 3 times of the current number. To maintain road bridges in a safe condition, current safety conditions of the bridges must be estimated for repair or reinforcement. However, budget and professional manpower required to perform in-depth inspections of road bridges are limited. This study proposes an estimation model for safety rating of road bridges by analyzing the data from Facility Management System (FMS) and Yearbook of Road Bridges and Tunnel. These data include basic specifications, year of completion, traffic, safety rating, and others. The distribution of safety rating was imbalanced, indicating 91% of road bridges have safety ratings of A or B. To improve classification performance, five safety ratings were integrated into two classes of G (good, A and B) and P (poor ratings under C). This rearrangement was set because facilities with ratings under C are required to be repaired or reinforced to recover their original functionality. 70% of the original data were used as training data, while the other 30% were used for validation. Data of class P in the training data were oversampled by 3 times, and Repeated Incremental Pruning to Produce Error Reduction (RIPPER) algorithm was used to develop the estimation model. The results of estimation model showed overall accuracy of 84.8%, true positive rate of 67.3%, and 29 classification rule. Year of completion was identified as the most critical factor on affecting lower safety ratings of bridges.

Occurrence of Ovario-uterine Disease and Hormonal Therapeutic Effect in Dairy Cows (젖소에서 난소.자궁 질병 발생과 호르몬 치료 효과)

  • Ryu, Jae-Sun;Park, Chul-Ho;Kim, Sang-Il;Bae, Jae-Han;Suh, Guk-Hyun;Kim, Jae-Pung;Park, Sang-Guk;Lee, Suk-Kyung;Son, Chang-Ho;Oh, Ki-Seok
    • Journal of Embryo Transfer
    • /
    • v.26 no.1
    • /
    • pp.37-43
    • /
    • 2011
  • A total 5,946 cows from 24 dairy farms were carried out for the improvement of reproductive performance. Dairy cows in post-parturition 30 day were performed periodic reproductive examination to check for recovery of post-parturition ovary and uterus and for the early diagnosis of reproductive disease. The results obtained from this studies were as follow. The result of 1,126 cows with ovario-uterine disease were 579 slient heat and error of estrus detection (51.4%), 296 ovarian disease (26.3%), 248 uterine disease (22%), mummification and freematin were each 1 head (0.1%), respectively. Hormonal therapeutic effects were follicular cyst 81.5%, luteal cyst 90.7%, endometritis 86.9%, mucometra 90.1%, pyometra 60.9%, respectively. In cows, even if the 1st treatment fails, 2nd, 3rd treatment were performed. Therapeutic effect of 2nd, 3rd were reduced, but the number of cured cows were gradually increased. The cured cows after hormonal treatment were performed service repeatedly and the cumulative conception rate were increased. The cows treated with hormones at first service, the conception rate were follicular cyst 26%, luteal cyst 64.1%, endometritis 38.7%, mucometra 40%, pyometra 20.5%, respectively. The cumulative conception rates were increased by repeated service follicular cyst 57.3%, luteal cyst 84.6%, endometritis 67%, mucometra 75%, pyometra 64.1%, respectively.

Pericardial Tamponade following Perihepatic Gauze Packing for Blunt Hepatic Injury (둔상성 간손상 환자의 손상 통제술 후 발생한 심낭압전)

  • Ye, Jin Bong;Sul, Young Hoon;Go, Seung Je;Kwon, Oh Sang;Kim, Joong Suck;Park, ang Soon;Ku, Gwan Woo;Lee, Min Koo;Kim, Yeong Cheol
    • Journal of Trauma and Injury
    • /
    • v.28 no.3
    • /
    • pp.211-214
    • /
    • 2015
  • The primary and secondary survey was designed to identify all of a patient's injuries and prioritize their management. However 15 to 22.3% of patient with missed injuries had clinically significant missed injuries. To reduce missed injury, special attention should be focused on patients with severe anatomical injury or obtunded. Victims of blunt trauma commonly had multiple system involvement. Some reports indicate that inexperience, breakdown of estalished protocol, clinical error, and restriction of imaging studies may be responsible for presence of missed injury. The best way of reducing clinical significant of missed injuries was repeated clinical assessment. Here we report a case of severe blunt hepatic injury patient and pericardial injury that was missed in primary and secondary survey. After damage control surgery of hepatic injury, she remained hemodynamically unstable. Further investigation found cardiac tamponade during intensive care. This was managed by pericardial window operation through previous abdominal incision and abdominal wound closure was performed.

  • PDF

Implementation of Capacitance Measurement Equipment for Fault Diagnosis of Multi-channel Ultrasonic Probe (다중채널 초음파 프로브 고장진단을 위한 커패시턴스 측정 장치 구현)

  • Kang, Bub-Joo;Kim, Yang-soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.1
    • /
    • pp.175-184
    • /
    • 2016
  • In this paper, we propose the method to measure the capacitances using not LCR meter but capacitance to voltage(C/V) conversion. And we design the analog MUX circuits that convert 192 channels to 6 MUX channels in order to implement the diagnosis of multi-channel ultrasonic probe. This paper derives the conversion function that converts the digital voltage of each MUX channel to the capacitance using the least squares method because the circuit characteristics that convert the voltage of each MUX channel to the capacitance are different. The developed prototype illustrates the performance test results that the measure times are measured by within 4sec and the measure error rates of maximum, minimum, and average values are within 5% in terms of the repeated measurements of all 192 channels.

Development of Electric Actuator Position Control System for Automatic Shuttle Shifting of Tractor (트랙터의 전후진 자동 변속을 위한 전자식 액추에이터의 위치 제어 시스템 개발)

  • Choi, Chang-Hyun;Woo, Mi-Na;Lee, Dae-Hyun;Kim, Yong-Joo;Jeong, Jin-Hee
    • Journal of Biosystems Engineering
    • /
    • v.35 no.4
    • /
    • pp.224-230
    • /
    • 2010
  • The purpose of this study was to develop position control system of an electric actuator for automatic shuttle shifting of a tractor. The electric actuator was installed at the link of the forward-reverse gearshift of the tractor transmission, and controlled in the ranges of forward, neutral, and reverse positions. The position control system of the electric actuator was developed based on PID (Proportional Integral Derivative) controller and transfer function of the electric actuator. The coefficients of the PID controller were determined by Ziegler-Nichols (Z-N) method and optimized using simulation program. The prototype AMT (Automated Manual Transmission) test unit of the tractor was installed and used to evaluate the performance of the position control. The evaluation system for the control performance consisted of forward-reverse actuator, motor driver, and controller. The tests were conducted as the controlled positions of the actuator were changed from neutral position to forward, neutral, and reverse positions in sequence. The sequential tests were repeated 20 times. The operations of changing the gearshift were considered as the step response of the control system. Maximum overshoot, settling time, and steady-state error were analyzed. The results showed that performance of the position control system was reasonable and qualified. The maximum overshoots, the steady-state errors, and the settling times of the position control system were 10~20%, 1~5%, and 0.92~1.49 sec, respectively. The modifications of the electric actuator will be required to enhance the performance of position control during field operation.