• Title/Summary/Keyword: reinforced columns

Search Result 1,121, Processing Time 0.031 seconds

A Study on the Evaluation of Residual Strength of Double Concrete Filled Tube Column by Unstressed test (비재하 가열실험을 통한 이중강관 CFT기둥의 잔존강도 평가연구)

  • Kim, Sun-Hee;Won, Yong-An;Choi, Sung-Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.1
    • /
    • pp.81-89
    • /
    • 2012
  • The concrete-filled tubular square column is superior to steel frame column in terms of fire resistance because of the thermal storage provided by the concrete. Studies have been conducted on CFT column reinforcement with steel bars or with the use of an internal tube to improve its structural load capacity and fire resistance. In fact, reinforced CFT columns have been increasingly used to deal with high axial force. The functional deterioration of columns due to fire damage needs to be measured precisely. In this study, the temperature distribution inside the columns in case of a fire was evaluated and the degree of deterioration in the load capacity of the concrete and reinforcing members associated with temperature distribution was identified in order to evaluate the overall residual strength of the columns.

Finite Element Analysis of Reinforced Concrete Hollow Columns Using Path-dependent Volume Control Method (경로의존형 체적제어법을 이용한 철근콘크리트 중공 기둥의 유한요소해석)

  • Song, Ha-Won;Nam, Sang-Hyeok;Lim, Sang-Mook
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.3
    • /
    • pp.341-350
    • /
    • 2007
  • The volume control method which utilize a pressure node added into a finite shell element can overcome the drawbacks of conventional load control method and displacement control method. In this study, an improved volume control method is introduced for effective analysis of path-dependent behaviors of RC columns subjected to lateral cyclic loading or reversed cyclic loading along with compressive loading. RC shell structures and RC hollow columns are analyzed by discretizing the structures with layered shell elements and by applying in-plane two dimensional constitutive equations for concrete layers and reinforcement layers of the shell elements. The so-called path dependent volume control method as a finite element analysis technique is verified by comparing analysis results with other data including experimental results. The validity and applicability of the modeling technique is also confirmed by the comparison.

Displacement Ductility Evaluation of Earthquake Experienced RC Bridge Piers with 2.5 Aspect Ratio (지진을 경험한 형상비 2.5 RC 교각의 내진 변위 연성도 평가)

  • 정영수;박창규;이은희
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.3
    • /
    • pp.79-88
    • /
    • 2003
  • For the construction of PC bridge piers the implementation of 1992 seismic provisions, longitudinal steels were practically lap-spliced in the plastic hinge region. Experimental investigation was conducted ductility of evaluate the seismic earthquake-experienced reinforced concrete columns with 2,5 aspect ratio. Six test specimens were mode with test parameters: confinement ratios, lap splices, and retrofitting FRP materials. They were damaged under series of artificial earthquakes that could be compatible in Korean peninsula. Directly after the pseudo-dynamic test, damaged columns were retested under inelastic reversal cyclic loading simultaneously under a constant axial load, P=0.1f$\_$ck/A$\_$g/. Residual seismic performance of damaged columns was evaluated and compared to that of the corresponding original columns. Test results show that PC bridge piers with lap-spliced longitudinal steels appeared to fail at low ductility. This was due to the debonding of the lap splice, which resulted from insufficient development of the longitudinal steels. The specimens externally wrapped with composite FRP straps in the potential plastic hinge region indicated significant improvement both in flexural strength and displacement ductility.

Effect of tension stiffening on the behaviour of square RC column under torsion

  • Mondal, T. Ghosh;Prakash, S. Suriya
    • Structural Engineering and Mechanics
    • /
    • v.54 no.3
    • /
    • pp.501-520
    • /
    • 2015
  • Presence of torsional loadings can significantly affect the flow of internal forces and deformation capacity of reinforced concrete (RC) columns. It increases the possibility of brittle shear failure leading to catastrophic collapse of structural members. This necessitates accurate prediction of the torsional behaviour of RC members for their safe design. However, a review of previously published studies indicates that the torsional behaviour of RC members has not been studied in as much depth as the behaviour under flexure and shear in spite of its frequent occurrence in bridge columns. Very few analytical models are available to predict the response of RC members under torsional loads. Softened truss model (STM) developed in the University of Houston is one of them, which is widely used for this purpose. The present study shows that STM prediction is not sufficiently accurate particularly in the post cracking region when compared to test results. An improved analytical model for RC square columns subjected to torsion with and without axial compression is developed. Since concrete is weak in tension, its contribution to torsional capacity of RC members was neglected in the original STM. The present investigation revealed that, disregard to tensile strength of concrete is the main reason behind the discrepancies in the STM predictions. The existing STM is extended in this paper to include the effect of tension stiffening for better prediction of behaviour of square RC columns under torsion. Three different tension stiffening models comprising a linear, a quadratic and an exponential relationship have been considered in this study. The predictions of these models are validated through comparison with test data on local and global behaviour. It was observed that tension stiffening has significant influence on torsional behaviour of square RC members. The exponential and parabolic tension stiffening models were found to yield the most accurate predictions.

