• 제목/요약/키워드: relaxation times

검색결과 389건 처리시간 0.027초

전력용 소자 제작을 위한 유기박막 전기물성에 관한 연구 (A Study on the Electrical Physical Properties of Organic Thin Films for Manufacture in Power Device)

  • 조수영;김영근;최영일;송진원;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집
    • /
    • pp.37-41
    • /
    • 2004
  • In this paper, evaluation of physical properties about dielectric relaxation phenomena by the detection of the surface pressures and displacements current on the monolayer films of phospolipid monomolecular DLPC, DMPC using pressure stimulus. As a result, the changed surface pressure, displacement current and the transition forms of dipole moment of phospolipid monomolecular in area per molecular by pressure stimulus were conformed well. It was known that the monolayers by linear relationship for decision of dielectric relaxation time between compressure speed and molecule area By according to the linear relationship relation get that frictional constant, DLPC was $1.89{\times}10^{-19}$ [Js] and DMPC was $0.722{\times}10^{-19}$[Js]. lt is found that the phospolipid monolayer of dielectric relaxation takes a little time and depend on the molecular area.

  • PDF

27Al and 87Rb Nuclear Magnetic Resonance Study of the Relaxation Mechanisms of RbAl(CrO4)2·2H2O Single Crystals

  • Kim, Jae Sung;Lim, Ae Ran
    • 한국자기공명학회논문지
    • /
    • 제16권2호
    • /
    • pp.111-121
    • /
    • 2012
  • The spin-lattice relaxation times, $T_1$, and spin-spin relaxation times, $T_2$, of the $^{27}Al$ and $^{87}Rb$ nuclei in $RbAl(CrO_4)_2{\cdot}2H_2O$ crystals were investigated. The presence of only one resonance line for the $^{27}Al$ nuclei indicates that the results in a dynamical averaging of the crystal electric field that produces a cubic symmetry field. The changes in the temperature dependence of $T_1$ are related to variations in the symmetry of the octahedra of water molecules surrounding $Al^+$ and $Rb^+$. The $T_1$ values for the $^{27}Al$ and $^{87}Rb$ nuclei are different due to differences in the local environments of these ions. We also compared these $^{27}Al$ and $^{87}Rb$ NMR results with those obtained for $RbAl(CrO_4)_2{\cdot}2H_2O$ crystals. The relaxation mechanisms of $RbAl(XO_4)_2{\cdot}nH_2O$ (X=Cr and S) crystals are characterized by completely different NMR behaviors.

랜덤 수 생성 회로를 이용한 EMI Noise 저감 회로 (The EMI Noise Reduction Circuit with Random Number Generator)

  • 김성진;박주현;김상윤;구자현;김형일;이강윤
    • 한국전자파학회논문지
    • /
    • 제26권9호
    • /
    • pp.798-805
    • /
    • 2015
  • 본 논문에서는 랜덤 수 생성 회로를 통해 Relaxation Oscillator의 주파수를 불규칙하게 변환하여 EMI Noise를 최소화하는 방법을 제시한다. 또한, DC-DC Converter에 이 기법이 적용되었을 때의 효과와 이 결과가 RF Receiver system에 미치는 효과를 Noise 측면에서 연구하였다. 제안하는 Relaxation Oscillator 출력 중심주파수는 7.9 MHz이고, 온도보상기법을 적용하여 온도변화에 따라 주파수가 보상되도록 설계하였다. 이 칩은 $0.18{\mu}m$ 공정으로 설계하였고, 칩의 면적은 $220{\mu}m{\times}280{\mu}m$이다. 전류 소모는 공급전압인 1.8 V에서 $500{\mu}A$이다.

Phantom-Validated Reference Values of Myocardial Mapping and Extracellular Volume at 3T in Healthy Koreans

