• Title/Summary/Keyword: region contrast

Search Result 858, Processing Time 0.03 seconds

Usefulness Evaluation of Artifacts by Bone Cement of Percutaneous Vertebroplasty Performed Patients and CT Correction Method in Spine SPECT/CT Examinations (척추 뼈 SPECT/CT검사에서 경피적 척추성형술 시행 환자의 골 시멘트로 인한 인공물과 CT보정방법의 유용성 평가)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.49-61
    • /
    • 2014
  • Purpose: With the aging of the population, the attack rate of osteoporotic vertebral compression fracture is in the increasing trend, and percutaneous vertebroplasty (PVP) is the most commonly performed standardized treatment. Although there is a research report of the excellence of usefulness of the SPECT/CT examination in terns of the exact diagnosis before and after the procedure, the bone cement material used in the procedure influences the image quality by forming an artifact in the CT image. Therefore, the objective of the research lies on evaluating the effect the bone cement gives to a SPECT/CT image. Materials and Methods: The images were acquired by inserting a model cement to each cylinder, after setting the background (3.6 kBq/mL), hot cylinder (29.6 kBq/mL) and cold cylinder (water) to the NEMA-1994 phantom. It was reconstructed with Astonish (Iterative: 4 Subset: 16), and non attenuation correction (NAC), attenuation correction (AC+SC-) and attenuation and scatter correction (AC+SC+) were used for the CT correction method. The mean count by each correction method and the count change ratio by the existence of the cement material were compared and the contrast recovery coefficient (CRC) was obtained. Additionally, the bone/soft tissue ratio (B/S ratio) was obtained after measuring the mean count of the 4 places including the soft tissue(spine erector muscle) after dividing the vertebral body into fracture region, normal region and cement by selecting the 20 patients those have performed PVP from the 107 patients diagnosed of compression fracture. Results: The mean count by the existence of a cement material showed the rate of increase of 12.4%, 6.5%, 1.5% at the hot cylinder of the phantom by NAC, AC+SC- and AC+SC+ when cement existed, 75.2%, 85.4%, 102.9% at the cold cylinder, 13.6%, 18.2%, 9.1% at the background, 33.1%, 41.4%, 63.5% at the fracture region of the clinical image, 53.1%, 61.6%, 67.7% at the normal region and 10.0%, 4.7%, 3.6% at the soft tissue. Meanwhile, a relative count reduction could be verified at the cement adjacent part at the inside of the cylinder, and the phantom image on the lesion and the count increase ratio of the clinical image showed a contrary phase. CRC implying the contrast ratio and B/S ratio was improved in the order of NAC, AC+SC-, AC+SC+, and was constant without a big change in the cold cylinder of the phantom. AC+SC- for the quantitative count, and AC+SC+ for the contrast ratio was analyzed to be the highest. Conclusion: It is considered to be useful in a clinical diagnosis if the application of AC+SC+ that improves the contrast ratio is combined, as it increases the noise count of the soft tissue and the scatter region as well along with the effect of the bone cement in contrast to the fact that the use of AC+SC- in the spine SPECT/CT examination of a PVP performed patient drastically increases the image count and enables a high density of image of the lesion(fracture).

  • PDF

The Evaluation of SUV Using with and without Correction for Effect of Contrast Media in Whole Body PET/CT Imaging (전신 PET/CT 영상에서 조영제 영향의 보정 유.무에 따른 SUV 평가)

  • Nam, So-Ra;Son, Hye-Kyung;Lim, Han-Sang;Park, Hoon-Hee;Cho, Hyo-Min;Lee, Chang-Lae;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.246-251
    • /
    • 2006
  • The purpose of this study was to evaluate SUV (standard uptake value) using different reconstruction methods in whole body PET/CT Imaging. PET/CT studies were peformed with and without correction for effect of contrast media. The patients data were acquired using GE DSTe commercial PET/CT system. The liver disease (hepatocellular carcinoma, HCC) and renal disease (renal ceil carcinoma, RCC) patients were selected for this study, The PET/CT data were reconstructed using post CT scan with and without correction for effect of contrast media. We selected ROIs (region of Interest) at the same location and same area for the same patient to compare SUVs in these two methods. For HCC and RCC, the average differences of SUVs were measured as $1.5{\pm}1.2%\;and\;1.0{\pm}0.9%$, respectively. For HCC and RCC, the maximum differences of SUVs were measured as 4.3% and 1.9%, respectively. We observed that SUVs without correction for effect of contrast media were higher than SUVs with correction for effect of contrast media. However the differences of SUVs were very minimal. These results may be limited to HCC and RCC and further studies will be Heeded for other organs or diseases to see any changes in SUV with and without correction for effect of contrast media.

