• Title/Summary/Keyword: region contrast

Search Result 858, Processing Time 0.034 seconds

Analysis on Factors Relating to External Medical Service Use of Health Insurance Patients Using Spatial Regression Analysis (공간효과분석을 이용한 건강보험 환자 관외 의료이용도와 관련된 요소분석)

  • Roh, Yun Ho
    • Health Policy and Management
    • /
    • v.23 no.4
    • /
    • pp.387-396
    • /
    • 2013
  • Background: The purpose of this study was to analyze the association between areas of Korea Train Express (KTX) region and external medical service use in Korean society using spatial statistical model. Methods: The data which was used in this study was extracted from 2011 regional health care utilization statistics and health insurance key statistics from National Health Insurance Corporation. A total spatial units of 229 districts (si-gun-gu) were included in this study and spatial area was all parts of the country excepted Jeju, Ulleungdo island. We conducted Kruskal-Wallis test, correlation, Moran's I and hot-spot analysis. And after, ordinary linear regression, spatial lag, spatial error analysis was performed in order to find factors which were associated with external medical service use. The data was processed by SAS ver. 9.1 and Geoda095i (windows). Results: Moran's I of health insurance patients' external medical service use was 0.644. Also, population density, Seoul region, doctor factors positively associated with health insurance patients' external medical service. In contrast, average age, health care organization per 100 thousand were negatively associated with health insurance patients' external medical service use. Conclusion: The finding of this study suggested that health insurance patient's external medical service use correlated for seoul region in korea. The study results imply the need for more attention medical needs in the region (si-gun-gu unit) for health insurance patients of seoul region. It is important to adapt strategy to activation of primary health care as well as enhancing public health institution for prevent leakage of patients to other areas.

Seasonal and Regional Effects on Milk Composition of Dairy Cows in South Korea

  • Nam, Ki-Taeg;Kim, Ki-Hyun;Nam, In-Sik;Abanto, Oliver D.;Hwang, Seong-Gu
    • Journal of Animal Science and Technology
    • /
    • v.51 no.6
    • /
    • pp.537-542
    • /
    • 2009
  • For a period of over 6 years, more than 160,000 milk samples were collected and analyzed to determine the influence of different seasonal temperatures and geographic regional location on milk composition in South Korea. Fat, protein, lactose, non fat milk solids (NFMS) and total solids (TS) contents were significantly higher among dairy cows milked in winter season than other seasons (p<0.05). In contrast, freezing point (FP), milk urea nitrogen (MUN) and somatic cell count (SCC) were significantly higher in summer season than other seasons (p<0.05). The average SCC in the autumn season was $358{\times}10^3$/ml, which was lower than any other seasons (p<0.05). These results may be due to the changes in temperature during different seasons. Meanwhile, milk produced by dairy cows in central region had higher fat, protein, lactose, NFMS, TS and MUN and had lower SCC compared to other regions (p<0.05). Fat, TS, FP, MUN and citric acid in northeast region were lower than other regions (p<0.05). The SCC was significantly higher in southeast region than those of other regions (p<0.05). As a result, it might be possible that the differences in feeding management in each different region may affect the milk composition. In conclusion, present results indicated that milk composition is clearly influenced by both season and regional location. Therefore, based on these results, development of different feeding systems, according to season and region is needed to produce high quality and satiable milk production.

The Extraction of ROI(Region Of Interest)s Using Noise Filtering Algorithm Based on Domain Heuristic Knowledge in Breast Ultrasound Image (유방 초음파 영상에서 도메인 경험 지식 기반의 노이즈 필터링 알고리즘을 이용한 ROI(Region Of Interest) 추출)

  • Koo, Lock-Jo;Jung, In-Sung;Choi, Sung-Wook;Park, Hee-Boong;Wang, Gi-Nam
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.31 no.1
    • /
    • pp.74-82
    • /
    • 2008
  • The objective of this paper is to remove noises of image based on the heuristic noises filter and to extract a tumor region by using morphology techniques in breast ultrasound image. Similar objective studies have been conducted based on ultrasound image of high resolution. As a result, efficiency of noise removal is not fine enough for low resolution image. Moreover, when ultrasound image has multiple tumors, the extraction of ROI (Region Of Interest) is not accomplished or processed by a manual selection. In this paper, our method is done 4 kinds of process for noises removal and the extraction of ROI for solving problems of restrictive automated segmentation. First process is that pixel value is acquired as matrix type. Second process is a image preprocessing phase that is aimed to maximize a contrast of image and prevent a leak of personal information. In next process, the heuristic noise filter that is based on opinion of medical specialist is applied to remove noises. The last process is to extract a tumor region by using morphology techniques. As a result, the noise is effectively eliminated in all images and a extraction of tumor regions is possible though one ultrasound image has several tumors.

