• Title/Summary/Keyword: remodeling for apartments

Search Result 78, Processing Time 0.022 seconds

Survey on Apartment Dwellers' Perception of Housing Environment in Daejeon City (대전지역 아파트 거주자의 주거의식에 관한 조사연구)

  • Choi, Byung-Sook;Kang, In-Ho;Park, Jung-A;Jang, Hye-Sun;Jung, Mi-Hyeon
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.339-344
    • /
    • 2008
  • The purpose of this study was to find out the residents' perceptive opinions of apartment housing environment and to contribute to develop a apartment unit plan in Daejeon City. This research was performed by a questionnaire survey method, 464 data was collected from apartment residents lived in about $85m^2$ unit with 3 rooms and the apartments was limited to the complexes within 3 years at Yuseong-gu and Seo-gu. By analyzing those data, findings are as follows: 1) Residents thought living room, kitchen and bathroom were importment space in a unit plan. They needed a storage function in an entrance and a intermediate room, and Anbang(materbed room) so did. L-DK plan type was very preferred. 2) Sub-kitchen was needed for a refrigerator of Kinch, the location of it was realted to a main kitchen and a uitility. the third room was needed for library, home office and storage space. 3) The enlargment remodeling of balcony was showed livingroom balcony or personal bedrooms at the time of occupancy. They needed the balcony near a kitchen or an utility to equip a storage facility. And residents were preferred to their taste rather than a choice of interior concept package services.

  • PDF

A Study of Prestressed Concrete Pile Stiffness for Structural Analysis of Condominium Remodeling with Vertical Story Extension (수직증축형 공동주택 리모델링 구조해석을 위한 PC말뚝 강성에 관한 연구)

  • Choi, Changho;Lee, Hyunjee;Choi, Kisun;You, Youngchan;Kim, Jinyoung
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.12
    • /
    • pp.81-92
    • /
    • 2017
  • According to the revision of the Housing Act in 2013, it has been possible to carry out an apartment remodeling project involving two to three floor vertical extension. The remodeling project with vertical extension requires foundation reinforcement because structural safety due to additional load and enhanced seismic criteria must be met. In this case, structural analysis is performed to analyze the load distributed to existing PC pile and reinforced additional pile. The vertical stiffness ($K_v$) of the pile is required for structural analysis, but the research on the 20~30 year old PC pile stiffness is very limited. In this paper, the stiffness of the PC pile in accordance with the change of diameter and length was analyzed by examining the results of 38 field pile load tests performed during the construction of the apartments in the 1990's. As a result of the analysis, the pile stiffness decreases with the increase of the length-diameter ratio (L/D). In addition, the results of on-site pile load test are compared with the coefficient 'a' for estimating pile stiffness proposed in Korea Highway Bridge Design Standard (2008) and the Pile Foundation Design Guideline of Korea Railroad Corporation (2012). It shows that 'a' obtained through the estimation of the literature is very similar to the field test results in the range of 10

A Study on the Energy Performance Evaluation of Window System with the Balcony Types of Apartments (공동주택 세대내 발코니 유형별 창호의 냉난방 에너지 성능분석 연구)

  • Yoon, Jong-Ho;An, Young-Sub;Kim, Byoung-Soo;Hwang, Sang-Kun
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.1
    • /
    • pp.83-90
    • /
    • 2007
  • Apartment balcony has been indiscreetly remodeled since the government permitted remodeling on January 2006. But remodeled balcony has a few problems such as increase of heating energy, surface condensation and cold draft. The reason of thermal problem is mainly caused by the window system in a extended balcony. The purpose of this study is to analyze heating and cooling energy and propose the efficient window types for the extended balcony area of a apartment building. 4 types of window system which have fairly high U value in Korea are investigated as follows ; double clear glass, double low-e glass, triple clear glass and triple low-e glass. Comparing double clear 91ass with double low-e glass, triple clear glass and triple low-e glass, simulation results show that 10%, 7% and 15% saving of total primary energy can be expected.

A Study on the Comparison of Simulation for Heat Loss According to the Installation of Windows for Openings in External Wall of One Side Corridor Type Apartments (편복도식 아파트에서 복도 외측 창호의 설치 유무에 따른 열손실 시뮬레이션 비교 연구)

  • Kim, Dae-Won;Chung, Kwang-Seop;Kim, Young-Il;Kim, Sung-Min
    • Journal of Energy Engineering
    • /
    • v.22 no.1
    • /
    • pp.51-57
    • /
    • 2013
  • As energy becomes an important source of power for national competitive force, not only Government administrations but also private sectors are striving to save energy. The purpose of this study is to compare and evaluate energy consumption of the corridor with and without window when improving the energy environment by installing door and window on the open area of entrance for one-side corridor type apartment. The energy usage was examined through this improvement process and the energy consumption amount was compared and analyzed by simulation before and after the installation. It is desired for this study to contribute to the government's green remodeling project.

