• 제목/요약/키워드: repair part size

검색결과 33건 처리시간 0.023초

수지동맥천공지피판술과 볼점막 이식을 통한 조갑상 손상 치험 1례 (A Case Report of Nail Bed Reconstruction with Digital Artery Perforator (DAP) Flap and Buccal Mucosal Graft)

  • 이용우;김연환;김정태
    • Archives of Plastic Surgery
    • /
    • 제38권1호
    • /
    • pp.113-116
    • /
    • 2011
  • Purpose: Many fingertip injuries are associated with nail injury and it is hard to repair to original shape due to its unique characteristic. Mucosal graft is used for a defect of the nail bed injury. Hereby, we introduce a DAP flap and buccal mucosal graft, with which we could reduce the defect size of the injured fingertip and donor site morbidity at the same time, without any need for harvesting additional skin from other part of hand. Also, mucosal graft makes good cosmetic and functional outcome of nail. Methods: This method was performed in a 56-year-old man with fingertip injury on dorsal side of left thumb due to electrical saw. First, DAP flap was performed on the injured finger to reduce the size of the defect of fingertip and cover the bone exposure. Second, nail bed part of the DAP flap was de-epithelized and buccal mucosal graft was done from left side of intraoral cavity wall. Results: Flap and graft survived without any necrosis but some nail bed could not be covered with flap due to insufficient flap size. All wounds healed well and did not present any severe adversary symptoms. Conclusion: DAP flap with mucosal graft is an effective method that we can easily apply in reconstruction of fingertip injury. We suggest that the combination of the two procedures makes good functional and cosmetic outcome compared to the usual manner, especially in cases of nail bed injury without distal phalanx bone defect.

모자업체의 유형별 치수체계에 관한 연구 (Study on the Sizing System of Head Gears)

  • 이진희;도월희
    • 한국생활과학회지
    • /
    • 제12권4호
    • /
    • pp.571-578
    • /
    • 2003
  • The purpose of this research was to provide basic information for enhancing sizing suitability in terms of the need for appropriate fit in head gear. The method for this research was to survey about sizing system of head gear, basic measure part, repair service. The subject of this study were 15 head gear companies. The results of this research were as follows : 1. In the sex target analysis according to company type, most of fashion brand companies were producing woman's head gear. In case of the company to produce man's head gear, sizes appeared variously. On the other hand, the sports brand companies were producing unisex head gear and safety helmet companies were producing man's one. 2. The number of size of head gear manufacturing companies were under 3 sizing system. This means that the sizing system of current head gear manufacturing company isn't various. 3. While the measuring part using currently in the company was head girth, one to be considered necessary for manufacturing of head gear except the head girth was head height.

  • PDF

집속이온빔의 전류변화에 따른 미세가공 특성분석 (FIB Machining Characteristic Analysis according to $Ga^+$ Ion Beam Current)

  • 강은구;최병열;홍원표;이석우;최헌종
    • 한국공작기계학회논문집
    • /
    • 제15권6호
    • /
    • pp.58-63
    • /
    • 2006
  • FIB equipment can perform sputtering and chemical vapor deposition simultaneously. It is very advantageously used to fabricate a micro structure part having 3D shape because the minimum beam size of ${\Phi}10nm$ and smaller is available. Since general FIB uses very short wavelength and extremely high energy, it can directly make a micro structure less than $1{\mu}m$. As a result, FIB has been probability in manufacturing high performance micro devices and high precision micro structures. Until now, FIB has been commonly used as a very powerful tool in the semiconductor industry. It is mainly used for mask repair, device correction, failure analysis, IC error correction, etc. In this paper FIB-Sputtering and FIB-CVD characteristic analysis were carried out according to $Ga^+$ ion beam current that is very important parameter for minimizing the pattern size and maximizing the yield. Also, for FIB-Sputtering burr caused by redeposition of the substrate characteristic analysis was carried out.

