• Title/Summary/Keyword: reliability test conditions

Search Result 623, Processing Time 0.03 seconds

Investigation of the Acceleration Coefficient in Acceleration Models (가속모델의 가속계수 조사)

  • Hyunjong Park;Sungjun Kim;Beomsik Park;Somi Park;Siil Sung
    • Journal of Korean Society for Quality Management
    • /
    • v.52 no.1
    • /
    • pp.135-148
    • /
    • 2024
  • Purpose: This study is to investigate the literature on accelerated tests based on the acceleration model and to provide a compilation of results on the parameters applied in the acceleration model and the test conditions. Methods: This research is conducts a literature review on accelerated tests using the acceleration model, with a focus on test targets, test conditions, and parameter values. The study is organizing the results of this literature review to facilitate their application in the design of reliability tests. Results: A literature review investigated a variety of test targets, test conditions, and parameter values. Conclusion: The results of the literature research conducted revealed various acceleration model parameter. Such literature research on accelerated tests can establish the foundation for reliability test design and contribute to future product development and quality improvement

Accelerated Life Test and Reliability Growth Management Technique Within a Car Program (자동차 가속수명 시험과 신뢰성 성장관리 기술 개발)

  • Jung, Won
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.7 no.2
    • /
    • pp.33-39
    • /
    • 2002
  • Accelerated life testing of a car is used to get information quickly on its life distribution. Test cars are no under severe conditions and fail sooner than under usual conditions. A model is fitted to the accelerated failure times and then extrapolated to estimate the life distribution under usual conditions. This paper presents an accelerated test md the reliability growth theory, and applies it to some subsystems of cars during their prototype and pilot testing. The data presented illustrates explicitly the prediction of the reliability growth in the product development cycle. The application of these techniques is a part of the product assurance function that plays an important role in product reliability improvement.

  • PDF

Test-retest Reliability of Balance Tests in Older Adults (노인들에 대한 균형검사의 검사-재검사 신뢰도)

  • Kang, Soon-Hee
    • Journal of Korean Physical Therapy Science
    • /
    • v.16 no.4
    • /
    • pp.49-57
    • /
    • 2009
  • Background: The purpose of this study was to assess the test-retest reliability of balance measurements in older adults using balance measurement system(Good Balance). Methods: The subjects consisted of 49 female and 20 male in community-dwelling older adults. This study used a repeated-measure design. Each subject completed all the different tests once and they were then repeated with 2 minutes in between. Repeated two-ways analysis of variance(ANOVA), representing two test times and both sexes, was calculated for each of the two dependent variables. Intraclass correlation coefficients(ICCs) were used to assess the test-retest reliability. Results: 1) There was not significant difference between test and retest for mediolateral sway speed and anterioposterior sway speed under conditions of normal standing with eyes open, normal standing with eyes closed and semitandem standing with eyes open. There was not significant difference between males and females for mediolateral sway speed and anterioposterior sway speed under conditions of normal standing with eyes open, normal standing with eyes closed and semitandem standing with eyes open. There were not the interaction effects between genders and test time under three conditions. 2) The reproducibility between test and retest was excellent for anterioposterior sway speed(ICC=.77) under condition of normal standing with eyes open, and for mediolateral sway speed(ICC=.76) and anterioposterior sway speed(ICC=.84) under condition of semitandem standing with eyes open. The reproducibility between test and retest was fair to good for mediolateral sway speed(ICC=.64) under condition of normal standing with eyes open, for mediolateral sway speed(ICC=.63) and anterioposterior sway speed(ICC=.75) under condition of normal standing with eyes closed. Conclusion: Balance tests in older adults using balance measurement system(Good Balance) demonstrated acceptable levels of reliability.

  • PDF

Storage Reliability Assessment of Springs for Turbo Engine Components (터보엔진 구성품용 스프링의 저장 신뢰성 평가)

  • Chang, Mu-Seong;Lee, Choong-Sung;Park, Jong-Won;Kim, You-Il;Kim, Sun Je
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.4
    • /
    • pp.42-49
    • /
    • 2019
  • This paper presents a method to predict the storage reliability of springs for turbo engine components based on an accelerated degradation test. The reliability assessment procedure for springs is established to proceed with the accelerated degradation test. The spring constant is selected as the performance degradation characteristic, the temperature is determined to be the stress factor that deteriorates the spring constant. The storage tests are performed at three temperature test conditions. The spring constant is measured periodically to check the degradation status of the springs. Failure times of the springs are predicted by using the degradation model. Finally, the storage lifetime of the springs at normal use conditions is predicted using an accelerated model and failure times of all test conditions.

Reliability Assessment and Improvement of MEMS Vacuum Package with Accelerated Degradation Test (ADT) (가속열화시험을 적용한 MEMS 진공패키지의 신뢰성 분석 및 개선)

  • 최민석;김운배;정병길;좌성훈;송기무
    • Journal of Applied Reliability
    • /
    • v.3 no.2
    • /
    • pp.103-116
    • /
    • 2003
  • We carry out reliability tests and investigate the failure mechanisms. of the wafer level vacuum packaged MEMS gyroscope sensor using an accelerated degradation test. The accelerated degradation test (ADT) is used to evaluate reliability (and/or life) of the MEMS vacuum package and to select the accelerated test conditions, which reduce the reliability testing time. Using the failure distribution model and stress-life model, we are able to estimate the average life time of the vacuum package, which is well agreed with the measured data. After improving several package reliability issues such as prevention of gas diffusion through package, we carry out another set of accelerated tests at the chosen acceleration level. The results show that reliability of the vacuum packaged gyroscope has been greatly improved and can survive without degradation of performance, which is the Q-factor in gyroscope sensor, during environmental stress reliability tests.