  • Lee, Eunjin;Kim, Pan Ki;Choi, Byoung Wook;Jung, Jung Im
    • Investigative Magnetic Resonance Imaging
    • /
    • 제24권3호
    • /
    • pp.141-153
    • /
    • 2020
  • Purpose: Myocardial T1 and T2 relaxation times are affected by technical factors such as cardiovascular magnetic resonance platform/vendor. We aimed to validate T1 and T2 mapping sequences using a phantom; establish reference T1, T2, and extracellular volume (ECV) measurements using two sequences at 3T in normal Koreans; and compare the protocols and evaluate the differences from previously reported measurements. Materials and Methods: Eleven healthy subjects underwent cardiac magnetic resonance imaging (MRI) using 3T MRI equipment (Verio, Siemens, Erlangen, Germany). We did phantom validation before volunteer scanning: T1 mapping with modified look locker inversion recovery (MOLLI) with 5(3)3 and 4(1)3(1)2 sequences, and T2 mapping with gradient echo (GRE) and TrueFISP sequences. We did T1 and T2 mappings on the volunteers with the same sequences. ECV was also calculated with both sequences after gadolinium enhancement. Results: The phantom study showed no significant differences from the gold standard T1 and T2 values in either sequence. Pre-contrast T1 relaxation times of the 4(1)3(1)2 protocol was 1142.27 ± 36.64 ms and of the 5(3)3 was 1266.03 ± 32.86 ms on the volunteer study. T2 relaxation times of GRE were 40.09 ± 2.45 ms and T2 relaxation times of TrueFISP were 38.20 ± 1.64 ms in each. ECV calculation was 24.42% ± 2.41% and 26.11% ± 2.39% in the 4(1)3(1)2 and 5(3)3 protocols, respectively, and showed no differences at any segment or slice between the sequences. We also calculated ECV from the pre-enhancement T1 relaxation time of MOLLI 5(3)3 and the post-enhancement T1 relaxation time of MOLLI 4(1)3(1)2, with no significant differences between the combinations. Conclusion: Using phantom-validated sequences, we reported the normal myocardial T1, T2, and ECV reference values of healthy Koreans at 3T. There were no statistically significant differences between the sequences, although it has limited statistical value due to the small number of subjects studied. ECV showed no significant differences between calculations based on various pre- and post-mapping combinations.

Debye Screening Effect on Scaling Behavior of Longest Relaxation Time of Biological Polyelectrolyte Chain

  • Lee, Jeong Yong;Sung, Jung Mun;Yoon, Kyu;Chun, Myung-Suk;Jung, Hyun Wook
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권12호
    • /
    • pp.3703-3708
    • /
    • 2013
  • The scaling relationship of the longest relaxation time of a single chain of semiflexible biological polyelectrolyte has been investigated by performing well-established coarse-grained Brownian dynamics simulations. Two kinds of longest relaxation times were estimated from time-sequences of chain trajectories, and their behaviors were interpreted by applying the scaling law for different molecular weights of polyelectrolyte and Debye lengths. The scaling exponents for longest stress relaxation and rotational relaxation are found in the ranges of 1.67-1.79 and 1.65-1.81, respectively, depending on the physicochemical interaction of electrostatic Debye screening. The scaling exponent increases with decreasing screening effect, which is a special feature of polyelectrolytes differing from neutral polymers. It revealed that the weak screening allows a polyelectrolyte chain to follow the behavior in good solvent due to the strong electrostatic repulsion between beads.

복분자(覆盆子)의 토끼 음경해면체 평활근 이완효과 (Relaxation Effects of Rubus coreanus in Isolated Rabbit Corpus Cavernosum Smooth Muscle)

  • 박선영;이평재;신선미;김호현
    • 동의생리병리학회지
    • /
    • 제27권4호
    • /
    • pp.400-408
    • /
    • 2013
  • This study aimed to investigate the relaxation effects and its underlying mechanisms of Rubus coreanus(RC) extract in contracted rabbit corpus cavernous tissues by phenylephrine(PE) $1{\mu}M$. In order to define the relaxation effects of RC, rabbit corpus cavernous tissues were prepared in $2{\times}2{\times}6mm$ sized strip. The dose-dependent relaxation responses of RC at 0.01-3.0 $mg/m{\ell}$ in contracted strips induced by PE were measured and also observed after endothelial denudation. To analyze the underlying mechanisms of RC-induced relaxation, indomethacin(IM), tetraethylammonium chloride(TEA), $N{\omega}$-nitro-L-arginine (L-NNA), methylene blue(MB) were treated before RC extract infused into precontracted strips induced by PE. To study the effect of RC extract on influx of extracellular $Ca^{2+}$ in corpus cavernous strips, calcium chloride(Ca) 1 mM infused into precontracted strips induced by PE after pretreatment of RC extract in $Ca^{2+}$-free krebs-ringer solution. To investigate cytotoxic activity and nitric oxide(NO) concentration of RC extract on human umbilical vein endothelial cell(HUVEC), cell viability on HUVEC was measured by MTT assay, and NO concentration was measured by Griess reagent system. The cavernous strips were significantly relaxed by RC extract at 1.0 $mg/m{\ell}$, 3.0 $mg/m{\ell}$ and the relaxation responses to RC were inhibited significantly by endothelial disruption. The pretreatment of IM, TEA didn't affect RC extract-induced endothelium-dependent relaxation, but the pretreatment of L-NNA, MB reduced RC extract-induced endothelium-dependent relaxation. When $Ca^{2+}$ was supplied the cavernous strips which were precontracted by PE in a $Ca^{2+}$-free krebs-ringer solution, contraction of strips was increased, but pretreatment of RC inhibited contractile response to $Ca^{2+}$. When RC extract was applicated on HUVEC, NO concentration was increased. Our findings show that RC extract exerts a relaxing effect on corpus cavernosum in part by suppressing influx of extracellular $Ca^{2+}$ through activating the NO-cGMP system.

