• Title/Summary/Keyword: region contrast

Search Result 858, Processing Time 0.029 seconds

Consideration of Standardized Uptake Value (SUV) According to the Change of Volume Size through the Application of Astonish TF Reconstruction Method (Astonish TF 재구성 기법의 적용을 통한 체적 크기의 변화에 따른 표준섭취계수(SUV)에 관한 고찰)

  • Lee, Juyoung;Nam-Kung, Sik;Kim, Ji-Hyeon;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.115-121
    • /
    • 2014
  • Purpose: In addition to improving the quality of the PET image, through much research, the development of various programs are performed. Astonish TF reconstruction techniques by Philips can confirm the improved contrast of the lesion. Also, It's image reconstruction of 2 mm is possible with rapid reconstruction rate than conventional. In this study, we compared and evaluated Standardized Uptake Value (SUV) in accordance with the 2 mm reconstruction techniques and traditional 4 mm from the $^{18}F-FDG$ PET whole body image. Materials and Methods: In the phantom experiment, NEMA IEC body phantom (sphere: 10, 13, 17, 22, 28, 37 mm) was used to obtain images by using GEMINI TF 64 PET/CT (Philips, Cleveland, USA). Also, In the clinical images, we performed $^{18}F-FDG$ PET/CT examination to 30 women (age: $55.1{\pm}11.3$, BMI: $24.1{\pm}2.9$) with a diagnosis of breast cancer. After that, we reconstructed images in 2 mm and 4 mm respectively. The region of interest was drawn to acquired images. Since then, we measured SUV and statistically analyzed with SPSS ver.18 by using EBW (Extended Brilliance Workstation) NM ver.1.0. Results: After analyzing the result of the phantom study, there was a tendency that the bigger hot sphere size, the higher SUV. If you compared the 2 mm reconstruction techniques to 4 mm, it increased 95.78% in 10 mm, 50.60% in 13 mm, 25.00% in 17 mm, 30.04% in 22 mm, 31.81% in 28 mm, and 27.84% in 37 mm. Through the result of the analysis of the 2 mm reconstruction techniques and 4 mm in clinical images, it appeared that SUV of 2 mm was higher than that of 4 mm. Also the smaller the volume was, the more the change rate increased. Conclusion: After analyzing the result of the clinical picture and phantom experiments applied by Astonish TF reconstruction techniques, as the size of the volume was small, the change rate of the SUV increased. Therefore, it was necessary to further research about the SUV correction for accurate and active utilization of 2 mm reconstruction techniques which had excellent lesion discrimination ability and contrast in clinic.

  • PDF

Status of Agrometeorological Information and Dissemination Networks (농업기상 정보 및 배분 네트워크 현황)

  • Jagtap, Shrikant;Li, Chunqiang
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.6 no.2
    • /
    • pp.71-84
    • /
    • 2004
  • There is a growing demand for agrometeorological information that end-users can use and not just interesting information. lo achieve this, each region/community needs to develop and provide localized climate and weather information for growers. Additionally, provide tools to help local users interpret climate forecasts issued by the National Weather Service in the country. Real time information should be provided for farmers, including some basic data. An ideal agrometeorological information system includes several components: an efficient data measuring and collection system; a modern telecommunication system; a standard data management processing and analysis system; and an advanced technological information dissemination system. While it is conventional wisdom that, Internet is and will play a major role in the delivery and dissemination of agrometeorological information, there are large gaps between the "information rich" and the "information poor" countries. Rural communities represent the "last mile of connectivity". For some time to come, TV broadcast, radio, phone, newspaper and fax will be used in many countries for communication. The differences in achieving this among countries arise from the human and financial resources available to implement this information and the methods of information dissemination. These differences must be considered in designing any information dissemination system. Experience shows that easy across to information more tailored to user needs would substantially increase use of climate information. Opportunities remain unexplored for applications of geographical information systems and remote sensing in agro meteorology.e sensing in agro meteorology.

