• Title/Summary/Keyword: relative angle

Search Result 806, Processing Time 0.023 seconds

A Study on 3-Dimensional Near-Field Source Localization Using Interference Pattern Matching in Shallow Water Environments (천해에서 간섭패턴 정합을 이용한 근거리 음원의 3차원 위치추정 기법연구)

  • Kim, Se-Young;Chun, Seung-Yong;Son, Yoon-Jun;Kim, Ki-Man
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.4
    • /
    • pp.318-327
    • /
    • 2009
  • In this paper, we propose a 3-D geometric localization method for near-field broadband source in shallow water environments. According to the waveguide invariant theory, slope of the interference pattern which is seen in a sensor spectrogram directly proportional to a range of the source. The relative ratio of the range between source and sensors was estimated by matching of two interference patterns in spectrogram. Then this ratio is applied to the Apollonius's circle which shows the locus of a source whose range ratio from two sensors is constant. Two Apollonius's circles from three sensors make the intersection point that means the horizontal range and the azimuth angle of the source. And this intersection point is constant with source depth. Therefore the source depth can be estimated using 3-D hyperboloid equation whose range difference from two sensors is constant. To evaluate a performance of the proposed localization algorithm, simulation is performed using acoustic propagation program and analysis of localization error is demonstrated. From simulation results, error estimate for range and depth is described within 50 m and 15 m respectively.

Role of TiO2 Decoration on SnO2 Nanorods for Highly Sensitive and Selective Acetone Detection (TiO2장식을 통한 SnO2 nanorods의 CH3COCH3 감지 특성 개선)

  • Ji-Hyeong Lee;Woon-Hyun Jo;Heewon Lim;Jae-Hwan So;Ha-gyeong Bae;Jae Han Chung;Young-Seok Shim
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.5
    • /
    • pp.318-325
    • /
    • 2024
  • In this study, we fabricated TiO2-decorated SnO2 nanorods (TSNRs) via glancing-angle deposition to achieve highly sensitive and selective CH3COCH3 detection. The gas-sensing properties of the TSNRs were systematically investigated, and the optimal sensing performance was achieved at 350℃ by 2-nm-thick TSNRs. When the sensors were exposed to 50 ppm of various gases (CH3COCH3, C2H5OH, C5H8, CH4, and CO), the 2-nm-thick TSNRs demonstrated a 4.6-fold increase in response (Ra/Rg-1=134) to CH3COCH3 compared with bare SnO2 nanorods (Ra/Rg-1=29.5) and exhibited excellent selectivity. In a high-humid environment (relative humidity = 80%), the 2-nm-thick TSNRs indicated a low theoretical detection limit of ≈5.31 ppb for CH3COCH3. These results suggest the significant potential of the proposed sensor for use in Internet-of-Things applications, particularly under extreme environmental conditions.

Optimization of the Flip Angle and Scan Timing in Hepatobiliary Phase Imaging Using T1-Weighted, CAIPIRINHA GRE Imaging

