• Title/Summary/Keyword: release flux

Search Result 162, Processing Time 0.021 seconds

A Study on Ignitability and Heat Release Rate Characteristics of Rigid Polyurethane Foam (경질 폴리우레탄폼의 착화성 및 열방출특성 연구)

  • 공영건;이두형
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.117-123
    • /
    • 2003
  • In this study; the ignition and heat release rate characteristics of rigid polyurethane foam were investigated in accordance with setchkin ignition tester and cone calorimeter which is using oxygen consumption principle. In the ignition temperature study; flash-ignition temperature was $383^{\circ}C$-$390^{\circ}C$, self-ignition temperature was$ 493^{\circ}C$∼495$^{\circ}C$. The self-ignition temperature of rigid polyurethane foam was about $100^{\circ}C$ higher than the flash-ignition temperature. In the cone calorimeter study, the time to ignition of rigid polyurethane foam was faster as the external heat flux increase. In the same heat flux level, the time to ignition was faster as the density of rigid polyurethane foam decrease. Also the heat release rate was the largest value at the heat flux of /$50 ㎾\m^2$ and had a tendency of increase as the heat flux level and density increase. In the standpoint of time to ignition and heat release rate, the fire performance of rigid polyurethane foam was influenced by the applied heat flux level and density and the flashover propensity classified by Petrella's proposal was high.

Thermal Characteristics of Living Leaves in Pinus Densiflora with Heat Flux (복사열 증가에 따른 소나무 생엽의 열적특성 분석)

  • Park, Young-Ju;Lee, Hae-Pyeong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.5
    • /
    • pp.75-82
    • /
    • 2010
  • To study the combustion characteristics of forest fuel by fire intensity, the experiment of combustion characteristics on Pinus Densiflora living leaves, which is the weakest species to the forest fire, was delivered, using variables of heat flux(25 kW/$m^2$, 50 kW/$m^2$, 75 kW/$m^2$). With the equipment of Cone calorimeter, the characteristics of ignition, heat, smoke release, CO and $CO_2$ release, and mass loss were analyzed. Pinus Densiflora living leaves containing moisture of 60.66% were not ignited at the heat flux of variables 25 kW/$m^2$, 50 kW/$m^2$, 75 kW/$m^2$. In proportion to the heat flux value, heat release amount and heat release rate reached maximum value rapidly: higher variables came to the maximum by the half rapidity and the maximum value were twice higher than the former lower variables respectively. As for the smoke release, the less heat flux the variable had, the more smoke release it had, due to incomplete combustion. The release amount of CO and $CO_2$ had more maximum value as the heat flux increased and more radiant heat meaned more carbon oxide. When the forest fire breaks out, therefore, a great amount of CO and $CO_2$ will be released by Pinus Densiflora.

APPLICATIONS OF A MODEL TO COMPARE AFLAME SPREAD AND BEAT RELEASE PROPERTIES OF INFERIOR FINISH MATERIALS IN A COMPARTMENT

  • Kim, Woon-Hyung;James G. Quintiere
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.193-200
    • /
    • 1997
  • Flame spread and heat release properties and incident heat flux of interior materials subject to an igniter heat flux in a compartment are investigated and compared by using computer model. A comer fire ignition source is maintained for 10 minutes at 100 kw and subsequently increased to 300kw. In executing the model, base-line material properties are selected and one is changed for each run. Also 4 different igniter heat flux conditions and examined. Results are compared for the 12 different materials tested by the ISO Room Comer Test (9705). The time for total energy release rate to reach 1MW is examined. The parameters considered include flame heat flux and thermal inertia, lateral flame spread parameter, heat of combustion and effective heat of gasfication. The model can show the importance of each property in causing fire growth on interior Hnish materials in a compartment. The effect of ignitor heat flux and material property effects were demonstrated by using dimensionless parameters a, b and Tb. Results show that for b greater than about zero, flashover time in the ISO Room-Corner test is principally proportional to ignition time and nothing more.

