• Title/Summary/Keyword: reliable index

Search Result 624, Processing Time 0.031 seconds

A comparison of acoustic measures among the microphone types for smartphone recordings in normal adults (정상 성인에서 스마트폰 녹음을 위한 마이크 유형 간 음향학적 측정치 비교)

  • Jeong In Park;Seung Jin Lee
    • Phonetics and Speech Sciences
    • /
    • v.16 no.2
    • /
    • pp.49-58
    • /
    • 2024
  • This study aimed to compare the acoustic measurements of speech samples recorded from individuals with normal voices using various devices: the Computerized Speech Lab (CSL), a unidirectional wired pin-microphone (WIRED) suitable for smartphones, the built-in omnidirectional microphone (SMART) of smartphones, and Bluetooth-connected wireless earphones, specifically the Galaxy Buds2 Pro (WIRELESS). This study included 40 normal adults (12 males and 28 females) who had not visited an otolaryngologist for respiratory diseases within the past three months. Participants performed sustained vowel /a/ phonation for four seconds and reading tasks with sentences ("Walk") and paragraphs ("Autumn") in a sound-treated booth. Recordings were simultaneously conducted using the four different devices and synchronized based on the CSL-recorded samples for analysis using the MDVP, ADSV, and VOXplot programs. Compared with CSL, the Cepstral Spectral Index of Dysphonia (CSIDV, CSIDS) and Acoustic Voice Quality Index (AVQI) values were lower in the WIRED and higher in the SMART. The opposite trend was observed for the L/H spectral ratios (SRV and SRS), and the WIRELESS demonstrated task-specific discrepancies. Furthermore, both the fundamental frequency (F0) and the cepstral peak prominence of the vowel samples (CPPV) had intraclass correlation coefficient (ICC) values above 0.9, indicating high reliability. These variables, F0 and CPPV were considered highly reliable for voice recordings across different microphone types. However, caution should be exercised when analyzing and interpreting variables such as the SR, CSID, and AVQI, which may be influenced by the type of microphone used.

Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period (호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증)

  • Jeon, Soo Dong;Bae, Sun Myung;Yoon, In Ha;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the patient's breathing cycle in Gated Volumetric Modulated Arc Therapy Materials and Methods : TrueBeam STxTM(Varian Medical System, Palo Alto, CA) was used in this experiment. The Computed tomography(CT) images that were acquired with RANDO Phantom(Alderson Research Laboratories Inc. Stamford. CT, USA), using Computerized treatment planning system(Eclipse 10.0, Varian, USA), were used to create VMAT plans using 10MV FFF with 1500 cGy/fx (case 1, 2, 3) and 220 cGy/fx(case 4, 5, 6) of doserate of 1200 MU/min. The regular respiratory period of 1.5, 2.5, 3.5 and 4.5 sec and the patients respiratory period of 2.2 and 3.5 sec were reproduced with the $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc), and it was set up to deliver radiation at the phase mode between the ranges of 30 to 70%. The results were measured at respective respiratory conditions by a 2-Dimensional ion chamber array detector(I'mRT Matrixx, IBA Dosimetry, Germany) and a MultiCube Phantom(IBA Dosimetry, Germany), and the Gamma pass rate(3 mm, 3%) were compared by the IMRT analysis program(OmniPro I'mRT system software Version 1.7b, IBA Dosimetry, Germany) Results : The gamma pass rates of Case 1, 2, 3, 4, 5 and 6 were the results of 100.0, 97.6, 98.1, 96.3, 93.0, 94.8% at a regular respiratory period of 1.5 sec and 98.8, 99.5, 97.5, 99.5, 98.3, 99.6% at 2.5 sec, 99.6, 96.6, 97.5, 99.2, 97.8, 99.1% at 3.5 sec and 99.4, 96.3, 97.2, 99.0, 98.0, 99.3% at 4.5 sec, respectively. When a patient's respiration was reproduced, 97.7, 95.4, 96.2, 98.9, 96.2, 98.4% at average respiratory period of 2.2 sec, and 97.3, 97.5, 96.8, 100.0, 99.3, 99.8% at 3.5 sec, respectively. Conclusion : The experiment showed clinically reliable results of a Gamma pass rate of 95% or more when 2.5 sec or more of a regular breathing period and the patient's breathing were reproduced. While it showed the results of 93.0% and 94.8% at a regular breathing period of 1.5 sec of Case 5 and 6, it could be confirmed that the accurate dose delivery could be possible on the most respiratory conditions because based on the results of 100 patients's respiratory period analysis as no one sustained a respiration of 1.5 sec. But, pretreatment dose verification should be precede because we can't exclude the possibility of error occurrence due to extremely short respiratory period, also a training at the simulation and careful monitoring are necessary for a patient to maintain stable breathing. Consequently, more reliable and accurate treatments can be administered.

