• Title/Summary/Keyword: reliability and safety

Search Result 3,067, Processing Time 0.031 seconds

Thickness evaluation of Cr coating fuel rod using encircling ECT sensor

  • Park, Jeong Won;Ha, Jong Moon;Seung, Hong Min;Jang, Hun;Choi, Wonjae
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3272-3282
    • /
    • 2022
  • To improve the safety and life extension qualities of nuclear fuel rods which is currently made of zirconium (Zr) alloy, research on the application of chromium (Cr) coating was conducted. Cr coating has advantages such as increased corrosion resistance and reduced oxidation rate, but non-destructive thickness evaluation studies are needed to ensure the reliability of the steps taken to provide uniform coating thickness. Eddy current testing (ECT) is a representative non-destructive technique for such as thickness evaluation and surface defect inspection. To inspect changes in thickness at micron scale, the Swept Frequency Eddy Current Testing (SFECT) method was applied to select a frequency range sensitive to changes in thickness. The coating thickness was evaluated using changes in signals, such as that for impedance. In this study, basic research was performed to evaluate the thickness of the Cr coating on a rod using an encircling sensor and the SFECT technique. The sensor design parameters were determined through simulation, after which the new sensor was manufactured. A sensor capable of measuring the thickness of a non-uniformly Cr-coating rod was selected through an experiment evaluating the performance of the manufactured sensor. This was done using the impedance-difference of a Cr-coating rod and a Zr alloy rod. The possibility of evaluation of the Cr coating thickness was confirmed by comparing the experimental results with the selected sensor and the signals of the measured Cr-coating rod. All simulation results were verified experimentally.

Real-Time PCR for Quantitative Detection of Bovine Parvovirus during Manufacture of Biologics (생물의약품 제조공정에서 Bovine Parvovirus 정량 검출을 위한 Real-Time PCR)

  • Lee, Dong-Hyuck;Lee, Jung-Hee;Kim, Chan-Kyong;Kim, Tae-Eun;Bae, Jung-Eun;Kim, In-Seop
    • Microbiology and Biotechnology Letters
    • /
    • v.36 no.3
    • /
    • pp.173-181
    • /
    • 2008
  • Bovine blood, cell, tissue, and organ are used as raw materials for manufacturing biologics such as biopharmaceuticals, tissue-engineered products, and cell therapy. Manufacturing processes for the biologics have the risk of viral contamination. Therefore viral validation is essential in ensuring the safety of the products. Bovine parvovirus (BPV) is one of the common bovine pathogens and has widely been known as a possible contaminant of biologics. In order to establish the validation system for the BPV safety of biologics, a real-time PCR method was developed for quantitative detection of BPV contamination in raw materials, manufacturing processes, and final products. Specific primers for amplification of BPV DNA were selected, and BPV DNA was quantified by use of SYBR Green 1. The sensitivity of the assay was calculated to be $1.3{\times}10^{-1}\;TCID_{50}/mL$. The real-time PCR method was validated to be reproducible and very specific to BPV. The established real-time PCR assay was successfully applied to the validation of Chinese hamster ovary (CHO) cell artificially infected with BPV. BPV DNA could be quantified in CHO cell as well as culture supernatant. Also the real-time PCR assay could detect $1.3{\times}10^0\;TCID_{50}/mL$ of BPV artificially contaminated in bovine collagen. The overall results indicated that this rapid, specific, sensitive, and robust assay can be reliably used for quantitative detection of BPV contamination during manufacture of biologics.

On the Criteria of Reliability Design for the Steel Plate (강판(鋼板)의 신뢰성(信賴性) 설계기준(設計基準))

  • Oh, Chang Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.4
    • /
    • pp.25-36
    • /
    • 1984
  • This paper checked up the safety criteria of the steel structural members by LRFD. And it calculated the resistance and load modulus for it by the proposed method, considering our circumstance, by establisting the taget relability index (${\beta}_0$), and compared their calculated modulus with the nominal safety factors of the road-bridge code and analyzed them. Uncertain quantity measurements fnr the resistance of the steel structural members and for the load effect are due to the method of the uncertain quantity analysis of the load and the resistance, of Galambos-Ravindra and SGST. The summary of the results is as follows: 1) Considering our circumstance, taget relibility index(${\beta}_0$) for current steel structural members are appropriate ${\beta}_0=3.5$. 2) Nominal resistance ${\Phi}^{\prime}$ of the strength design formula for 1) and nominal load modulus ${\gamma}_i^{\prime}$ are as follows; a) Both-sides support plate: ${\Phi}{^{\prime}}=0.75$, ${\gamma}_0{^{\prime}}=1.04$, ${\gamma}_L{^{\prime}}=2.08$ b) One-side support plate: ${\Phi}{^{\prime}}=0.82$, ${\gamma}_0{^{\prime}}=1.04$, ${\gamma}_L{^{\prime}}=2.11$.

