• Title/Summary/Keyword: reinforced columns

Search Result 1,121, Processing Time 0.024 seconds

Experimental study and modeling of masonry-infilled concrete frames with and without CFRP jacketing

  • Huang, Chao-Hsun;Sung, Yu-Chi;Tsai, Chi-Hsin
    • Structural Engineering and Mechanics
    • /
    • v.22 no.4
    • /
    • pp.449-467
    • /
    • 2006
  • Most existing concrete structures in Taiwan are considered nonductile due to insufficient transverse reinforcement and poor detailing of frame elements. Such features are fairly typical for buildings constructed prior to 1997, at which time the local building code was revised based on ACI 318-95. Among these structures, many contain perimeter or partition walls made of concrete or clay brick for architectural purposes. These walls, though treated as non-structural components in common design practice, could affect the structural behavior of the buildings during an earthquake. To study the behavior of such structures under seismic load, experiments were conducted on concrete frames of various configurations to show the force-deformation relationships, damage patterns, and other characteristics of the frames. For further interest, similar units with columns jacketed by carbon-fiber-reinforced-polymer (CFRP) were also tested to illustrate the effectiveness of this technique in the retrofit of concrete frames.

Stress Analysis of Semi-Rigid Frame (부분 강절 골조의 응력 해석)

  • 김선혜;김순철;이수곤
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.10a
    • /
    • pp.306-313
    • /
    • 1998
  • Contrary to reinforced concrete frames, the beams or girders found in actual steel frames are neither hinged nor fixed at their ends. Instead, they are usually restrained by the columns to which they are attached. Here in this paper, common finite element program for plane frame stress analysis is improved by including the effect of partial fixities of the girder ends. To include the effect of partial fixities of the girder ends, Kim's modified slope-deflection equation is adopted. The stress analysis results obtained by this proposed method are then compared with Kim's example. Finally, method of choosing the most economic girder section for a multi-story frame is suggested through the examples.

  • PDF

Buckling of T-Shaped Composite Columns (T형 복합재료 기둥의 좌굴)

  • Lee Seungsik;Back Sung-Yong
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.1 s.32
    • /
    • pp.57-62
    • /
    • 2006
  • Composite thin-walled members for civil engineering application are mainly produced by pultrusion technique, and they are generally made of a polymeric resin system reinforced by E-glass fibers due to economical reason. This material combination results in low elastic moduli of the composite materials and makes the design of composite members to be governed by stability limit state. Therefore the buckling behavior of composite thin-walled members was experimentally investigated in the present study. Axial compression was applied on each specimens by a hydraulic ram and knife edge fixtures were placed at both ends to simulate simple boundary condition. Axial compression, lateral displacements and twisting at the mid-height of each specimen were measured by a set of transducers during buckling test. The experimental buckling loads were compared with analytical results obtained through isotropic formulas. In the calculation of analytical results, elastic properties such as Young's modulus(E) and shear modulus(G) were replaced with EL and GLT obtained from coupon tests, respectively.

Seismic Capacity Design and Retrofit of Reinforced Concrete Staggered Wall Structures

  • Kim, Jinkoo;Choi, Younghoo
    • International Journal of Concrete Structures and Materials
    • /
    • v.11 no.2
    • /
    • pp.285-300
    • /
    • 2017
  • This study investigates the seismic performance of a staggered wall structure designed with conventional strength based design, and compares it with the performance of the structure designed by capacity design procedure which ensures strong column-weak beam concept. Then the seismic reinforcement schemes such as addition of interior columns or insertion of rotational friction dampers at the ends of connecting beams are validated by comparing their seismic performances with those of the standard model structure. Fragility analysis shows that the probability to reach the dynamic instability is highest in the strength designed structure and is lowest in the structure with friction dampers. It is also observed that, at least for the specific model structures considered in this study, R factor of 5.0 can be used in the seismic design of staggered wall structures with proposed retrofit schemes, while R factor of 3.0 may be reasonable for standard staggered wall structures.

Analytical Study on Inelastic Behavior and Ductility Capacity of Reinforced Concerte Bridge Columns Subjected to Seismic Load (지진하중을 받는 철근콘크리트 교각의 비탄성 거동 및 연성능력에 관한 해석적 연구)

  • 김태훈;유영화;신현목
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.4
    • /
    • pp.37-51
    • /
    • 2000
  • 이 연구는 지진 시 철근콘크리트 교각의 비탄성 거동 및 연성능력을 해석적으로 파악하는데 그 목적이 있다. 재료적 비선형성에 대해서는 균열 콘크리트에 대한 인장, 압축, 전단모델과 콘크리트 속에 있는 철근 모델을 조합하여 고려하였다. 이에 대한 콘크리트의 균열 모델로서의 분산균열모델을 사용하였다. 두께가 서로 다른 부재간의 접합부에 단면강성이 급변하기 때문에 생기는 국소적인 불연속변형을 고려하기 위한 경계면 요소를 도입하였다. 또한, 축방향철근의 유무 및 그 양 등에 따른 구속효과를 적절히 표현할 수 있는 해석 모델을 개발하였다. 본 연구에서는 철근콘크리트 교각의 비탄성 거동 및 연성 능력의 파악을 위해 제안한 해석기법을 신뢰성 있는 연구자의 실험결과와 비교하여 그 타당성을 검증하였다.

