• Title/Summary/Keyword: repeatable treatment

Search Result 25, Processing Time 0.026 seconds

Effect of Moisture in a Vacuum Chamber on the Deposition of c-BN Thin Film using an Unbalanced Magnetron Sputtering Method (비대칭 마그네트론 스퍼터링 방법에 의한 질화붕소막의 증착시 반응실내의 초기 수분이 입방정질화붕소 박막의 형성에 미치는 영향)

  • Lee, Eun-Sook;Park, Jong-Keuk;Lee, Wook-Seong;Seong, Tae-Yeon;Baik, Young-Joon
    • Journal of the Korean Ceramic Society
    • /
    • v.49 no.6
    • /
    • pp.620-624
    • /
    • 2012
  • The role of moisture remaining inside the deposition chamber during the formation of the cubic boron nitride (c-BN) phase in BN film was investigated. BN films were deposited by an unbalanced magnetron sputtering (UBM) method. Single-crystal (001) Si wafers were used as substrates. A hexagonal boron nitride (h-BN) target was used as a sputter target which was connected to a 13.56 MHz radiofrequency electric power source at 400 W. The substrate was biased at -60 V using a 200 kHz high-frequency power supply. The deposition pressure was 0.27 Pa with a flow of Ar 18 sccm - $N_2$ 2 sccm mixed gas. The inside of the deposition chamber was maintained at a moisture level of 65% during the initial stage. The effects of the evacuation time, duration time of heating the substrate holder at $250^{\circ}C$ as well as the plasma treatment on the inside chamber wall on the formation of c-BN were studied. The effects of heating as well as the plasma treatment very effectively eliminated the moisture adsorbed on the chamber wall. A pre-deposition condition for the stable and repeatable deposition of c-BN is suggested.

Study on super-hydrophobic electro-spray micro thruster and measurement of micro scale thrust (초소수성 전기 분무 마이크로 추진 장치 및 마이크로 추력 측정)

  • Lee, Young-Jong;Yoo, Yong-Hoon;Tran, Si Bui Quang;Kim, Sang-Hoon;Park, Bae-Ho;Buyn, Do-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.2
    • /
    • pp.175-180
    • /
    • 2009
  • In this article, we fabricated polytetrafluoroethylene(PTFE) nozzle treated by ion beam, in order to fabricate polymer based electrospray micro thruster with super hydrophobic nozzle. To obtain the super hydrophobic surface, PTFE surface is treated by argon and oxygen plasma treatment process. The optimal condition is investigated argon and oxygen flow rate as well as the paalied energy level for the treatment process. Fabricated nozzle was evaluated by measuring contact angle, and the surface morphology was examined by using scanning electron microscope(SEM) and atomic force microscope(AFM). We observe that jetting becomes more stable and repeatable on the treated nozzle. And to evaluate performance of fabricated nozzle, we measure micro scale thrust using a cantilever and a nozzle treated by ion beam laser displacement sensor.

Intra-articular replacement of a ruptured cranial cruciate ligament using the Mini-TightRope in the dog: a preliminary study

  • Pinna, Stefania;Lanzi, Francesco;Tassani, Chiara;Mian, Giacomo
    • Journal of Veterinary Science
    • /
    • v.21 no.5
    • /
    • pp.53.1-53.12
    • /
    • 2020
  • Background: The TightRope System is a device developed to provide extracapsular stabilization of the cranial cruciate ligament (CCL) rupture in canine stifles. I was then also employed for the extra-articular treatment of shoulder instability and for the intra-articular treatment of hip luxation in dogs and cats. Objectives: To evaluate the feasibility of the Mini-TightRope (mTR) System for the intraarticular treatment of CCL rupture in small breed dogs. Methods: A cadaveric canine model was used to record the steps of the surgical procedure. Five client owned dogs weighing from 8 to 10 kg and from 2 to 12 years of age were enrolled in the prospective study in which the mTR device was implanted in the stifle joint to replace the ruptured CCL. The dogs were graded using the Bologna Healing Stifle Injury Index (BHSII) and radiographic osteoarthritis (OA) scores. Results: The outcomes obtained at the time of the surgery (T0) and for the following 12 months (T12) showed an improvement in the functional parameters (BHSII from a median of 74.3 [range, 58.1-82.4] at T0 to 95.6 [range, 94.1-99.3] at T12]). The OA did not change in 3 dogs and increased by only 1 point in 2 dogs. Conclusions: In this preliminary study, the mTR was a successful and repeatable intraarticular surgical procedure for all dogs. Additional studies related to the clinical application of the technique in medium-large dogs should be encouraged.