  • Kim, Jeongjae;Kim, Bong Soo;Lee, Jeong Sub;Woo, Seung Tae;Choi, Guk Myung;Kim, Seung Hyoung;Lee, Ho Kyu;Lee, Mu Sook;Lee, Kyung Ryeol;Park, Joon Hyuk
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • Purpose: This study was designed to optimize the flip angle (FA) and scan timing of the hepatobiliary phase (HBP) using the 3D T1-weighted, gradient-echo (GRE) imaging with controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) technique on gadoxetic acid-enhanced 3T liver MR imaging. Materials and Methods: Sixty-two patients who underwent gadoxetic acid-enhanced 3T liver MR imaging were included in this study. Four 3D T1-weighted GRE imaging studies using the CAIPIRINHA technique and FAs of $9^{\circ}$ and $13^{\circ}$ were acquired during HBP at 15 and 20 min after intravenous injection of gadoxetic acid. Two abdominal radiologists, who were blinded to the FA and the timing of image acquisition, assessed the sharpness of liver edge, hepatic vessel clarity, lesion conspicuity, artifact severity, and overall image quality using a five-point scale. Quantitative analysis was performed by another radiologist to estimate the relative liver enhancement (RLE) and the signal-to-noise ratio (SNR). Statistical analyses were performed using the Wilcoxon signed rank test and one-way analysis of variance. Results: The scores of the HBP with an FA of $13^{\circ}$ during the same delayed time were significantly higher than those of the HBP with an FA of $9^{\circ}$ in all the assessment items (P < 0.01). In terms of the delay time, images at the same FA obtained with a 20-min-HBP showed better quality than those obtained with a 15-min-HBP. There was no significant difference in qualitative scores between the 20-min-HBP and the 15-min-HBP images in the non-liver cirrhosis (LC) group except for the hepatic vessel clarity score with $9^{\circ}$ FA. In the quantitative analysis, a statistically significant difference was found in the degree of RLE in the four HBP images (P = 0.012). However, in the subgroup analysis, no significant difference in RLE was found in the four HBP images in either the LC or the non-LC groups. The SNR did not differ significantly in the four HBP images. In the subgroup analysis, 20-min-HBP imaging with a $13^{\circ}$ FA showed the highest SNR value in the LC-group, whereas 15-min-HBP imaging with a $13^{\circ}$ FA showed the best value of SNR in the non-LC group. Conclusion: The use of a moderately high FA improves the image quality and lesion conspicuity on 3D, T1-weighted GRE imaging using the CAIPIRINHA technique on gadoxetic acid, 3T liver MR imaging. In patients with normal liver function, the 15-min-HBP with a $13^{\circ}$ FA represents a feasible option without a significant decrease in image quality.

Evaluation of Magnetization Transfer Ratio Imaging by Phase Sensitive Method in Knee Joint (슬관절 부위에서 자화전이 위상감도법에 의한 자화전이율 영상 평가)

  • Yoon, Moon-Hyun;Seung, Mi-Sook;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.269-275
    • /
    • 2008
  • Although MR imaging is generally applicable to depict knee joint deterioration it, is sometimes occurred to mis-read and mis-diagnose the common knee joint diseases. In this study, we employed magnetization transfer ratio (MTR) method to improve the diagnosis of the various knee joint diseases. Spin-echo (SE) T2-weighted images (TR/TE 3,400-3,500/90-100 ms) were obtained in seven cases of knee joint deterioration, FSE T2-weighted images (TR/TE 4,500-5,000/100-108 ms) were obtained in seven cases of knee joint deterioration, gradient-echo (GRE) T2-weighted images (TR/TE 9/4.56/$50^{\circ}$ flip angle, NEX 1) were obtained in 3 cases of knee joint deterioration, In six cases of knee joint deterioration, fat suppression was performed using a T2-weighted short T1/tau inverse recovery (STIR) sequence (TR/TE =2,894-3,215 ms/70 ms, NEX 3, ETL 9). Calculation of MTR for individual pixels was performed on registration of unsaturated and saturated images. After processing to make MTR images, the images were displayed in gray color. For improving diagnosis, three-dimensional isotropic volume images, the MR tristimulus color mapping and the MTR map was employed. MTR images showed diagnostic images quality to assess the patients' pathologies. The intensity difference between MTR images and conventional MRI was seen on the color bar. The profile graph on MTR imaging effect showed a quantitative measure of the relative decrease in signal intensity due to the MT pulse. To diagnose the pathologies of the knee joint, the profile graph data was shown on the image as a small cross. The present study indicated that MTR images in the knee joint were feasible. Investigation of physical change on MTR imaging enables to provide us more insight in the physical and technical basis of MTR imaging. MTR images could be useful for rapid assessment of diseases that we examine unambiguous contrast in MT images of knee disorder patients.

  • PDF

Perfusion MR Imaging of the Brain Tumor: Preliminary Report (뇌종야의 관류 자기공명영상: 예비보고)