Improvement in Regional Contractility of Myocardium after CABG (관상동맥 우회로 수술 환자에서 심근의 탄성도 변화)

  • Lee, Byeong-Il;Paeng, Jin-Chul;Lee, Dong-Soo;Lee, Jae-Sung;Chung, June-Key;Lee, Myung-Chul;Choi, Heung-Kook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.224-230
    • /
    • 2005
  • Purpose: The maximal elastance ($E_{max}$) of myocardium has been established as a reliable load-independent contractility index. Recently, we developed a noninvasive method to measure the regional contractility using gated myocardial SPECT and arterial tonometry data. In this study, we measured regional $E_{max}(rE_{max}$ in the patients who underwent coronary artery bypass graft surgery (CABG), and assessed its relationship with other variables. Materials and Methods: 21 patients (M:F=17:4, $58{\pm}12$ y) who underwent CABG were enrolled. $^{201}TI$ rest/dipyridamole stress $^{99m}Tc$-sestamibi gated SPECT were performed before and 3 months after CABG. For 15 myocardial regions, regional time-elastance curve was obtained using the pressure data of tonometry and the volume data of gated SPECT. To investigate the coupling with myocardial function, preoperative regional $E_{max}$ was compared with regional perfusion and systolic thickening. In addition, the correlation between $E_{max}$ and viability was assessed in dysfunctional segments (thickening <20% before CABG). The viability was defined as improvement of postoperative systolic thickening more than 10%. Results: Regional $E_{max}$ was slightly increased after CABG from $2.41{\pm}1.64 (pre)\;to\;2.78{\pm}1.83 (post)$ mmHg/ml. $E_{max}$ had weak correlation with perfusion and thickening (r=0.35, p<0.001). In the regions of preserved perfusion (${\geq}60%$), $E_{max}$ was $2.65{\pm}1.67$, while it was $1.30{\pm}1.24$ in the segments of decreased perfusion. With regard to thickening, $E_{max}$ was $3.01{\pm}1.92$ mmHg/ml for normal regions (thickening ${geq}40%$), $2.40{\pm}1.19$ mmHg/ml for mildly dysfunctional regions (<40% and ${\geq}20%$), and $1.13{\pm}0.89$ mmHg/ml for severely dysfunctional regions (<20%). $E_{max}$ was improved after CABG in both the viable (from $1.27{\pm}1.07\;to\;1.79{\pm}1.48$ mmHg/ml) and non-viable segments (from $0.97 {\pm}0.59\;to\;1.22{\pm}0.71$ mmHg/ml), but there was no correlation between $E_{max}$ and thickening improvements (r=0.007). Conclusions: Preoperative regional $E_{max}$ was relatively concordant with regional perfusion and systolic thickening on gated myocardial SPECT. In dysfunctional but viable segments, $E_{max}$ was improved after CABG, but showed no correlation with thickening improvement. As a load-independent contractility index of dysfunctional myocardial segments, we suggest that the regional $E_{max}$ could be an independent parameter in the assessment of myocardial function.

The Usefulness of Dyspnea Rating in Evaluation for Pulmonary Impairment/Disability in Patients with Chronic Pulmonary Disease (만성폐질환자의 폐기능손상 및 장애 평가에 있어서 호흡곤란정도의 유용성)