Eosinophil-derived neurotoxin: a novel biomarker for diagnosis and monitoring of asthma

  • Kim, Chang-Keun
    • Clinical and Experimental Pediatrics
    • /
    • v.56 no.1
    • /
    • pp.8-12
    • /
    • 2013
  • Asthma is associated with increased levels of eosinophils in tissues, body fluids, and bone marrow. Elevated levels of eosinophil-derived neurotoxin (EDN) and eosinophil cationic protein (ECP) have been noted in asthma patients. Higher levels of EDN and ECP are also associated with exacerbated asthmatic conditions. Thus, EDN, along with ECP, may aid the diagnosis and monitoring of asthma. Several groups have suggested that EDN is more useful than ECP in evaluating disease severity. This may partially be because of the recoverability of EDN (not sticky, 100% recovery rate), as ECP is a sticky and more highly charged protein. In terms of clinical utility, EDN level is a more accurate biomarker than ECP when analyzing the underlying pathophysiology of asthma. As a monitoring tool, EDN has shown good results in children with asthma as well as other allergic diseases. In children too young to fully participate in lung function tests, EDN levels may be useful as an alter native measurement of eosinophilic inflammation. EDN can also be used in adult patients and in multiple specimen types (e.g., serum, sputum, bronchoalveolar lavage fluid, and nasal lavage fluid). These results are repeatable and reproducible. In conclusion, EDN may be a novel biomarker for the diagnosis, treatment, and monitoring of asthma/allergic disease.

A Study on the Investigation of Optimal Peening Intensity for Shot Peened Spur Gear (쇼트피닝가공한 평기어의 최적 피닝강도 탐색에 관한 연구)

  • Cheong Seong-Kyun;Lee Dong-Sun;Lee Kook-Jin;Kim Tae-Hyung
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.185-190
    • /
    • 2005
  • The shot peening process is often used to improve fatigue properties of metal parts. Among them, It is the most use in an auto-component. In order to achieve optimum, repeatable and reliable fatigue enhancement from the shot peening process, the important shot peening parameters must be controlled. In this paper, the optimum peening intensity (Almen intensity) condition is investigated by experiment. The Spur Gear steel was used to investigate shot peening effects. The fatigue life at $\sigma_a=1,050$ and $\sigma_a=1,250MPa$ first gently increases, then drops gently as peening intensity increases compared with unpeened specimen. Experimental results show that the optimum peening intensity range is $0.391\~0.434mmA$..So the fatigue strength and fatigue life have been tremendously increased by optimum-peening treatment. However, the fatigue strength and fatigue life have been decreased by over peeing.

  • PDF

A Study on the Optimum Shot Peening Condition for Al7075-T6 (AL7075-T6의 최적 쇼트피닝 조건에 관한 연구)

  • Jeong,Seong-Gyun;Kim,Tae-Hyeong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.7
    • /
    • pp.63-68
    • /
    • 2003
  • Shot peening process is most often used to improve the fatigue properties of metal parts, In order to achieve an optimum, repeatable, and reliable fatigue enhancement from the shot peening process, the important shot peening parameters must be optimized, In this paper, the optimum peening intensity(Almen intensity) condition is investigated by experiment. Rotary bending fatigue test has been adopted to investigate the effects of optimum peening on the fatigue characteristics, Experimental results show that the fatigue strength and fatigue life has been tremendously increased by optimum-peening treatment. However, the fatigue strength and fatigue life has been decreased by under or over peening.

Radiofrequency Facet Joint Denervation in the Treatment of Low Back Pain: Relationship with the Diagnostic Block (요부 후지낵측지 고주파 열응고술: 진단적 차단과의 연관성)

  • Shim, Jae-Chol;Seung, Ik-Sang
    • The Korean Journal of Pain
    • /
    • v.14 no.2
    • /
    • pp.218-224
    • /
    • 2001
  • Background: Response to diagnostic blocks does not consistently predict the outcome of interventional facet denervation. We investigated the relationship between pain relief by the percutaneous radiofrequency denervation of the lumbar zygapophysial joints with the result of facet joint diagnostic local anesthetic injection in patients with back pain originating from the lumbar zygapophysial joint. Methods: There were 35 patients enrolled, with ranging in age from 25 to 76 years ($52.6{\pm}12.7$ years, mean ${\pm}$ SD). We studied 7 men (20%) and 28 women (80%). All patients underwent double diagnostic block of $L_{3/4}$, $L_{4/5}$ and $L_5-S_1$ facet joint with 0.5% bupivacaine. The 35 patients fell into the following group. (1) Group A (n = 16): those who felt clear relief (pain free with Likert scale) from the double diagnostic block (2) Group B (n = 19): 11 patients who were always equivocal in their response to the double diagnostic block and 8 patients who were either pain free or equivocal in their response to the double diagnostic block. All 11 patients were done the facet joint denervation. The effect on the pain was evaluated with 4 point Likert scale 1, 6 and 12 weeks after the procedure. We evaluated the relationship between the pain response to diagnostic block and the pain relief with facet joint denervation. Results: Significant correlation was observed between the response to diagnostic block and pain relief with facet denervation (P < 0.05). We found no correlation between the categories of spinal operation and pain response to facet denervation (P value > 0.05). Conclusions: A satisfactory result of lumbar facet joint denervation can be obtained in many patients, especillay in patients whose pain were relieved by the diagnostic double facet joint block. It may be said that facet joint denervation for mechanical low back pain using radiofrequency thermocoagulation is a safe, easy, and repeatable technique.

