• 제목/요약/키워드: regular imbedding

검색결과 4건 처리시간 0.019초

고감성 의류용 축열 니트소재의 물성 (Physical Property of Heat Storage Knitted Fabrics for High Emotional Garment)

  • 김현아;허경;김승진
    • 한국의류산업학회지
    • /
    • 제17권2호
    • /
    • pp.295-304
    • /
    • 2015
  • This paper investigated wear comfort property of heat storage knitted fabrics for high emotional garment. For this purpose, ZrC imbedded PET knitted fabric was prepared and various physical properties such as thermal, wicking and drying characteristics were measured. In addition, far-infrared emission characteristics of ZrC imbedded PET was analysed and tactile hand property and dye affinity of ZrC imbedded knitted fabric were also studied in comparison with regular and other commercial heat storage PET knitted fabrics. It was observed that Zr imbedded amount in the yarn was 19.29% by ingredient analysis and far-infrared emission energy was $3.65{\times}10^2W/m^2$, emissivity was 0.906 at the range of wavelength $6{\sim}20{\mu}m$. It was found that maximum heat flow (Qmax) of ZrC imbedded PET knitted fabric was lower than that of regular PET one and warmth keepability rate was higher than that of regular PET one, which means ZrC imbedded PET have heat storage property. Drying property of ZrC imbedded knitted fabric was better than that of regular PET one due to heat by far-infrared emitted from ZrC in the core of filament. It revealed that wicking property of the ZrC imbedded fabric was not influenced by far-infrared emission, but affected by fibre physical properties. Tactile hand property of ZrC imbedded knitted fabric was not influenced by imbedding ZrC in the filament but affected preferably by structure of knitted fabric. Dye affinity of ZrC imbedded PET knitted fabric was less influenced by dyeing temperature and time than regular PET knitted one.

하나 걸른 행과 연결된 이중층 셔플넷 토폴로지를 이용한 광 Wide-Area 네트워크 설계 (Design of a Wide-Area Optical Network using Asymmetric Bilayered ShuffleNet)

  • 지윤규
    • 대한전자공학회논문지SD
    • /
    • 제39권6호
    • /
    • pp.19-25
    • /
    • 2002
  • 규칙적인 가상 연결방법을 이용하면 노드에서 라우팅을 위한 프로세싱 시간이 단축되어 고속의 네트워크에 적용이 가능하다. 규칙적인 가상 연결방법의 하나인 셔플넷은 일반적으로 p개의 연결이 다른 노드들과 이루어진다. 그러나 우리가 제안한 하나 걸른 행과 연결된 이중층 셔플넷 토폴로지를 이용하면 2p개의 노드들과 동시에 연결되므로 더욱 효과적인 광역 통신망에 적용할 수 있다. 이 하나 걸른 행과 연결된 이중층 셔플넷 토폴로지를 이용하여 물리적 토폴로지에 가상 토폴로지를 imbedding하는 방법을 본 논문에서 연구하였다. 전체 지연 시간을 최소화하는 것을 목표로 네트워크를 최적화하였다.

Clinical Application of Endoscopic Inguinal Lymph Node Resection after Lipolysis and Liposuction for Vulvar Cancer

  • Wu, Qiang;Zhao, Yi-Bing;Sun, Zhi-Hua;Ni, Jing;Wu, Yu-Zhong;Shao, Heng-Hua;Qu, Jun-Wei;Huang, Xin-En
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권12호
    • /
    • pp.7121-7126
    • /
    • 2013
  • Aim: To examine lymph nodes obtained after lipolysis and liposuction of subcutaneous fat of the inguinal region of female vulvar cancer patients to explore the feasibility of clinical application. Methods: The field of operation was on the basis of the range of the conventional resection of inguinal lymph nodes. We injected lipolysis liquid fanwise, started liposuction after 15-20 minutes; then the subcutaneous fatty tissue was sucked out clearly by suction tube. We selected the first puncture holes located on 2-3 cm part below anterior superior spine, the others respectively being located 3cm and 6cm below the first for puncturing into the skin, imbedding a trocar to intorduce $CO_2$ gas and the specular body, and excise the lymph nodes by ultrasonic scalpel. The surgical field chamber was set with negative pressure drainage and was pressured with a soft saline bag after surgery. Results: A lacuna emerged from subcutaneous of the inguinal region after lipolysis and liposuction, with a wide fascia easily exposed at the bottom where lymph nodes could be readily excised. The number of lymph nodes of ten patients excised within the inguinal region on each side was 4-18. The excised average number of lymph nodes was 11 when we had mature technology. Conclusion: Most of adipose tissue was removed after lipolysis and liposuction of subcutaneous tissue of inguinal region, so that the included lymph nodes were exposed and easy to excise by endoscope. This surgery avoided the large incision of regular surgery of inguinal region, the results indicating that this approach is feasible and safe for used as an alternative technology.