  • Park, Jae-Min;Lee, Jun-Gu;Kim, Young-Sam;Chang, Yoon-Soo;Ahn, Kang-Hyun;Cho, Hyun-Myung;Kim, Se-Kyu;Chang, Joon;Kim, Sung-Kyu;Lee, Won-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.2
    • /
    • pp.204-214
    • /
    • 1999
  • Background: Resting pulmonary function tests(PFTs) are routinely used in the evaluation of pulmonary impairment/disability. But the significance of the cardiopulmonary exercise test(CPX) in the evaluation of pulmonary impairment is controvertible. Many experts believe that dyspnea, though a necessary part of the assessment, is not a reliable predictor of impairment. Nevertheless, oxygen requirements of an organism at rest are different from at activity or exercising, and a clear relationship between resting PFTs and exercise tolerance has not been established in patients with chronic pulmonary disease. As well, the relationship between resting PFTs and dyspnea is complex. To investigate the relationship of dyspnea, resting PFTs, and CPX, we evaluated the patients of stabilized chronic pulmonary disease with clinical dyspnea rating(baseline dyspnea index, BDI), resting PFTs, and CPX. Method: The 50 patients were divided into two groups: non-severe and severe group on basis of results of resting PFTs(by criteria of ATS), CPX(by criteria of ATS or Ortega), and dyspnea rating(by focal score of BDI). Groups were compared with respect to pulmonary function, indices of CPX, and dyspnea rating. Results: 1. According to the criteria of pulmonary impairment with resting PFTs, $VO_2$max, and focal score of BDI were significantly low in the severe group(p<0.01). According to the criteria of $VO_2$max(ml/kg/min) and $VO_2$max(%), the parameters of resting PFTs, except $FEV_1$ were not significantly different between non-severe and severe(p>0.05). According to focal score($FEV_1$(%), FVC(%), MW(%), $FEV_1/FVC$, and $VO_2$max were significantly lower in the severe group(p<0.01). However, in the more severe dyspneic group(focal score<5), only $VO_2$max(ml/kg/min) and $VO_2$max(%) were low(p<0.01). $FEV_1$(%) was correlated with $VO_2$max(%)(r=0.52;p<0.01), but not predictive of exercise performance. The focal score had the correlation with max WR(%) (r=0.55;p<0.01). Sensitivity and specificity analysis were utilized to compare the different criteria used to evaluate the severity of pulmonary impairment, revealed that the classification would be different according to the criteria used. And focal score for dyspnea showed similar sensitivity and specificity. Conclusion : According to these result, resting PFTs were not superior to rating of dyspnea in prediction of exercise performance in patients with chronic pulmonary diseases and less correlative with focal score for dyspnea than $VO_2$max and max WR. Therefore, if not contraindicated, CPX would be considered to evaluate the severity of pulmonary impairment in patients with chronic pulmonary diseases, including with severe resting PFTs. Current criteria used to evaluate the severity of impairment were insufficient in considering the degree of dyspnea, so new criteria, including the severity of dyspnea, may be necessary.

  • PDF

Improvement and Validation of an Analytical Method for Quercetin-3-𝑜-gentiobioside and Isoquercitrin in Abelmoschus esculentus L. Moench (오크라 분말의 Quercetin-3-𝑜-Gentiobioside 및 Isoquercitrin의 분석법 개선 및 검증)

  • Han, Xionggao;Choi, Sun-Il;Men, Xiao;Lee, Se-jeong;Jin, Heegu;Oh, Hyun-Ji;Cho, Sehaeng;Lee, Boo-Yong;Lee, Ok-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.2
    • /
    • pp.39-45
    • /
    • 2022
  • This study aimed to investigate the validation and modify the analytical method to determine quercetin-3-𝑜-gentiobioside and isoquercitrin in Abelmoschus esculentus L. Moench for the standardization of ingredients in development of functional health products. The analytical method was validated based on the ICH (International Conference for Harmonization) guidelines to verify the reliability and validity there of on the specificity, linearity, accuracy, precision, detection limit and quantification limit. For the HPLC analysis method, the peak retention time of the index component of the standard solution and the peak retention time of the index component of A. esculentus L. Moench powder sample were consistent with the spectra thereof, confirming the specificity. The calibration curves of quercetin-3-𝑜-gentiobioside and isoquercitrin showed a linearity with a near-one correlation coefficient (0.9999 and 0.9999), indicating the high suitability thereof for the analysis. A. esculentus L. Moench powder sample of a known concentration were prepared with low, medium, and high concentrations of standard substances and were calculated for the precision and accuracy. The precision of quercetin-3-𝑜-gentiobioside and isoquercitrin was confirmed for intra-day and daily. As a result, the intra-day precision was found to be 0.50-1.48% and 0.77-2.87%, and the daily precision to be 0.07-3.37% and 0.58-1.37%, implying an excellent precision at level below 5%. As a result of accuracy measurement, the intra-day accuracy of quercetin-3-𝑜-gentiobioside and isoquercitrin was found to be 104.87-109.64% and the daily accuracy thereof was found to be 106.85-109.06%, reflecting high level of accuracy. The detection limits of quercetin-3-𝑜-gentiobioside and isoquercitrin were 0.24 ㎍/mL and 0.16 ㎍/mL, respectively, whereas the quantitation limits were 0.71 ㎍/mL and 0.49 ㎍/mL, confirming that detection was valid at the low concentrations as well. From the analysis, the established analytical method was proven to be excellent with high level of results from the verification on the specificity, linearity, precision, accuracy, detection limit and quantitation limit thereof. In addition, as a result of analyzing the content of A. esculentus L. Moench powder samples using a validated analytical method, quercetin-3-𝑜-gentiobioside was analyzed to contain 1.49±0.01 mg/dry weight g, while isoquercitrin contained 1.39±0.01 mg/dry weight g. The study was conducted to verify that the simultaneous analysis on quercetin-3-𝑜-gentiobioside and isoquercitrin, the indicators of A. esculentus L. Moench, is a scientifically reliable and suitable analytical method.

