• Title/Summary/Keyword: release height

Search Result 168, Processing Time 0.022 seconds

Comparison of the Flame Height of Pool Fire according to Combustion Models in the FDS (FDS의 연소모델에 따른 풀화재의 화염높이 비교)

  • Han, Ho-Sik;Hwang, Cheol-Hong;Oh, Chang Bo;Choi, Dongwon;Lee, Sangkyu
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.42-50
    • /
    • 2018
  • The effect of sub-grid turbulence and combustion models on the mean flame height in a heptane pool fire according to the Fire Dynamics Simulator (FDS) version (5 and 6) based on Large Eddy Simulation (LES) was examined. The heat release rate for the fire simulation was provided through experiments performed under identical conditions and the predictive performance of the mean flame height according to FDS version was evaluated by a comparison with the existing correlation. As a result, the Smagorinsky and Deardorff turbulence models applied to FDS 5 and 6, respectively, had no significant effects on the mean flow field, flame shape and flame height. On the other hand, the difference in pool fire characteristics including the mean flame height was due mainly to the difference in the mixture fraction and Eddy Dissipation Concept (EDC) combustion models applied to FDS 5 and 6, respectively. Finally, compared to FDS 6, FDS 5 provided the predictive result of a significantly longer flame height and more consistent mean flame height than the existing correlation.

Effects of Slow-Release Nitrogen Fertilizers, Latex Coated Urea and Meister10, on Direct Seeded Rice in Dry Soil (벼 건답직파재배시 완효성질소비료의 시용 효과)

  • Back, Jun-Ho;Jang, Myung-Hwan;Lee, Seung-Ho;Lee, Sang-Jo;Lim, Jun-Young;Kim, Bok-Jin
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.34 no.6
    • /
    • pp.407-412
    • /
    • 2001
  • This study was conducted to find out the effect of slow-release nitrogen fertilizer, such as latex coated urea(LCU) and Meister10(MS10) on direct seeded rice in dry soil(DS). Junghwabyeo, and early maturity rice cultivar was grown on the plots which were treated with None-nitrogen. urea. LCU and MS10 plot. Growth characteristic, yield and yield components were investigated. Nitrogen uptake-efficiency and physico-chemical properties of soil before-after experiment were analyzed. Plant height and number of tillers $m^{-2}$ in LCU and MS10 plot at early grow stages were higher than those in urea plot. Plant height and number of tillers $m^{-2}$ grown on the plot of Ms10 plot were higher than those of LCU plot. The number of seedling $m^{-2}$ were no significant differences among None-N, urea, and MS10 plot in DS. Heading date and leaf color were higher with Urea than LCU and MS10 plot. Culm length in LCU and MS10 plot were longer compared with urea plot, but panicle length was similar among with Urea, LCU and MS10 plot. Number of panicles $m^{-2}$ was greater in order of MS10 > LCU > Urea plot. Yield were greater in order of MS10 > LCU > Urea plot. Nitrogen uptake and nitrogen efficiency were greater in order of MS10 > LCU > urea plot. After the experiment, total content of nitrogen in soil was not changed at all treatments, but pH, P and Si of soil were lower than those of before experiment at all treatments.

  • PDF

Effects of Slow-Release Nitrogen Fertilizers, Latex coated urea and Meister 10, on Direct Seeded Rice in Flood Soil (벼 담수직파재배시 완효성질소비료의 시용 효과)

  • Jang, Myung-Hwan;Back, Jun-Ho;Lee, Seung-Ho;Lee, Sang-Jo;Lim, Jun-Young;Kim, Bok-Jin
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.34 no.6
    • /
    • pp.401-406
    • /
    • 2001
  • This study was conducted to find out the effect of slow-release nitrogen fertilizer, such as latex coated urea(LCU) and Meister10(MS10) on direct seeded rice in flooded soil(FS). Junghwabyeo, and early maturity rice cultivar grown on the plots which were treated with None-nitrogen, urea, LCU and MS10 plot. Growth characteristic, yield and yield components were investigated. Nitrogen uptake-efficiency and physico-chemical properties of soil before-after experiment were analyzed. Plant height and number of tillers $m^{-2}$ in LCU and MS10 plot at early grow stages were higher than those of Urea plot. MS10 and LCU plot showed similar tendency on the plant height but MS10 plot was higher than LCU plot on the number of tillers $m^{-2}$. The number of seedling $m^{-2}$ were no significant differences among None-N, urea, and MS10 plot. Heading date and leaf color were no significant differences among None-N, urea, and MS10 plot. Culm length in LCU and Ms10 plot were longer compared with urea plot, but panicle length were similar among with Urea, LCU and MS10 plot. Number of panicles $m^{-2}$ was highest in MS10 plot and it was similar between LCU and Urea plot. Yield were greater in order of Ms10 > LCU > Urea plot. Nitrogen uptake and nitrogen efficiency were greater in order of MS10 > LCU > urea plot. After the experiment, total content of nitrogen in soil was not changed at all treatments, but pH, P and K of soil were lower than that of before experiment at all treatments.

