• Title/Summary/Keyword: relative wind speed reduction

Search Result 20, Processing Time 0.026 seconds

Effect of Shade Net on Reduction of Freezing Damage at a Tea Garden (차밭에 설치된 차광망의 동해경감 효과)

  • Hwang, Jung-Gyu;Kim, Yong-Duck
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.16 no.2
    • /
    • pp.146-154
    • /
    • 2014
  • In the result of effect on freezing damage reduction by the shade net colors and the shade rate to tea trees during wintering period, the high shade ratio decreased tea trees growth and increased freezing damage and 55% of shade ratio based on non treatment developed new leafs and green leaf productivity. By the shade net colors, colorless shade net (55% of shade type) treatment and green shade net treatment increased green leaf productivity and decreased damaged area compare to non treatment shade net and black shade net treatment. Colorless net shade treatment reduced over 50% of freezing damage and increased (10a) 68 kg for green leaf productivity compare to non treatment shade net. The colors of shade net treatments for reduction freezing damaged in order of Black < Green < Colorless but reduction of freezing damage was so high. In the relative microclimates, treatment shade nets were $0.7^{\circ}C$ lower, average relatively humidity 14.9% higher, soil temperature $0.6^{\circ}C$ lower and soil moisture 4.6% higher than non treatment shade net. And treatment shade nets decreased average wind speed 0.7 m/s and it showed us treatment net shades effected to excessive evapotranspiration and soil dry by wind and considered one of good solution for freezing damages.

Analysis of the Long-term Trend of PM10 Using KZ Filter in Busan, Korea (KZ 필터를 이용한 부산지역 PM10의 장기 추세 분석)

  • Do, Woo-gon;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.26 no.2
    • /
    • pp.221-230
    • /
    • 2017
  • To determine the effect of air pollution reduction policies, the long-term trend of air pollutants should be analyzed. Kolmogorov-Zurbenko (KZ) filter is a low-pass filter, produced through repeated iterations of a moving average to separate each variable into its temporal components. The moving average for a KZ(m, p) filter is calculated by a filter with window length m and p iterations. The output of the first pass subsequently becomes the input for the next pass. Adjusting the window length and the number of iterations makes it possible to control the filtering of different scales of motion. To break down the daily mean $PM_{10}$ into individual time components, we assume that the original time series comprises of a long-term trend, seasonal variation, and a short-term component. The short-term component is attributable to weather and short-term fluctuations in precursor emissions, while the seasonal component is a result of changes in the solar angle. The long-term trend results from changes in overall emissions, pollutant transport, climate, policy and/or economics. The long-term trend of the daily mean $PM_{10}$ decreased sharply from $59.6ug/m^3$ in 2002 to $44.6ug/m^3$ in 2015. This suggests that there was a long-term downward trend since 2005. The difference between the unadjusted and meteorologically adjusted long-term $PM_{10}$ is small. Therefore, we can conclude that $PM_{10}$ is unaffected by the meteorological variables (total insolation, daily mean temperature, daily mean relative humidity, daily mean wind speed, and daily mean local atmospheric pressure) in Busan.

Analysis of the Influence of Street Trees on Human Thermal Sensation in Summer (여름철 인간 열환경지수에 미치는 가로수의 영향 분석)

  • Jo, Sang-man;Hyun, Cheol-ji;Park, Soo-kuk
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.5
    • /
    • pp.105-112
    • /
    • 2017
  • In order to analyze the effect of street trees on human thermal sensation(thermal comfort) in summer, microclimatic data were measured and analyzed at sunny and shaded locations of two deciduous broadleaf and three broadleaf evergreen species of street trees. As a result, the mean differences by species in air temperature, relative humidity and wind speed were small: $0.2{\sim}1.5^{\circ}C$, 0.9~5.3% and $0.1{\sim}0.5 ms^{-1}$, respectively, but the mean difference in the mean radiant temperature was great, $27.1^{\circ}C$. In the results of physiological equivalent temperature(PET) and universal thermal climate index(UTCI), which are human thermal sensation(thermal comfort) indexes, the shaded locations by the trees showed mean reduction rates of 21.2~31.3% in the PET compared with the sunny location, which are equivalent to 1.5~2.5 levels of thermal perception. Also, 12.7~20.0% in the UTCI was reduced by the trees' shadows, which is equivalent to 1~1.5 levels of heat stress. In addition, although the broadleaf evergreen trees had 5% greater mean reduction in PET than that of the deciduous broadleaf trees, the Zelkova serrata that belonged to the deciduous broadleaf trees showed the equivalent thermal reduction effect as the broadleaf evergreen trees because of the high density of branches and leaves. Therefore, the mean radiant temperature and the density of the crown(branches and leaves) were the main influences in thermal modification by these street trees in summer.

