• Title/Summary/Keyword: removal efficiencies

Search Result 1,115, Processing Time 0.038 seconds

Removal Property of Taste and Odor Causing Material in Pulsator Clarifier (맥동식 침전지에서 맛·냄새 유발물질 제거 특성)

  • Jeong, Il Yong;Cha, Min Whan
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.1
    • /
    • pp.104-109
    • /
    • 2011
  • The removal efficiencies of 2-methylisoborneol (MIB) and geosmin were investigated to reveal removal characteristics of typical organic compounds causing disagreeable taste and odor at the conventional water treatment plant installed with pulsator clarifier patented by the French company $Degr{\acute{e}}mont$. The injection rate of Powdered Activated Carbon (PAC) into water was changed step wisely as we conducted jar tests in the laboratory and water treatment in the actual plant. 2-MIB concentration decreased linearly while geosmin did exponentially along with the injection rate of PAC at our jar tests. The removal efficiency of geosmin by PAC injection was considerably higher than that of 2-MIB. In the real pulsator clarifier, 2-MIB concentration started decreasing as the injection rate reached up to 10 mg/L of PAC. On the other hand, the concentration of geosmin in water decreased proportional to the injection rate of PAC. In the sand filtration, removal efficiencies of 2-MIB and geosmin on July were much higher than those on March. It was carefully suggested beforehand and found afterwards that general microorganisms notably existed in the sand filter with no chlorine in filter influent and backwash water and the sand filter biologically activated removed much more odor compounds. It was considered as the reason why the removal efficiency of 2-MIB and geosmin was increased. The microbial activity maybe increased in summer with water temperature rising and low filtration rate possibly increased contact time between odor compounds and general microorganisms.

Assessment of Effluent Limitation for K Leather Industry Wastewater (K피혁폐수 처리시설에 대한 배출허용기준 평가)

  • Yang, Hyung-Jae;Kwon, Oh-Sang;Kim, Jae-Hoon;Lee, Sung-Jong;Jung, Dong-Il;Kim, Sang-Hoon
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.2
    • /
    • pp.41-52
    • /
    • 2007
  • K leather industry wastewater treatment plant(advanced treatment process) was selected to evaluate effluent quality and pollutants removal efficiencies. $BOD_5$ concentration of effluent was $3.95mg/{\ell}$ and its removal efficiency was 99.8%. Also, most of other pollutants removal efficiencies were over 90% as well. And 95% reliability of effluent concentration were $106.8mg/{\ell}$ of CODmn, $86mg/{\ell}$ of SS, $72.04mg/{\ell}$ of TN that is greater than the effluent limitation, $0.98mg/{\ell}$ of ABS, $1.8mg/{\ell}$ of n-Hexane, $9.7mg/{\ell}$ of $BOD_5$ and $0.11mg/{\ell}$ of Cr.

Efficiency Evaluation of Adsorbents for the Removal of VOC and NO2 in an Underground Subway Station

  • Son, Youn-Suk;Kang, Young-Hoon;Chung, Sang-Gwi;Park, Hyun-Ju;Kim, Jo-Chun
    • Asian Journal of Atmospheric Environment
    • /
    • v.5 no.2
    • /
    • pp.113-120
    • /
    • 2011
  • Adsorbent combination studies have been carried out to remove nitrogen dioxide ($NO_2$) and volatile organic compounds (VOCs: BTEX) out of a subway environment characterized by high flow and low concentration. Optimal conditions for the high removal efficiency of the concerned target compounds were obtained through testing a series of control factors such as adsorbent sorts, thicknesses, and superficial velocity. It was found that the efficiencies increased as the specific surface area of activated carbon and its thickness increased, and external void fraction decreased. Furthermore, mixed activated carbon with granular and constructed contents was extensively tested to reduce pressure drop through the carbon bed. It was found that the performance of higher contents of granular activated carbon was better than that of higher contents of the constructed carbon. When the mixed carbon was applied to the subway ventilation system in order to eliminate $NO_2$ and VOC simultaneously, the removal efficiencies were found to be 75% and 85%, respectively.

Effects of Microwave Pretreatment on Mesophilic Anaerobic Digestion for Mixture of Primary and Secondary Sludges Compared with Thermal Pretreatment

  • Park, Woon-Ji;Ahn, Johng-Hwa
    • Environmental Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.103-109
    • /
    • 2011
  • This work experimentally determined the effect of thermal and microwave pretreatments on the anaerobic digestion of mixtures of municipal primary and secondary sludges in semi-continuous mesophilic digesters at hydraulic retention times (HRT) of 20, 15, 10, 7, and 5 days. The ratio of soluble chemical oxygen demand (COD) to total COD in thermally pretreated and microwaved sludges at $80^{\circ}C$ was 2.7 and 3.2 times higher than that of raw sludge, respectively. The volatile solids (VS) and COD removal efficiencies in all three digesters fed with raw (control), thermally pretreated (TM), and microwaved (MW) sludges decreased as the HRT was reduced. The highest relative improvement in VS removal compared to the control occurred at the HRT of 5 days in the TM and MW (29 and 41% higher than the control, respectively). At this HRT, improvement in the COD removal efficiencies in the TM and MW compared to the control was 28 and 53%, respectively. Improvements in biogas production compared with the control increased in both the TM and MW as the HRT was reduced to 5 days. The relative improvement in daily biogas production compared to the control from the TM and MW was 33 and 53% higher than the control at the HRT of 5 days, respectively. The results show that microwave pretreatment is more effective than thermal pretreatment in increasing the solubilization degree and mesophilic anaerobic biodegradability of sewage sludge.

