고정밀 공작기계 이송장치의 정밀도 측정방법 및 불확도 요인에 관한 연구 (A Study on the Measurement Method and Uncertainty Factors for Precision Inspection to Feed Unit of High Precision Machine Tool)

  • 김상화;김병하;최우각
    • 한국기계가공학회지
    • /
    • 제11권4호
    • /
    • pp.55-61
    • /
    • 2012
  • Very important content in performance evaluation of machine tool is positioning accuracy and repeatability precision measurements of feed mechanism. A study analyses the measurement method and uncertainty factors by ISO-based test method. Reliable results can't be derived without the notion of measurement uncertainty. The reason is that the measured value includes a lot of uncertain factors. Finding the factor that affects the measurement of parameter is important for estimation of measurement precision. In this paper, the evaluation of uncertainty analysis about positioning accuracy and repeatability precision measurements of high precision feed mechanism is presented to evaluate the important factors of uncertainty.

직물 드레이프 재현성에 관한 연구 (A Study on the Repeatability of Fabric Drape)

  • 정영진;민병길;이준석
    • 한국의류산업학회지
    • /
    • 제1권1호
    • /
    • pp.50-55
    • /
    • 1999
  • The repeatability of fabric drape was studied. Two methods for draping were used and the relation between node distributions was investigated using statistical analysis. With this, the relationship between node distribution and fabric mechanical properties was studied. The repeated measurements showed that there was no evidence that fabric has intrinsic node number and the mechanical properties influence on the number of nodes.

  • PDF

단안 구면 끝점검사의 반복성 검증 (Repeatability of Monocular Spherical Endpoints Test)

  • 김상엽;문병연;조현국
    • 한국안광학회지
    • /
    • 제17권2호
    • /
    • pp.209-213
    • /
    • 2012
  • 목적: 검영법, MPMVA법(maximum plus maximum visual acuity), 적녹이색법, 크로스실린더법의 단안 구면 끝점검사 반복성을 분석하고자 하였다. 방법: 평균연령 23.0세의 남녀 20명(40안)을 대상으로 4가지 검사법(검영법, MPMVA법, 적녹이색법, 크로스실린더법)으로 끝점 구면굴절력을 측정하였다. 일주일 간격으로 재검사를 실시하고 Bland-Altman plot 분석을 이용하여 검사-재검사 간 반복성을 분석하였다. 결과: 각 검사법의 검사-재검사 평균은 검영법이 가장 적은 -0.03 D이었고, 적녹이색법이 가장 큰 -0.19 D이었다. 검사-재검사의 95% 일치도 상/하한선은 검영법이 가장 좁았고 크로스실린더법이 가장 넓었다. 각 검사안의 검영법 끝점값과 다른 세 검사법의 끝점값을 비교하였을 때 전체 검사안의 ${\pm}0.25$ D 이내 오차 비율은 MPMVA법 85%, 적녹이색검사 80%, 크로스실린더법 24%로 나타났다. 결론: 검영법의 반복성이 가장 높았으며, 검영법, MPMVA법, 적녹이색법은 단안 구면 끝점검사를 위한 적합한 검사법으로 나타났다.

색 시표와 색 필터를 이용한 새로운 사위검사의 신뢰도 (Repeatability of New Phoria Test Using Color Chart and Color Filter)

  • 이선행;박선영;김상엽;이동열;김건규;손정식;이재윤;조현국
    • 한국안광학회지
    • /
    • 제15권3호
    • /
    • pp.269-274
    • /
    • 2010
  • 목적: 새로운 적청사위시표(Red-Blue phoria chart; RBP) 검사의 신뢰성을 평가하였다. 방법: 38명을 대상으로 원거리(5m), 근거리(40cm) 사위량을 측정하였다. RBP 시표 사위검사, 하웰시표 사위검사(HP), 그리고 Muscle Imbalance Measure (MIM) 시표 사위검사를 실시하고 검사에 대한 신뢰도를 서로 비교하였다. 결과: 수평 사위도는 원거리 RBP $-0.6{\pm}0.727{\Delta}$, HP $-0.87{\pm}1.051{\Delta}$, MIM $-1.50{\pm}1.346{\Delta}$, 근거리 RBP $-2.57{\pm}2.352{\Delta}$, HP $-2.80{\pm}2.411{\Delta}$, MIM $-3.84{\pm}2.603{\Delta}$로 측정되었다. 검사 신뢰도는 원거리의 경우 RBP>MIM>HP 순이었고, 근거리의 경우 MIM>RBP>HP 순으로 나타났다. 결론: RBP 검사법은 신뢰도가 높은 사위검사법으로 판명되었다.

6시그마 품질을 위한 Gage R&R의 영향에 관한 연구 (A Study on the Effect of Gage R&R for 6 Sigma Quality)

  • 이승훈;이정환
    • 산업경영시스템학회지
    • /
    • 제23권55호
    • /
    • pp.13-24
    • /
    • 2000
  • 6 sigma movement is the most prominent quality improvement methodology in practice. Measurement plays an important role in helping any organization improve quality. Therefore, the measurement systems analysis is the first step for the quality improvement of manufacturing process in 6 sigma movement. In this study, we investigate the effect of Gage Repeatability and Reproducibility(Gage R&R) in view of defect rate and process capability indices, and provide guidelines for acceptance of gage repeatability and reproducibility(%R&R) for six sigma quality.