  • PDF

In Vitro Percutaneous Absorption of Ondansetron Hydrochloride from Pressure-sensitive Adhesive Matrices through Hairless Mouse Skin

  • Gwak, Hye-Sun;Oh, Ik-Sang;Chun, In-Koo
    • Archives of Pharmacal Research
    • /
    • v.26 no.8
    • /
    • pp.644-648
    • /
    • 2003
  • To investigate the feasibility of developing a new ondansetron transdermal system, the effects of vehicles and penetration enhancers on the in vitro permeation of ondansetron hydrochloride (OS) from a pressure-sensitive adhesive (PSA) matrices across dorsal hairless mouse skin were studied. Vehicles employed in this study consisted of various ratios of propylene glycol monocaprylate (PGMC)-diethylene glycol monoethyl ether (DGME) co-solvents and PGMC-propylene glycol (PG) co-solvents with 3% oleic acid. $Duro-Tak^\circledR$ 87-2100 and $Duro-Tak^\circledR$ 87-2196 were used as PSAs. The concentration of DGME in PGMC-DGME co-solvent system affected the release rate; as the concentration of DGME increased, the release rate decreased. The cumulative release amount of OS increased as the ratio of PSA to drug solution decreased. The permeation flux was also primarily affected by the amount of PSAs; as the amount decreased, the permeation flux increased. The overall fluxes from matrix formulations were significantly lower when compared to those obtained from solution formulations. The ratio of PG to PGMC did not affect permeation flux, while the lag time decreased significantly from $5.14\pm3.31 to 0.31\pm0.12$ h as the PG increased from 40% to 60%.

A Combustion Characteristic Analysis of PMMA by Cone Heater of the flexible Heat Flux (콘 히터의 유동적인 열선속을 적용한 PMMA의 연소 특성 분석)

  • Moon, Sung-Woong;Ryu, Sang-Hoon;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.39-44
    • /
    • 2010
  • The cone calorimeter method which is currently used to measure the heat release rate has a fixed rate of radiation. However, in the real fire, when flame combustible material burns, it releases the identical heat flux. We measured the changes of temperature of a fire using FDS in order to analyze flexible heat flux of combustion characteristics. In this study, the rate of radiation of cone calorimeter was adopted by using FDS. Follow those results, it produce between the rate of radiation in the growth period and decline period have a significant impact on heat release rate of PMMA.

Calculation of Phosphorus Release Flux from Benthic Sediments in Sookchun Lake (소옥천 호소 저서퇴적물의 인 용출률 산정)

  • Ryu, Byong-Ro
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.1
    • /
    • pp.9-21
    • /
    • 2015
  • This study examined pollution level of sediment in Sookchun lake, and studied dredging validity by examining phosphorous release characteristics on surface polluted soil. Total phosphorous, the principal cause of algal blooms, exceeded dredging assessment standards regarding Daechung lake (1.5 mg/g) at all points. Also at all points, total nitrogen exceeded the dredging assessment standard regarding Paldang Lake (1.1 mg/g), but fell short of the standard regarding Daechung lake (3.0 mg/g). Dredging zone was suggested in this study is Chuso water body (WS-6~WS-12) in Sookchun lake. In relation to sediment pollution levels measured at different depths, LOI tended to decrease as it became deeper. The concentrations of T-N varied depending upon the depth as well as points, but no regular pattern was observed. The depth and site did not significantly influence T-P. From the results of phosphorous release tests, it was shown that total phosphorous release flux was calculated to be $7.2{\sim}15.4mg/m^2/d$ for anaerobic condition, $0.5{\sim}2.0mg/m^2/d$ for aerobic condition and $2.0{\sim}4.1mg/m^2/d$ for facultative condition. Release flux and T-P concentration of surface sediments had positive correlation ($R^2$ 0.7871). And The corelation between release flux and DO condition in reactor had strong negative correlation ($R^2$ 0.8824).