Influence of Anchorage of T-Plate on the Seismic Performance of RC Columns Strengthened with Unbounded Wire Rope Units (와이어로프 기반 비부착 보강된 RC 기둥의 내진거동에 대한 T형 강판 정착의 영향)

  • Sim, Jae-Il;Yang, Keun-Hyeok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.1
    • /
    • pp.133-140
    • /
    • 2010
  • Five strengthened columns and an unstrengthened column were tested under constant axial load and cyclic lateral loads to examine the seismic performance of the unbounded strengthening procedure using wire ropes and T-plates. Main variables considered were the presence of mortar cover for strengthening steel element and anchorage method of T-plate. Test results clearly showed that T-plates having a proper anchorage contribute to transfer of applied moment as well as enhancement of ductility of reinforced concrete columns. However, T-plate not anchored fully into a column base can seldom transfer the externally applied moment, though it highly improves the ductility of column. The presence of mortar cover for strengthening steel elements is significantly effective in enhancing the initial stiffness and flexural capacity of the strengthened columns, but has an adversely effect on enhancing the ductility. The ultimate moment strength predicted from the extended section laminae method in better agreement with test results compared with predictions obtained using stress black specified in ACI 318-05.

A Study on the Structural Behavior of Fabricated Columns Reinforced with Steel sheet Forms and Angles (ㄱ형강과 강판을 이용한 조립 기둥의 거동에 관한 연구)

  • Kim, Sung-Bae;Lee, Chang-Nam;Yoon, Yeong-Ho;Kim, Sang-Seup
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.4
    • /
    • pp.89-98
    • /
    • 2007
  • The purpose of this study is to experimentally evaluate the structural behavior of built-up type column consisted of angles and y-shape steel sheet forms for filling concrete. This column for minimizing form working and reinforcement placing is able to improve capacity of construction and reduce the term of works. Thirteen 1/3 scaled columns were fabricated. The main variables are 1) effect of angles and y-shape steel sheets of fabricated columns, 2) slenderness of column, 3) eccentricity of column. The results show that the experimental capacity of built-up type column is similar to theoretical one by reinforcement concrete design code. The maximum loads increase according to the rate of angle to cross section of column.

A Study on Steel Pipe Coupler for Splicing Spiral Rebars (나선철근 이음을 위한 강관압착식 커플러에 관한 연구)

  • 오민수;이규세;김수만
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.433-436
    • /
    • 1999
  • The spiral provides the column with the ability to absorb considerable deformation prior to failure. Although this toughness is the principal gain that is achieved by the use of spiral reinforced columns, the its serviceability is limited by the fault of lap splices. The mechanical connection for the spiral bar placement is development in the study. The study contains for the experiment of the mechanical connection.

  • PDF

Comparison of Steel Fiber Reinforced Column Capacity Using Ordinary and High Strength Concrete (콘크리트 강도에 따른 강섬유 보강기둥의 성능비교)

  • 장극관;이현호;문상덕
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.23-28
    • /
    • 2001
  • Since the steel fiber used in concrete to improve shear and ductility capacity, a number of laboratory tests have been studied to define shear strengthening effect according steel fiber contents in concrete. This study investigates shear strengthening effect of steel fiber in RC columns according to compression strength of concrete. From the structural performance test, following conclusions can be made; the maximum enhancement of shear strengthening effect can be achieved at about 1.0 %~l.5 % of steel fiber contents in comparison with shear capacity ratio, and ductility capacity slightly improved as steel fiber contents increased.

  • PDF

A Study on Axial Force - Moment Capacity of High-Strength Concrete Tied Column Sections (고강도 콘크리트 기둥단면의 축력-모멘트 강도에 관한 연구)

  • 박해균;박동규;박영식;손영현;이재훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.300-305
    • /
    • 1996
  • Reinforced concrete column is an effective structural element to take advantage of high strength concrete. This paper presents an experimental and analytical strength of high strength concrete rectangular tied column sections under eccentric loading. The test variables are concrete strength, steel ratios, slenderness and eccentricity. The analytical results of the ACI's rectangular stress block, Zia's modified rectangular stress block, and a trapezoid block are compared with experimentally obtained data. It may be concluded that the trapezoid stress block provided the most reasonable column section capacities for high strength concrete columns.

  • PDF

SEismic Performance of Circular RC Bridge Piers designed in Moderate on low Seismic Zone (중.약진 지역의 원형 내진 RC 교각의 내진성능평가)

  • 박종협;조창백;박희상;정영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.452-457
    • /
    • 2000
  • This research aims at evaluating the seismic performance of the existing R/C bridge piers, which were seismically designed in accordance with the provision of moderate confinement design code (Eurocode 8). The work presented in this paper experimentally investigates the ductility and hysteretic behavior of circular reinforced concrete columns with moderate confinement. Pseudo-dynamic tests have been carried out on two scaled R/C column specimens to investigate their hysteretic behavior and other seismic performance.

  • PDF