  • PDF

치과용 백색광 스캐너를 이용한 impression scanning의 반복 측정에 대한 안정성 평가 (Evaluation on the repeatability of dental white light scanner-based digital impression)

  • 전진훈;이경탁;김혜영;김지환;김웅철
    • 대한치과기공학회지
    • /
    • 제35권1호
    • /
    • pp.37-42
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the repeatability of dental white light scanner. Methods: The impression(Zerosil, Dreve, Germany) were digitized in white light scanner(Identica, Medit, Korea) to create 3-dimensional surface-models. The distribution of the discrepancies between the number of points in the corresponding CRM models and the point clouds in the others were measured by a matching-software(PowerInspect 2012, Delcam Plc, UK). The discriptive statistics were used for statistical analysis(SPSS 20.0). Results: The measurement of repeatablity showed very good reliability. The mean(SD) discrepancy value on the white light scanner digital models was 8.7(0.67) ${\mu}m$, based on SD and absolute mean values. Conclusion: These in vitro studies showed that repeatability of dental white light scanner is high reliability. These results can be confirmed in further clinical studies.

Capacitively Coupled Plasma Source를 이용한 Etcher의 상부 전극 온도 변화에 따른 Etch 특성 변화 개선 (Improvement of Repeatability during Dielectric Etching by Controlling Upper Electrode Temperature)

  • 신한수;노용한;이내응
    • 한국진공학회지
    • /
    • 제20권5호
    • /
    • pp.322-326
    • /
    • 2011
  • 상부 전극에 RF power 가 직접 인가되는 capacitively coupled plasma source를 이용한 oxide layer etching 공정은 현재 반도체 제조 공정에서 매우 유용하게 사용되고 있는 방식이다. 그러나 디바이스의 사이즈가 점점 작아지면서 공정을 진행하기 위한 RF power도 커지고, plasma ignition 되는 electrode 사이의 간격도 점점 좁아지는 기술적 변화가 이루어지고 있다. 이러한 H/W의 변화에 따라 예상치 못한 문제들로 공정을 적용하는데 많은 문제점이 발생하고 있는데, 공정 진행 시에 plasma의 영향으로 인한 electrode의 온도 변화도 그 중 하나이다. 이러한 온도 변화로 인해 wafer to wafer의 공정 진행 결과가 서로 다르게 나타나게 하는 문제가 야기되고 있다. 아래의 내용에서는 상부 electrode의 온도 변화에 따른 etch 특성을 연구하고, 이를 개선할 수 있는 방법에 대해 논하고자 한다.

나로호에 탑재된 GPS 수신기의 항법해와 신호대잡음비의 일반복 특성 (Day-to-Day Repeatability of the Navigation Solution and SNR from the GPS Receiver installed on KSLV-I)

  • 권병문;문지현;신용설;최형돈;조광래
    • 한국항공우주학회지
    • /
    • 제39권8호
    • /
    • pp.774-787
    • /
    • 2011
  • 본 논문은 다중경로신호를 포함한 위성항법신호의 특성에 관한 정량적 분석을 수행하고, 나로우주센터의 발사대에 나로호가 발사대기중일 때에 저장된 데이터를 바탕으로 발사장 주변환경으로부터 발생한 다중경로신호로 인하여 GPS 수신기에서 계산된 항법해 및 신호대잡음비에서 나타난 일반복 특성에 대하여 다룬다. 발사대에 설치된 나로호에서는 GPS 안테나와 주위환경 및 GPS 위성궤도가 거의 변하지 않으므로 계산된 항법해와 신호대잡음비의 변화율과 크기가 그대로 일반복 되고 있음을 확인하였다. 다중경로의 영향에 관한 분석과 발사대에서 관찰된 항법해와 신호대잡음비의 일반복 특성은 위성발사체가 발사대기하고 있을 때에 GPS 수신기의 성능을 안정화시키기 위한 방법을 찾는데 크게 도움이 될 것이다.

통합 체질진단 시스템 개발 및 반복성 평가 (Development and Evaluation of Repeatability of the Integrated Constitutional Diagnosis System)

  • 전영주;김장웅;김재욱;배장한;김종열;김근호
    • 사상체질의학회지
    • /
    • 제24권3호
    • /
    • pp.34-41
    • /
    • 2012
  • Objectives In this study, we developed a mock-up of the system for Sasang Constitutional (SC) diagnosis. This system consists of 5 devices which are the face analyzer, the voice analyzer, the skin analyzer, the pulse analyzer, and the computer-based questionnaire. Our goal is to evaluate the repeatability of the system. Methods Each device is capable of classifying SC types. The classification probability of the integrated system for the SC types was obtained by summing the probability from each device. For evaluating the repeatability of the system, we collected data for 5 subjects, and repeated the measurement three times for each individual. The average and standard deviation were used for calculating the Coefficient of Variation. Results The results showed that the repeatability of the classification probability of the integrated system is about 8%, which implies the system is repeatable. Conclusions To increase usability of this system, it is desirable for the system to offer information on health condition of the user. The integrated constitutional diagnosis system will be upgraded to complement the convenience and to develop the diagnostic algorithm for the user's health condition.