진핵세포에서 DNA 회복에 관련된 HRD3 유전자의 분리, 발현 및 특성 연구 (Study on Expression and Characterization of HRD3 Gene Related DNA Repair from Eukaryotic Cells)

  • Shin, Su-Hwa;Park, In-Soon
    • 생명과학회지
    • /
    • 제14권2호
    • /
    • pp.325-330
    • /
    • 2004
  • 효모에 있어 자외선에 의한 절제회복 관여 DNA회복유전자가 많이 알려져 있으나, 이들이 어떤 기능을 하는지는 아직 잘 알려져 있지 않다. 본 연구에서는 자외선 조사 시 절제회복의 초기 단계에 절대적으로 필요한 RAD3 유전자와 유사한 유전자인 HRD3 유전자를 분열형 효모인 Schizosaccharomyces pombe에서 분리하여 그 특성을 연구하였다. 이 결과 분리한 유전자는 효모 RAD3 유전자와 염기서열에서 약 70%이상의 유사성을 보였다. 이 유전자의 염기서열 결과 유전자 산물의 분자량은 75 kDa였다. 2-D gel 결과 과잉발현 시 HRD3 단백질은 숙주 단백질의 합성 억제 또는 분해 촉진을 유발하여 숙주세포인 대장균에 독성초과를 나타내었다. HRD3 유전자와 lacZ 유전자를 융합시킨 여러 가지 재조합 vector를 만들어 이들 융합단백질을 분리, 연구 한 결과 HRD3 단백질의 카르복실 말단부분이 효모에 있어서 DNA회복기능과 대장균에서의 독성효과를 나타내는 중요부위임이 확인되었다.

20~30대 여성의 재킷 착용실태 및 맞음새 만족도 연구 - 환편니트 재킷과 우븐 재킷을 중심으로- (A Study of Wearing Condition and Fit Preference Satisfaction for Females 20s-30s of Jackets - Focusing on circular knitted jackets and woven jackets -)

  • 황송이;최혜선;이진희
    • 한국의류산업학회지
    • /
    • 제15권4호
    • /
    • pp.596-605
    • /
    • 2013
  • This study investigates the wearing trend and purchase facts for adult females in their 20s and 30s along with their fitting satisfaction for woven jackets and circular knitted jackets. A questionnaire survey on consumers investigated satisfaction with jackets according to clothing materials and repair trend after wearing. Subsequently, a preference for circular knitted jackets was shown higher than woven jackets. Females in their 20s preferred woven jackets than those in their 30s; however, the latter preferred circular knitted jackets than the former. For woven jackets, they showed the highest satisfaction with size; however, for circular knitted jackets, they showed the highest satisfaction with fitting. In the question on their satisfaction by jacket part, satisfaction with circular knitted jackets was higher in all items except for bust measurement, bottom edge measurement, elbow circumference, shoulder width, and clothes length. Circular knitted jackets had lower repair rates than woven jackets and woven jackets had significant differences by age in satisfaction with back width. The research results indicate that females in their 20s and 30s who value fit preference and practicality will increasingly wear knit clothes. Therefore, we can address the fitting satisfaction requirement of females in their 20s and 30s by taking the clothing material properties of circular knitted clothes into consideration. In addition, further research is required on jacket patterns in consideration of clothing materials.

60~79세 노년 여성의 슬랙스 구입 현황 및 착용 만족도에 관한 연구 (Slacks Purchase Realities and Wearing Satisfaction Focused on Old-Aged Women)

  • 이정진;서미아
    • 복식문화연구
    • /
    • 제18권3호
    • /
    • pp.541-549
    • /
    • 2010
  • The purposes of this study were to examine the slacks purchases and wearing satisfaction among old-aged women who were highly dissatisfied with their bodies and fit due to physical changes and to provide some basic data needed to develop slacks patterns to meet their needs. A survey was taken among 223 old-aged women aged 60~79 living in Seoul. Using the SPSS 12.0 program, the collected data were analyzed in descriptive statistics, t-test, and crosstab. The result were as follows: the most used place for them to shop slacks was a market(including the Dongdaemun and Namdaemun market), which was followed by a department store and a discount store in the order. As for their preference for slacks according to age, those who were in their sixties most preferred straight-line slacks, while those who were in their seventies semistraight-type slacks. As for fit for each body part according to age, there were significant differences only in crotch length. Those who were in their seventies were more dissatisfied with crotch length than those who were in their sixties, feeling that crotch length was short. As for their experiences of repair after purchasing a pair of slacks, 82.5% said they had such an experience. Most of the repairs with length, waist and slacks width involved in size reduction.