Pollutant Flux Releases During Summer Monsoon Period based on Hydrological Modeling in Two Forested Watersheds, Soyang Lake

  • Kang, S.H.
    • Environmental Engineering Research
    • /
    • v.14 no.1
    • /
    • pp.13-18
    • /
    • 2009
  • In this study, specific pollutant releases during the Asian monsoon season were estimated and the information was applied to the non-point pollutant sources management from two forested watersheds of the Soyang Lake. The two watersheds are part of the 2,703 km2 Soyang Lake watershed in the northern region of the Han River. The outlets of the two watersheds were respectively analyzed for continuous water quality concentration and for discharge during various single rainfall events. Statistical power function methods are utilized to compare stream discharge and pollutant flux release during the study period. Based on the monitoring data during the study period, the specific load flux method using simulated discharge was conducted and validated in the two watersheds. The model predictions corresponded well with the measured and calculated pollutant releases. The modeling approach taken in this study was found to be applicable for the two forested watersheds.

Ignition and Heat Release Rate of Wood-based Materials in Cone Calorimeter Tests

  • Park, Joo-Saeng;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.1-8
    • /
    • 2008
  • This study was performed to evaluate the burning characteristics of wood-based materials and the effect of surface treatment of fire retardant using cone calorimeter. Four types of wood-based materials, such as Plywood, Oriented Strand Board (OSB), Particle Board (PB) and Medium Density Fiberboard (MDF), were tested at a constant heat flux of $50kW/m^2$ to investigate the time to ignition, mass loss rate, heat release rate, effective heat of combustion, etc. In addition, each type of wood-based material was tested at the same heat flux after fire retardant treatment on the surface to evaluate the effect of this treatment on the burning characteristics. The surface treatment of fire retardant, by the amount of $110g/m^2$, delayed the time to ignition almost twice. However, it was indicated that heat release rate, mass loss rate, and effective heat of combustion were not significantly affected by fire retardants treatment for all types of wood-based materials.

Combustion Characteristics of Fiber Reinforced Plastic by Cone Calorimeter (콘칼로리미터를 이용한 섬유강화플라스틱(FRP)의 연소특성)

  • 이근원;김관응;이두형
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.67-72
    • /
    • 2004
  • This study describes to assess combustion characteristics of fiber reinforced plastic (FRP) that is used an elements of building or structure in workplace. The combustion characteristics of the fiber reinforced plastic were carried out using by a Cone Calorimeter according to ISO 5660 standard. As the results of this study, the time to ignition and heat release rate of the fiber reinforced plastic was differ with heat flux of irradiance and content of flame retardant agent. The heat release rate of the fiber reinforced plastic was increased with increasing heat flux of irradiance. The flashover propensity of the fiber reinforced plastic using time to ignition and peak heat release rate was examined according to classification method by R.V. Petrella.

Characteristics of Carbon Circulation for Ascidian Farm in Jindong Bay in Summer and Winter (진동만 미더덕 양식장의 하계 및 동계 탄소 순환 특성)

  • Park, Jihye;Cho, Yoonsik;Lee, Won-Chan;Hong, Sokjin;Kim, Hyung-Chul;Kim, Jeong-Bae;Park, Junghyun
    • Journal of Wetlands Research
    • /
    • v.14 no.2
    • /
    • pp.211-221
    • /
    • 2012
  • The ascidian Styela clava has been one of the favorite seafood in Korea. Suspended culture of Styela clava was initiated in 2001 and the annual production reached 15,084 M/T, but declined to 2,655 M/T in 2011. In order to solve this problem, it is necessary to estimate the material balance according to the farm-environment. Vertical particulate fluxes and release fluxes were estimated at 2 stations, an ascidian farm (AF) and a non-cultivated area (control) in Jindong Bay. An in-situ benthic chamber(BelcI) was used in summer and winter season. The sedimentation fluxes of organic carbon were 72 mmol C $m^{-2}\;d^{-1}$, 93 mmol C $m^{-2}\;d^{-1}$, 34 mmol C $m^{-2}\;d^{-1}$ in Jul. AF, Feb. AF, Feb. control. The organic carbon oxidation rates were 13 mmol C $m^{-2}\;d^{-1}$, 81 mmol C $m^{-2}\;d^{-1}$, 31 mmol C $m^{-2}\;d^{-1}$, in each. The release fluxes of nutrients followed the general pattern, well. Consequently, the ratio of the organic carbon burial fluxes were 20:4:1, in each. By the estimation of the carbon circulation, it could be a scientific basis to analyze the reason of production decline for cultivated organism.