• Title/Summary/Keyword: region contrast

Search Result 858, Processing Time 0.037 seconds

Lyotropic Mesomorphisms of a Lamellar Liquid Crystalline Phase in Non-hydrous Condition: A Phospholipid Hydrated by Different Polar Solvents

  • Lee, Dong-Kyu;Jeong, Kwan-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1165-1171
    • /
    • 2010
  • The lyotropic mesomorphism of lamellar liquid crystalline phase was examined by observing the swelling behavior of Distearoylphosphatidylcholine(DSPC) in glycerin and panthenol without water. The lyotropic mesomorphism was examined by using DSC, XRDs and Cryo-SEM. Increase of two polar solvents under non-hydrous condition showed distinctive differences in the lyotropic mesomorphism from forming different anisotropic structures with DSPC. Glycerin did not affect to the crystalline region of lamellar phase, whereas typical swelling mesomorphism was shown in the noncrystalline region. In contrast, panthenol showed some effect on the crystalline region, but common swelling mesomorphism was found in the non-crystalline region. In this case, the isopropyl and propyl groups in panthenol were the main factor to affect to the lipophilic domain in the crystalline region of lamellar phase. Also, it was found that the formation of well-arranged lamellar structure only by introducing glycerin and panthenol as a solvent without water, was possible. These results were confirmed by examination of the swelling mesomorphism of liquid crystal membrane triggered by introducing the two polar solvents.

Salient Object Extraction from Video Sequences using Contrast Map and Motion Information (대비 지도와 움직임 정보를 이용한 동영상으로부터 중요 객체 추출)

  • Kwak, Soo-Yeong;Ko, Byoung-Chul;Byun, Hye-Ran
    • Journal of KIISE:Software and Applications
    • /
    • v.32 no.11
    • /
    • pp.1121-1135
    • /
    • 2005
  • This paper proposes a moving object extraction method using the contrast map and salient points. In order to make the contrast map, we generate three-feature maps such as luminance map, color map and directional map and extract salient points from an image. By using these features, we can decide the Attention Window(AW) location easily The purpose of the AW is to remove the useless regions in the image such as background as well as to reduce the amount of image processing. To create the exact location and flexible size of the AW, we use motion feature instead of pre-assumptions or heuristic parameters. After determining of the AW, we find the difference of edge to inner area from the AW. Then, we can extract horizontal candidate region and vortical candidate region. After finding both horizontal and vertical candidates, intersection regions through logical AND operation are further processed by morphological operations. The proposed algorithm has been applied to many video sequences which have static background like surveillance type of video sequences. The moving object was quite well segmented with accurate boundaries.

Fluoride single crystals for UV/VUV nonlinear optical applications

  • Shimamura Kiyoshi;Villora Encarnacion G.;Muramatsu Kenichi;Kitamura Kenji;Ichinose Noboru
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.16 no.4
    • /
    • pp.133-140
    • /
    • 2006
  • The growth characteristics and properties of large size $SrAlF_5$ single crystals are described and compared with those of $BaMgF_4$. Transmission spectra in the vacuum ultraviolet wavelength region indicate a high transparency of $SrAlF_5$ (about 90% without considering surface reflection loses) down to 150 nm, on contrast to the optical loses observed for $BaMgF_4$. The ferroelectric character of $SrAlF_5$ is evidenced by the reversal of the spontaneous polarization in a hysteresis loop. The higher potential of $SrAlF_5$ in comparison with $BaMgF_4$ for the realization of all-solid-state lasers in the ultraviolet wavelength region by the quasi-phase matching (QPM) technique is pointed out. $SrAlF_5$, besides a higher grade of transparency, shows a nonlinear effective coefficient similar to that of quartz and uniaxial nature, on contrast to the one order smaller nonlinear coefficient and biaxial character of $BaMgF_4$. The refractive index of $SrAlF_5$ from the ultraviolet to the near-infrared wavelength region is measured by the minimum deviation method. The Sellmeier and Cauchy coefficients are obtained from the fits to the curves of the ordinary and extraordinary refractive indices, and the grating period for the first order QPM is estimated as a function of the wavelength. The poling periodicity for 193 nm SHG from 386 nm is $4{\mu}m$.

Evaluation of imaging reformation with cone beam computed tomography for the assessment of bone density and shape in mandible (Cone beam형 전산화단층영상에서 골의 형태와 밀도의 평가)

  • Hong, Sang-Woo;Kim, Gyu-Tae;Choi, Yon-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.38 no.1
    • /
    • pp.49-56
    • /
    • 2008
  • Purpose: Diagnostic estimation of destruction and formation of bone has the typical limit according to capacity of x-ray generator and image detector. So the aim of this study was to find out how much it can reproduce the shape and the density of bone in the case of using recently developed dental type of cone beam computed tomography, and which image is applied by new detector and mathematic calculation. Materials and Methods: Cone beam computed tomography (PSR 9000N, Asahi Roentgen Ind. Co., Ltd., Japan) and soft x-ray radiography were executed on dry mandible that was already decalcified during 5 hours, 10 hours, 15 hours, 20 hours, and 25 hours. Estimating and comparing of those came to the following results. Results: The change of inferior border of mandible and anterior border of ramus in the region of cortical bone was observed between first 5 and 10 hours of decalcification. The reproduction of shape and density in the region of cortical bone and cancellous bone can be hardly observed at cone beam computed tomography compared with soft x-ray radiography. The difference of decrease of bone density according to hours of decalcification increase wasn't reproduced at cone beam computed tomography compared with soft x-ray radiography. Conclusion: CBCT images revealed higher spatial resolution. However, contrast resolution in region of low contrast sensitivity is the inferiority of images' property.