  • PDF

Structural behaviors of sustainable hybrid columns under compression and flexure

  • Wu, Xiang-Guo;Hu, Qiong;Zou, Ruofei;Zhao, Xinyu;Yu, Qun
    • Structural Engineering and Mechanics
    • /
    • v.52 no.5
    • /
    • pp.857-873
    • /
    • 2014
  • Structural behaviors of a sustainable hybrid column with the ultra high performance cementitious composites (UHPCC) permanent form under compression and flexure were studied. Critical state and failure stage characters are analyzed for large and small eccentricity cases. A simplified theoretical model is proposed for engineering designs and unified formulas for loading capacity of the hybrid column under compression and flexure loads are derived, including axial force and moment. Non-linear numerical analysis is carried out to verify the theoretical predictions. The theoretical predictions agree well with the numerical results which are verified by the short hybrid column tests recursively. Compared with the traditional reinforced concrete (RC) column, the loading capacity of the sustainable hybrid column is improved significantly due to UHPCC confinements.

A parametric study of optimum tall piers for railway bridge viaducts

  • Martinez-Martin, Francisco J.;Gonzalez-Vidosa, Fernando;Hospitaler, Antonio;Yepes, Victor
    • Structural Engineering and Mechanics
    • /
    • v.45 no.6
    • /
    • pp.723-740
    • /
    • 2013
  • This paper presents a parametric study of reinforced concrete bridge tall piers with hollow, rectangular sections. Such piers are typically used in railway construction of prestressed concrete viaducts. Twenty one different piers have been studied with seven column heights of 40, 50, 60, 70, 80, 90 and 100 m and three types of 10-span continuous viaducts, whose main span lengths are 40, 50 and 60 m. The piers studied are intermediate columns placed in the middle of the viaducts. The total number of optimization design variables varies from 139 for piers with column height of 40 m to 307 for piers with column height of 100 m. Further, the results presented are of much value for the preliminary design of the piers of prestressed concrete viaducts of high speed railway lines.

comparative Study on confinement Steel Amount of RC Column Bent (철근콘크리트 교각 심부구속철근량의 비교연구)

  • 이재훈
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.04a
    • /
    • pp.239-246
    • /
    • 1999
  • recently there have been many destructive seismic events in Kobe Japan in 1995 and in Northridge California USA in 1994. etc. The Korean Bridge Design Standard Specifications adopted the seismic design requirements in 1992. Comparing the earthquake magnitude in Korea with those in the west coast of the USA it may be said that the current seismic design requirements of the Korean Bridge Design Standard Specifications provides too conservation design results especially for transverse reinforcement details and amount in reinforced concrete columns. This fact usually makes construction problems in concrete casting due to transverse reinforcement congestion. And the effective stiffness Ieff depends on the axial load P(Ag{{{{ {f }_{ck } }}) and the longitudinal reinforcement ratio Ast/Ag and it is conservative to use the effective stiffness Ieff than the gross section moment Ig. Seismic design for transverse reinforcement content of concrete column is considered of extreme-fiber compression strain R-factor axial load and stiffness etc.

  • PDF

Theoretical study of UHPCC composite column behaviors under axial compression

  • Wu, Xiang-Guo;Zou, Ruofei;Zhao, Xinyu;Yu, Qun
    • Structural Engineering and Mechanics
    • /
    • v.55 no.5
    • /
    • pp.931-951
    • /
    • 2015
  • To improve the durability and service life of reinforced concrete column such as bridge piers, an advanced composite column made of Ultra High Performance Cementitious Composites (UHPCC) permanent form is proposed. Based on elasticity plasticity theory, axial compression behavior of the composite column was studied theoretically. The first circumferential cracking load and ultimate limit loading capacity are derived for the composite column. Short composite column compression tests and numerical simulations using FEM method were carried out to justify the theoretical formula. The effects of UHPCC tube thickness on the axial compression behavior were studied. Using the established theoretical model and numerical simulation, the large dimension composite columns are calculated and analyzed with different UHPCC tube thickness. These studies may provide a reference for advanced composite column design and application.

Vulnerability assessment and retrofit solutions of precast industrial structures

  • Belleri, Andrea;Torquati, Mauro;Riva, Paolo;Nascimbene, Roberto
    • Earthquakes and Structures
    • /
    • v.8 no.3
    • /
    • pp.801-820
    • /
    • 2015
  • The seismic sequence which hit the Northern Italian territory in 2012 produced extensive damage to reinforced concrete (RC) precast buildings typically adopted as industrial facilities. The considered damaged buildings are constituted by one-storey precast structures with RC columns connected to the ground by means of isolated socket foundations. The roof structural layout is composed of pre-stressed RC beams supporting pre-stressed RC floor elements, both designed as simply supported beams. The observed damage pattern, already highlighted in previous earthquakes, is mainly related to insufficient connection strength and ductility or to the absence of mechanical devices, being the connections designed neglecting seismic loads or neglecting displacement and rotation compatibility between adjacent elements. Following the vulnerabilities emerged in past seismic events, the paper investigates the seismic performance of industrial facilities typical of the Italian territory. The European building code seismic assessment methodologies are presented and discussed, as well as the retrofit interventions required to achieve an appropriate level of seismic capacity. The assessment procedure and retrofit solutions are applied to a selected case study.