• Title/Summary/Keyword: regulator

Search Result 2,723, Processing Time 0.027 seconds

Development of High Current Shunt Regulator for Beam Based Alignment in PLS 2GeV Storage Ring (포항방사광가속기 빔위치 정렬 용 정밀전원장치 개발)

  • Nam, S.H.;Suh, J.H.;Ha, K.M.;Huang, J.Y.;Ko, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2249-2251
    • /
    • 1997
  • Total 144 quadrupole magnets are installed in PLS. The magnets are connected in series with groups of two or 24. Each group is powered by a high-precision constant-current DC power supply. For the purpose of the beam based alignment of beam position monitors in the PLS, it is necessary to adjust the current of each quadrupole independently. To achieve this, a high current shunt regulator is designed. It can shunt a maximum 50 A of the quadrupole magnet current. The shunt regulator is programmable and the current amplitude can be varied linearly with a 12-bit resolution. Power transistors are used in the current shunt regulator. The operation of transistors is in linear region. The RS232C protocol is used for remote control and status report of the shunt regulator to the main control centre of the PLS. Preliminary result indicates that the calibration accuracy of the beam position monitor can be achievable in less than $10{\mu}m$.

  • PDF

Numerical Study for The Critical-Flow-Characteristics of The Pressure Regulator and Considerations as a Pipe Network Element (II);Influence of the Cross-Sectional-Area and Opening Ratio (정압기 임계유동특성 및 배관망해석 요소로서의 고려에 관한 수치해석적 연구(II);단면적 및 개도 변화)

  • Shin, C.H.;Ha, J.M.;Lee, C.G.;Her, J.Y.;Im, J.H.;Joo, W.G.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1454-1459
    • /
    • 2004
  • The major parameters governing the fluid dynamical and thermo-dynamical behavior in the large pipeline network system are friction loss and the pipeline length. But in local pipeline networks and relatively short distance pipeline system, secondary loss and the considerations of the moving states of the fluid machine are also important. One of the major element in local pressure control system is pressure regulator. It causes the variations of the physical properties in that pipeline system. When it is under working, the accurate analysis of the flow properties is so difficult. In this study, some numerical approaches to investigate the critical-flow-characteristics of the pressure regulator have been done according to the variations of the opening ratio or cross-sectional area and the detail examinations and considerations of the pressure regulator as a pipeline network elements have been carried. Finally the flow-flied distributions and critical-flow-characteristics have been presented in detail and the critical flow phenomena and the relation to the opening ratio or cross-sectional-area ratio have been studied.

  • PDF

Electro-pneumatic regulator using multilayer PZT actuator (적층형 압전액추에이터 방식 전-공 레귤레이터)

  • Yun, So-Nam;Kim, Chan-Yong;Park, Jung-Ho;Youn, Dong-Won
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.979-984
    • /
    • 2007
  • This paper presents a new control mechanism for the proportional pressure control which is accomplished by electro-pneumatic regulator using two PZT actuators. The electro-pneumatic regulator of this study is 2-stage type and consists of two piezoelectric actuators, a controller and a main poppet valve. The piezoelectric actuators are multilayer bender type and are controlled by digital signal. Proportional pressure control technique is very important because that can derive improvement of product quality and driving ability in the pneumatic system. Solenoid actuator method for pressure control is widely used but this actuator has a high power consumption characteristics. So new actuator is required for the energy saving. In this study, PZT actuator for the pressure control was fabricated and experimented instead of the conventional type solenoid actuator. Experiments for the new control mechanism of the elector-pneumatic regulator were operated under the input condition of 0.4[MPa] and it was confirmed that this mechanism has a good control characteristics to the response sensitivity and hysteresis.

  • PDF

High precision Automatic Voltage Regulator by using series transformer (직렬 변압기를 이용한 고정밀 자동전압조절기)

  • Zhang, Lei;Lee, Hwa-Chun;Jung, Tae-Uk;Nam, Hae-Kon;Nam, Soon-Ryul;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.574-576
    • /
    • 2008
  • Now there are two types Non-contact compensation AC automatic voltage regulator (A.V.R). One is transformer compensation regulator, whose principle is the combination of multiple compensation transformers, do the compensation by turning on and off the connections of the transformer through the multi-full bridge circuit. This method removed the mechanical drive and contacts, which increases the life and the dynamic performance of the A.V.R. However, the compensation is multilevel, and it needs many compensation transformers and switches, the circuit is complex, the compensation precision is low. Another type is PWM switch AC regulator, whose principle is getting the AC voltage from the input, then induce the AC compensation voltage through commutating and high frequency PWM transforming, and phase tracking. Here the compensation is step-less, the compensation precision is high, and the response is fast. But the circuit is complex, and it needs an inverse compensation transformer, which is difficult to realize high-power applications. In this paper, it shows an Automatic Voltage Regulator which use high frequency PWM inverter do compensation. This A.V.R has the function as the custom-power, which make the performance of the power supply in a high level.