Relaxation Characteristic of the Disordered Lead Scandium Niobate

  • Kim, Yeon Jung
    • Applied Science and Convergence Technology
    • /
    • 제24권3호
    • /
    • pp.47-52
    • /
    • 2015
  • The correlation between admittance and dielectric spectroscopy of dielectric relaxation in lead scandium noibate, have been investigated. Lead scandium niobate, with composition $PbSc_{0.5}Nb_{0.5}O_3$, was prepared by conventional solid state synthesis. Conductance Y'(G), susceptance Y"(B) and capacitance C of lead scandium niobate as a function of frequency and temperature were measured. From the temperature-dependence of RLC circuit, insight into physical significance of the dielectric properties of lead scandium niobate is obtained. The relative strong frequency dependent of dielectric properties in lead scandium niobate is observed, and the phase transition occurred at a broad temperature region. Also, the value of critical exponent ${\gamma}$=1.6 showed on heating process. The long relaxation times part enlarged diffuse by conductivity effects with increasing temperature, and the ordering between $Sc^{3+}$ and $Nb^{5+}$ in PSN influences complex admittance and dielectric properties. Confirmed the typical characteristic of lead-type relaxor in the Raman spectra of lead scandium niobate and major ranges are between 400 and $900cm^{-1}$.

Dielectric Relaxation of Siloxane-Epoxy Copolymers

  • Kim, Chy-Hyung;Shin, Jae-Sup
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권3호
    • /
    • pp.413-416
    • /
    • 2002
  • The dielectric responses of 10 and 40 wt% siloxane-epoxy copolymers were investigated in temperature range near the glass transition of polydimethylsiloxane at which the dielectric transitions were also observed. On the other hand, the pure epoxy did not show any dielectric transition in measurement temperature range -90 to 150 $^{\circ}C.$ The experimental data showed that for the copolymer investigated, the temperature-frequency super-position principle could be applied to the dielectric response. From the Cole-Cole equation, the dielectric relaxation of the 10 wt% siloxane near the glass transition temperature resulted in a broad distribution with ${\beta}=$ 0.19 and the relaxation time at -70 $^{\circ}C$ was 5.3 ${\times}$ $10^{-2}$s. The glass transition temperature, 188 K, was estimated by using WLF relation, which was consistent with the data presented in experiment.

Strongly coupled partitioned six degree-of-freedom rigid body motion solver with Aitken's dynamic under-relaxation

  • Chow, Jeng Hei;Ng, E.Y.K.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제8권4호
    • /
    • pp.320-329
    • /
    • 2016
  • An implicit method of solving the six degree-of-freedom rigid body motion equations based on the second order Adams-Bashforth-Moulten method was utilised as an improvement over the leapfrog scheme by making modifications to the rigid body motion solver libraries directly. The implementation will depend on predictor-corrector steps still residing within the hybrid Pressure Implicit with Splitting of Operators - Semi-Implicit Method for Pressure Linked Equations (PIMPLE) outer corrector loops to ensure strong coupling between fluid and motion. Aitken's under-relaxation is also introduced in this study to optimise the convergence rate and stability of the coupled solver. The resulting coupled solver ran on a free floating object tutorial test case when converged matches the original solver. It further allows a varying 70%-80% reduction in simulation times compared using a fixed under-relaxation to achieve the required stability.

CT 조영제가 MR 조영제의 이완율에 미치는 영향 (Effects of CT Contrast Medium on the Relaxation Rate of MR Contrast Medium)

  • 권순용;강충환;정현근;박진서;김성호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권2호
    • /
    • pp.103-107
    • /
    • 2018
  • In MR, the iodine CT contrast medium reduces the T1 and T2 relaxation times of the substance, resulting in a change in signal intensity. This study aimed to measure the relaxation rate of MR contrast medium with or without diluting CT contrast medium and analyzed the effect of CT contrast medium. Undiluted Gadoteridol solution was diluted with saline to prepare MR contrast medium phantoms with various levels of Gadoteridol concentrations. Moreover, undiluted Iomeprol was mixed with the prepared MR contrast medium phantoms at 1:1 ratio to make MR contrast medium phantoms with containing CT contrast medium for the experiment. T1 and T2 mappings were conducted to quantitatively evaluate the relaxation time and relaxation rate of these phantoms. The results showed that the T1 and T2 relaxation time and relaxation rate of MR contrast medium diluted with CT contrast medium were significantly (p<0.05) shorter than those of MR contrast medium not diluted with CT contrast medium. The results of this study imply that, when MR contrast medium shall be used after injecting CT contrast medium, CT contrast medium should be discharged enough. Moreover, it would be desirable to conduct CT test after taking MRI test in order to reduce the effects of CT contrast medium on MR contrast medium.