  • 김홍대;장기현;성수옥;한문희;한만청
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.119-124
    • /
    • 1997
  • Purpose: To assess the utility of magnetic resonance(MR) cerebral blood volume (CBV) map in the evaluation of brain tumors. Materials and Methods: We performed perfusion MR imaing preoperatively in the consecutive IS patients with intracranial masses(3 meningiomas, 2 glioblastoma multiformes, 3 low grade gliomas, 1 lymphoma, 1 germinoma, 1 neurocytoma, 1 metastasis, 2 abscesses, 1 radionecrosis). The average age of the patients was 42 years (22yr -68yr), composed of 10 males and S females. All MR images were obtained at l.ST imager(Signa, CE Medical Systems, Milwaukee, Wisconsin). The regional CBV map was obtained on the theoretical basis of susceptibility difference induced by first pass circulation of contrast media. (contrast media: IScc of gadopentate dimeglumine, about 2ml/sec by hand, starting at 10 second after first baseline scan). For each patient, a total of 480 images (6 slices, 80 images/slice in 160 sec) were obtained by using gradient echo(CE) single shot echo-planar image(EPI) sequence (TR 2000ms, TE SOms, flip angle $90^{\circ}$, FOV $240{\times}240mm,{\;}matrix{\;}128{\times}128$, slice-thick/gap S/2.S). After data collection, the raw data were transferred to CE workstation and rCBV maps were generated from the numerical integration of ${\Delta}R2^{*} on a voxel by voxel basis, with home made software (${\Delta}R2^{*}=-ln (S/SO)/TE). For easy visual interpretation, relative RCB color coding with reference to the normal white matter was applied and color rCBV maps were obtained. The findings of perfusion MR image were retrospectively correlated with Cd-enhanced images with focus on the degree and extent of perfusion and contrast enhancement. Results: Two cases of glioblastoma multiforme with rim enhancement on Cd-enhanced Tl weighted image showed increased perfusion in the peripheral rim and decreased perfusion in the central necrosis portion. The low grade gliomas appeared as a low perfusion area with poorly defined margin. In 2 cases of brain abscess, the degree of perfusion was similar to that of the normal white matter in the peripheral enhancing rim and was low in the central portion. All meningiomas showed diffuse homogeneous increased perfusion of moderate or high degree. One each of lymphoma and germinoma showed homogenously decreased perfusion with well defined margin. The central neurocytoma showed multifocal increased perfusion areas of moderate or high degree. A few nodules of the multiple metastasis showed increased perfusion of moderate degree. One radionecrosis revealed multiple foci of increased perfusion within the area of decreased perfusion. Conclusion: The rCBV map appears to correlate well with the perfusion state of brain tumor, and may be helpful in discrimination between low grade and high grade gliomas. The further study is needed to clarify the role of perfusion MR image in the evaluation of brain tumor.

  • PDF

Distributional Characteristics of Microcrack in Tertiary Crystalline Tuff from Northeastern Gyeongsang Basin (경상분지 북동부의 제3기 결정질 응회암에서 발달하는 미세균열의 분포특성)

  • Park, Deok-Won;Lee, Chang-Bum
    • The Journal of the Petrological Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.315-336
    • /
    • 2009
  • We have studied the orientational characteristics of microcrack frequency, it's length and density in Tertiary crystalline tuff from the northeastern part of the Gyeongsang Basin. 134 sets of microcracks on horizontal surfaces of 3 rock samples from Heunghae-eup were distinguished by enlarged photomicrographs of the thin sections. The variability in patterns among microcrack length-frequency histograms for three rock samples from different altitudes were derived. The pattern of histograms changes progressively from negative exponential form to log-normal form in proportion to altitude. The distribution pattern for rock sample no.1 from lower altitude shows the broad length distribution characterized by higher mean and median, and higher standard deviation. Meanwhile, this distribution pattern corresponds with characteristics of joint length distribution in sedimentary rocks of the lower part of the Gyeongsang Supergroup. The occurrence frequency of shorter microcracks increases toward both NW and NE directions from the $N0{\sim}10^{\circ}W$, with the dominant direction of $N80{\sim}90^{\circ}W$ and $N80{\sim}90^{\circ}E$, respectively. This distribution pattern represents the relative differences in formation timing among microcrack sets and the result of the new initiation of shorter microcracks. Meanwhile, the longest microcracks within $N60{\sim}70^{\circ}W$($L_{max}$:1.18 mm) and $N0{\sim}10^{\circ}W$($L_{max}$:0.80 mm) directions are seen, but this kind of microcracks are very limited in number. Whole domain of the directional angle($\theta$)-frequency(N), length(L) and density($\rho$) chart can be divided into five sections in terms of phases of the distribution of related curves. From the distribution chart, density curve shows five distinct peaks in the WNW-ESE($N70{\sim}80^{\circ}W$), NS~NNE-SSW($N0{\sim}10^{\circ}W$, $N10{\sim}20^{\circ}E$), ENE-WSW($N50{\sim}60^{\circ}E$), and nearly EW($N80{\sim}90^{\circ}E$) directions, respectively. Especially, main directions of faults correspond with the directional angle showing high density. Consequently, these distribution patterns of density curve reflect the representative maximum principal stress orientations suggested in previous studies.