Estimation of the optimal cultivation area for apples by region

  • Cheong-Ryong Lim;Uhn-Soon Gim;Jae-Hwan Cho
    • Korean Journal of Agricultural Science
    • /
    • v.49 no.2
    • /
    • pp.203-214
    • /
    • 2022
  • A model is developed for estimating optimal cultivation areas for apples to maximize the total profit of apple farming by region, focusing on Gyeongsangbuk-do, Chungchungbuk-do, Gyeongsangnam-do, and Jeonllabuk-do in Korea. Comparing the current cultivation areas to the optimal areas according to the model estimation during the period 1999 - 2019, the former has exceeded the latter since 2015 in all regions except for Jeonllabuk-do. This result stems from a lack of the regulation of production quantity among apple producers' regional organizations. Accordingly, the decreasing rate of the market price was greater than the increasing rate of the production quantity, and the total profit of apple farming has fallen in conjunction with increasing agricultural wage rates. Therefore, in order to reverse the current decreasing trend in the profits of apple farming, it is necessary to regulate nationwide apple cultivation areas through regional producers' associations. Ex-ante forecasting for 2019 posits the following regional optimal cultivation areas for maximizing the total income from apple farming. The Gyeongbuk apple producers' association needs to reduce its current cultivation area by 1,089 ha and to maintain 18,373 ha. In the Chungbuk region, current cultivated area should be reduced by 1,027 ha to maintain 2,722 ha, and in the Gyeongnam region, the current cultivated area should be reduced by 582 ha to maintain 2,730 ha. In contrast, the Jeonbuk region needs to increase its current cultivation area by 174 ha and to maintain at a level of 2,872 ha.

Clinical Feasibility of CT Brain Perfusion in a Dog with Sellar Region Tumor

  • Minji Kim;Gunha Hwang;Jeongmin Ryu;Jiwon Yoon;Moon Yeong Choi;Joong-Hyun Song;Tae Sung Hwang;Hee Chun Lee
    • Journal of Veterinary Clinics
    • /
    • v.41 no.3
    • /
    • pp.178-182
    • /
    • 2024
  • A 10-year-old spayed female Poodle was referred for blindness. On ophthalmic examination, loss of bilateral ocular pupil light reflex, visual loss, and right retinal detachment were confirmed at a local hospital. Magnetic resonance imaging (MRI) of the brain was performed to identify the optic nerve, optic chiasm, and brain disease. A sessile mass centered on the region of the optic chiasm was identified. The mass had iso- to hypointense on fluid-attenuated inversion recovery and T2-weighted images and mildly hypointense on T1-weighted images compared to the gray matter, with strong contrast enhancement. Peripheral edema was also identified. Computed tomography (CT) brain perfusion was performed to obtain additional hemodynamic information about the patient using a multislice CT. CT perfusion showed that the cerebral blood volume in the left temporal lobe region (13.4 ± 1.6 mL/100 g) was decreased relative to the contralateral region (19.9 ± 0.3 mL/100 g). The patient showed decreased appetite and consciousness one week after the CT scan with clinical symptoms worsened. The patient had seizure, tetraparesis, and loss of consciousness. It was euthanized one month later at the request of the owner. This report suggests that CT brain perfusion can provide additional hemodynamic information such as insufficient brain perfusion in sellar region tumor which can help assess potential complications and prognosis and plan treatment.

Color Saturation Improvement using the Maximum Color Difference Table (최대색차신호 표를 이용한 컬러 채도 향상)

  • Kim, Sun-Jung;Hong, Sung-Hoon
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.2
    • /
    • pp.119-130
    • /
    • 2013
  • In this paper, we propose a new color image enhancement method to improve the color saturation as well as luminance contrast in the YCbCr color space. The proposed method uses the maximum color difference table to compensate the perceived saturation changes due to luminance contrast changes. To improve the color saturation, the method first calculates the weighting factor by using the maximum color difference table and then multiplies the weighting factor to the input color difference signals. In this step, it maps color difference signals to proper color region to prevent the color distortion by considering the correlation of color saturations depending on the luminance and hue. The experimental results show that our method effectively improves color saturation compared to the conventional methods.

