• 제목/요약/키워드: removal system

검색결과 3,542건 처리시간 0.026초

인공습지에 의한 농촌오수처리에 관한 연구 (Study on Natural Wastewater Treatment Systems by Constructed Wetland for Rural Area)

  • 윤춘경;권순국;김형중
    • 한국농공학회지
    • /
    • 제39권4호
    • /
    • pp.55-63
    • /
    • 1997
  • Constructed wetland system which can be applied to the rural wastewater treatment system was examined by pilot plant in Kon-Kuk University. Hydraulic loading rate of wastewater was about 0.16m$^3$/m$^2$. day and theoretical detention time in the system was 1.38 days. The effluent of the septic tank for the school building was applied as inflow to the system. The influent concentration of DO was zero but effluent was up to 4.37mg/${\ell}$ which implies that oxygen was supplied enough from atmosphere by reaeration to support biological activity of the system. Average influent concentration of BOD was 104mg/${\ell}$ and effluent was 24mg/${\ell}$ with average removal rate of 76%. Average influent concentration of COD was 215mg/${\ell}$ and effluent was 63mg/${\ell}$ with average removal rate of 70 % . Average influent concentration of SS was 78mg/${\ell}$ and effluent was 10mg/${\ell}$ with average removal rate of 87%. Two components, BOD and SS, are regulated by law to keep maximum water quality standard of 80mg/${\ell}$ when daily outflow rate is less than 100$m^3$/day which is the case of most rural communities. Therefore, the results from the experiment showed that constructed wetland system can meet the water quality standard easily. Average influent concentration of total nitrogen was 165mg/lwhich is relatively higher than normal wastewater, and effluent was about 156mg/${\ell}$ with average removal rate of only 6%. Average influent concentration of total phosphorus was 41 mg/${\ell}$ and effluent was 6mg/${\ell}$ with average removal rate of 87%. Overall, constructed wetland system was thought to be effective to treat wastewater if nitrogen removal mechanism is improved. Considering low cost, less maintenance, and high treatability, this system can be a practical alternative for the wastewater treatment in rural area The experiment was performed during the summer and fall season, and treatment efficiency of the system is expected to decrease in low temperature. therefore, further study including temperature is required to evaluate feasibility of the system more in detail.

  • PDF

식물을 이용한 오수의 고도처리에 관한 연구 (A Study on the Advanced Treatment of Wastewater by Plants)

  • 이용두;김현희
    • 한국환경과학회지
    • /
    • 제8권1호
    • /
    • pp.75-81
    • /
    • 1999
  • In recent years increasing production and disposal of wastewater have caused an accelerated eutrophication of receiving waters. Therefore, in order to alleviate the detrimental impact of wastewater discharge, there is an increasing demand for removing the main nutrients, nitrogen and phosphorus, as well as the organic content of the waste water prior to disposal. This is effectively achieved by extended conventional treatment technology. However, the working expenses and energy requirements of such advanced treatment systems are rather high. So in a sparsely populated rural community is required development of wastewater treatment system combined with the regional characteristics. In this study, the systems are planted with Reeds and Amaryllis In A.C and estimated purification potential of system. The results obtained are as follows. BOD removal rate is 20% in the early stage, the last removal rate is 35% in A.C process and is 65% in Amaryllis+A.C process and is 50% in Reed+A.C process. T-N removal rate by Amaryllis is average 2.6g/$m^3$ㆍd, T-N removal rate by Reed is average 1.76g/$m^3$ㆍd. T-P removal rate by Amaryllis is average 0.27g/$m^3$ㆍd, T-P removal rate by Reed is average 0.25g/$m^3$ㆍd. BOD removal rate constant with retention time is 1.4494(1/d), T-N removal rate constant is 0.5428(1/d), T-P removal rate constant is 0.5287(1/d).

  • PDF

생물막 담체를 이용한 실험실 규모 $A_{2}O$공법의 시스템 변형에 따른 고도처리 성능 평가에 관한 연구 (The Study on Evaluating Performances of Lab Sacle-Advanced $A_{2}O$ with Changing System Using Biofilm Process)

  • 김민식;강구영
    • 상하수도학회지
    • /
    • 제26권2호
    • /
    • pp.209-218
    • /
    • 2012
  • Recently, as reinforced water quality standards for wastewater has been announced, more efficient and more powerful wastewater treatment processes are required rather than the existing activated sludge process. In order to meet this demands, we evaluate Task 1-4 about lab scale $A_{2}O$ process using biofilm media. Task 1, 2, and 3 use 'Module A' which has 4 partitions (Anoxic/Anerobic/Oxic/Oxic). Task 4 uses 'Module B' which has 2 partitions including a denitrification reactor with an Inclined plug flow reactor (IPFR) and a nitrification reactor with biofilm media. The denitrification reactor of Module B is designed to be upward flow using IPFR. The result of evaluating at each Task has shown that attached growth system has better capacity of removal efficiency for organic matter and nitrogen with the exception of phosphorus. Task 4 which has the most outstanding removal efficiency has 90.5% of $BOD_{5}$ removal efficiency, 97.8% of ${NH_4}^{+}-N$ removal efficiency, 65% of T-N removal efficiency and 92% of T-P removal efficiency with additional chemical phosphorus removal system operated at HRT 9hr, Qi:Qir 1:2, and BOD/T-N ratio 2.7.