  • PDF

Atmospheric CO2 Uptake by Pinus densiflora and Quercus mongolica

  • Jo, Hyun-Kil;Ahn, Tae-Won
    • Journal of Environmental Science International
    • /
    • v.12 no.8
    • /
    • pp.853-860
    • /
    • 2003
  • Plants sequester atmospheric CO$_2$, a major agent of climate change, during the growing periods and mitigate its rising accumulation in the atmosphere. Pinus densiflora and Quercus mongolica are the native tree species dominant in the temperate forests of Korea. This study quantified the annual CO$_2$ uptake by the two species at forest sites in Chuncheon in the middle of the country. The quantification was based on seasonal measurements of CO$_2$ exchange rates under natural conditions by an infrared gas analyzer over the growing season (1999). The monthly CO$_2$ uptake per unit leaf area ranged from 1.6-6.7 mg/d㎡/h for P. densiflora and from 3.7-8.9 mg/d㎡/h for Q. mongolica, with a maximum in mid-summer. An equation for each species was generated to estimate easily the annual CO$_2$ uptake by total leaf area per tree, which subtracted the CO$_2$ release (i.e. respiration) by leaves and woody organs from the gross CO$_2$ uptake (diurnal uptake and release by leaves). Annual CO$_2$ release by leaves and woody organs accounted for 58-73% of the gross CO$_2$ uptake across tree specimens. Annual CO$_2$ uptake per tree increased with increasing dbh (stem diameter at breast height) for the study diameter range, and was greater for Q. mongolica than for P. densiflora in the same dbh sizes. This was mainly associated with a greater total leaf area in the former. For example, the annual CO$_2$ uptake by one tree with dbh of 25 cm was 35.6 kg/yr for P. densiflora and 47.9 kg/yr for Q. mongolica. The results from this study can be applied to evaluate an atmospheric CO$_2$ reduction of woody plants by forest type and age class.

Analysis on the Effects of the Heat Loss Coefficient on the Operation Time of Sprinkler in Compartment Fire (구획 화재에서 스프링클러 열 손실계수 변화에 따른 작동 시간 분석)

  • You, Woo Jun
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.34-39
    • /
    • 2018
  • In this study, the experiment conditions for the variation of heat release rate in compartment space were constructed to analyze the effects of fire spread and the operation time of sprinkler in accordance with the heat loss of the sprinkler's heat element. The compartment composed of fire board (width = 0.3 m, height = 0.5 m, length = 3.0 m), are manufactured to measure the temperature distributions in the inner space, the mass loss rate and heat release rate during the experiment of N-heptane pool fire test. Also, the operation time of sprinkler is analyzed with the installation of sprinkler and C-factor using Fire Dynamics Simulator Ver.6 under the experiment conditions. The results show that the operation time of sprinkler, which has RTI $100(m{\cdot}s)^{0.5}$ operating temperature $70^{\circ}C$, is 30 s~60 s for C-factor = 0 and 1, 62 s~92 s for C-factor = 3, and 120 s over for C-factor = 5, respectively.

Motion Analysis of Kolman Technique by Korean Top Gymnasts on Horizontal Bar (국내 우수선수들의 철봉 Kolman 기술 동작 분석)

  • Lim, Kyu-Chan;Lee, Nam-Koo
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.4
    • /
    • pp.283-289
    • /
    • 2021
  • Objective: The aim of this study was to analyze the pattern of Kolman technique by five Korean top gymnasts including the three national athletes on horizontal bar. Method: Two digital high-speed camcorders were used with 90 frames/sec and their Kolman motions were filmed in sports science secondary school gymnasium at U city. After the kinematic and kinetic variables were carried out by Kwon3D 3.1 motion package during the whole phase, the optimized release motion was investigated by simulating the body COG path during the aerial phase. Results: Firstly, it was revealed that the average changes of hip, shoulder joint angle were 84 deg, 53 deg respectively during the functional sub-phase and the average swing phaseal time was 1.21 s. Secondly, it was revealed that the average body COG positions and velocities (Y, Z) at release were -0.65 m, 0.48 m, 1.65 m/s, 3.97 m/s respectively and the average release angle, peak height and flight time were 67 deg, 1.29 m, 0.79 s respectively. Thirdly, it was revealed that the directions of somersault of whole and lower body, tilt of lower body were counterclockwise, whereas the directions of tilt of whole body, twist of whole and lower body were clockwise at the ready for re-grasp. Lastly, it was revealed that the body COG paths were different from each other during the aerial phase followed by the different body COG velocities. Conclusion: Korean gymnasts of this study controlled their motions well in terms of the timing of hip·shoulder joint, body position, body angular momentum especially during the functional sub-phase, but their motions were different during the aerial phase. Nonetheless most of them made the adequate body position at the instant of re-grasp. It would be suggested that Korean gymnasts except S3 should increase the vertical velocity.