Development and Analysis of COMS AMV Target Tracking Algorithm using Gaussian Cluster Analysis (가우시안 군집분석을 이용한 천리안 위성의 대기운동벡터 표적추적 알고리듬 개발 및 분석)

  • Oh, Yurim;Kim, Jae Hwan;Park, Hyungmin;Baek, Kanghyun
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.6
    • /
    • pp.531-548
    • /
    • 2015
  • Atmospheric Motion Vector (AMV) from satellite images have shown Slow Speed Bias (SSB) in comparison with rawinsonde. The causes of SSB are originated from tracking, selection, and height assignment error, which is known to be the leading error. However, recent works have shown that height assignment error cannot be fully explained the cause of SSB. This paper attempts a new approach to examine the possibility of SSB reduction of COMS AMV by using a new target tracking algorithm. Tracking error can be caused by averaging of various wind patterns within a target and changing of cloud shape in searching process over time. To overcome this problem, Gaussian Mixture Model (GMM) has been adopted to extract the coldest cluster as target since the shape of such target is less subject to transformation. Then, an image filtering scheme is applied to weigh more on the selected coldest pixels than the other, which makes it easy to track the target. When AMV derived from our algorithm with sum of squared distance method and current COMS are compared with rawindsonde, our products show noticeable improvement over COMS products in mean wind speed by an increase of $2.7ms^{-1}$ and SSB reduction by 29%. However, the statistics regarding the bias show negative impact for mid/low level with our algorithm, and the number of vectors are reduced by 40% relative to COMS. Therefore, further study is required to improve accuracy for mid/low level winds and increase the number of AMV vectors.

Agro-Environmental Observation in a Rice Paddy under an Agrivoltaic System: Comparison with the Environment outside the System (영농형 태양광 시설 하부 논에서의 농업환경 관측 및 시설 외부 환경과의 비교)

  • Kang, Minseok;Sohn, Seungwon;Park, Juhan;Kim, Jongho;Choi, Sung-Won;Cho, Sungsik
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.23 no.3
    • /
    • pp.141-148
    • /
    • 2021
  • Agrivoltaic systems, also called solar sharing, stated from an idea that utilizes sunlight above the light saturation point of crops for power generation using solar panels. It is expected that agrivoltaic systems can realize climate smart agriculture by reducing evapotranspiration and methane emission due to the reduction of incident solar radiation and the consequent surface cooling effect and bring additional income to farms through solar power generation. In this study, to evaluate that agrivoltaic systems are suitable for realization of climate smart agriculture, we conducted agro-environmental observations (i.e., downward/upward shortwave/longwave radiations, air temperature, relative humidity, water temperature, soil temperature, and wind speed) in a rice paddy under an agrivoltaic system and compared with the environment outside the system using automated meteorological observing systems (AMOS). During the observation period, the spatially averaged incoming solar radiation under the agrivoltaic system was about 70% of that in the open paddy field, and clear differences in the soil and water temperatures between the paddy field under the agrivoltaic system and the open paddy field were confirmed, although the air temperatures were similar. It is required in the near future to confirm whether such environmental differences lead to a reduction in water consumption and greenhouse gas emissions by flux measurements.

Analysis of Thermal Environment Improving Effects of Green Curtain in Summer (Green Curtain 형식의 벽면녹화시스템을 통한 여름철 건물 실내 열환경 비교 분석)

  • Lee, Sunyoung;Jo, Sangman;Park, Sookuk
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.5
    • /
    • pp.80-89
    • /
    • 2022
  • In order to solve the limitations of horizontal thermal environment improvement, this study compared the thermal environment of the indoor and outdoor of a building in summer according to the presence or absence of a green curtain, a vertical greening method. In the summer of 2021, the air temperature, relative humidity, wind speed, and shortwave and longwave radiation were measured at a central point inside a building and the grass field outside of the building to determine the human thermal sensation index, PET and UTCI. As a result, the green curtain showed an average 1.6℃ cooler air temperature during the daytime, but it did not have an effect at night. For relative humidity, it showed higher humidity indoors by an average of 5.6% and 1.0% during the daytime and at night, respectively. Wind speed was 1.4-1.8 ms-1 and 1.4-1.5 ms-1 higher outdoors on average during the daytime and at night, respectively, showing a high value outdoors regardless of whether a green curtain was installed. The green curtain showed an average indoor mean radiant temperature reduction effect of 4.7℃ during the daytime, but it did not have an effect at night. In PET and UTCI, the green curtain reduced the indoor PET by about a 1/3 level, an average of 2.1℃, and the indoor UTCI by about a 1/6 level, an average of 1.1℃, during the daytime. However, no effects appeared in PET and UTCI at night. For landscape planning, a green curtain can effectively modify the thermal environment during the daytime in summer.

