• 제목/요약/키워드: reinforced concrete floor

검색결과 183건 처리시간 0.023초

역사적 도심 내 건축물의 이력을 통해 본 재생기법에 관한 연구 -청주시 남문로 2가동의 세장형 필지를 대상으로- (A Study on the Adaptive Reuse Techniques through the History of Buildings in the Historic Urban Area - Focused on the Deep and Narrow Lots of Nammun-ro 2Ga, Cheongju -)

  • 김태영
    • 한국농촌건축학회논문집
    • /
    • 제22권2호
    • /
    • pp.1-8
    • /
    • 2020
  • This study is intended to derive the adaptive reuse techniques through the history and aspects of new construction, extension, repair, and other works, limited to the deep and narrow lots facing Seongan-gil and Nammun-gil in Nammun-ro 2 ga of Cheongju, the historic urban area. The results are as follows. 1) In the case of newly built reinforced concrete buildings, the central part of the top floor of the residence or all floors are opened to the open space(void) to facilitate lighting and ventilation. This is developed as a convection phenomenon due to the temperature difference from the slits between buildings, which affects the entire air flow of the block. 2) The buildings of extension and repair are composed of two-story masonry or steel frame, both the front store facing the road and the house on the back, but it looks like one because it is in contact with each other. If only a small gap between the front and rear buildings is restored to an external space or a space equipped with sun light, a small breath can be provided in lighting and ventilation. 3) The existing two-story wooden stores and houses have lost their external space due to repairs. With minimal intervention to restore the small courtyard, slits, and space under the eaves, it will not only improve lighting and ventilation, but also create a unique appearance as a segment of the elongated store.

Evaluation of EC8 and TBEC design response spectra applied at a region in Turkey

  • Yusuf Guzel;Fidan Guzel
    • Earthquakes and Structures
    • /
    • 제25권3호
    • /
    • pp.199-208
    • /
    • 2023
  • Seismic performance analysis is one of the fundamental steps in the design of new or retrofitting buildings. In the seismic performance analysis, the adapted spectral acceleration curve for a given site mainly governs the seismic behavior of buildings. Since every soil site (class) has a different impact on the spectral accelerations of input motions, different spectral acceleration curves have to be involved for every soil class that the building is located on top of. Modern seismic design codes (e.g., Eurocode 8, EC8, or Turkish Building Earthquake Code, TBEC) provide design response spectra for all the soil classes to be used in the building design or retrofitting. This research aims to evaluate the EC8 and TBEC based design response spectra using the spectra of real earthquake input motions that occurred (and were recorded at only soil classes A, B and C, no recording is available at soil class D) in a specific area in Turkey. It also conducts response spectrum analyses of 5, 10 and 13 floor reinforced concrete building models under EC8, TBEC and actual spectral response curves. The results indicate that the EC8 and especially TBEC given design response spectra cannot be able to represent the mean actual spectral acceleration curves at soil classes A, B and C. This is particularly observed at periods higher than 0.3 s, 0.42 s and 0.55 s for the TBEC design response spectra, 0.54 s, 0.65 s and 0.84 s for the EC8 design response spectra at soil classes A, B and C, respectively. This is also reflected to the shear forces of three building models, as actual spectral acceleration curves lead to the highest shear forces, followed by the shear forces obtained from EC8 and, then, the TBEC design response spectra.

벽식구조물의 효율적인 연직진동해석 (Efficient Floor Vibration Analysis in A Shear Wall Building Structure)