  • PDF

MAGNETIC CURTAILMENT OF THE SHOCK-INDUCED THERMAL INSTABILITY

  • Hong, Seung-Soo;Koo, Bon-Chul
    • Journal of The Korean Astronomical Society
    • /
    • v.17 no.2
    • /
    • pp.115-125
    • /
    • 1984
  • Effect of magnetic field on the thermal instability is studied in the radiatively cooling region behind an interstellar shock of moderate propagation velocity (${\sim}10\;km/sec$). It is shown that the presence of interstellar magnetic field of a few micro gauss is very effective in preventing the thermal instability from building-up density concentration. In the absence of magnetic field, the shock-induced thermal instability amplifies preshock density inhomogeneity by more than an order of magnitude. However, in the presence of magnetic field, the amplified density contrast is shown to be only a factor 2.

  • PDF

An Effective Detection of Bimean and its Application into Image Segmentation by an Interative Algorithm Method (반복적인 알고리즘 방법에 의한 효과적인 양평균 검출 및 영상분할에 응용)

  • Heo, Pil-U
    • 연구논문집
    • /
    • s.25
    • /
    • pp.147-154
    • /
    • 1995
  • In this paper, we discussed the convergence and the properties of an iterative algorithm method in order to improve a bimean clustering algorithm. This algorithm that we have discussed choose automatically an optimum threshold as a result of an iterative process, successive iterations providing increasingly cleaner extractions of the object region, The iterative approach of a proposed algorithm is seen to select an appropriate threshold for the low contrast images.

  • PDF

Local Feature Detection on the Ocular Fundus Fluorescein angiogram Using Relaxation Process (이완법을 이용한 형광안저화상의 국소특징 검출)

  • 高昌林
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.5
    • /
    • pp.856-862
    • /
    • 1987
  • An local adaptive image segmentatin algorithm for local feature detection and effective clustering of unimodal histogram shape are proposed. Local adaptive difference image and its histogram are obtained from the input image. The parameters are derived from the histogram and used for the segmentation based on relaxatin process. The results showed effective region segmentation and good noise cleaning for the ocular fundus fluorescein angiogram which has low contrast and unimodal histogram.

  • PDF

Effects of Ginsenoside Rg1 on the Expression of TNF-$\alpha$ from Rat microglia

  • Joo, Seong-Soo;Won, Tae-Joon;Lee, Do-Ik
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.202.1-202.1
    • /
    • 2003
  • Microglial cell can act for phagocytosis against abnormal particles in brain, which means that beta-amyloid produced from APP(amyloid precursor protein) can be phagocytosed by microglia when released. In contrast. when senile plaque has already been formed in brain cortex and hippocamphal region, microglia can also accelerate the AD pathogenesis due to chronic inflammatory action, which lead to neuron cell cytotoxicity. (omitted)

  • PDF

The study of Breast Specific Gamma Imaging Protocol using Self-development Phantom (자체 제작된 팬텀을 적용한 Breast Specific Gamma Imaging 검사 프로토콜에 대한 고찰)