  • PDF

A Study on the Assessment of Source-term for PWR Primary System Using MonteCarlo Code (MonteCarlo 코드를 이용한 PWR 일차 계통 선원항 평가에 관한 연구)

  • Song, Jong Soon;Lee, Sang Heon;Shin, Seung Su
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.3
    • /
    • pp.331-337
    • /
    • 2018
  • The decommissioning of nuclear power plants is generally executed in five steps, including preparation, decontamination, cutting/demolition, waste disposal and environmental restoration. So, for efficient decommissioning of nuclear power plants, worker safety, effects compared to cost, minimization of waste, possibility of reuse, etc., shall be considered. Worker safety and measurement technology shall be secured to exert optimal efficiency of nuclear power plant decommissioning work, for which accurate measurement technology for systems and devices is necessary. Typical In-Situ methods for decommissioning of nuclear plants are CZT, Gamma Camera and ISOCS. This study used ISOCS, which can be applied during the decommissioning of a nuclear power plant site without collecting representative samples, to take measurements of the S/G Water Chamber. To validate the measurement values, Microshield and the GEANT4 code was used as the actual method were used for modeling, respectively. The comparison showed a difference of $1.0{\times}10^1Bq$, which indicates that it will be possible to reduce errors due to the influence of radiation in the natural environment and the precision of modeling. Based on the research results of this paper, accuracy and reliability of measurement values will be analyzed and the applicability of the direct measurement method during the decommissioning of NPPs will be assessed.

Comparative Study on the Characteristics of Microalgae as Standard Species for Marine Ecotoxicity Tests (Skeletonema sp., Dunaliella tertiolecta) (해양생태독성시험 표준생물로서 미세조류의 특성 비교 연구(Skeletonema sp., Dunaliella tertiolecta))

  • Kim, Tae Won;Moon, Chang Ho;Lee, Su Jin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.5
    • /
    • pp.514-522
    • /
    • 2020
  • To understand the ecotoxicological differences between representative Skeletonema sp. and Dunaliella tertiolecta, both producers as international standard test species for marine ecotoxicity testing, we compared each standard test method, and comparatively analyzed the suitability of the species for environmental assessment and their sensitivity to various test substances. Although most of the test conditions were the same in each method, there were differences in limitation of pH changing and the initial inoculation density in the validation criteria, which is supposed to originate from the low growth rate of D. tertiolecta. In terms of suitability, both species showed consistency in test performance by repeatedly meeting the validation criteria required by the standard test methods. The salinity ranges available for testing were 20 and 10 psu for Skeletonema sp. and D. tertioelecta, respectively. Finally, regarding sensitivity, the toxicity sensitivity of Skeletonema sp. was relatively higher than that of D. tertiolecta for the reference toxicant, actual polluted water discharged (ballast water), and other chemicals. This implies that using at least two species of microalgae from different classification groups could help increase the reliability and objectivity of test results in the performance of marine ecotoxicity tests using producers.

Measurement of the Device Properties of Fixed Temperature Heat Detectors for the Fire Modeling (화재모델링을 위한 정온식 열감지기의 장치물성 측정)

  • Park, Hee-Won;Cho, Jae-Ho;Mun, Sun-Yeo;Park, Chung-Hwa;Hwang, Cheol-Hong;Kim, Sung-Chan;Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.37-43
    • /
    • 2014
  • The high predictive performance of fire detector models is essentially needed to assure the reliability of fire and evacuation modeling in the process of Performance-Based fire safety Design (PBD). The main objective of the present study is to measure input information in order to predictive the accurate activation time of fixed temperature heat detectors adopted in Fire Dynamics Simulator (FDS) as a representative fire model. To end this, Fire Detector Evaluator (FDE) which could be measured the device properties of detector was used, and the spot-type fixed temperature heat detectors of two thermistor types and one bimetal type were considered as research objectors. Activation temperature and Response Time Index (RTI) of detectors required for the fire modeling were measured, and then the RTI was measured for ceiling jet flow and vertical jet flow in consideration of the install location of detectors. The results of fire modeling using measured device properties were compared and validated with the experimental results of full-scale compartment fires. It was confirmed that, in result, the numerically predicted activation time of detector showed reasonable agreement with the measured activation time.

Antifouling Effect of an Ultrasonic System Operating at Different Frequencies (주파수 변동에 따른 초음파방오장비의 파울링제거효과)

  • Bae, Jin-Woo;Park, Guan-Sik;Ru, Myung-Lok;Park, Goun-Ha
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.5
    • /
    • pp.609-616
    • /
    • 2019
  • When the fouling of a vessel occurs, its resistance at sea increases and there is a corresponding increase in fuel consumption. The maintenance cost of the vessel also increases because it is time-consuming to remove the fouling. To solve this problem and minimize environmental contamination of sea-water, there have been recent developments in anti-fouling paints as self-polishing copolymers that not include toxic elements such as tin. When these conventional techniques are applied to vessels, polishing is promoted during the operation whereby friction or vibration with seawater occurs. This leads to enhanced anti-fouling performance. However, when fouling is intensified such as during an anchorage, there is no flow of seawater and polishing is suppressed. This leads to a deterioration of the performance of anti-fouling. To solve these problems, we developed a system that induces vibration in a vessel during anchorage. As such, the deterioration of polishing due to insuf icient flow of seawater is inhibited. The reliability of the ultrasonic antifouling system was evaluated by calculating its repeatability. The removal efficiency of fouling of the proposed system was qualitatively evaluated using test specimens. The test revealed that the value of the coefficient of variation for the reproducibility of the frequency and amplitude was 0.2 % and 4.0 % on average. The degree of fouling of the specimens was the highest at 73.3 g in the No.5 sepcimen. Moreover, efficiency of fouling removal was 93.2 % on average compared to the specimens without the proposed system.