A Study on Applied to Optimal Diagnostic Device in Portal Vein Visualization: Focused on MRI and CT (간문맥 묘출을 위한 최적의 영상진단 장치에 관한 연구: MRI, CT 중심으로)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.217-225
    • /
    • 2019
  • The purpose of this study was to quantitate signal to noise ratio and contrast to noise ratio of the portal vein using CT and 3.0T MRI and to investigate the optimal imaging device. Twenty patients who inspective CT and 3.0T MRI between February 2018 and April 2018 were randomly assigned to receive data from the picture archiving communication system. The SNR and CNR values were evaluated by measuring the mean and standard deviation of the region of interest of the four regions of the portal vein (the main portal vein, the right vein, the left vein, and the middle vein). The results showed that SNR was 9.180.72 in the right context, 9.410.84 in the left context, 9.540.59 in the middle context, 9.550.75 in the order context, and 22.292.03 in the right context and 25.893 in the 3.0T MRI. 19, median context: 24.392.87, and order Mac: 26.642.30 (p<0.05). CNR was 3.790.68 in the CT context, 3.740.65 in the left context, 3.710.39 in the middle context, 3.790.68 in the order context, 9.490.65 in the right context, and 11.0001.90 in the 3.0T MRI, Intermediate context: 12.701.75, order Mac: 10.010.98, 3.0T MRI was higher than CT (p<0.05). In conclusion, SNR and CNR values were higher in the 3.0T MRI than CT in the 4 portal regions. Therefore, 3.0T MRI using non-ionizing radiation was the most superior imaging equipment than CT.

Effect of Human Implantable Medical Devices on Dose and Image Quality during Chest Radiography using Automatic Exposure Control (자동노출제어를 적용한 흉부 방사선 검사 시 인체 이식형 의료기기가 선량과 화질에 미치는 영향)

  • Kang-Min Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.257-265
    • /
    • 2024
  • In this study, we applied AEC(Auto Exposure Control), which is used in many chest examinations, to evaluate whether medical devices inserted into the body affect the dose and image quality of chest images. After attaching three HIMD(Human implantable medical devices) to the ion chamber, the Monte Carlo methodology-based program PCXMC(PC Program for X-ray Monte Carlo) 2.0 was applied to measure the effective dose by inputting the DAP(Dose Ares Product) value derived from the Pacemaker and CRT and Chemoport Additionally, to evaluate image quality, we set three regions of interest and one noise region on the chest and measured SNR and CNR. The final study results showed significant differences in DAP and Effective dose. There was a significant difference between Pacemaker and CRT when AEC was applied and not applied. (p<0.05) When applied, the dose increased by 37% for Pacemaekr and 52% for CRT. Chemoport showed a 10% increase in effective dose depending on whether AEC was applied, but there was no significant difference. (p>0.05) In the image quality evaluation, there was no significant difference in image quality between all HIMD insertions and AEC applied or not. (p>0.05) Therefore, when the HIMD was inserted into the chest during a chest x ray and overlapped with the ion chamber sensor, the effective dose increased, and there was no difference in image quality even at a low dose without AEC. Therefore, when performing a chest X-ray examination of a patient with a HIMD inserted, it is considered that performing the examination without applying AEC is a method that can be considered to reduce the patient's radiation exposure.

Thermotropic Behavior of Hydroxypropyl Chitosans Bearing Cholesteryl and Acryloyl Groups (콜레스테릴과 아크릴로일 그룹을 지닌 하이드록시프로필 키토산들의 열방성 거동)

  • 김장훈;정승용;마영대
    • Polymer(Korea)
    • /
    • v.28 no.1
    • /
    • pp.41-50
    • /
    • 2004
  • A new hydroxypropyl chitosan capable of forming a thermotropic liquid crystalline phase and two kinds of derivatives based on the hydroxypropyl chitosan (6-cholesteryloxycarbonylpentoxypropyl) chitosans (CHPCTs) and acrylic acid esters of CHPCT (CHPCTEs) were synthesized. The crosslinked films with liquid crystalline order were also prepared by photocrosslinking CHPCTE in mesophase. The liquid crystalline properties for all the samples and the swelling behavior of the crosslinked samples in acetone were investigated. In contrast with the hydroxypropyl chitosan, all the uncrosslinked cholesteryl-bearing samples farmed monotropic cholesteric phases with left-handed helicoidal structures and exhibited reflection colors over the full cholesteric range. This is the first report of a thermotropic cholesteric liquid crystalline chitosan derivative with reflection bands in the visible region. Both the optical pitches (λ$\_$m/'S) of CHPCT and CHPCTE decrease with temperature or with cholesteryl content at a given temperature. However, the λ$\_$m/ of CHPCT was larger than that of CHPCTE at the same temperature and at the same cholesteryl content. All the crosslinked samples did not display reflection colors, indicating that the cholesteric structure of CHPCTE significantly changes upon crosslinking. The two-dimentional anisotropic swelling characteristic of liquid crystalline networks was observed for all the crosslinked samples.

