• Title/Summary/Keyword: relative optical density

Search Result 57, Processing Time 0.03 seconds

Measurement of electron temperature and density using Stark broadening of the coaxial focused plasma for extreme ultraviolet (EUV) lithography

  • Lee, Sung-Hee;Hong, Young-June;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.475-475
    • /
    • 2010
  • We have generated Ar plasma in dense plasma focus device with coaxial electrodes for extreme ultraviolet (EUV) lithography and investigated an emitted visible light for electro-optical plasma diagnostics. We have applied an input voltage 4.5 kV to the capacitor bank of 1.53 uF and the diode chamber has been filled with Ar gas of pressure 8 mTorr. The inner surface of the cylindrical cathode has been attatched by an acetal insulator. Also, the anode made of tin metal. If we assumed that the focused plasma regions satisfy the local thermodynamic equilibrium (LTE) conditions, the electron temperature and density of the coaxial plasma focus could be obtained by Stark broadening of optical emission spectroscopy (OES). The Lorentzian profile for emission lines of Ar I of 426.629 nm and Ar II of 487.99 nm were measured with a visible monochromator. And the electron density has been estimated by FWHM (Full Width Half Maximum) of its profile. To find the exact value of FWHM, we observed the instrument line broadening of the monochromator with a Hg-Ar reference lamp. The electron temperature has been calculated using the two relative electron density ratios of the Stark profiles. In case of electron density, it has been observed by the Stark broadening method. This experiment result shows the temporal behavior of the electron temperature and density characteristics for the focused plasma. The EUV emission signal whose wavelength is about 6 ~ 16 nm has been detected by using a photo-detector (AXUV-100 Zr/C, IRD). The result compared the electron temperature and density with the temporal EUV signal. The electron density and temperature were observed to be $10^{16}\;cm^{-3}$ and 20 ~ 30 eV, respectively.

  • PDF

The optical analysis of discharge lamp by Laser

  • Yang, Jong-Kyung;Lee, Jong-Chan;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.570-571
    • /
    • 2005
  • In this paper, we introduced a LIF measurement method and summarized the theoretical side. When an altered wavelength of laser and electric power, lamp applied electric power, we measured the relative density of the metastable state in mercury after observing a laser induced fluorescence signal of 404.8nm and 546.2nm, and confirmed the horizontal distribution of plasma density in the discharge lamp. The results confirmed the resonance phenomenon regarding the energy level of atoms along a wavelength change, and also confirmed that the largest fluorescent signal in 436nm, and that the density of atoms in 546.2nm ($6^3S_1\rightarrow6^3P_2$) were larger than 404.8nm ($6^3S_1\rightarrow6^3P_1$). According to the increase of lamp applied electric power, plasma density increased, too. When increased with laser electric power, the L1F signal reached a saturation state in more than 2.6mJ. When partial plasma density distribution along a horizontal axis was measured using the laser induced fluorescence method, the density decreased by recombination away from the center.

  • PDF

GafChromic Film Dosimetry for Stereotactic Radiosurgery with a Linear Accelerator (선형가속기를 이용한 정위방사선 치료 시 GafChromic Film을 이용한 선량측정)

  • Han Seung Hee;Cho Byung Chul;Park Suk Won;Oh Do Hoon;Park Hee Chul;Bae Hoon Sik
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.167-173
    • /
    • 2003
  • Purpose: The purpose of this study was to evaluate whether a GafChromic film applied to stereotactic radiosurgery with a linear accelerator could provide information on the value for acceptance testing and quality control on the absolute dose and relative dose measurements and/or calculation of treatment planning system. Materials and methods: A spherical acrylic phantom, simulating a patient's head, was constructed from three points. The absolute and relative dose distributions could be measured by inserting a GafChromic film into the phantom. We tested the use of a calibrated GafChromic film (MD-55-2, Nuclear Associate, USA) for measuring the optical density. These measurements were achieved by irradiating the films with a dose of 0-112 Gy employing 6 MV photon. To verify the accuracy of the prescribed dose delivery to a target isocenter using a five arc beams (irradiated in 3 Gy per one beam) setup, calculated by the Linapel planning system the absolute dose and relative dose distribution using a GafChromic film were measured. All the irradiated films were digitized with a Lumiscan 75 laser digitizer and processed with the RIT113 film dosimetry system. Results: We verified the linearity of the Optical Density of a MD-55-2 GafChromic film, and measured the depth dose profile of the beam. The absolute dose delivered to the target was close to the prescribed dose of Linapel within an accuracy for the GafChromic film dosimetry (of $\pm$3$\%$), with a measurement uncertainty of $\pm$1 mm for the 50$\~$90$\%$ isodose lines. Conclusion: Our results have shown that the absolute dose and relative dose distribution curves obtained from a GafChromic film can provide information on the value for acceptance. To conclude the GafChromic flim is a convenient and useful dosimetry tool for linac based radiosurgery.