섬유여과기와 전기분해조를 병합한 물 재이용 시스템 설계 (Design of a Water Reuse System Combined with a Fiber Filtration and Electrolysis)

  • 신춘환
    • 한국환경과학회지
    • /
    • 제24권11호
    • /
    • pp.1385-1391
    • /
    • 2015
  • A water reuse system was designed for a demonstration plant by combining fiber filtration and electrolysis. A discharged dye wastewater after treated with biomedia was used in this study. It was found that an additional removal of suspended solids (SS) was feasible with 2-stage filtration while electrolysis was not effective. Also, $COD_{cr}$ and $COD_{Mn}$ were not removed with 2 -stage filtration but electrolysis resulted in about 26.9% additional removal. This indicates that electrolysis play an important role in organic removal. Removal of T-N and T-P was negligible with 1 and 2-stage fiber filtration and low-level electrolyte. However, with 2000 ppm of electrolyte, their removal efficiencies were about 83.1 and 60%, respectively, suggesting that the removal rates are well associated with the electrolyte concentrations. With high-level electrolyte, colority was removed about 82% while chlorine ions were removed only about 10%. Therefore, to treat underground water containing high-level salinity in the follow-up study, based on the results in this paper, a combined system with selection of additional unit process and reverse osmosis will be designed.

바이오가스 마이크로 터빈 발전용 전처리시스템 전산유동해석 (Computational Fluid Dynamics Analysis of the Pretreatment System for Livestock BIO-GAS MGT Power Generation)

  • 허광범;박정극;임상규;김재훈
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.260-263
    • /
    • 2008
  • KEPCO(Korea Electric Power Corporation) is performing the nation's first biogas-MGT project as an effort to encourage the utilization of wasted biogas which contains useful CH4. The goals of this project are to develop the Pretreatment system of Livestock bio-gas and set up the biogas-MGT co-generation system. The project will not only utilze flared biogas as precious energy but also improve the economics of the plant a lot. The pretreatment system mainly consists of sulfur removal tower, biogas compressor and many filtering systems. A computational fluid dynamics study in the bio gas sulfur removal tower and sulfur absorption filter was carried out. Understanding of the flow in the sulfur removal tower and sulfur adsorption filter obtained by this study can be used to identify the problems in the sulfur removal tower and to improve the sulfur removal efficiency of the sulfur removal tower. Resistance material modeling is used to simulate the sulfur adsorption filter, and the resistance coefficient was adjusted to reflect the experimental pressure loss value. And the pressure loss change with the flowrate is predicted

  • PDF

Floating Bead Filter에 의한 순환여과식 양식장의 부유고형물 제거와 질산화 (Removal of Suspended Solids and Nitrification by Floating Bead Filter in Recirculating Aquaculture System)

  • 김병진;김성구;서근학
    • 한국수산과학회지
    • /
    • 제36권2호
    • /
    • pp.163-169
    • /
    • 2003
  • The floating bead filter was tested for treatment of aquacultural water in a pilot-scale recirculating aquaculture system. Performance of floating bead filter on the removal of total suspended solids (TSS) and the treatment of nitrogen sourer such as total ammonia nitrogen (TAN), nitrite nitrogen and nitrate nitrogen were evaluated. The system was stocked with Nile tilapia at an initial rearing densities of $5\%\;and\;7\%$ over 30 days. The average TSS removal rates were $43.0\;g/m^2{\cdot}day\;and\;39.5\;g/m^2{\cdot}day$ for rearing density of $5\%\;and\;7\%$, respectively. As rearing density increased from $5\%\;to\;7\%$. the TAN removal efficiency decreased from $22.0\%\;to\;17.7\%$. At the rearing densities of $5\%\;and\;7\%$, the average TAN removal rates and removal efficiencies were $38.8\;g/m^2{\cdot}day,\;15.6\%\;and\;37.8\;g/m^2{\cdot}day.\;17.7\%,$ respectively. The average TAN removal rate was $37.8-38.8\;g/m^3{\cdot}day.$ The oxygen consumption by floating bead filter was higher than theoretical oxygen consumption rate by nitrification.