Analysis of VOCs Infiluencing Environment Factors Using Statistics in Apartment House (통계분석을 이용한 아파트내 휘발성유기화합물의 환경인자 분석)

  • Lee, Se-Haeng;Kim, Nan-Hee;Lee, Kyoung-Soek;Park, Kang-Soo;Park, Seung-Yeol;Kim, Do-Sool;Kang, Yeong-Ju;Kim, Eun-Sun;Kim, Dong-Su
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.4
    • /
    • pp.435-445
    • /
    • 2012
  • The aim of this study is to understand the characteristics of volatile oranic compounds (VOCs) and provide information about the present Indoor Air Quality (IAQ) at residential apartments. All samples were collected in 60-min interval using the tenax absorption trap between May, 2011 and February, 2012. And the effects of environmental factors such as temperature, humidity and construction characteristics were analyzed in relation to the measured concentrations. The results of this study showed that the mean concentration of VOCs was lower than the Ministry of the Environment's standards for maintenance of indoor air quality. The correlation analysis showed that ethylbenzene and xylene (r=0.916, p<0.01), toluene and ehtylbenzene (r=0.810, p<0.01), toluene and xylene (r=0.803, p<0.01) and toluene and styrene (r=0.588, p<0.01) were significant. The result of regression analysis was found that the influenece factors associated with the concentration of VOCs were the age and location of the apartment, remodeling, the temperature and the season.

A Study on the Improvement of composition structural system for the apartment with space variability (공간 가변형 공동주택의 복합구조시스템 개선에 관한 연구)

  • Koo, Kyo-Jun;Lee, Jeong-Cheol;Lee, Chan-Sik
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.353-357
    • /
    • 2007
  • The Apartment resident's make-up of a family and residing preference are diversified by the change of lifestyle through the elevation of economy level and residing level. Accordingly, the remodeling and the early rebuilding for the satisfaction of a life cycle and a life style are increasing, and "Variability" that is the concept of Open Housing was emphasized as a central of residing plan in the apartment. Although apartments which select the space variability to the residing space are increasing gradually, the optimum composition structural system with space variability that satisfies the structure stability, the economical efficiency and the resident usability is not developed. The method of a study was progressed by a comparison and an analysis on each system with estimation elements through analyzing the development process and the special quality of existing composition structural system with space variability in the apartment. This paper offered the improvement direction on the current composition structural system with space variability for the development of modularizing system that is correct in domestic real condition.

  • PDF

Shear Strength Reduction Ratio of Reinforced Concrete Shear Walls with Openings (개구부를 갖는 철근콘크리트 전단벽의 전단강도 저감률)

  • Bae, Baek-Il;Choi, Yun-Cheul;Choi, Chang-Sik;Choi, Hyun-Ki
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.4
    • /
    • pp.451-460
    • /
    • 2010
  • There are many types of remodeling, however, engineers and architectures preferred to merge two or more separate units to one very spacious unit. Performing this type of remodeling, in the case of wall dominant apartments, requires partial removal of structural wall causing a concern of structural integrity. However, there are insufficient studies about partial removal, that is, openings. Presently, ACI standard have no clear way to evaluate the effect of opening on the structural wall. AIJ has the provision about strength reduction factor '$\gamma$'. However, this reduction factor cannot exactly evaluate the reduction effect of openings because this factor '$\gamma$' was determined through the elastic analysis. Therefore, in this study, 2 structural wall specimens were tested and many test results from previous studies were collected. Using these data, this study performed statistical analysis about strength of structural wall which have the opening in wall panel. And this study performed parametric study verifying shear strength reducing effect by opening area. In the results of statistical study, previous reduction factor show very conservative results because this equation did not consider other factors, reinforcement ratio and aspect ratio of openings, which was affect the shear strength of shear walls. Therefore we performed parametric study based on the test data and suggest new equation for shear strength reduction factor '$\gamma$'.

Survey on Condominium Apartment Dwellers' Consciousness of Unit Plan in Daejeon City (대전지역 아파트 단위주호 계획에 대한 거주자의 주거의식에 관한 조사연구)

  • Choi, Byung-Sook;Kang, In-Ho;Park, Jung-A;Jung, Mi-Hyeon;Jang, Hye-Sun
    • Journal of the Korean housing association
    • /
    • v.20 no.5
    • /
    • pp.31-39
    • /
    • 2009
  • The purpose of this study was to find out the residents' consciousness of the unit plan on condominium apartment and to contribute to develop a condominium apartment unit plan in Daejeon City. This research was performed by a questionnaire survey method, 464 data was collected from apartment residents lived in about $85\;m^2$ unit with 3 rooms and the apartments was limited to the complexes within 1-4 years of the length of building at Yuseong-gu and Seo-gu. By analyzing those data, findings are as follows: 1) Residents thought living room, kitchen and bathroom were importment space in a unit plan. They needed a storage function in an entrance and a intermediate room, and Anbang(mater bedroom) so did. 2) L-DK plan type was very popular and the type of front DK with L on the floor plan was preferred. This was unique results. 3) Sub-kitchen was needed for a refrigerator of Kimchi, the location of it was related to a main kitchen and a utility. the third room was needed for library, home office and storage space. 3) Bath-tub in An-bang and showe-booth in public bathroom was preferred. This was same to the popular trend of Korean condominium apartment. 4) The enlargment remodeling of balcony was showed livingroom balcony or personal bedrooms at the time of occupancy. They needed the balcony near a kitchen or an utility to equip a storage facility. Additionally, residents were preferred to their taste rather than a choice of interior concept package services.