An Evaluation of the Environmental Effects of Marine Cage Fish Farms: I. Estimation of Impact Region and Organic Carbon Cycling in Sediment Using Sediment Oxygen Consumption Rates and Macrozoobenthos (해상 어류가두리양식장의 환경영향평가: I. 퇴적물 산소소모율 및 저서동물을 이용한 유기물 오염영향권 추정 및 유기탄소 순환)

  • 이재성;정래홍;김기현;권정노;이원찬;이필용;구준호;최우정
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.9 no.1
    • /
    • pp.30-39
    • /
    • 2004
  • In order to understand the environmental impact of marine cage fish farms, we measured the vertical fluxes of particulate to the sediment, the distribution of organic carbon in core samples, sediment oxygen consumption rate (SOD), and macrobenthos with increasing distance from a fish cage in Miruk island located in Tongyong. The experiment was performed in August 2003. Measured values gradually decreased with distance, indicating that the organic matter in the sediment derived from the fish farm. The dominant macrobenthos species were Tharyx mulifilis, Lumbrineris longifolia, Sigambra tentaculata, and Capitella capitata, occupying 88% of the total population. Capirella capirata, an opportunistic polychaete species, were especially abundant between 0 to 5 m radius range. The estimated impact regions of organic matter enrichment based on sediment consilmption rates and compositions of macrobenthos were in good agreement. Most organic matter derived from the fish farm was deposited within a 10 m radius and then dispersed horizontally to nearby (at least 50 m) surface sediment. The vertical organic carbon fluxes to the sediment at the fish farm were higher by a factor of two than those outside the area. The remineralization organic carbon in the upper sediment layer was estimated to be 50% (1.07 g C m$^{-2}$ day$^{-1}$ ) at the fish farm. In contrast, outside the area, 30% (0.30 g C m$^{-2}$ day$^{-1}$ ) of organic carbon was recycled and the remaining 70% was deposited to the deep sediment layer.

ASSOCIATION OF INFRARED DARK CLOUD CORES WITH YSOS: STARLESS OR STARRED IRDC CORES

  • Kim, Gwan-Jeong;Lee, Chang-Won;Kim, Jong-Soo;Lee, Youn-Gung;Ballesteros-Paredes, Javier;Myers, Philip C.;Kurtz, S.
    • Journal of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.9-23
    • /
    • 2010
  • In this paper we examined the association of Infrared Dark Cloud (IRDC) cores with YSOs and the geometric properties of the IRDC cores. For this study a total of 13,650 IRDC cores were collected mainly from the catalogs of the IRDC cores published from other studies and partially from our catalog of IRDC cores containing new 789 IRDC core candidates. The YSO candidates were searched for using the GLIMPSE, MSX, and IRAS point sources by the shape of their SED or using activity of water or methanol maser. The association of the IRDC cores with these YSOs was checked by their line-of-sight coincidence within the dimension of the IRDC core. This work found that a total of 4,110 IRDC cores have YSO candidates while 9,540 IRDC cores have no indication of the existence of YSOs. Considering the 12,200 IRDC cores within the GLIMPSE survey region for which the YSO candidates were determined with better sensitivity, we found that 4,098 IRDC cores (34%) have at least one YSO candidate and 1,072 cores among them seem to have embedded YSOs, while the rest 8,102 (66%) have no YSO candidate. Therefore, the ratio of [N(IRDC core with protostars)]/[N(IRDC core without YSO)] for 12,200 IRDC cores is about 0.13. Taking into account this ratio and typical lifetime of high-mass embedded YSOs, we suggest that the IRDC cores would spend about $10^4\sim10^5$ years to form high-mass stars. However, we should note that the GLIMPSE point sources have a minimum detectable luminosity of about $1.2 L_{\odot}$ at a typical IRDC core's distance of ~4 kpc. Therefore, the ratio given here should be a 100ver limit and the estimated lifetime of starless IRDC cores can be an upper limit. The physical parameters of the IRDC cores somewhat vary depending on how many YSO candidates the IRDC cores contain. The IRDC cores with more YSOs tend to be larger, more elongated, and have better darkness contrast than the IRDC cores with fewer or no YSOs.