정보 시스템 기술을 적용한 제설장비 운영 사례 분석 (Operation Case Analyses of Snow Removal Equipments using Information system Technologies)

  • 김희재;김근영
    • 한국재난정보학회 논문집
    • /
    • 제14권2호
    • /
    • pp.154-164
    • /
    • 2018
  • 연구목적 : 최근 기후변화에 따라 여름철 태풍, 호우와 겨울철 대설, 한파 등의 기상재난이 증가하고 있다. 대설재난은 교통, 건물, 시설물 등에 다양한 피해를 발생시키기 때문에 신속한 대처가 필요하다. 대설재난이 도시 안전에 영향을 주고 있으나 우리나라의 대설재난 대처는 미흡하고, 정책 연구도 부족한 상황이다. 연구방법 : 본 연구는 대설재난이 발생할 때 신속한 도로 제설을 위하여 제설차량과 장비에 정보 통신 기술을 활용한 사례를 분석하고, 시사점을 도출한다. 연구결과 : 도로 제설장비에 정보통신기술이 적용된 장비를 부착하면 긴급 상황시 제설차량과 장비의 위치를 파악하여 인근지역의 도로 제설을 응원할 수 있다. 결론 : 본 연구의 사례 분석은 향후 지자체 제설장비의 효율적 이용을 위해 활용될 수 있다.

Nitrate reduction by iron supported bimetallic catalyst in low and high nitrogen regimes

  • Hamid, Shanawar;Lee, Woojin
    • Advances in environmental research
    • /
    • 제4권4호
    • /
    • pp.263-271
    • /
    • 2015
  • In this study, the effect of initial nitrate loading on nitrate removal and byproduct selectivity was evaluated in a continuous system. Nitrate removal decreased from 100% to 25% with the increase in nitrate loading from 10 to $300mg/L\;NO_3-N$. Ammonium selectivity decreased and nitrite selectivity increased, while nitrogen selectivity showed a peak shape in the same range of nitrate loading. The nitrate removal was enhanced at low catalyst to nitrate ratios and 100% nitrate removal was achieved at catalyst to nitrate ratio of ${\geq}33mg\;catalyst/mg\;NO_3-N$. Maximum nitrogen selectivity (47%) was observed at $66mg\;catalyst/mg\;NO_3-N$, showing that continuous Cu-Pd-NZVI system has a maximum removal capacity of 37 mg $NO_3{^-}-N/g_{catalyst}/h$. The results from this study emphasize that nitrate reduction in a bimetallic catalytic system could be sensitive to changes in optimized regimes.

SBR공정에서 영양염류 제거에 대한 염분의 영향 (The Effect of Salinity on Biological Nutrient Removal in SBR)

  • 송창수;오준성
    • 한국물환경학회지
    • /
    • 제18권3호
    • /
    • pp.237-243
    • /
    • 2002
  • The effect of a salinity on the performance of a biological nutrient removal system was investigated using a model SBR(Sequencing Bach Reactor) system. The system was operated at a 12hr, 18hr, 24hr, and 36hr HRT with a salinity level of 20,000mg/L and compared with a system similarly operated with fresh water. The influent salinity level of 8,000 mg/L does not have a significant effect on BOD removal efficiency, there is a noticeable decrease in BOD removal rate from 10,000 mg Cl-/L. The Nitrogen could be removed from the saline wastewater with the same efficiency as for the fresh water because of low C/N ratio in anoxic period. The excess biological phosphorous removal is highly affected by the increase in the influent salinity. The efficiency is decreased from 96.6% to 43.4% when the influent salinity is increased from 0 to 20,000mg/L.

실험실적 규모의 분무흡수건조반응기의 배출가스 중 아황산가스 처리성능 연구 (Flue Gas Sulfur Dioxide Removal Performance of a Bench-Scale Spray Absorption/Drying Reactor)

  • 동종인;구우회;임대현
    • 한국대기환경학회지
    • /
    • 제12권4호
    • /
    • pp.449-457
    • /
    • 1996
  • The main purpose of this study was to investigate sulfur dioxide removal performance of flue gas desulfurization system utilizing a Spray Absorption/Drying Reactor. In this system, the size of droplets was considered the most significant factor and tested using a PDA system. Lime slurry flow rate, operating temperature, calcium/sulfur (Ca/S) ratio and applied air pressure were selected as major operation variables and tested/analyzed in terms of system performance. The results are as follows. 1. The $SO_2$ removal efficiencies were 49%, 74%, 85% for Ca$(OH)_2$ slurry flow rate of 10, 20, 30 ml/min, which implies that the increase of slurry flow rate improves removal efficiency. The optimum slurry flow rate in this study was, however, considered 20 ml/min because of constraints of system troubles and absorbent utilization. 2. As Ca/S ratio increased, $SO_2$ removal efficiency was observed to increase. 3. As air pressure, at the atomizing nozzole, increased from 3 to 5 $kg/cm^2, SO_2$ removal efficiency increased from 74% to 80%, because of droplet size reduction due to pressure increase during atomizing process and the increase of surface area, helping mass transfer between gas and liquid phase.

  • PDF