복부손상으로 생긴 탈장에 Prolene Mesh를 이용한 수술 1례 (Traumatic Abdominal Wall Hernia (TAWH): Repair by using a Prolen Mesh)

  • 박승연;정민
    • Journal of Trauma and Injury
    • /
    • 제22권1호
    • /
    • pp.119-122
    • /
    • 2009
  • Traumatic abdominal wall hernia after blunt abdominal trauma is rare. The prevalence of traumatic abdominal wall hernia in published series is approximately 1%. Recently, by the use of computed tomography has increased the number of occult traumatic abdominal wall hernias (TAWH). A 47-year-old woman presented to the emergency room soon after a traffic accident. She was fully conscious and complained of diffuse, dull, abdominal pain. She had a seat belt on at the time of the accident. Initial computed tomography showed that the lower left abdominal wall had a defect and that a part of the small bowel had herniated through the defect. During the operation, we made an incision at the defect site and confirmed the defect. The defect size was about $15{\times}5cm$. The muscle layers were repaired in layers with absorbable sutures. Prolen mesh was layed down and fixed on the site of the repaired muscle defect. After 6 months, hernia had not recurred, and no weakness of the repaired abdominal wall layers was identified. The patient's postoperative body functions were normal.

Ni 나노입자의 전기영동 코팅에 의한 전열관 자가보수 기술 개발 (Self-repairing Technology by Electrophoresis of Ni Nano-Particles for Heat Exchanger Tubes)

  • 이경자;이민구;이창규
    • 한국분말재료학회지
    • /
    • 제14권4호
    • /
    • pp.238-244
    • /
    • 2007
  • The electrophoretic deposition process of Ni nano-particles in organic suspension was employed for self-repairing of heat exchanger tubes. For this purpose, Ni nano-particles prepared by levitational gas condensation method were dispersed into the solution of ethanol with the addition of dispersant Hypermer KD2. For electrophoretic deposition of Ni nano-particles on the Ni alloy specimen, constant electric fields of 20 and 100 V $cm^{-1}$ were applied to the specimen in Ni-dispersed solution. It was found that as electrophoretic deposition proceeds, the size of the pit or crack remarkably decreased due to the agglomeration of Ni nano-particles at the pit or crack. This strongly suggests that the electrophoretic mobility of the charged particles is larger for the damaged part with a higher current value rather than outer surfaces with a lower current value.

IIHS 풀 오버랩 범퍼 시험 대응 범퍼 백빔 중앙 보강재 설계 (Design of Bumper Backbeam Center Reinforcement Bracket for IIHS Full Overlap Bumper Test)

  • 강성종
    • 한국자동차공학회논문집
    • /
    • 제23권1호
    • /
    • pp.105-111
    • /
    • 2015
  • Since 2007, Insurance Institute of Highway Safety(IIHS) has conducted the new bumper test using bumper barrier to estimate the repair cost of impacted vehicle. In this study, for the front body FE model of a medium size passenger car analyzes were carried out to optimize the shape of backbeam center reinforcement bracket. First, overlap effect was examined with changing the overlap magnitude and spot welds were added along the backbeam center line for reducing the section shear deformation. Next, for an overlap model design parameter study was performed for the bracket. Thickness effect was examined and an inner reinforcement was added to the bracket. Also, the lower part of bracket was deleted and additionally the bracket length was extended. The results were discussed in terms of backbeam backward deflection, barrier backstop intrusion and weight. Compared with the current design, the final model showed 44.1% bracket weight reduction with 30.0% decrease of backbeam deflection.

Incarcerated Hiatal Hernia with Perforation after Laparoscopic Total Gastrectomy with Roux-en-Y Reconstruction: a Case Report

  • Wang, Nai-Yu;Tsai, Chung-Yu;Liu, Yuan-Yuarn;Chen, I-Shu;Ho, Kai-Hung
    • Journal of Gastric Cancer
    • /
    • 제19권1호
    • /
    • pp.132-137
    • /
    • 2019
  • The occurrence of hiatal hernia after total gastrectomy with Roux-en-Y reconstruction is rare. We report the case of a 76-year-old man who presented with dyspnea, vomiting, and fever around 8 days after total gastrectomy with Roux-en-Y reconstruction. Abdominal computed tomography revealed a hiatal hernia containing part of the small intestine in the left thoracic cavity. Emergent reduction and repair of the hiatal hernia were performed later. Operative findings revealed that the Roux limb was incarcerated in the left pleural cavity. Esophagojejunostomy leakage, perforation of the small intestine with transient ischemic change, and pyothorax were also found. Thus, feeding jejunostomy, thoracoscopic decortication, and diversion T-tube esophagostomy were performed. Considering that the main cause of hiatal hernia is blunt dissection with division of the phrenoesophageal membrane, approximating the crus with 1 or 2 figure-8 sutures, according to the size of the defect, to prevent the incidence of hiatal hernia after total gastrectomy may be performed.