  • PDF

Unifocal Langerhans Cell Histiocytosis of Frontal Bone in a Child (소아 전두골에 발생한 랑게르한스세포 조직구증)

  • Hong, Seong Jae;Cho, Sang Hun;Eo, Su Rak
    • Archives of Craniofacial Surgery
    • /
    • v.14 no.1
    • /
    • pp.69-72
    • /
    • 2013
  • Lateral eyebrow mass with primary skull lesion are rare in pediatric population. Although epidermoid cyst and dermoid cyst are the most commonly encountered skull lesions in pediatric population, Langerhans cell histiocytosis (LCH) is rarely reported. We report a case of LCH arising from the lateral eyebrow with osteolytic lesion involving the frontal bone. A 5-year-old boy was presented with a hard, fixed mass in his lateral eyebrow. Contrast magnetic resonance imaging revealed inhomogeneous enhancement of the mass with direct invasion of the frontal bone and adjacent dura mater. Under general anesthesia, linear incision at the lateral eyebrow region was made. Intraoperative evaluation revealed hard, fixed and well-defined soft tissue mass. The final extirpated mass was $2.5{\times}2.4cm$ in size, and was accompanied by a $1{\times}1cm$ sized defect on the frontal bone with intact dura mater. The surgical wound was closed primarily by a layer-by-layer fashion. Histologic examination was later performed for definite diagnosis. The histologic examination revealed abnormal proliferation of Langerhans cell with granuloma formation. Radionuclide bone scan and positron emission tomography was taken and revealed free of multi-organ involvement. At 3 months after surgery, natural looking contour at the lateral eyebrow region was observed with no tumor recurrence. Differential diagnosis of the hard and fixed mass at the lateral eyebrow region affecting the primary skull lesion from pediatric population includes epidermoid cyst, dermoid cyst and LCH. Generally, brief physical examination with plain X-ray view can be performed for clinical evaluation, but for a definite diagnosis, contrast MRI may be helpful.

Medkum TAu Inversion Recover(MTIR) Sequence for White Matter Suppression in Brain Cortical Lesions (뇌피질 질환에서 뇌백질 신호 억제를 위한 중간시간 반전회복 영상 기법)

  • 정경호;이정민;김종수
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.1
    • /
    • pp.60-65
    • /
    • 1999
  • Purpose : The purpose of this study was to evaluate the image quality, contrast characteristics, and possible clinical utility of Medium Tau Inversion Recovery(MTIR) sequence with white matter suppression in patients with brain cortical lesion. Materials and methods : Two normal volunteers and twenty-one patients with cortical lesion were scanned with MTIR as well as other MR imaging sequences. Gray-white matter contrast was evaluated objectively using region-of-interest calculations, including percent contrast and contrast-to-noise ratio(CNR). MTIR sequence was visually compared with other sequences in 21 patients with cortical lesion including conspicuity and detection rate. Results : MTIR sequence had the highest present contrast and CNR between the gray matter and white matter. In twenty-one cases of cortical lesion including cortical dysplasia, MTIR sequence improved delineation and conspicuity of lesion, but MTIR sequence could not detect new lesions. Conclusion : The MTIR sequence well delineated the cortical lesions, particularly in including cortical dysplasia. It may be used as an adjunctive imaging sequence in case of poor gray and white matter differentiation with conventional T1-weighted sequences.

  • PDF

Effect of Supratentorial Stroke on Cerebellar Hemodynamic Parameters - Assessment by Dynamic Susceptibility Contrast MR Imaging (천막상부 뇌졸중에서 소뇌의 혈역학 변화 -Dynamic Susceptibility Contrast MR 영상을 이용한-)

  • Han, Si-Ryung;Kim, Bum-Soo;Guak, Tae-Ho;Choi, Young-Bin;Kim, Yeong-In
    • Annals of Clinical Neurophysiology
    • /
    • v.4 no.1
    • /
    • pp.38-43
    • /
    • 2002
  • Background & Purpose : Dynamic susceptibility contrast MR imaging, one method of perfusion MRI, was developed to define cerebral hemodynamic status with good anatomical resolution. The authors investigated hemodynamic parameters using this imaging method, in an effort to identify hemodynamic changes on the remote crossed cerebellum of patients with a supratentorial infarct. Methods : Dynamic susceptibility contrast MR imaging was performed in 15 patients with only unilateral supratentorial infarcts. Imaging was obtained at the anatomic level of the cerebellum. rCBF, rCBV, MTT and TP were determined over both cerebellar hemispheres of interest. Results : The rCBF and rCBV values of the contralateral cerebellar hemisphere were significantly more decreased than those of the ipsilateral cerebellar hemisphere in 12 patients(p=0.028, 0.033). MTT and TP values of the contralateral and ipsilateral cerebellar hemispheres didn't reveal any differences(p=0.130, 0.121). Conclusions : The results of this work suggest that the region which are remote from the ischemic brain lesion shows no changes of MTT or TP but show decrease of rCBF and rCBV, mean to diaschisis, it also demonstrates that perfusion MRI is an easily available method to evaluate the hemodynamic status of the brain.