Relationship Between Vaginal Cytology and Reproductive Hormone During the Estrous Cycle in Korea Jin-do Bitches (진돗개에서 발정주기 동안 질세포상과 번식호르몬의 관계)

  • 손창호;김정훈;정경아;강현구;오기석;박인철;박상국;한호재
    • Journal of Veterinary Clinics
    • /
    • v.17 no.1
    • /
    • pp.225-233
    • /
    • 2000
  • The aim in this study was to obtain the basic data for estimation of optimal mating time and ovulation time by finding out the relationship between vaginal cytology and reproductive hormone profiles during the estrous cycle in 36 Korea Jin-do bitches. A characteristic features of vaginal cytology during the estorous cycle were the high proportion of superficial cell, anuclear cell and erythrocyte in proestrus, superficial cell, anuclear cell and erythroucyte in estrus, parabasal cell, small and large intermediate cell and leukocytes in diestrus, and parabasal cell and small intermediate cell in anestrus, respectively. Cornification index(CI) was the high proportion in proestrus and estrus, then it was decreaed in diestrus and anestrus. It indicated that the CI was significantly high proportion in proestrus and estrus in comparison with the other phases. Plasma progesterone concentration was below 1.0ng/ml at the first day of vulval bleeding in pregnant and non-pregnat bitches, and then it was increaed slowly. When Day 0 was timed from the day that plasma progesterone concentration was first increased above 4.0ng/ml, plasma progesterone concentrations at Day 0 in pregnant and non-pregnant above 4.0 ng/ml, plasma progesterone concentrations at Day 0 in pregnant and non-pregnant bitches were $5.2{\pm}0.3ng/ml and 5.7{\pm}0.5ng/ml$$46.5{\pm}3.3 ng/ml$ in pregnant bitches and at Day 20 with $39.8{\pm}0.1ng/ml$ in nonpregnant bitches. It indicated that plasma progesterone concentration was higher in pregnant bitches than in non-pregnant bitches. Hereafter plasma progesterone concentration was decreased steadily. At Day 63 which is parturition day, plasma progesterone concentration was decreased below 1.0ng/ml with $0.8{\pm}0.2ng/ml$ in pregnant bitches whereas in the non-pregnant bitches at Day 75 were decreased below 1.0ng/ml with 40.5{\pm}0.4ng/ml$. Plasma progesterone concentrations was maintained below 1.0ng/ml during anestrus in all of them. The plasma estradiol-17 $\beta$ concentration was increased above 1.0 pg/ml at the first day of vulval bleeding and it showed a peak Day-1 with 38.2 pg/ml. Thereafter it was sharply decreased after Day 0, which was the day that plasma progesterone concentration was first increase above 4.0ng/ml, and was maintained below basal levels. In relationship between CI and reproductive hormones, plasma estradiol-17 $\beta$concentration showed a peak at Day-3 and CI showed a peak at Day-1 which was the second day after plasma estradiol-17 $\beta$ peak, and plasma progesterone concentration was first increased above 4.0ng/ml at Day 0 which was the first day after CI peak. CI was first increased above 80% at Day-6 which was the third day before plasma estradio-17 $\beta$ peak and it was maintained above 80% between Days-6 and Day 3 during 10 days, and showed above 90% at Day-3 which was the day that plasma estradiol-17 $\beta$peak and was maintained above 90% between Day-3 and Day 3 during 7 days. In conclusion, ovulation in Koran Jin-do bitches occurred at the first day after CI peak, at the third day after plasma estradiol-17 $\beta$peak and the day when plasma progesterone concentration was first increased above 4.0 ng/ml. And it was estimated that the optimal mating time was the day when the CI was maintained above 90% and plasma progesterone concentration was between 3.0~8.0ng/ml. Therefore plasma progesterone concentration measurement was used for determination of an accurate ovulation time and the optimal mating time but also vaginal cytology, which is low-priced with equipment and is the simple examination method, was reliable method for estimating estrous cycle, optimal breeding time and ovulation time in Korea Jin-do bitches.