The Effects of Pergola Wisteria floribunda's LAI on Thermal Environment (그늘시렁 Wisteria floribunda의 엽면적지수가 온열환경에 미치는 영향)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.6
    • /
    • pp.115-125
    • /
    • 2017
  • This study was to investigate the user's thermal environments under the pergola($L\;7,200{\times}W\;4,200{\times}H\;2,700mn$) covered with Wisteria floribunda(Willd.) DC. according to the variation of leaf area index(LAI). We carried out detailed measurements with two human-biometeorological stations on a popular square Jinju, Korea($N35^{\circ}10^{\prime}59.8^{{\prime}{\prime}}$, $E\;128^{\circ}05^{\prime}32.0^{{\prime}{\prime}}$, elevation: 38m). One of the stations stood under a pergola, while the other in the sun. The measurement spots were instrumented with microclimate monitoring stations to continuously measure air temperature and relative humidity, wind speed, shortwave and longwave radiation from the six cardinal directions at the height of 0.6m so as to calculate the Universal Thermal Climate Index(UTCI) from $9^{th}$ April to $27^{th}$ September 2017. The LAI was measured using the LAI-2200C Plant Canopy Analyzer. The analysis results of 18 day's 1 minute term human-biometeorological data absorbed by a man in sitting position from 10am to 4pm showed the following. During the whole observation period, daily average air temperatures under the pergola were respectively $0.7{\sim}2.3^{\circ}C$ lower compared with those in the sun, daily average wind speed and relative humidity under the pergola were respectively 0.17~0.38m/s and 0.4~3.1% higher compared with those in the sun. There was significant relationship in LAI, Julian day number and were expressed in the equation $y=-0.0004x^2+0.1719x-11.765(R^2=0.9897)$. The average $T_{mrt}$ under the pergola were $11.9{\sim}25.4^{\circ}C$ lower and maximum ${\Delta}T_{mrt}$ under the pergola were $24.1{\sim}30.2^{\circ}C$ when compared with those in the sun. There was significant relationship in LAI, reduction ratio(%) of daily average $T_{mrt}$ compared with those in the sun and was expressed in the equation $y=0.0678{\ln}(x)+0.3036(R^2=0.9454)$. The average UTCI under the pergola were $4.1{\sim}8.3^{\circ}C$ lower and maximum ${\Delta}UTCI$ under the pergola were $7.8{\sim}10.2^{\circ}C$ when compared with those in the sun. There was significant relationship in LAI, reduction ratio(%) of daily average UTCI compared with those in the sun and were expressed in the equation $y=0.0322{\ln}(x)+0.1538(R^2=0.8946)$. The shading by the pergola covered with vines was very effective for reducing daytime UTCI absorbed by a man in sitting position at summer largely through a reduction in mean radiant temperature from sun protection, lowering thermal stress from very strong(UTCI >$38^{\circ}C$) and strong(UTCI >$32^{\circ}C$) down to strong(UTCI >$32^{\circ}C$) and moderate(UTCI >$26^{\circ}C$). Therefore the pergola covered with vines used for shading outdoor spaces is essential to mitigate heat stress and can create better human thermal comfort especially in cities during summer. But the thermal environments under the pergola covered with vines during the heat wave supposed to user "very strong heat stress(UTCI>$38^{\circ}C$)". Therefore users must restrain themselves from outdoor activities during the heat waves.

Heat Budget Analysis of Light Thin Layer Green Roof Planted with Zoysia japonica (한국잔디식재 경량박층형 옥상녹화의 열수지 해석)

  • Kim, Se-Chang;Lee, Hyun-Jeong;Park, Bong-Ju
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.6
    • /
    • pp.190-197
    • /
    • 2012
  • The purpose of this study was to evaluate thermal environment and heat budget of light thin layer green roof through an experiment in order to quantify its heat budget. Two concrete model boxes($1.2m(W){\times}1.2m(D){\times}1.0m(H)$) were constructed: One experiment box with Zoysia japonica planted on substrate depth of 10cm and one control box without any plant. Between June 6th and 7th, 2012, outside climatic conditions(air temperature, relative humidity, wind direction, wind speed), evapotranspiration, surface and ceiling temperature, heat flux, and heat budget of the boxes were measured. Daily maximum temperature of those two days was $29.4^{\circ}C$ and $30^{\circ}C$, and daily evapotranspiration was $2,686.1g/m^2$ and $3,312.8g/m^2$, respectively. It was found that evapotranspiration increased as the quantity of solar radiation increased. A surface and ceiling temperature of those two boxes was compared when outside air temperature was the greatest. and control box showed a greater temperature in both cases. Thus it was found that green roof was effective in reducing temperature. As results of heat budget analysis, heat budget of a green roof showed a greater proportion of net radiation and latent heat while heat budget of the control box showed a greater proportion of sensible heat and conduction heat. The significance of this study was to analyze heat budget of green roof temperature reduction. As substrate depth and types, species and seasonal changes may have influences on temperature reduction of green roof, further study is necessary.