  • PDF

A Study on the Characteristics of Simulated Real Driving Emissions by Using Random Driving Cycle (임의주행 사이클을 이용한 실제도로 주행 배출가스 특성 모사에 관한 연구)

  • Kwon, Seokjoo;Kwon, Sangil;Kim, Hyung-Jun;Seo, Youngho;Park, Sungwook;Chon, Mun Soo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.4
    • /
    • pp.454-462
    • /
    • 2016
  • This study was conducted in order to estimate the exhaust emissions analysis method of the real driving emission(RDE). The Association for Emissions Control by Catalyst(AECC) has developed a test procedure by using a random cycle method based on the chassis dynamometer. In order to confirm this approach in Korea, Euro 5(DPF), Euro 6(DPF + LNT), and Euro 6(DPF + SCR) were performed on three different vehicles to determine the exhaust gas characteristics of the random cycle, real-road driving test(PEMS), and emission certification driving mode(NEDC). Six different random cycle driving modes were generated by the vehicle specifications(e.g. curb weight, engine power, gear ratio, and maximum acceleration). The NOx emissions were increased in the NEDC, random cycle, and PEMS order in this study regardless of the test vehicles. The random cycle method has the advantage because it utilizes a chassis dynamometer in the laboratories for a repeatable data collection, and it allows any eminent emission improvement checked prior to a real-road driving test with PEMS.

Improvement in the bias stability of zinc oxide thin-film transistors using an $O_2$ plasma-treated silicon nitride insulator

  • Kim, Ung-Seon;Mun, Yeon-Geon;Gwon, Tae-Seok;Park, Jong-Wan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.180-180
    • /
    • 2010
  • Thin film transistors (TFTs) based on oxide semiconductors have emerged as a promising technology, particularly for active-matrix TFT-based backplanes. Currently, an amorphous oxide semiconductor, such as InGaZnO, has been adopted as the channel layer due to its higher electron mobility. However, accurate and repeatable control of this complex material in mass production is not easy. Therefore, simpler polycrystalline materials, such as ZnO and $SnO_2$, remain possible candidates as the channel layer. Inparticular, ZnO-based TFTs have attracted considerable attention, because of their superior properties that include wide bandgap (3.37eV), transparency, and high field effect mobility when compared with conventional amorphous silicon and polycrystalline silicon TFTs. There are some technical challenges to overcome to achieve manufacturability of ZnO-based TFTs. One of the problems, the stability of ZnO-based TFTs, is as yet unsolved since ZnO-based TFTs usually contain defects in the ZnO channel layer and deep level defects in the channel/dielectric interface that cause problems in device operation. The quality of the interface between the channel and dielectric plays a crucial role in transistor performance, and several insulators have been reported that reduce the number of defects in the channel and the interfacial charge trap defects. Additionally, ZnO TFTs using a high quality interface fabricated by a two step atomic layer deposition (ALD) process showed improvement in device performance In this study, we report the fabrication of high performance ZnO TFTs with a $Si_3N_4$ gate insulator treated using plasma. The interface treatment using electron cyclotron resonance (ECR) $O_2$ plasma improves the interface quality by lowering the interface trap density. This process can be easily adapted for industrial applications because the device structure and fabrication process in this paper are compatible with those of a-Si TFTs.

  • PDF

Short-term clinical outcome of intentionally replanted posterior molars (의도적 재식술을 시행한 대구치의 단기간의 임상 평가)

  • Choi, Yong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.1
    • /
    • pp.12-18
    • /
    • 2011
  • Objectives: This retrospective study evaluated the therapeutic effects of the intentional replantation (IR) procedure performed on the maxillary and mandibular molars of 35 patients. Materials and Methods: For the subjects, IR was performed due to difficulties in anatomically accessing the lesions and/or close proximity to the thick cortical bone, inferior alveolar nerve, or maxillary sinus, which rendered the ordinary periradicular surgery impossible. The patients'progress was followed for a year and up to 2 years and 4 months. The success of the procedure was evaluated in terms of clinical and radiographic success (%). Results: The results revealed the following: (a) 1 case (3%) of failed tooth extraction during IR; (b) 2 cases (6%) of extraction due to periodontal diseases and inflammatory root resorption; (c) 3 cases (9%) of normally functioning teeth in the oral cavity with minor mobility and apical root resorption, and; (d) 29 cases (82%) of normally functioning teeth without obvious problems. Conclusions: IR was confirmed to be a reliably repeatable, predictable treatment option for those who cannot receive conventional periradicular surgery because of anatomic limitations or patient factors.