  • 김현수;이동근
    • 한국지진공학회논문집
    • /
    • 제8권6호통권40호
    • /
    • pp.55-66
    • /
    • 2004
  • 현재 국내에서는 벽과 바닥판만으로 이루어진 벽식 구조형식의 아파트 건물이 많이 건설되고 있다. 아파트와 같은 주거구조물에서는 다양한 진동원에 의하여 진동이 발생하고 이러한 진동은 벽과 바닥판을 통하여 이웃한 세대 및 위, 아래층 세대로 전달되게 된다. 벽식구조물의 진동해석을 정확하게 수행하기 위해서는 벽과 바닥판을 많은 수의 유한요소로 세분한 모델을 사용하는 것이 필요하다. 그러나 아파트와 같은 벽식구조물 전체를 수많은 유한요소로 세분하여 모형화하면 막대한 해석시간과 컴퓨터 메모리가 필요하게 된다. 따라서 본 연구에서는 상당히 줄어든 해석시간과 컴퓨터 메모리를 사용하여 정확한 해석결과를 얻기 위하여 행렬응축기법으로 벽과 바닥판에 수직인 자유도만 가지는 효율적인 진동해석 모델을 제안한다. 벽식구조물에서 벽과 바닥에 수직인 자유도만을 남기고 나머지 자유도를 행렬응축기법을 통하여 한꺼번에 소거를 한다면 행렬응축과정에서 상당히 많은 양의 시간이 소요된다. 따라서 본 연구에서는 벽이나 바닥판에 수직인 자유도만을 가진 수퍼요소를 생성한 후 이를 조합하여 한 층을 나타내는 부분구조를 만들고 최종적으로 부분구조를 조합하여 전체 구조물을 구성하는 모형화 기법을 제안하였다. 제안된 해석기법의 정확성과 효율성을 검증하기 위하여 3층 및 5층의 벽식구조물을 예제구조물로 사용하여 동적해석을 수행하였다. 예제해석 결과 제안된 해석방법의 결과는 절점당 6개의 자유도를 모두 사용한 해석모델의 결과와 비슷한 정확성을 보이면서도 소요되는 해석시간과 컴퓨터 메모리를 대폭 줄일 수 있었다.

내부충진을 통한 벨크로 보강재의 성능향상에 대한 실험적 연구 (Experimental Study on the Performance Improvement of Velcro Reinforcement through Internal Filling)

  • 정영석;권민호;김진섭;남광식
    • 대한토목학회논문집
    • /
    • 제41권4호
    • /
    • pp.347-355
    • /
    • 2021
  • 다층 구조물의 경우 1층이 연약한 경우 지진 시 1층에 변형이 집중되어 기둥 부재에 심각한 손상이 발생하거나 파괴되어 구조물이 붕괴하는 사례가 발생하게 된다. 국내의 경우 포항지진 당시 필로티 구조물의 손상사례를 예로 들 수 있다. 2016년 국립재난 안전연구원의 "국내 비내진 건축물의 내진보강공법 조사 및 소요비용 분석 연구"에 따르면 민간 철근콘크리트조 건축물 중 주택의 내진화 비율은 38.3 %고, 그 중 2층 구조물 7.1 %에서 6층 96.3 % 그 외 99.4 %로 2~5층 구조물의 경우 내진비율이 50 %이하로 저조한 것으로 보고하였다. 이에 정부는 지원사업을 통해서 내진화율을 개선코자 하고있으나, 종래의 보강법은 여전히 시공비용이 고가이고 긴급시공이 어려운 단점이 있다. 따라서 본 연구에서는 2014년 국토교통부의 연구사업을 통해서 개발된 저렴하고 긴급시공이 가능한 벨크로를 사용한 내진보강법의 성능을 개선하고자 벨크로와 콘크리트 기둥 사이에 고발포의 경질 우레탄 내부 충진을 통해서 벨크로의 초기긴장력을 도입하고, 이를 통해서 콘크리트 구속효과에 따른 벨크로의 연성보강성능 개선을 목표로 이를 평가하기 위한 실험을 수행하였다. 시험체의 최대 연성도를 통한 평가에서 벨크로 내진 보강재의 최대 연성도 증진 효과를 재확인할 수 있었다. 에너지 소산 능력을 통한 평가에서는 VELCRO1 대비 VELCRO2 눈에 띄는 개선을 보인 반면, VELCRO1와 VELCRO2 시험체의 최대 연성도는 큰 차이를 보이지 않았다. 결과적으로 충진재가 사용된 VELCRO2 시험체에서 에너지 소산 능력은 크게 증진되었으나, 최대 연성도 평가에서 최대변위(∆max)의 증가가 크지 않은 것을 확인하였다. 따라서 내부 충진재 재료의 개선과 균일한 충진재 시공을 개선의 필요성이 확인되었다.