Non-invasive hematocrit measurement (혈액중 non-invasive hematocrit 분석)

  • Yoon, Gil-Won;Jeon, Kye-Jin;Park, Kun-Kook;Lee, Jong-Youn;Hwang, Hyun-Tae;Yeo, Hyung-Seok;Kim, Hong-Sig
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2002.11a
    • /
    • pp.59-62
    • /
    • 2002
  • Wavelength selection and prediction algorithm for determining hematocrit are investigated. A model based on the difference in optical density induced by the pulsation of heart beat is developed by taking approximation of Twersky's theory on the assumption that the variation of blood vessel size is small during arterial pulsing[1]. A device is constructed with a five-wavelength LED array as light source. The selected wavelengths are two isobestic points and three in compensation for tissue scattering. Data are collected from 549 out-patients who are randomly grouped as calibration and prediction sets. The range of percent hematocrit was 19.3∼51.8. The ratio of the variations of optical density between systole and diastole at two different wavelengths is used as a variable. We selected several such variables that show high reproducibility among all variables. Multiple linear regression analysis is made. The relative percent error is 8% and the standard deviation is 3.67 for the calibration set. The relative % error and standard deviation of the prediction set are 8.2% and 3.69 respectively. We successfully demonstrate the possibility of non-invasive hematocrit measurement, particularly, using the wavelengths below 1000nm.

  • PDF

Anthocyanin Contents, Effective Components and Botanical Characteristics of the CNU Colored Rice Lines (유색미 CNU 육성계통에 대한 안토시안, 유효성분 및 주요 식물학적 특성)

  • Lee Hee-Bong;Kim Yong-Il;Park Bo-Young;Jung Jae-Young;Song Jae-Young;Choi Hyun-Gu;Kang Si-Yong;Kim Bo-Kyoung
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.50 no.spc1
    • /
    • pp.12-18
    • /
    • 2005
  • This study was carried out to evaluate anthocyanine contents, effective components and major botanical characteristics of the new developed colored rices. Characteristics of colored rice lines showed variation in culm length and spikelets per panicle in CNU39, panicle length in CNU43, 1,000 grain weight in CNU90, and yield per plant in CNU119 were highly compared to the Check, Heugjinjubyeo. Relative optical density(ROD) of Heugjinjubyeo was the highest at 530 nm, followed by CNU71, CNU73 and CNU119. The high peaks of ROD of Heugjinjubyeo and CNU71 appeared at 280 nm and 530 nm, and that of CNU43 appeared at 430 nm. The relative anthocyanin contents (RAC) per plant of the CU 71 among the new developed rice compared by yield per unit area was very high, fellowed by CNU73 and Heugjinjubyo.

Effect of Filler Addition on Properties of Sheets Prepared from Bacterial Cellulose (박테리아 셀룰로오스 시트의 물성에 미치는 충전제의 첨가효과)

  • 조남석;민두식
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.30 no.4
    • /
    • pp.35-41
    • /
    • 1998
  • The bacterial cellulose has many unique properties that are potentially and commercially beneficial. In order to make opaque product from this cellulose, filling properties by fillers should be known. This study was performed to investigate the effect of filler addition on physical properties of sheets from bacterial cellulose. The effect of filling on its optical properties was also discussed. The apparent density and internal bonding strength of bacterial cellulose sheet are decreasing with the increase of filler contents. Those adversely affect Young's modulus and physical property of the sheet, but these negative phenomena of the bacterial cellulose sheet by filler addition are not so sensitive compared to substantial decreasing of physical properties of ordinary hardwood KP. This strength decrease would be attributed to the decrease of relative bonding sites among pulp fibers. Concerned to optical properties, the bacterial cellulose sheet shows high increase of brightness and opacity according to filler loading, but no significant changes in porosity up to 17.3% loading because of fine and filamentous structure of bacterial cellulose fibers.

  • PDF

Effect of Tetracycline Analogues on The Activity of Matrix Metalloproteinase-3 in Gingival Fibroblasts (테트라사이클린계 약물이 치은섬유아세포내 MMP-3의 활성도에 미치는 영향)

  • Cho, Jong-Hee;Kim, Sang-Mok;Kim, Byung-Ock;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.3
    • /
    • pp.677-693
    • /
    • 1999
  • Extracellular matrix component is degraded by enzymes of thematrix metalloproteinases(MMPs). MMPs are produced by both hemopoietic and structural cells. Increased activity of MMP-3 in periodontium is strongly associated with inflammatory periodontal disease. The purpose of the present study was to determine the effect of tetracycline analogues on the activity of MMP-3. Tetracycline-HCl, doxycycline-HCl, and minocycline-HCl were applied to huamn gingival fibroblasts at various concentrations of 10, 25, 50, 100, 200${\mu}g$/ml, and 1 hour later IL-$1{\beta}$ of 25ng/ml was added. After incubation for 24 hours the cells were reacted by enzyme-linked immunosorbent assay using proMMP-3 ELISA kit. The optical density was measured by microwell plate reader at 450nm. The relative activity of MMP-3 was calculated as the percentage of the optical density of each experimental group to that of the control. The difference of the optical density and the relative activity of MMP-3 between the experimental groups and the control wasstatistically analyzed by one way ANOVA. The results were as follows: 1. Tetracycline-HCl showed the tendency to inhibit the activity of MMP-3 at the concentration lower than 25${\mu}g$/ml, but increased significantly the activity of MMP-3 at the concentration of 200${\mu}g$/ml(p<0.05). 2. Doxycycline-HCl inhibited significantly the activity of MMP-3 at the concentration lower than 100${\mu}g$/ml, but increased significantly the activity of MMP-3 at the concentration of 200${\mu}g$/ml(p<0.05). 3. Minocycline-HCl inhibited the activity of MMP-3 at the concentration in the range of 10 to 200${\mu}g$/ml. Within the limit of the present study, the above results suggested that the low concentration of tetracycline analogues could inhibit the activity of MMP-3 induced by IL-$1{\beta}$ in human gingival fibroblasts.