X-ray Absorptiometry Image Enhancement using Sparse Representation (Sparse 표현을 이용한 X선 흡수 영상 개선)

  • Kim, Hyungil;Eom, Wonyong;Ro, Yong Man
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.10
    • /
    • pp.1205-1211
    • /
    • 2012
  • Recently, the evaluating method of the bone mineral density (BMD) in X-ray absorptiometry image has been studied for the early diagnosis of osteoporosis which is known as a metabolic disease. The BMD, in general, is evaluated by calculating pixel intensity in the bone segmented regions. Accurate bone region extraction is extremely crucial for the BMD evaluation. So, a X-Ray image enhancement is needed to get precise bone segmentation. In this paper, we propose an image enhancement method of X-ray image having multiple noise based sparse representation. To evaluate the performance of proposed method, we employ the contrast to noise ratio (CNR) metric and cut-view graphs visualizing image enhancement performance. Experimental results show that the proposed method outperforms the BayesShrink noise reduction methods and the previous noise reduction method in sparse representation with general noise model.

A Fabrication and Characteristics of 16x8 Reflection Type Symmetric Self Electro-optic Effect Device Array (16x8 반사형 S-SEED 어레이 제작 및 특성)

  • 김택무;이승원;추광욱;김석태;정문식;김성우;권오대;강봉구
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.10
    • /
    • pp.33-40
    • /
    • 1993
  • A reflection type 16x8 S-SEED array from LP(Low Pressure)-MODVD-grown GaAs/AlGaAs extremely shallow quantum well(ESQW) structures, with 4% Al fraction, has been fabricated. Its intrinsic region consists of 50 pairs of alternating 100.angs. GaAs and 100.angs. $Al_{0.04}$Ga$_{0.96}$As layers. A multilayer reflector stack of $Al_{0.04}$/Ga$_{0.96}$ As(599$\AA$)/AlAs(723$\AA$) was incorporated for the reflection plane below the p-i-n structures. The device processing after the MOCVD growth includes the mesa etching, isolation etching, insulator deposition, p & n metallization, and AR(Anti-Reflection) coating. For switching characteristics of the S-SEED in the form of p-i-n ESQW diode, the maximum optical negative resistance was observed at 856nm. Reflectance measurements showed a change from 15.6% to 43.3% for +0.9V to -6V bias. The maximum contrast ration of the S-SEED array was 2.0 and all the 128 devices showed optical bistability with contrast ratios over 2.4 at 5V reverse bias.

  • PDF

Feature values of DWT using MR general imaging and molecular imaging (DWT를 이용한 MR 일반영상과 분자영상 특징추출)

  • Pack, Dae-Sung;Choi, Gui-Rack;Han, Byung-Sung;Ahn, Byung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.409-414
    • /
    • 2012
  • This study acquired molecular lmaging using nano-contrast agents, and the general condition of the same image acquisition to analyze the difference between molecular imaging and general imaging, two images are converted into DWT (Discrete Wavelet Transform). Nano-contrast agent imaging using MRI and molecular imaging using PET study of molecular imaging technology mainstream. DWT analysis of the same lesions using MRI imaging and molecular imaging block lesions are present in the lesions, illustrating the value of a high-frequency feature both highly general imaging and molecular imaging could know that. The high frequency region of the feature extraction values appear higher molecular imaging.

Conceptual Design of Laser Plasma-based Soft X-ray Microscope system for Biomedical Application (레이저 플라즈마 기반의 생물의료용 연 X-선 현미경 설계)

  • 김경우;윤권하
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.690-693
    • /
    • 2003
  • Soft x-ray microscopy provides a unique set of capabilities in-between those of visible light and electron microscopy. It has long been recognized that nature provides a 'water window' spectral region between the K shell x-ray absorption edges of carbon (~290eV) and oxygen (~540eV), where organic materials show strong absorption and phase contrast, while water is relatively non-absorbing. This enables imaging of hydrated biological specimens that are several microns thick with high intrinsic contrast using x-rays with a wavelength of 2.3~4.4nm. Soft X-ray microscopy is therefore well suited to the study of specimens like single biological cells. The most direct advantage of X-ray microscope is their high spatial resolution when compared with visible light microscopes, combined with an ability to image hydrated specimens that are several microns with a minimum of preparation. Our study describes the conceptual design of soft x-ray microscope system based on a laser-based source for biomedical application with high resolution ($\leq$50nm) and short exposure time ($\leq$30sec).

  • PDF