  • PDF

PQ Control of Micro Grid Inverters with Axial Voltage Regulators

  • Chen, Yang;Zhao, Jinbin;Qu, Keqing;Li, Fen
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1601-1608
    • /
    • 2015
  • This paper presents a PQ control strategy for micro grid inverters with axial voltage regulators. The inverter works in the voltage-controlled mode and can help improve the terminal power quality. The inverter has two axial voltage regulators. The 1st regulator involves the output voltage amplitude and output impedance, while the 2nd regulator controls the output frequency. The inverter system is equivalent to a controllable voltage source with a controllable inner output impedance. The basic PQ control for micro grid inverters is easy to accomplish. The output active and reactive powers can be decoupled well by controlling the two axial voltages. The 1st axial voltage regulator controls the reactive power, while the 2nd regulator controls the active power. The paper analyses the axial voltage regulation mechanism, and evaluates the PQ decoupling effect mathematically. The effectiveness of the proposed control strategy is validated by simulation and experimental results.

A Low Drop Out Regulator with Improved Load Transient Characteristics and Push-Pull Pass Transistor Structure (Push-Pull 패스 트랜지스터 구조 및 향상된 Load Transient 특성을 갖는 LDO 레귤레이터)

  • Kwon, Sang-Wook;Song, Bo Bae;Koo, Yong-Seo
    • Journal of IKEEE
    • /
    • v.24 no.2
    • /
    • pp.598-603
    • /
    • 2020
  • In this paper present a Low Drop-Out(LDO) regulator that improves load transient characteristics due to the push-pull pass transistor structure is proposed. Improved load over the existing LDO regulator by improving the overshoot and undershoot entering the voltage line by adding the proposed push-pull circuit between the output stage of the error amplifier inside the LDO regulator and the gate stage of the pass transistor and the push-pull circuit at the output stage. It has a delta voltage value of transient characteristics. The proposed LDO structure was analyzed in Samsung 0.13um process using Cadence's Virtuoso, Spectre simulator.

A Study on the Real Time Digital Field Time-Constant Regulator for Micro-Synchronous Machine (축소형 동기발전기 실시간 디지털 계자시정수 보상장치에 관한 연구)

  • Kim, Dong-Joon;Moon, Young-Hwan;Hwang, Chi-U
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.253-256
    • /
    • 1997
  • This paper describes a novel design method for compensating field time-constant of micro-synchronous machine so that its terminal flux can show the same characteristics as large-scale synchronous machine's. In addition to it, the suggested design method can determine the field time-constant regulator's parameters considered the nonlinearities of micro-synchronous machine such as saturation and loading effect. This method applied to 5kVA micro-synchronous machine, and the digital time-constant regulator with digital AVR were designed such that the short field time-constant, $T_{do}'=1.12\;sec$, can take on the large-scale synchronous machine time constant, $T_{do}'=1.47\;sec$. After determining the parameters of controllers, the real time digital time-constant regulator and digital AVR algorithm were implemented by using the PC with Penumum processor, and the usefulness of suggested real time digital time-constant regulator was verified by observing its good performance on the excitation of micro-synchronous machine.

  • PDF

A Study on Performance Characteristics with the Control System of CNG Regulator (CNG 레귤레이터의 제어 방식에 따른 성능특성 연구)

  • Seo, Ji-Won;Yang, Jeong-Jik;Kim, Jin-Ho;Lim, Jong-Wan
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.3
    • /
    • pp.33-38
    • /
    • 2017
  • The domestic vehicles remodeling the "CNG Bi-fuel Kit" are mostly in operation with installing the mechanical regulator applying the Diaphragm. However, due to the material characteristics of Diaphragm and characteristics of mechanical pressure control method, various problems are happening. This study tries to deduce the improvement plan through the checking of performance characteristics according to the pressure control method of CNG regulator and progress of comparative analysis. According to the test result, the decompression method applying the Diaphragm has advantage compared to the method applying the Piston. Furthermore, it was confirmed that through the electronic pressure control, it is possible to improve the general performance of the regulator.

LDO Regulator with Improved Regulation Characteristics and Feedback Voltage Buffer Structure (Feedback Buffer 구조 및 향상된 Regulation 특성을 갖는 LDO regulator)

  • Jung, Jun-Mo;Park, Tae-Ryong
    • Journal of IKEEE
    • /
    • v.26 no.3
    • /
    • pp.462-467
    • /
    • 2022
  • The feedback buffer structure is proposed to alleviate the overshoot and undershoot phenomenon and the regulation of the output voltage. The conventional LDO regulator undergoes a regulation voltage change caused by a constant load current change. An LDO regulator with a feedback voltage sensing structure operates in the input voltage range of 3.3 to 4.5 V and has a load current of up to 150 mA at output voltage of 3 V. According to the simulation results, a regulation value of 6.2 mV was ensured when the load current uniformly changed to 150 mA.

On the Robust Stability of the Optimal Digital Linear Regulator Having L Sample Controlling Delays. (L샘츨의 제어늦음을 갖는 다지탈 최적 선형 Regulator의 Robust 안전성)

  • 이동철;정형환
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.6
    • /
    • pp.437-443
    • /
    • 1987
  • Due to the recent development of microprocessor, the digital control is now in use for the practical structure of the control systems, but it leaves the problem of controlling delays caused by computation time when it is applied to the realization problems, such as application method of the control law and controlling effect of continuous control, etc. This paper deals with robust stability of the digital regulator which compensates for the controlling delays by applying prediction values of state.

  • PDF