  • PDF

Adaptive Contrast Enhancement in DCT Domain (DCT영역에서의 적응적 대비 개선에 관한 연구)

  • Jeon, Yong-Joon;Eom, Min-Young;Choe, Yoon-Sik
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.5 s.305
    • /
    • pp.73-78
    • /
    • 2005
  • Images coded by DCT based compression contain several quality degradations by quantization process. Among them contrast distortion is the important one because human eyes are sensitive to contrast. In case of low bit-rate coded image, we can not get an image having good quality due to quantization error. In this paper, we suggest a new scheme to enhance image's contrast in DCT domain. Proposed method enhances only edge regions. Homogeneous regions are not considered in this method. $8{\times}8$ DCT coefficient blocks are decomposed to $4{\times}4$ sub-blocks for detail edge region discrimination. we could apply this scheme to real-time application because proposed scheme is DCT based method.

Prediction of successful caudal epidural injection using color Doppler ultrasonography in the paramedian sagittal oblique view of the lumbosacral spine

  • Yoo, Seon Woo;Ki, Min-Jong;Doo, A Ram;Woo, Cheol Jong;Kim, Ye Sull;Son, Ji-Seon
    • The Korean Journal of Pain
    • /
    • v.34 no.3
    • /
    • pp.339-345
    • /
    • 2021
  • Background: Ultrasound-guided caudal epidural injection (CEI) is limited in that it cannot confirm drug distribution at the target site without fluoroscopy. We hypothesized that visualization of solution flow through the inter-laminar space of the lumbosacral spine using color Doppler ultrasound alone would allow for confirmation of drug distribution. Therefore, we aimed to prospectively evaluate the usefulness of this method by comparing the color Doppler image in the paramedian sagittal oblique view of the lumbosacral spine (LS-PSOV) with the distribution of the contrast medium observed during fluoroscopy. Methods: Sixty-five patients received a 10-mL CEI of solution containing contrast medium under ultrasound guidance. During injection, flow was observed in the LSPSOV using color Doppler ultrasonography, following which it was confirmed using fluoroscopy. The presence of contrast image at L5-S1 on fluoroscopy was defined as "successful CEI." We then calculated prediction accuracy for successful CEI using color Doppler ultrasonography in the LS-PSOV. We also investigated the correlation between the distribution levels measured via color Doppler and fluoroscopy. Results: Prediction accuracy with color Doppler ultrasonography was 96.9%. The sensitivity, specificity, positive predictive value, and negative predictive value were 96.7%, 100%, 100%, and 60.0%, respectively. In 52 of 65 patients (80%), the highest level at which contrast image was observed was the same for both color Doppler ultrasonography and fluoroscopy. Conclusions: Our findings demonstrate that color Doppler ultrasonography in the LS-PSOV is a new method for determining whether a drug solution reaches the lumbosacral region (i.e., the main target level) without the need for fluoroscopy.

Hybrid Tone Mapping Technique Considering Contrast and Texture Area Information for HDR Image Restoration (HDR 영상 복원을 위해 대비와 텍스쳐 영역 정보를 고려한 혼합 톤 매핑 기법)

  • Kang, Ju-Mi;Park, Dae-Jun;Jeong, Jechang
    • Journal of Broadcast Engineering
    • /
    • v.22 no.4
    • /
    • pp.496-508
    • /
    • 2017
  • In this paper, we propose a Tone Mapping Operator (TMO) that preserves global contrast and precisely preserves boundary information. In order to reconstruct a High Dynamic Range (HDR) image to a Low Dynamic Range (LDR) display by using Threshold value vs. Intensity value (TVI) based on Human Visual System (HVS) and contrast value. As a result, the global contrast of the image can be preserved. In addition, by combining the boundary information detected using Guided Image Filtering (GIF) and the detected boundary information using the spatial masking of the Just Noticeable Difference (JND) model, And improved the perceived image quality of the output image. The conventional TMOs are classified into Global Tone Mapping (GTM) and Local Tone Mapping (LTM). GTM preserves global contrast, has the advantages of simple implementation and fast execution time, but it has a disadvantage in that the boundary information of the image is lost and the regional contrast is not preserved. On the other hand, the LTM preserves the local contrast and boundary information of the image well, but some areas are expressed unnatural like the occurrence of the halo artifact phenomenon in the boundary region, and the calculation complexity is higher than that of GTM. In this paper, we propose TMO which preserves global contrast and combines the merits of GTM and LTM to preserve boundary information of images. Experimental results show that the proposed tone mapping technique has superior performance in terms of cognitive quality.