  • PDF

Activity and Survival of the Natural Bacteria under the Stressed Conditions Detected by Bioluminescent Phenotype (스트레스 하의 자연세균의 활성 및 생존의 발광표현형을 이용한 탐지)

  • Park, Kyoung-Je;Yoon, Hye-Young;Chun, Se-Jin;Lee, Ho-Sa;Lee, Dong-Hun;Jahng, Deokjin;Lee, Kyu-Ho
    • Korean Journal of Microbiology
    • /
    • v.34 no.3
    • /
    • pp.154-161
    • /
    • 1998
  • To investigate whether the introduced genetic marker is useful to detect the survivalship and activity of the natural bacteria under the stressed conditions, one Gram-negative isolate, KP964 was transformed to the luminous phenotype by transferring luxAB gene. Under the starvation-stress this luminous bacterial culturability (determined by colony-forming-units [CFU] on agar plate) decreased rapidly below the detection limit by 37 days, while its total cell number (determined by AODC) remained almost the same as its initial inocular size. At that time period, the viable cell number was estimated to be 1400 times higher than its CFU number. The bioiuminescence (determined by relative light units [RLU]) produced under the same condition was also monitored and found to decrease more rapidly than the culturability by 5-fold. Under the other stresses, e.g., osmotic shocks, acid shock, and exposure to toxic chemicals, this bacterial strain did not show the reliable correlation between CFU and RLU. These results might not suggest the direct estimation of bioiuminescence from the stressed bacteria be an index of both the survivalship and its activity. However, when the stressed bacterial cells were incubated under the favorable condition by relieving from the existing stress, the potential bioiuminescence (the lag periods before the increase of bioiuminescence, the increase rates of bioiuminescence, and the maximal levels of bioiuminescence) was shown to be highly dependent upon the strengths of the stresses exposed to the bacterial cells. Therefore, analysis of the potential bioiuminescence from the stressed bacteria revealed good relationships with survival as well as activity.

  • PDF

Determination of shear wave velocity profiles in soil deposit from seismic piezo-cone penetration test (탄성파 피에조콘 관입 시험을 통한 국내 퇴적 지반의 전단파 속도 결정)

  • Sun Chung Guk;Jung Gyungja;Jung Jong Hong;Kim Hong-Jong;Cho Sung-Min
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.09a
    • /
    • pp.125-153
    • /
    • 2005
  • It has been widely known that the seismic piezo-cone penetration test (SCPTU) is one of the most useful techniques for investigating the geotechnical characteristics including dynamic soil properties. As the practical applications in Korea, SCPTU was carried out at two sites in Busan and four sites in Incheon, which are mainly composed of alluvial or marine soil deposits. From the SCPTU waveform data obtained from the testing sites, the first arrival times of shear waves were and the corresponding time differences with depth were determined using the cross-over method, and the shear wave velocity profiles (VS) were derived based on the refracted ray path method based on Snell's law and similar to the trend of cone tip resistance (qt) profiles. In Incheon area, the testing depths of SCPTU were deeper than those of conventional down-hole seismic tests. Moreover, for the application of the conventional CPTU to earthquake engineering practices, the correlations between VS and CPTU data were deduced based on the SCPTU results. For the empirical evaluation of VS for all soils together with clays and sands which are classified unambiguously in this study by the soil behavior type classification Index (IC), the authors suggested the VS-CPTU data correlations expressed as a function of four parameters, qt, fs, $\sigma$, v0 and Bq, determined by multiple statistical regression modeling. Despite the incompatible strain levels of the down-hole seismic test during SCPTU and the conventional CPTU, it is shown that the VS-CPTU data correlations for all soils clays and sands suggested in this study is applicable to the preliminary estimation of VS for the Korean deposits and is more reliable than the previous correlations proposed by other researchers.