군 복지시설의 지열시스템과 태양열시스템 경제성 평가 사례 연구 (A Case Study on Economic Analysis of a Solar Water Heating System and a Ground Source Heat Pump System Applied to a Military Building)

  • 이종찬;박용호;이강;이상호
    • 한국건설관리학회논문집
    • /
    • 제10권4호
    • /
    • pp.111-118
    • /
    • 2009
  • 본 연구는 군 복지시설인 육군 OO회관에 신 재생에너지 중 태양열 및 지열시스템을 적용했을 때, 각각의 효율성과 경제성을 분석하여 그 성능을 평가하였다. 연구 대상 건물은 철근콘크리트구조로서 건물 규모가 지하 1층 지상 3층이며 연면적이 약 2,917$m^2$인 건물이다. 건물의 용도는 목욕탕, 식당, 객실 및 사무실이며, 연간 냉 난방 에너지 소비량 판단 및 분석을 위해 e-Quest 시뮬레이션을 이용하였다. 신 재생에너지 적용에 대한 경제성 평가는 RETScreen 시스템을 이용하였다. 단, 신 재생에너지 시스템 사용은 연구대상 건물을 표준공사비로 판단했을 때 공사비의 5% 범위내로 한정하였다. 신 재생 에너지시스템 적용시 태양열시스템은 급탕용으로, 지열시스템은 냉방용으로 하였다. 연구결과 태양열시스템이 지열시스템보다 효과적이었다. 지열시스템은 투자비 상환시점이 약 16년 6개월 이후인 반면, 태양열시스템은 약 3년 11개월 이후에 가능한 것으로 판단되었다. 향후 화석에너지의 고갈과 지구온난화 등의 문제 해결을 위한 방안으로서 신 재생에너지의 이용 확대가 예상되며, 이에 군에서도 안정적인 에너지 수급을 위해 지속적인 발전이 되길 기원한다.

전북 지역 학교급식소의 시설.설비 및 물리적 환경에 대한 연구 (A Study on Foodservice Facilities, Utilities, and Physical Environment in the Chonbuk Area of Korea)

  • 국숙자;최병숙;노정옥
    • 한국식품영양학회지
    • /
    • 제22권4호
    • /
    • pp.497-507
    • /
    • 2009
  • The principal objective of this study was to assess the situation of foodservice facilities, utilities, and physical environment in the Chonbuk area. Self-administered questionnaires were collected from 252 nutrition teachers and school dietitians. Statistical data analysis was completed using the SPSS v. 11.5 program. The results were summarized as follows: Approximately 99.2% of the subjects were women 76.6% were married, over 87% were between the ages of 30 and 40(p<0.01) and 56.8% had more than 11 years of experience(p<0.001). Among the 252 school foodservice systems evaluated, 51.6% of the schools were located in urban areas and 48.0% were in rural areas(p<0.01). Approximately 68.0% of the schools prepared meals in the conventional way, and 32.3% prepared them in the commissary way(p<0.001). The number of employees at each institution was separated into the following categories: 1 to 3(37.7%), 4 to 6(27.8%), and 7 to 9(25.4%, p<0.01). Approximately 54.0% of schools had been running a school meal service for longer than 11 years(p<0.001). However, 67.5% of those facilities had not been remodeled since the initial implementation of foodservices. Approximately 94.0% of the school foodservice facilities were located on the first floor. 72.2% among them were constructed of reinforced concrete and 16.7% were prefabricated(p<0.001). As the result of our evaluation of related physical evidence and the atmosphere of the space, the average importance grade was $4.41{\pm}0.46$, and the average performance grade was $2.78{\pm}0.67$. Most nutrition teachers and school dietitians in elementary, middle, & high schools responded that the related physical evidence and the atmosphere of the space in school foodservice facilities were important, but the satisfaction level among the nutrition teachers and school dietitians was quite low. Therefore, it's important and necessary to analyze the opinions of the stakeholders in the foodservice industry prior to the remodeling of school foodservice facilities and utilities.