  • PDF

Accelerated Life Test for 1.25Gbps Transceiver (광통신용 1.25Gbps Transceiver 가속수명시험)

  • Yun, Gwang-Su;Yu, Chong-Hee;Heo, Young-Soon
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1391-1393
    • /
    • 2008
  • In this paper, the long-term reliability for 1.25G transceiver in use of high speed optical access network is investigated. High temperature storage tests and accelerated life tests are used to long-term reliability. Accelerated aging test have been during 3,000 hour of the three accelerated aging conditions by caused high temperature stress. Mean life is assumed to follow the Arrhenius relationship and analysis from the failure data obtained in the accelerated aging conditions.

  • PDF

A Study on the Reliability Evaluation System for O-ring of Semiconductor Equipments (반도체장비용 오링의 종합 신뢰성 평가기술에 관한 연구)

  • 김동수;김광영;최병오;박화영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.613-617
    • /
    • 2001
  • The test items like as endurance, air leakage and oil endurance test is requested for reliability evaluation about O-ring which is a kind of core machinery accessories of semi-conduct manufacturing equipment. For verification of these, we design and manufactured a test system for endurance, air leakage and oil endurance of O-ring for semi-conduct manufacturing equipment, and also performed the test for two kinds of O-ring, as it were Viton and Kalretz. The characteristics of this test equipment consist in realization of the test conditions of semi-conduct manufacturing equipment and satisfying the test method. The test conditions are cut gas, vacuum grade, temperature and revolution numbers in the endurance test system, vacuum grade and temperature in the air leakage test system, temperature and time in the oil endurance test system. The separating test results for wearing which is an oil endurance test item, the wearing index of domestic produced Viton O-ring is higher than foreign product by 2%, wearing rate of Kalretz O-ring better than Viton O-ring by 17%, and particles existed in various place. The test result of air leakage which is measured through the RGA sensor used Helium, the vacuum grade was $10^-3$Torr. And the test result of oil endurance, the volume change rate was 7~15%. Hereafter, we intend to analysis the reliability test evaluation and to utilize for domestic manufacturing companies by establishing data base and developing reliability softwares.

  • PDF

Development of Life Test Specification for Catalytic Gas Sensor (접촉연소식 가스센서의 수명시험기준 개발)

  • Kang Jun-Ku;Park Jung-Won;Hwang Dong-Hoon;Ham Jung-Keol
    • Journal of Applied Reliability
    • /
    • v.6 no.1
    • /
    • pp.37-50
    • /
    • 2006
  • The accelerated life tests of the catalytic gas sensor were performed at three different gas concentration conditions. From the test data, the power-Weibull model was estimated and the acceleration factor between test condition 25%LEL(Lowe Explosive Limit) and use condition 5%LEL was about 3 according to this acceleration model. Using this acceleration factor, life test specification for qualifying that B10 lifetime of the catalytic gas sensor meets the goal lifetime (5 years) was designed.

  • PDF

Implementation of PXIe platform based portable Automatic Test Equipment to improve reliability

  • Gwon, Hyeok-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.7
    • /
    • pp.9-16
    • /
    • 2017
  • In this paper, we propose a development method of portable Automatic Test Equipment based on PXIe platform. Legacy VME form factor structured test equipment has limited reuse and expansion of modules due to unapplied bus specification. In particular, these limitations can cause development periods and costs to increase, and the reliability of environmental conditions is lacking due to non-standard modules. The test equipment of the proposed PXIe platform can use diverse COTS modules to shorten the development period and minimize the instability between developments. The PXIe development module works with standard Xilinx FPGAs, PXIe Windows device drivers, and applications on standard PXIe buses. The use of standard bus and COTS modules increases scalability and reusability, enabling rapid development and excellent maintenance. Through the test, we show the proposed test equipments can be implemented efficiently between the development processes and proved their reliability through function tests and environmental tests.

Study on Reliability Assessment for the Medical Device Software from the Viewpoint of Functional Safety (기능 안전 관점에서의 의료기기 소프트웨어 신뢰성 평가 방법에 관한 연구)

  • Kim, Sung Min;Ko, Byeonggak;Do, Gyeong-Hun;Kim, Hye Jin;Ham, Jung-Keol
    • Journal of Applied Reliability
    • /
    • v.16 no.3
    • /
    • pp.216-223
    • /
    • 2016
  • Purpose: This paper suggests the procedure to enhance the reliability of the software of the medical device that is to cure, treat, diagnose, and prevent a disease or an abnormal health conditions. Methods: After test requirements are classified by the software requirements specification for safety and backgrounds, reliability assessment methods are suggested. Results: Verification and validation for function and safety can be performed whether the medical device software are implemented as intended. Conclusion: Procedure on the static analysis, unit test, integration test, and system test are provided for the medical device software.