Photocatalytic Destruction of Chlorinated and Aromatic Hydrocarbons for Low-Level Indoor Air Cleaning (저농도 실내공기 정화를 위한 염소화 및 방향족 탄화수소의 광촉매 분해)

  • Jo, Wan Geun;Gwon, Gi Dong;Choe, Sang Jun;Song, Dong Ik
    • Journal of Environmental Science International
    • /
    • v.13 no.9
    • /
    • pp.767-777
    • /
    • 2004
  • This study evaluated the technical feasibility of the application of $TiO_2$ photocatalysis for the removal of volatile hydrocarbons(VHC) at low ppb concentrations commonly associated with non-occupational indoor air quality issues. A series of experiments was conducted to evaluate five parameters (relative humidity (RH), hydraulic diameter (HD), feeding type (FT) of VHC, photocatalytic oxidation (PCO) reactor material (RM), and inlet port size (IPS) of PCO reactor) for the PCO destruction efficiencies of the selected target VHC. None of the target VHC presented significant dependence on the RH, which are inconsistent with a certain previous study that reported that under conditions of low humidity and a ppm toluene inlet level, there was a drop in the PCO efficiency with decreasing humidity. However, it is noted that the four parameters (HD, RM, FT and IPS) should be considered for better VHC removal efficiencies for the application of $TiO_2$ photocatalytic technology for cleansing non-occupational indoor air. The PCO destruction of VHC at concentrations associated with non-occupational indoor air quality issues can be up to nearly 100%. The amount of CO generated during PCO were a negligible addition to the indoor CO levels. These abilities can make the PCO reactor an important tool in the effort to improve non-occupational indoor air quality.

Comparison of Phosphorus and Nitrogen Removal Characteristics between A2/O and Modified Phostrip Processes (A2/O공정과 수정 Phostrip공정과의 질소 및 인제거 특성비교)

  • Kim, Kwang-Soo;Kim, I-Tai
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.6
    • /
    • pp.664-668
    • /
    • 2005
  • An experimental study for the comparison of nitrogen and phosphorus removal efficiencies between $A^2/O$ and modified Phostrip (M-Phostrip process) were carried out with bench-scale reactors. In case of nitrogen removal efficiencies both of processes showed similar ones when influent organic loadings were high. However, M-phostrip process was more effective than $A^2/O$ at low organic loadings. This is why M-phostrip process consumes the whole mass of influent organics as a carbon sources for denitrification in anoxic reactor but the anoxic reactor of $A^2/O$ process utilizes the residual carbon followed by consumming a part of influent carbon for phosphorus release in anaerobic reactor. $A^2/O$ process required the influent COD/T-P and COD/TKN ratios were more than 56 and 10, respectively, to take place the phosphorus release in anaerobic process and phosphorus uptake in oxic process. However, the luxury uptake of phosphorus in M-phostrip process was not affected by influent COD/T-P and COD/TKN ratios and the adverse effect of nitrate in return sludge introduced to the p-stripper from the 2nd clarifier was not significant due to the configurational advantage of the p-stripper.

The Effects of pH and Dosages According to Qualities of Raw Waters and Basicity of Coagulants (원수 수질특성과 응집제 염기도에 따른 응집 pH 및 주입량의 영향)

  • Park, Noh-Back;Lee, Bum;Tian, Dong-Jie;Lee, Young-Ju;Jun, Hang-Bae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.581-593
    • /
    • 2010
  • The objectives of this study were to investigate the effects of raw water pH and basicity of coagulants on turbidity removal with several raw waters having different level of turbidity, alkalinity and pH. Raw waters were sampled from M, S and B water treatment plants(WTP) located at Miryang, Nakdong, Han river, respectively. Six coagulants which have different levels of basicity and aluminum contents were used for this evaluation. High basicity of the coagulant helped to properly control coagulation processes for treating turbid and low alkali raw water. It was difficult for operators to determine optimum coagulant dose for high basicity coagulants, since residual turbidity tended to decrease continuously as coagulant dose increased. Turbidity removal efficiencies with high basicity coagulants(E and F) were higher than the other coagulants at ambient pH for the M WTP. Turbidity removal efficiencies, however, at adjusted pH 7.0 showed similar among six coagulants. Residual turbidity kept low at excess dosages with high basicity coagulants. Optimum coagulant dosages at adjusted pH 7.0 showed higher than those at ambient pH in M WTP. On the contrary in B WTP, optimum coagulant dosage at ambient pH were higher than that at adjusted pH 7.0.

A study on the removal of particulate matters using unidirectional flushing (단방향 플러싱에 의한 입자성 물질의 제거에 관한 연구)

  • Kim, Dooil;Cheon, Subin;Hyun, Inhwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.3
    • /
    • pp.371-380
    • /
    • 2015
  • Particulate matters in a water distribution system are main causes of turbidity and discoloration of tap water. They could be removed by conventional or uni-directional flushing in a water distribution system. The behaviors and required flow velocity of particles are not well known for their flushing. A model water main and hydrant were made from transparent acrylic pipe of 30mm and 16mm in diameter, respectively. We analyzed the effect of flushing velocity, particle density, and particle diameter. We found that the existence of break-though velocities at which particles begin to be removed, and which are affected by their physical properties. The removal efficiencies seemed to be influenced by resuspension capabilities related to their upward movement from the bottom. Heavy particles like scale were hard to remove through upflow hydrant because the falling velocity, calculated using Stokes' law, was higher. Particle removal efficiencies of upward hydrant and downward drain showed minor differences. Additionally, the length between hydrant and control valve affected flushing efficiency because the particulate matters were trapped in this space by inertia and recirculating flow.