초고층건물의 성능평가를 위한 응답의존 시스템판별 및 모델향상 (Output-Only System Identification and Model Updating for Performance Evaluation of Tall Buildings)

  • 조순호
    • 한국지진공학회논문집
    • /
    • 제12권4호
    • /
    • pp.19-33
    • /
    • 2008
  • 구조물에 고유한 진동수,모드형태 및 감쇠비 등과 같은 동적성능치를 추출하기 위하여 25층 및 42층 건물에 대하여 자연진동에 의한 동적계측실험을 수행하였다. 고려된 건물은 주요 횡하중 지지기구로서 코아벽체 혹은 전단벽체가 추가된 철근콘크리트건물이며, 입면 혹은 평면상으로 골조가 혼합된 구조형식을 나타낸다. 특히, 25층 건물은 측면에 위치한 코아벽체 이외에 상부로부터 내려오는 전단벽 구조가 4층 바닥이하에서 골조형식으로 전환되는 복잡한 구조이다. 이와 같은 이유 및 건물 주방향의 유사한 강성배치로 매우 근접하고 혼합된 모드형태가 예상되어 시스템판별 시 어려움이 예상된다. 현재까지 개발된 다양한 시스템판별법을 대상건물의 자연진동 실측기록에 적용하여 모달계수를 유도하였으며, 그 결과를 비교 분석하였다. 3개의 주파수영역 및 4개의 시간영역에 근거한 응답의존 시스템판별법이 고려되었다. 서로 다른 시스템판별법에 의하여 추출된 고유진동수 및 감쇠비는 대체로 상당한 일치를 보였으나, 모드형태는 사용된 방법에 따라 정도가 다르게 불일치를 나타냈다. 실험으로부터 추출한 성능치와 초기 유한요소해석 값을 비교해 본 결과 대상건물 모두 적어도 저차 3개의 고유진동수에서 2배 정도의 차이를 나타냈다. 실험과 해석결과의 일치를 위하여 몇몇 수동모델향상이 시도되었으며, 허용할 만한 결과를 획득하였다. 사용된 시스템판별법에 대하여 각자의 장, 단점에 대하여 기술하였으며, 본 연구와 같은 실제 대형구조물에 대하여 자동모델향상기법을 적용할 시 예상되는 문제점에 대하여 토의하였다.

국내 냉장냉동 창고 현황 조사 (Investigation of Domestic Refrigeration and Freezing Warehouses)

  • 선일석
    • 유통과학연구
    • /
    • 제6권2호
    • /
    • pp.5-19
    • /
    • 2008
  • 본 연구에서는 냉장, 냉동 창고의 기초 자료가 부족하여, 불완전하기 때문에 이러한 기초자료를 제공하기 위하여 냉장 냉동 창고의 일반현황을 제시하는 데 목적이 있다. 조사내용은 냉장 냉동 창고의 일반적인 현황으로는 매출액, 자본금(출자금), 창고종류별 보유현황, 보관면적, 냉장냉동 시설용량 등과 설비현황으로는 랙의 유무, 건축물 구조 및 층고, 모유설비현황 등을 조사하였다. 조사결과에 따르면 지역별 분포는 수도권과 부산지역이 전체의 86.7%로 대부분을 차지하였으며 이들 지역이 평균보관면적 또한 큰 것으로 나타났다. 또한 전체 업체의 80%이상이 보세장치장을 보유하고 있는 것으로 조사되었으며, 냉장 냉동 창고의 면적 및 용량은 고른 분포를 보였다. 건축물 구조는 철근 콘크리트 구조가 대부분이었으며 설비의 경우 랙 설치 업체가 전체의 25%로 나타나 설치율이 낮았으며 랙의 설치여부와 자본금 및 매출액 규모와는 통계적 유의성을 보이지 않았다. 또한 보유설비는 화물용 승강기, 정보시스템, 도크 순이었으며 하역장비로는 지게차가 평균 9.1대, 리치스태커는 평균 2.2대 인 것으로 조사되었다. 본 조사가 국내 냉장 냉동 산업의 실태파악과 예측, 발전에 기초가 될 것으로 생각하며 향후 좀 더 세밀한 연구가 추가적으로 진행되어야 할 것이다.

