• Title/Summary/Keyword: region contrast

Search Result 858, Processing Time 0.039 seconds

Change Detection Using Multispectral Satellite Imagery and Panchromatic Satellite Imagery (다중분광 위성영상과 팬크로매틱 위성영상에 의한 변화 검출)

  • Lee, jin-duk;Han, seung-hee;Cho, hyun-go
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2008.05a
    • /
    • pp.897-901
    • /
    • 2008
  • The objective of this study is to conduct land cover classification respectively using Landsat TM data collected on Oct., 1985 and KOMPSAT-1 EOC data collected on Jan., 2000 covering Gumi city, Gyeongbuk Province and to detect urban change by comparing between both land cover maps. Multispectral images of Landsat TM have spatial resolution of 30m are well known as useful data for extracting information related to landcover, vegetation classification, urban growth analysis and so forth. In contrast, as KOMPSAT-1 EOC collects panchromatic images with relatively high spatial resolution of 6.6m. We try to analyze how accurate landcover classification result is able to be derived from the panchromatic images. As the results of the study, the KOMPSAT EOC data with high resolution greater than 4 times showed higher classification degree than Landsat TM data. It was ascertained that the built-up region was extended by three to four times in the last 15 years between 1985 and 2000. In the contrast, it was shown that the forest region was decreased by 15% to 27% and the grass region including agricultural region was decreased by 28% to 45%.

  • PDF

Diagnostic Significance of Radionuclide Venography - A Comparison with X-ray Contrast Venography - (방사성동위원소정맥촬영술(放射性同位元素靜脈撮影術)의 진단적(診斷的) 의의(意義) - X-선정맥조영술(線靜脈造影術)과의 비교(比較) 연구(硏究) -)

  • Bae, S.H.;Park, J.H.;Han, M.C.;Cho, B.Y.;Koh, C.S.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.15 no.2
    • /
    • pp.19-25
    • /
    • 1981
  • Radionuclide venographies were performed in 138 limbs of 58 patients and X-ray contrast venographies were performed in 23 paitents of them. Positive radionuclide venography findings were area of decreased sponding to the region of thrombosis, abnormal collateral flows below the lesion. The success rate of radionulide venography was 89% and the overall concordance between radionuclide venography and X-ray contrast venography was 91%. Radionuclide venography is simple and easy to perform and less invasive than X-ray contrast venography. These results indicate that radionuclide venography is the most ideal screening test for the detection of venous thrombosis in patient with signs & symptoms of deep vein thrombosis.

  • PDF

Laser Speckle Contrast Imaging for Measuring Cerebral Blood Flow Changes Caused by Electrical Sensory Stimulation

  • Cho, Ahra;Yeon, Chanmi;Kim, Donghyeon;Chung, Euiheon
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.88-93
    • /
    • 2016
  • Recently laser speckle contrast (LSC) imaging has become a widely used optical method for in vivo assessment of blood flow in the animal brain. LSC imaging is useful for monitoring brain hemodynamics with relatively high spatio-temporal resolution. A speckle contrast imaging system has been implemented with electrical sensory stimulation apparatus. LSC imaging is combined with optical intrinsic signal imaging in order to measure changes in cerebral blood flow as well as neural activity in response to electrical sensory stimulation applied to the hindlimb region of the mouse brain. We found that blood flow and oxygen consumption are correlated and both sides of hindlimb activation regions are symmetrically located. This apparatus could be used to monitor spatial or temporal responses of cerebral blood flow in animal disease models such as ischemic stroke or cortical spreading depression.

The Comparison of the SIFT Image Descriptor by Contrast Enhancement Algorithms with Various Types of High-resolution Satellite Imagery

  • Choi, Jaw-Wan;Kim, Dae-Sung;Kim, Yong-Min;Han, Dong-Yeob;Kim, Yong-Il
    • Korean Journal of Remote Sensing
    • /
    • v.26 no.3
    • /
    • pp.325-333
    • /
    • 2010
  • Image registration involves overlapping images of an identical region and assigning the data into one coordinate system. Image registration has proved important in remote sensing, enabling registered satellite imagery to be used in various applications such as image fusion, change detection and the generation of digital maps. The image descriptor, which extracts matching points from each image, is necessary for automatic registration of remotely sensed data. Using contrast enhancement algorithms such as histogram equalization and image stretching, the normalized data are applied to the image descriptor. Drawing on the different spectral characteristics of high resolution satellite imagery based on sensor type and acquisition date, the applied normalization method can be used to change the results of matching interest point descriptors. In this paper, the matching points by scale invariant feature transformation (SIFT) are extracted using various contrast enhancement algorithms and injection of Gaussian noise. The results of the extracted matching points are compared with the number of correct matching points and matching rates for each point.