Yield Response of Rice Affected by Adverse Weather Conditions Occurred in 1999 (1999년에 발생한 기상재해 유형별 벼 수량반응조사 연구)

  • Ju Young-Cheoul;Lim Gab-June;Han Sang-Wook;Park Jung-Soo;Cho Young-Cheol;Kim Soon-Jae
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.2 no.1
    • /
    • pp.1-8
    • /
    • 2000
  • The objectives of this study were to investigate weather conditions which induced discolored grains and viviparous germination, and to evaluate yield responses following viviparous germination during mid- and late- ripening stage, the submergence during reproductive growth stage, and lodging in the yellow ripe stage. Weather conditions which caused glume discoloration at heading stage were 21.3-26.4$^{\circ}C$ in average temperature, 75.2-98.4% in relative humidity, 19.3 in transpiration coefficient and 10.8-13.8 m/sec. in wind speed. Yield reduction was 26-27% and 10~17%, respectively, when the glume discoloration rates were 63.2-65.7% and 38.3-45.2%, obviously due to the decrease in percent of fertile grain and ripening ratio. Weather conditions during continuous rain for 7 days were 96% in relative humidity, 18.9$^{\circ}C$ in average temperature, 21.9$^{\circ}C$ in maximum temperature, and 16.8$^{\circ}C$ in minimum temperature, causing the most viviparous germination in Juanbyeo(45.5%), followed by Jinbubyeo(14.5%), Bongkwangbyeo(14.2%), and Obongbyeo(12.6%). Lateral tillers started to occur when the submergence at the depth of 1.5-2 m lasted one day during the reproductive growth stage. The submergence for 2-3 days at 3-4 m of water depth induced 269-571 lateral tillers/m$^2$, supporting 32-52% of the total yield. The rice yield in the paddy fields which were left under the lodging conditions until harvesting was not different compared to that of the paddy fields which were kept upright by tieing them together after lodging, but perfect grain ratio decreased about 9.1% in the transplanting culture and 12.5% in the direct seeding culture on dry paddy field because of the increase in immature grains.

  • PDF

Analysis of Thermal Environment Modification Effects of Street Trees Depending on Planting Types and Street Directions in Summertime Using ENVI-Met Simulation (ENVI-Met 시뮬레이션을 통한 도로 방향별 가로수 식재 형태에 따른 여름철 열환경 개선 효과 분석)

  • Lim, Hyeonwoo;Jo, Sangman;Park, Sookuk
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.2
    • /
    • pp.1-22
    • /
    • 2022
  • The modification effects of street trees on outdoor thermal comfort in summertime according to tree planting types and road direction were analyzed using a computer simulation program, ENVI-met. With trees, the air temperature and wind speed decreased, and the relative humidity increased. In the case of mean radiant temperature (Tmrt) and human thermal sensation, physiological equivalent temperature (PET) and universal thermal climate index (UTCI), there was a decrease during the daytime. The greatest change among the meteorological factors by trees happened in Tmrt, and PET and UTCI showed similar patterns with Tmrt·The most effective tree planting type on thermal comfort modification was low tree height, wide tree crown, high leaf area index, and narrow planting interval (LWDN). Tmrt, PET and UTCI showed a large difference depending on shadow patterns of buildings and trees according to solar altitude and azimuth angles, and building locations. When the building shade areas increased, the thermal modification effect by trees decreased. In particular, results on the east and west sidewalks showed a large deviation over time. When applying the LWDN, the northwest, west and southwest sidewalks showed a significant reduction of 8.6-12.3℃ PET and 4.2-4.5℃ UTCI at 10:00, and the northeast, east and southeast sidewalks showed 8.1-11.8℃ PET and 4.4-5.0℃ UTCI at 16:00. On the other hand, when the least effective type (high tree height, narrow tree crown, low leaf area index, and wide planting interval) was applied, the maximum reduction was up to 1.8℃ PET and 0.9℃ UTCI on the eastern sidewalks, and up to 3.0℃ PET and 0.9℃ UTCI on the western ones. In addition, the difference in modification effects on Tmrt, PET and UTCI between the tree planting types was not significant when the tree effects were reduced by the effects of buildings. These results can be used as basic data to make the most appropriate street tree planting model for thermal comfort improvement in urban areas in summer.