  • PDF

수직증축형 공동주택 리모델링 구조해석을 위한 PC말뚝 강성에 관한 연구 (A Study of Prestressed Concrete Pile Stiffness for Structural Analysis of Condominium Remodeling with Vertical Story Extension)

  • 최창호;이현지;최기선;유영찬;김진영
    • 한국지반공학회논문집
    • /
    • 제33권12호
    • /
    • pp.81-92
    • /
    • 2017
  • 2013년 주택법 개정에 따라 최대 3개층까지 공동주택의 수직증축 리모델링 사업이 가능해졌다. 수직증축 리모델링은 추가하중으로 인한 구조 안전성 및 강화된 내진기준을 만족해야 하므로 기초보강을 필요로 하며, 말뚝 보강설계에서는 기존 말뚝과 보강 말뚝의 하중분담을 고려해야 한다. 말뚝의 하중분담을 계산하기 위해서는 말뚝의 수직 강성($K_v$)이 필요하지만, 20~30년 전에 설치된 PC 말뚝 강성에 대한 연구는 매우 미미한 실정이다. 본 논문에서는 1990년대 아파트 신축시 수행된 38건의 현장 말뚝재하 시험 결과를 검토하여, 직경 및 길이의 변화에 따른 PC말뚝의 강성을 분석하였다. 분석 결과 말뚝강성은 장경비(L/D)가 증가함에 따라 감소하는 것으로 나타났다. 또한, 현장 말뚝재하 시험결과를 도로교설계기준해설(2008) 및 한국철도시설공단 말뚝기초의 설계(2012)에서 제안하고 있는 말뚝강성 산정을 위한 계수 'a'와 비교하였다. 비교결과 10

학교시설 건설공사의 작업분류체계 구축 및 단위작업별 선후행 관계 분석 (Development of Work Breakdown Structure and Analysis of Precedence Relations by Activity in School Facilities Construction Work)

  • 방종대;손정락
    • 토지주택연구
    • /
    • 제8권3호
    • /
    • pp.189-200
    • /
    • 2017
  • The work breakdown structure and the precedence relations by work activity are very important because they are the basic data for estimating the construction duration in the construction work. However, there is no standard to accurately estimate the construction duration since the size of the school facilities construction is smaller than the general construction work. Therefore, some schools are unable to open in March or September and the delay of the construction duration can cause damage to the students. To solve this problem, this study developed a work breakdown structure of school facilities construction work and analyzed the precedence relations by work activities. The work breakdown structure of the school facilities construction is composed of three steps. The operations corresponding to level 1 and level 2 are as follows. (1) 2 preparatory work categories; preparation period and temporary construction. (2) 17 architectural work categories; temporary construction, foundation & pile work, reinforced concrete work, steel roof work, brick work, plaster work, tile work, stone work, waterproof construction, wood work, interior construction, floor work, metal work, roof work, windows construction, glazing work and paint construction. (3) 7 mechanic and fire work categories; outside trunk line work, plumbing work, air-conditioning equipment work, machine room work, city gas plumbing work, sanitation facilities and inspection & test working. (4) 4 civil work categories; wastewater work, drainage work, pavement work and other work. (5) 1 landscaping work categories; planting work. The work breakdown structure was derived from interviews with experts based on the milestones and detailed statements of existing school facilities. The analysis of precedence relations by school facilities work activity utilized PDM(Precedence Diagramming Method)which does not need a dummy and the relations were applied using FS(Finish to Start), FF(Finish to Finish), SS(Start to Start), SF(Start to Finish). The analysis of this study shows that if one work activity is delayed, the entire construction duration may be delayed because the majority of the works are FS relations. Therefore, it is necessary to use the Lag at the appropriate time to estimate the standard construction duration of the school facility construction. Lag is a term used only in the PDM method and it is used to define the relationship between the predecessor and the successor in creating the network milestone. And it means the delay time applied to the two work activities. The results of this study can reasonably estimate the standard construction duration of school facilities and it will contribute to the quality of the school facilities construction.