The Influence of Global Sea Surface Temperature Anomalies on Droughts in the East Asia Monsoon Region

  • Awan, Jehangir Ashraf;Bae, Deg-Hyo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.224-224
    • /
    • 2015
  • The East Asia monsoon is one of the most complex atmospheric phenomena caused by Land-Sea thermal contrast. It plays essential role in fulfilling the water needs of the region but also poses stern consequences in terms of flooding and droughts. This study analyzed the influence of Global Sea Surface Temperature Anomalies (SSTA) on occurrence of droughts in the East Asia monsoon region ($20^{\circ}N-50^{\circ}N$, $103^{\circ}E-149^{\circ}E$). Standardized Precipitation Index (SPI) was employed to characterize the droughts over the region using 30-year (1978-2007) gridded rainfall dataset at $0.5^{\circ}$ grid resolution. Due to high variability in intensity and spatial extent of monsoon rainfall the East Asia monsoon region was divided into the homogeneous rainfall zones using cluster analysis method. Seven zones were delineated that showed unique rainfall regimes over the region. The influence of SSTA was assessed by using lagged-correlation between global gridded SSTA ($0.2^{\circ}$ grid resolution) and SPI of each zone. Sea regions with potential influence on droughts in different zones were identified based on significant positive and negative correlation between SSTA and SPI with a lag period of 3-month. The results showed that SSTA have the potential to be used as predictor variables for prediction of droughts with a reasonable lead time. The findings of this study will assist to improve the drought prediction over the region.

  • PDF

Perception of Japanese word-initial stops by native listeners (모어청자에 의한 일본어 어두 폐쇄음의 지각)

  • Byun, Hi-Gyung
    • Phonetics and Speech Sciences
    • /
    • v.13 no.3
    • /
    • pp.53-64
    • /
    • 2021
  • It is known that the voicing contrast for Japanese word-initial stops is primarily realized as differences in the voice onset time (VOT). However, recent studies have reported that voiced stops are more often produced with a positive VOT than with a negative VOT among the younger generation nationwide. It is also known that post-stop F0 is associated with the stop contrast, but the degree of F0 use differs from region to region. This study explores whether the difference in post-stop F0 functions as a perceptual cue to the stop contrast along with VOT. Fifty-five college students who are native listeners from four different regions participated in two or three perception tests. The results show that VOT is a primary cue to the voiced-voiceless distinction of word-initial stops, but that the effect of post-stop F0 on the stop contrast is marginal. The post-stop F0 is involved in perception only when VOT is ambiguous, such that a sound with high F0 is more often perceived as a voiceless stop, but not vice versa. The results of this study indicate that the acoustic parameters associated with the stop contrast are not the same in production and perception, and suggest that other factors such as context, which is not an acoustic characteristic, may also be involved in the stop contrast.

Distribution of Aortic Root Calcium in Relation to Frame Expansion and Paravalvular Leakage After Transcatheter Aortic Valve Implantation (TAVI): An Observational Study Using a Patient-specific Contrast Attenuation Coefficient for Calcium Definition and Independent Core Lab Analysis of Paravalvular Leakage

  • Nahid El Faquir;Quinten Wolff;Rafi Sakhi;Ben Ren;Zouhair Rahhab;Sander van Weenen;Patrick Geeve;Ricardo P J Budde;Eric Boersma;Joost Daemen;Nicolas M van Mieghem;Peter P de Jaegere
    • Journal of Cardiovascular Imaging
    • /
    • v.30 no.4
    • /
    • pp.292-304
    • /
    • 2022
  • BACKGROUND: Calcium is a determinant of paravalvular leakage (PVL) after transcatheter aortic valve implantation (TAVI). This is based on a fixed contrast attenuation value while X-ray attenuation is patient-dependent and without considering frame expansion and PVL location. We examined the role of calcium in (site-specific) PVL after TAVI using a patient-specific contrast attenuation coefficient combined with frame expansion. METHODS: 57 patients were included with baseline CT, post-TAVI transthoracic echocardiography and rotational angiography (R-angio). Calcium load was assessed using a patient-specific contrast attenuation coefficient. Baseline CT and post-TAVI R-angio were fused to assess frame expansion. PVL was assessed by a core lab. RESULTS: Overall, the highest calcium load was at the non-coronary-cusp-region (NCR, 436 mm3) vs. the right-coronary-cusp-region (RCR, 233 mm3) and the left-coronary-cusp-region (LCR, 244 mm3), p < 0.001. Calcium load was higher in patients with vs. without PVL (1,137 vs. 742 mm3, p = 0.012) and was an independent predictor of PVL (odds ratio, 4.83, p = 0.004). PVL was seen most often in the LCR (39% vs. 21% [RCR] and 19% [NCR]). The degree of frame expansion was 71% at the NCR, 70% at the RCR and 74% at the LCR without difference between patients with or without PVL. CONCLUSIONS: Calcium load was higher in patients with PVL and was an independent predictor of PVL. While calcium was predominantly seen at the NCR, PVL was most often at the LCR. These findings indicate that in addition to calcium, specific anatomic features play a role in PVL after TAVI.