A Security Nonce Generation Algorithm Scheme Research for Improving Data Reliability and Anomaly Pattern Detection of Smart City Platform Data Management (스마트시티 플랫폼 데이터 운영의 이상패턴 탐지 및 데이터 신뢰성 향상을 위한 보안 난수 생성 알고리즘 방안 연구)

  • Lee, Jaekwan;Shin, Jinho;Joo, Yongjae;Noh, Jaekoo;Kim, Jae Do;Kim, Yongjoon;Jung, Namjoon
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.2
    • /
    • pp.75-80
    • /
    • 2018
  • The smart city is developing an energy system efficiently through a common management of the city resource for the growth and a low carbon social. However, the smart city doesn't counter a verification effectively about a anomaly pattern detection when existing security technology (authentication, integrity, confidentiality) is used by fixed security key and key deodorization according to generated big data. This paper is proposed the "security nonce generation based on security nonce generation" for anomaly pattern detection of the adversary and a safety of the key is high through the key generation of the KDC (Key Distribution Center; KDC) for improvement. The proposed scheme distributes the generated security nonce and authentication keys to each facilities system by the KDC. This proposed scheme can be enhanced to the security by doing the external pattern detection and changed new security key through distributed security nonce with keys. Therefore, this paper can do improving the security and a responsibility of the smart city platform management data through the anomaly pattern detection and the safety of the keys.

Reliability improvement methods of AF track circuits for the train control system (열차내 연산시스템용 AF궤도회로 신뢰성향상 방안 연구)

  • Park, Jae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.10
    • /
    • pp.4762-4767
    • /
    • 2012
  • The AF track circuit that detecting train position and transmitting various train control data for DTG to the train on-board is composed of single operation system. If a failure occurs on this system, the driver should be operate the train by manually until the system is restored, because the system cannot control switch machines and signals by automatically. In this process the human error affects to the train delay, collision, derailment and critical safety accident. Therefore, this document has analyzed the effects that each failure mode influences on system and train, and quantified the failure valuation point and class. Basis on this quantified analysis result, MTBF increased and MTTR decreased and failure number also decreased by adopting the independent installation of power supply, the replacement of defected capacitors, the installation of resister cooling system and the improvement of maintenance methods. And the failure factors of AF track circuits were decreased by conducting the preventive maintenance which is a quantitative way of maintenance system by experience.

A Study of Usefulness of Fine Needle Aspiration Cytology of the Thyroid Lesions (갑상선 병변의 세침흡인 세포검사의 유용성에 관한 연구)

  • Kwon, Kye-Hyun;Jin, So-Young;Lee, Dong-Wha
    • The Korean Journal of Cytopathology
    • /
    • v.7 no.2
    • /
    • pp.111-121
    • /
    • 1996
  • Fine needle aspiration cytology(FNAC) is preferred because of simplicity, safety, and reliability in the evaluation of patients with thyroid nodule or hyperplasia. However, there are a few limitations such as false-negative or false-positive cases and non-diagnostic material. To evaluate the usefulness of FNAC in thyroid lesions, we reviewed 704 FNAC cases of thyroid nodules from 1988 to 1994 at Soonchunhyang University Hospital. The results are as follows. 1. Among 704 FNAC cases of thyroid gland, 571(81.1%) cases were benign, 12(1.7%) were suspicious, 71(10.1%) were malignancy, and 50(7.1%) were material insufficiency. The cytologic diagnoses of the benign lesions included 168 cases of follicular neoplasm, 139 cases of adenomatous goiter, 162 cases of follicular lesion such as follicular neoplasm or adenomatous goiter, 61 cases of Hashimoto's thyroiditis, 13 cases of subacute thyroiditis, and 28 cases of colloidal nodule or benign nodule. The malignant lesions included 68 cases of papillary carcinona, two medullary carcinomas and a case of metastatic colon cancer. 2. The average number of cytologic smear slides was $4.12{\pm}1.81$ in material insufficiency and $5.63{\pm}1.79$ in diagnostic cases. This difference was statistically significant(p<0.00001). 3. Histological assessment of 150 cases revealed 2 false negative and 1 false positive cases. The false negative cases were a case of marked sclerosis in papillary carcinoma and an occult case of papillary carcinoma. The false positive case resulted from pseudo-ground glass nuclei due to marked dry artifact. 4. Comparison between the FNAC and the histologic diagnosis revealed that FNAC had a sensitivity of 93.5%, a specificity of 99.2%, a false negative rate of 6.6%, a false positive rate of 0.8%, and an overall diagnostic accuracy of 98.0%. Therefore, FNAC of thyroid gland is a very reliable diagnostic method with excellent accuracy rate.

  • PDF