Association of HIV infection with MICA(MHC class I chain-related A) gene alleles (HIV감염과 MICA (MHC class I chain-related A) 대립 유전자의 연관성)

  • Kang, Moon-Won;Wie, Seong-Heon;Kim, Yang-Ree;Lee, Joo-Shil;Pyo, Chul-Woo;Han, Hoon;Kim, Tai-Gyu
    • IMMUNE NETWORK
    • /
    • v.1 no.2
    • /
    • pp.135-142
    • /
    • 2001
  • Background: A large number of diseases occur in association with specific HLA-B or-C alleles. Recently a new gene, termed maj or histocompatibility complex class I chain-related gene A (MICA), has been identified in close proximity to HLA-B. The function of this gene is still unknown. However, it is structurally similar to HLA class I genes. MICA gene is polymorphic and is potentially associated with several diseases. Methods: To evaluate the association of MICA gene in Korean patients with human immunodeficiency virus 1 (HIV-1) infections, Polymerase chain reaction-Sequence specific primer (PCR-SSP) was done for MICA alleles in the extracellular exons, and a microsatellite analysis for GCT repeat polymorphisms in the TM exon was also completed. Results: In 199 Korean healthy controls, 7 alleles were observed and the frequencies for each allele were MICA008 (44.7%), MICA0 10 (34.2%), MICA002 (31.7%), MICA004 (23.6%), MICA0 12 (2 1.6%), MICA009 (19.6%), and MICA007 (6.5%). When 65 HIV seropositive patients were analyzed, MICA007 allele frequency was significantly higher than in controls (15.4% vs 6.5 %, RR=2.6, p<0.04). In contrast, the frequencies of other MICA alleles and microsatellite alleles in the transmembrane region of MICA gene were not significantly different between HIV seropositive patients and controls. The tight linkage between MICA alleles in the extracellular exons and GCT repeat polymorphisms in the TM exon was observed as follows; MICA002/A9, MICA004/A6, MICA007/A4, MICA008/A5.1, MICA0 10/A5, and MICA0 12/A4 in both groups. No significant difference between patients and controls was observed in the haplotype frequencies of MICA alleles in the extracellular exons and GCT repeat polymorphisms in the TM exon. Conclusion: The data suggest that immune functions related with MICA gene may affect a HIV infections.

  • PDF

Pulmonary Vessel Extraction and Nodule Reclassification Method Using Chest CT Images (흉부 CT 영상을 이용한 폐 혈관 추출 및 폐 결절 재분류 기법)

  • Kim, Hyun-Soo;Peng, Shao-Hu;Muzzammil, Khairul;Kim, Deok-Hwan
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.46 no.6
    • /
    • pp.35-43
    • /
    • 2009
  • In the Computer Aided Diagnosis(CAD) System, the efficient way of classifying nodules from chest CT images of a patient is to perform the classification of the remaining part after the pulmonary vessel extraction. During the pulmonary vessel extraction, due to the small difference between the vessel and nodule features in imaging studies such as CT scans after having an injection of contrast, nodule maybe extracted along with the pulmonary vessel. Therefore, the pulmonary vessel extraction method plays an important role in the nodule classification process. In this paper, we propose a nodule reclassification method based on vessel thickness analysis. The proposed method consist of four steps, lung region searching step, vessel extraction and thinning step, vessel topology formation and correction step and the reclassification of nodule in the vessel candidate step. The radiologists helped us to compare the accuracy of the CAD system using the proposed method and the accuracy of general one. Experimental results show that the proposed method can extract pulmonary vessels and reclassify false-positive nodules accurately.

Analysis of Effectiveness of Spectrum of Energy and Image Quality Evaluation by Aluminium Filter in the added Compound Filtration (에너지 스펙트럼과 화질평가를 통한 복합부가여과에서 알루미늄 여과판의 효율성 분석)

  • Kim, Sang-Hyun;Choi, Jae-Ho
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.187-197
    • /
    • 2015
  • This study analysed the effectiveness of aluminium(Al) filter in the added compound filtration for the removal of characteristic radiation by energy spectrum and image evaluation. 0.1, 0.2, 0.3 mm copper with and without 1 mm Al were evaluated. The energy spectrum was measured using the GATE and evaluated separately by each energy. Image quality was evaluated by PSNR, MAE, MSE, CNR, SNR and qualitative analysis was performed by seven items for resolution and contrast from chest x-ray criteria of National Cancer Screening and Cardiovascular evaluation table. In the analysis of the quality of the energy per photon spectrum with the exception of a low energy region, without Al were superior in all area. PSNR MAE, MSE, CNR, SNR and qualitative analysis were the same or slightly better. PSNR was over 30 dB and all significant and the p>0.05 in the T-test of qualitative analysis. The energy spectrum and image quality have little difference between before and after use of Al filter. Therefore, it is effective to use the Al filter for the radiation dose management with the compensation capability of DR system.