A Comparison of Iopamidol with Iopromide and Iohexol Contrast Media in Hepatic CT Angiography in Beagle Dogs (비글견의 간 CT 혈관조영상에서의 Iopamidol과 Iopromide, Iohexol 조명제의 비교실험)

  • Jeong Yu-Cheol;Lim Chang-Yun;Kim Gyeong-Min;Lee Sung-Ok;Jung Joo-Hyun;Chang Jin-Hwa;Oh Sun-Kyoung;Song Kyoung-Jin;Yoon Jung-Hee;Choi Min-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.23 no.2
    • /
    • pp.129-132
    • /
    • 2006
  • The purpose of this paper was to compare the clinical efficacy of iopamidol and iopromide, iohexol nonionic contrast media in terms of their image quality in Beagle dogs with hepatic CT angiography and their application in veterinary clinics. With 9 Beagle dogs, contrast media of iopamidol (pamiray-$300^(R)$) and iopromide (ultravist-$300^(R)$, iohexol (omnipaque-$300^(R)$) were induced intravenously (600 mg I/kg, BW) and CT angiography was done under general anesthesia. CT scan included scout, pre-contrast and cine examinations. During CT angiography, peak HU (Hounsfield unit) and peak time were examined on each site (ROI; region of interest) of the aorta, caudal vena cava, potral vein and liver parenchyma. Any side effects were also examined. After experiments, it was found that there were no significant changes of HU and maximal enhancing time of each ROIs of aorta, caudal vena cava, portal vein and liver parenchyma between these contrast media. And any side effects were not noted. So it is concluded that iopamidol has similiar contrast enhancement like as iopromide and iohexol in hepatic angiography and and it is thought to be useful for evaluation of the abdominal organs by CT scan in veterinary clinics.

A Study on Visual Attention on Color Perception by Visitors of Children's Hospital (어린이병원 방문자의 색채지각에 나타난 시각적 주의에 관한 연구)

  • Cho, Eun-Kil;Son, Kwang-Ho
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.2
    • /
    • pp.50-58
    • /
    • 2016
  • The design of children's hospitals is highly dependent on color schemes. As a space shared together by both adults and children, the design of children's hospitals require color coordination that takes account of the users' characteristics. Visual perception tracking experiment was conducted on the 2 chosen experimental images with a target group made up of adults and children, the following results were found. First, visual attention characteristics of spatial elements' colors were found. The contrast of colors were discovered to effect attention, especially the information desk region showed highest attention. Pillars are subjected to a higher attention relative to other spatial elements, it is suggested when using accent colors to use it only when it is absolutely necessary in partial areas. In contrast, floor patterns were found to be subjected to very low attention relative to other elements. Second, effects of color contrast on visual attention were uncovered. Although color contrast effects attention for both adults and children, children were found to be more effected by color contrast than adults. Especially, children's tendency to rely on color contrast for visual recognition was higher than adults. Since when using only one type on a wide surface children show higher attention on the < vivid > colors than adults, when planning a color coordination for children using < pale > colors instead of < vivid > ones in background for a large surface is seen as a more desired method to increase attention by putting emphasis on the [sharply contrasting] colors.

Analyzing the Spray-to-spray Interaction of GDI Injector Nozzle in the Near-field Using X-ray Phase-Contrast Imaging (X선 위상차 가시화 기법을 이용한 GDI 인젝터 노즐 근방의 분무 간 상호간섭 해석)

  • Bae, Gyuhan;Moon, Seoksu
    • Journal of ILASS-Korea
    • /
    • v.25 no.2
    • /
    • pp.60-67
    • /
    • 2020
  • Despite its benefit in engine thermal efficiency, gasoline-direct-injection (GDI) engines generate substantial particulate matter (PM) emissions compared to conventional port-fuel-injection (PFI) engines. One of the reasons for this is that the spray collapse caused by the spray-to-spray interaction forms the locally rich fuel-air mixture and increases the fuel wall film. Previous studies have investigated the spray collapse phenomenon through the macroscopic observation of spray behavior using laser optical techniques, but it is somewhat difficult to understand the interaction between sprays that is initiated in the near-nozzle region within 10 mm from the nozzle exit. In this study, the spray structure, droplet size and velocity data were obtained using an X-ray imaging technique from the near-nozzle to the downstream of the spray to investigate the spray-to-spray interaction and discuss the effects of spray collapse on local droplet size and velocity distribution. It was found that as the ambient density increases, the spray collapse was promoted due to the intensified spray-to-spray interaction, thereby increasing the local droplet size and velocity from the near-nozzle region as a result of droplet collision/coalescence.