  • PDF

On-site Output Survey and Feed Value Evaluation on Agro- industrial By-products (농산업부산물들에 대한 배출 현장 조사 및 사료적 가치 평가)

  • Kwak, W. S.;Yoon, J. S.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.2
    • /
    • pp.251-264
    • /
    • 2003
  • This study was conducted to make on-site survey on the output pattern and utilization situation of 19 by-products selected, to evaluate their nutritional characteristics, to find out a reliable index with which digestion of by-products can be predicted on the basis of chemical compositions analyzed and to diagnose the risk of using book values in the absence of the actual values analyzed for diet formulation. Production and utilization situations of by-products were quite various. Nutritionally, fruit processing by-products such as apple pomace (AP), pear pomace (PP), grape pomace (GP), and persimmon peel (PSP), and bakery by-products (BB) were classified as energy feeds. Soybean curd meal (SCM), animal by- products such as blood (BD), feather meal (FM) and poultry by-products (PB), and activated milk processing sludge (AMS) were classified as protein feeds. Soy hulls (SH), spent mushroom compost (SMC), barley malt hulls (BMH), waste paper (WP) and broiler litter (BL) were classified as roughage. Rumen contents (RC) and restaurant food waste (FW) were nutritionally analogous to complete diets for cattle and swine, respectively. Compared to soybean meal (SBM), BD and FM contained high (P<0.05) levels of amino acids and barley malt sprouts (BMS), AMS and FW contained low (P<0.05) levels of amino acids. Enzymatic (pepsin) digestibilities of proteinaceous feeds ranged between 99 and 66%. In vitro DM digestibility was high (P<0.05) in the order of FW, BB, AP, SH, PP, PSP, BMH, BMS, SCM, GP, RC, PB, BL, WP, SMC, AMS, FM and BD. In vitro DM digestibility had the highest correlation (r=0.68) with nonfibrous carbohydrate among chemical components. Differences between analyzed values of chemical components and book values were considerable. Caution is required in using book values when large amount of by-products are used in diets.

Associations between Sleep Quality, Daytime Sleepiness, with Perceived Errors during Nursing Work among Hospital Nurses (간호사의 수면의 질, 주간졸음 및 간호업무 중 인지한 오류 경험과의 관련성)

  • Kim, Mi Sung;Kim, Jang-Rak;Park, Ki-Soo;Kang, Young Sil;Choe, Sung Pil Michael
    • Journal of agricultural medicine and community health
    • /
    • v.38 no.4
    • /
    • pp.229-242
    • /
    • 2013
  • Objectives: The objective of this study was to identify the influence of shift work on sleep quality, daytime sleepiness, and perceived errors during nursing work among hospital nurses. Methods: The study subjects were 209 hospital nurses working in two general hospitals in South Korea. The data were collected through self-administered questionnaires in May 2013. Sleep quality was measured using Korea Pittsburgh Sleep Quality Index (PSQI-K), daytime sleepiness was measured using Epworth Sleepiness Scale (ESS), and perceived errors in past 6 months during nursing duty hours with the tool developed in this study. Results: The sleep quality was significantly worse among rotating shift nurses when compared to fixed day duty nurses. However, the odds ratio (OR) of 1.92 [95% confidence interval(CI): 0.58-6.37] adjusted for sociodemographic variables, health behaviors, and working environment in logistic regression was not significant. There was no significant difference in the daytime sleepiness between rotating shift nurses and fixed day duty nurses in both simple and multivariable analyses. There were significantly more perceived errors in rotating shift nurses than fixed day duty nurses. However, the OR of 1.26 (95% CI: 0.38-4.21) adjusted for sociodemographic variables, health behaviors, working environment, sleep quality, and daytime sleepiness in logistic regression was not significant. Depression (OR=3.31, 95% CI: 1.11-9.84) and daytime sleepiness(OR=1.18, 95% CI: 1.07-1.30) were significantly associated with perceived errors in logistic regression. Conclusion: This study suggested shift work among hospital nurses had no independent influence of sleep quality, daytime sleepiness, and perceived errors. However, daytime sleepiness had independent influence of perceived errors. More studies are warranted to achieve more reliable conclusion.