  • PDF

Properties of Indium Tin Oxide Multilayer Fabricated by Glancing Angle Deposition Method

  • Oh, Gyujin;Lee, Kyoung Su;Kim, Eun Kyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.367-367
    • /
    • 2013
  • Commercial applications of indium tin oxide (ITO) can be separated into two useful areas. As it is perceived to bear electrical properties and optical transparency at once, its chance to apply to promising fields, usually for an optical device, gets greater in the passing time. ITO is one of the transparent conducting oxides (TCO), and required to carry the relative resistance less than $10^{-3}{\Omega}$/cm and transmittances over 80 % in the visible wavelength of light. Because ITO has considerable refractive index, there exist applications for anti-reflection coatings. Anti-reflection properties require gradual change in refractive index from films to air. Such changes are obtained from film density or nano-clustered fractional void. Glancing angle deposition (GLAD) method is a well known process for adjusting nanostructure of the films. From its shadowing effects, GLAD helps to deposit well-controlled porous films effectively. In this study, we are comparing the reference sample to samples coated with controlled ITO multilayer accumulated by an e-beam evaporation system. At first, the single ITO layer samples are prepared to decide refractive index with ellipsometry. Afterwards, ITO multilayer samples are fabricated and fitted by multilayer ellipsometric model based on single layer data. The structural properties were measured by using atomic force microscopy (AFM), and by scanning X-ray diffraction (XRD) measurements. The ellipsometry was used to determine refractive indices and extinction coefficient. The optical transmittance of the film was investigated by using an ultraviolet-visible (UV-Vis) spectrophotometer.

  • PDF

Recent Progress of Nonpolar and Semipolar GaN on Sapphire Substrates for the Next Generation High Power Light Emitting Diodes

  • Lee, Seong-Nam
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.20.2-20.2
    • /
    • 2011
  • III-nitrides have attracted much attention for optoelectronic device applications whose emission wavelengths ranging from green to ultraviolet due to their wide band gap. However, due to the strong polarization properties of conventional c-plane III-nitrides, the built-in polarization-induced electric field limits the performance of optical devices. Therefore, there has been a renewed interest in the growth of nonpolar III-nitride semiconductors for polarization free heterostructure optoelectronic and electronic devices. However, the crystal and the optical quality of nonpolar/semipolar GaN have been poorer than those of conventional c-plane GaN, resulting in the relative poor optical and electrical properties of light emitting diodes (LEDs). In this presentation, I will discuss the growth and characterization of high quality nonpolar a-plane and semipolar (11-22) GaN and InGaN multiple quantum wells (MQWs) grown on r- and m-plane sapphire substrates, respectively, by using metalorganic chemical vapor deposition (MOCVD) without a low temperature GaN buffer layer. Especially, the epitaxial lateral overgrowth (ELO) technique will be also discussed to reduce the dislocation density and enhance the performance of nonpolar and semipolar GaN-based LEDs.

  • PDF

Case Study on Integrated In-line Oil Monitoring Sensor for Machine Condition Monitoring of Steel Making Industry (통합형 인-라인 오일 모니터링 센서의 제철설비 현장 적용사례)

  • Kong, H.;Han, H.G.;Kwak, J.S.;Chang, W.S.;Im, G.G.
    • Tribology and Lubricants
    • /
    • v.26 no.1
    • /
    • pp.73-77
    • /
    • 2010
  • One of the important trends for condition monitoring in the 21st century is the development of smart sensors that will permit the cost-effective continuous monitoring of key machine equipments. In this study, an integrated in-line oil monitoring sensor assigned for continuous in situ monitoring multiple parameters of oil performance is presented. The sensor estimates oil deterioration based on the information about chemical degradation, total contamination, water content of oil and oil temperature. The oil oxidation is estimated by "chromatic ratio", total contamination is measured by the changes in optical density of oil in three optical wave-bands ('Red', 'Green' and 'Blue') and water content is evaluated as relative saturation of oil by water. In order to evaluate the sensor's effectiveness, the sensor was applied to several used oil samples in steel making industry and the results were compared with those measured by standard test methods.