Rietveld Structure Refinement of Biotite Using Neutron Powder Diffraction (중성자분말회절법을 이용한 흑운모의 Rietveld Structure Refinement)

  • 전철민;김신애;문희수
    • Economic and Environmental Geology
    • /
    • v.34 no.1
    • /
    • pp.1-12
    • /
    • 2001
  • The crystal structure of biotite-1M from Bancroft, Ontario, was determined by Rietveld refinement method using high-resolution neutron powder diffraction data at -26.3$^{\circ}C$, 2$0^{\circ}C$, 30$0^{\circ}C$, $600^{\circ}C$, 90$0^{\circ}C$. The crystal structure has been refined to a R sub(B) of 5.06%-11.9% and S (Goodness of fitness) of 2.97-3.94. The expansion rate of a, b, c unit cell dimensions with elevated temperature linearly increase to $600^{\circ}C$. The expansivity of the c dimension is $1.61{\times}10^{40}C^{-1}$, while $2.73{\times}10^{50}C^{-1}$ and $5.71{\times}10^{-50}C^{-1}$ for the a and b dimensions, respectively. Thus, the volume increase of the unit cell is dominated by expansion of the c axis as increasing temperature. In contrast to the trend, the expansivity of the dimensions is decreased at 90$0^{\circ}C$. It may be attributed to a change in cation size caused by dehydroxylation-oxidation of $Fe^{2+}$ to $Fe^{3+}$ in vacuum condition at such high temperature. The position of H-proton was determined by the refinement of diffraction pattern at low temperature (-2.63$^{\circ}C$). The position is 0.9103${\AA}$ from the O sub(4) location and located at atomic coordinates (x/a=0.138, y/b=0.5, z/c=0.305) with the OH vector almost normal to plane (001). According to the increase of the temperature, $\alpha$* (tetrahedral rotation angle), $t_{oct}$ (octahedral sheet thickness), mean distance increase except 90$0^{\circ}C$ data. But the trend is less clearly relative to unit cell dimension expansion because the expansion is dominant to the interlayer. Also, ${\Psi}$ (octahedral flattening angle) shows no trends as increasing temperature and it may be because the octahedron (M1, M2) is substituted by Mg and Fe.

  • PDF

The Three Dimensional Analysis on Nasal Airway Morphology in Class III Malocclusion (골격성 III급 부정교합자의 Nasal Airway 형태에 관한 3차원적 분석 연구)

  • Kim, Moon-Hwan;Lee, Jin-Woo;Cha, Kyung-Suk;Chung, Dong-Hwa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.389-403
    • /
    • 2008
  • In Angle's Class III malocclusion, which has higher incidence in Korean than Western, depressed midfacial profile with protruded lower lips and mandible may give rise to many functional, esthetic, psychological, social problems. Due to the different malocclusion incidence according to racial differences, many previous studies focused on the relationship between Class II malocclusion and nasal airway obstruction. Previous studies used lateral cephalography which has limitations of 2 dimensional image with projection error and identification error. Therefore, the purpose of this study was to analyze morphologic differences in the nasal airway between normal occlusion and Angle's Class III malocclusion patients using 3-dimensional facial computed tomography. Thirteen normal occlusion(7 men and 6 women) and sixteen skeletal Class III(7 men and 9 women) patients were selected and 3-dimensional facial computed tomography taking was performed. Comparison between two group in volume and sectional area of nasal airway were carried out. The results were followed. 1. In the comparison of absolute nasal airway volume, oropharyngeal space of experimental group were larger than control group but there are no significant difference in other. 2. In the comparison of relative nasal airway volume, oropharyngeal space of experimental group were larger than control group but there are no significant difference in other. 3. In the oropharyngeal space width on frontal and lateral view, the similar tendency was revealed between two groups. 4. In the lateral curvature of nasal airway, the similar tendency was revealed between two groups.