  • Lee, Hae-Jung;Lee, Juyoung;Lim, Kuen-Kyo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.39-47
    • /
    • 2014
  • Purpose As breast cancer patients continue to increase every year, cases of BSGI are on the rise with a heavier reliance on it. However, BSGI protocol in hospitals was not studied enough despite it was covered by hospital's condition and recommendation of manufacturers. The objective of the study was an examination of methods to be applicable to BSGI protocols, putting the self-development phantom to use in quality assessment of the images. Materials and Methods Dilon 6800 (Dilon Technologies Inc, Newport News, USA) was used in the study and five different sizes of sphere were distinctively produced in the phantom. The study used $^{99m}TcO_4$. The cases were classified in to three categories that background radioactivity to region of interest as ratio of 2: 4: 8, They were acquired images for 5, 7, 10mins. The acquired image was set region of interest according to the size of sphere, and We analyzed quantitative and qualitative analysis. The acquired data statistically analyzed with SPSS ver.18.0. Results As the result of quantitative and qualitative analysis, count rate of each sphere in accordance with difference of injection dose showed that higher count rate as injection dose and sphere size increased (P<0.005). Count rate of each sphere in accordance with difference of acquisition time showed that higher count rate as acquisition time and sphere size increased (P<0.005). Contrast noise ratio of each sphere in accordance with difference of injection dose showed that higher contrast noise ratio as injection dose increased. Particularly, Contrast noise ratio of eight times ratio images was the highest among. Contrast noise ratio of each sphere in accordance with difference of acquisition time showed that higher contrast noise ratio as acquisition time increased. And, Contrast noise ratio of seven minute image was the highest among (P<0.005). Conclusion There was significant change of Contrast noise ratio through quantitative and qualitative analysis. Moreover, We found usefulness of phantom. If Institutions identified image through the phantom study and they made BSGI protocol, We expected to help the improvement of diagnostic value of the images.

  • PDF

A Saliency-Based Focusing Region Selection Method for Robust Auto-Focusing

  • Jeon, Jaehwan;Cho, Changhun;Paik, Joonki
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.1 no.3
    • /
    • pp.133-142
    • /
    • 2012
  • This paper presents a salient region detection algorithm for auto-focusing based on the characteristics of a human's visual attention. To describe the saliency at the local, regional, and global levels, this paper proposes a set of novel features including multi-scale local contrast, variance, center-surround entropy, and closeness to the center. Those features are then prioritized to produce a saliency map. The major advantage of the proposed approach is twofold; i) robustness to changes in focus and ii) low computational complexity. The experimental results showed that the proposed method outperforms the existing low-level feature-based methods in the sense of both robustness and accuracy for auto-focusing.

  • PDF

The Concentrations of Heavy Metals in the Seawater, Sediment and Seaweed in Mokpo Coastal Region, Southwestern Coast of Korea (목포 연안해역의 해수, 퇴적물 및 해조류에 축적된 중금속 함량)

  • Park, Chan-Sun;Wi, Mi-Young;Hwang, Eun-Kyoung
    • Korean Journal of Environmental Biology
    • /
    • v.26 no.4
    • /
    • pp.303-310
    • /
    • 2008
  • Heavy metal concentration of Fe, Zn, Cu, Cd and Pb were analysed from seaweeds (Ulva pertusa, Sargassum thunbergii, Caulacanthus okamurae), sediments and seawater at the two experimental sites of Daebul and Sabjin industrial complex in Mokpo coastal area with a control site (Heugsando). Highest values of heavy metals were found at two experimental sites influencing by various pollution sources such as industrial drains, sewage and harbours. In contrast, the lowest concentrations was observed at the control site without any pollution source. The concentration levels of accumulated heavy metals were in the following order: seaweeds > sediments > seawater. Similar spatial distribution patterns were observed at the seaweeds, sediments and seawater for the highest mean values of the different heavy metals. This result show that seaweeds could be used as a biomonitors of heavy metals at coastal region.

Text Detection based on Edge Enhanced Contrast Extremal Region and Tensor Voting in Natural Scene Images

  • Pham, Van Khien;Kim, Soo-Hyung;Yang, Hyung-Jeong;Lee, Guee-Sang
    • Smart Media Journal
    • /
    • v.6 no.4
    • /
    • pp.32-40
    • /
    • 2017
  • In this paper, a robust text detection method based on edge enhanced contrasting extremal region (CER) is proposed using stroke width transform (SWT) and tensor voting. First, the edge enhanced CER extracts a number of covariant regions, which is a stable connected component from input images. Next, SWT is created by the distance map, which is used to eliminate non-text regions. Then, these candidate text regions are verified based on tensor voting, which uses the input center point in the previous step to compute curve salience values. Finally, the connected component grouping is applied to a cluster closed to characters. The proposed method is evaluated with the ICDAR2003 and ICDAR2013 text detection competition datasets and the experiment results show high accuracy compared to previous methods.