Fracture analysis of functionally graded beams with considering material non-linearity

  • Rizov, Victor I.
    • Structural Engineering and Mechanics
    • /
    • v.64 no.4
    • /
    • pp.487-494
    • /
    • 2017
  • The present paper deals with a theoretical study of delamination fracture in the Crack Lap Shear (CLS) functionally graded beam configuration. The basic purpose is to analyze the fracture with taking into account the material non-linearity. The mechanical behavior of CLS was described by using a non-linear stress-strain relation. It was assumed that the material is functionally graded along the beam height. The fracture was analyzed by applying the J-integral approach. The curvature and neutral axis coordinate of CLS beam were derived in order to solve analytically the J-integral. The non-linear solution of J-integral obtained was verified by analyzing the strain energy release rate with considering material non-linearity. The effects of material gradient, crack location along the beam height and material non-linearity on fracture behavior were evaluated. The J-integral non-linear solution derived is very suitable for parametric studies of longitudinal fracture in the CLS beam. The results obtained can be used to optimize the functionally graded beam structure with respect to the fracture performance. The analytical approach developed in the present paper contributes for the understanding of delamination fracture in functionally graded beams exhibiting material non-linearity.

Differential temperature fire detector analysis of comparative study based on sensor installation (차동식 열감지기 설치기준 비교분석에 관한 연구)

  • Hwang, Dong-Hwan;Yang, Kwang Mo;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.379-389
    • /
    • 2014
  • Fire detectors are designed to minimize loss of life from a fire alarm system as an alarm to help evacuate more quickly until the completion of the evacuation alarm should be continued. the purpose of such alarms in order to achieve the characteristic fire heat release rate reaches a certain level, or when a certain time has elapsed, when the heat detector is to be alarms to answer. Requires a quick response, it is desirable to install the sensor as much as possible, but taking into account the cost of installation problems by engineering approach to minimize the quantity and rapidity of detection capability should be increased. In order to increase the rapidity of fire detectors in a room according to the height of the sensing period is to be maintained the optimum distance of the fire detector detects characteristics should be considered. Differential spot-type heat detectors installed domestic basis, depending on the type of sensor that can detect one sensor area is limited and less than 4m ceiling height regulations and simply double the number in excess of 4m and intended to be installed.

Numerical study to reproduce a real cable tray fire event in a nuclear power plant

  • Jaiho Lee ;Byeongjun Kim;Yong Hun Jung;Sangkyu Lee;Weon Gyu Shin
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1571-1584
    • /
    • 2023
  • In this study, a numerical analysis was performed as part of an international joint research project to reproduce a real cable tray fire that occurred in the heater bay area of the turbine building of a nuclear power plant. A sensitivity analysis was performed on various input parameters to derive results consistent with the sprinkler activation time obtained from the fire event analysis. For all sensitive parameters, the normalized sprinkler activation time correlated well with the power function of the normalized sprinkler height. A correlation equation was developed to identify the sprinkler activation time at any location when determining the slope or fire growth rate under the conditions assuming a linear or t-squared heat release rate (HRR) time curve. Various cable fire growth assumptions were used to determine which assumption was better to provide the prediction coincident with the information given from the fire event analysis in terms of the sprinkler activation time and total energy generated from cables damaged by fire. In the comprehensive analysis of all the sensitive parameters, the standard deviation of the input parameters increased as the sprinkler height decreased. Within the range of the sensitivity parameter values given in this study, when considering all sprinkler heights, the standard deviation of the cable model change was the largest and that of the overhang position change was the smallest.

Effects of Botulinum Toxin Type A Injection into Masseter Muscle on the Jaw Growth in Rats (교근부 보툴리눔 A형 독소(Botulinum Toxin Type A) 주사가 쥐의 턱뼈 성장에 미치는 영향)

  • Yoon, Seung-Hyun;Kim, Ji-Yeon;Kim, Seong-Taek
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.2
    • /
    • pp.171-178
    • /
    • 2007
  • Botulinum toxin type A (BTX-A) has a local effect at the neuromuscular junction by blocking acetylcholine release and thus causing paralysis and atrophy of the affected muscles. In dentistry, Botulinum toxin type A(BTX-A) is used for the treatment of masseteric hypertrophy, temporomandibular disorder, and severe bruxism related neurologic disorder. We hypothesized that the muscle atrophy after BTX-A injection into masseter muscle in growing rats, could affect the jaw growth. The purpose of this study was to determine the effects of the BTX-A injected into the masseter muscle on the jaw growth in rats. Rats were divided into four groups(group 1; control group, group 2; saline injection group, group 3; BTX-A injection group, group 4; baseline control group). Group 4 was sacrificed at the beginning of the experiment to provide baseline values of jaw measurements. The weight, length and width of jaw in those groups were measured every weeks. This study reported that the mandibular body length, condylar length, coronoid process length, anterior region height, coronoid process height and condylar height of the jaw in BTX-A injection group were shorter than those of the control and saline injection groups(P<0.05). In conclusion, BTX-A injected into the masseter muscle may affect the undergrowth of the jaw in rats.