Selectivity and Permeability Characteristics of Pure CO2 and N2 Gases through Plasma Treated Polystyrene Membrane (플라즈마 처리된 폴리스티렌 막을 통한 순수한 CO2 와 N2 기체의 선택·투과 특성)

  • Hwang, Yui-Dong;Shin, Hee-Yong;Kwak, Hyun;Bae, Seong-Youl
    • Korean Chemical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.588-596
    • /
    • 2006
  • The surface of polystyrene membrane treated by Ar, $O_2$ plasma, and the effects were observed before and after the treatment and permeability of $CO_2$, $N_2$ and selectivity of $CO_2$ relative to $N_2$ was measured using continuous flow gas permeation analyzer (GPA). The mole ratio of O over C in the surface was increased from 0 to 0.179 with Ar plasma treatment and route mean square of surface was increased from $15.86{\AA}$ to $71.64{\AA}$. Therefore the contact angle was decreased from $89.16^{\circ}$ to $18.1^{\circ}$. Thus Plasma treatments made surface of membrane tend to be highly hydrophilic. The optimum condition for the $CO_2$ permeability and ideal selectivity of the plasma treated membrane was as follows: the measurement of Ar (60 W, 2 min, $70^{\circ}C$) plasma treatment was $1.14{\times}10^{-12}[m^3(STP){\cdot}m/m^2{\cdot}sec{\cdot}atm]$ and 4.22. In the case of $O_2$ plasma treatment, the contact angle was decreased at $13.56^{\circ}$ with increase of O/C ratio ($0.189{\AA}$) and route mean square of surface ($57.10{\AA}$). The optimum condition for the $CO_2$ permeability and ideal selectivity of the plasma treated membrane was as follows: the measurement of $O_2$ (90 W, 2 min, $70^{\circ}C$) plasma treatment was $7.1{\times}10^{-12}[m^3(STP){\cdot}m/m^2{\cdot}sec{\cdot}atm]$ and 11.5. After plasma treatment, the changes of membrane surface were all subtly linked with both cross-linking and etching effects. Finally, it was confirmed that the gas permeation capacity and selectivity of the modified membrane with plasma could be improved by an appropriate control of the plasma conditions such as treatment time, the power input and sort of plasma gas.

Estimating the Competition Indices and Diameter Growth of Individual Trees through Position-dependent Stand Survey (위치종속임분조사(位置從屬林分調査)에 의한 개체목(個體木)의 경쟁지수(競爭指數) 및 흉고직경생장(胸高直徑生長) 추정(推定))

  • Lee, Woo-Kyun
    • Journal of Korean Society of Forest Science
    • /
    • v.85 no.3
    • /
    • pp.539-551
    • /
    • 1996
  • In this study, a number of distance-dependent competition indices on tree-level which incorporate the tree sizes and distances to competitors, and traditional stand-level density measures were estimated from the data compiled with position-dependent survey in a Pinus densiflora stand. The performance of the estimated competition indices was examined by comparing the relationship with the diameter growth, and a dbh growth function, in which the competition index is considered as a one of influence factors, are developed. In the searching method of competing trees, the competition index estimated with $30^{\circ}$ competition interrupting angle showed the highest correlation with the annual dbh growth, while the expanding the competing zone distance had no significant effect on the performance of competition index in estimating annual dbh growth. The most of the examined stand-level competition indices, based on distance-dependent single-tree competition indices, were evaluated to describe similarly the stand competition status. As a result of partial correlation analysis in which the effect of age and site index are eliminated, Alemdag's mean competition index and relative spacing index were determined to have the highest correlation with dbh. The relative spacing index, which can be easily measured in field without measuring the position of individual trees, was considered to be a better suited one for estimating mean dbh of a stand. Among distance-dependent competition indices on tree-level, Hegyi's competition index showed the best performance in their correlation with annual dbh growth, if eliminated the effect of site index and dbh. This enabled to derive the following annual dbh growth function of individual trees which incorporate age, dominant height, dbh and Hegyi's competition index as influence factors : $$dbh^{\prime}=3.975362676{\cdot}age^{-1.099274613}{\cdot}ho^{0.199893990}{\cdot}dbh^{0.269430865}{\cdot}HgCI^{-0.353643587}$$ This function is coincided to the growth principle in which site index has a positive effect on the annual dbh growth, while high age or competition causes to reduce the annual dbh growth, and can be used as a function in single tree growth model.

  • PDF