• Title/Summary/Keyword: regenerative design

Search Result 201, Processing Time 0.027 seconds

A Study on Regenerative Cooling System for Thrust Chamber Protection (연소실 보호를 위한 재생냉각 방식 연구)

  • Park, Hee-Ho;Kim, Jung-Hun;Choi, Young-Hwan;Kim, Yoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.3
    • /
    • pp.78-85
    • /
    • 2005
  • The purpose of the study was to establish the design procedure and develop the program for designing regenerative cooling system. To obtain the design parameter necessary for the realization of regenerative cooling system, water-cooled regenerative cooling system was designed from suggested procedure. To compare experimental results with a present method of analytically predicting the heat transfer loads, $250kg_{f}$ experimental LRE with water-cooled regenerative cooling system was investigated. Based on the investigation, the good correction between the predicted and measured data was verified. Developed design program can be used to designing Kerosene- cooled regenerative cooling system. The basic experimental data and correlations obtained in this study for 250kgf experimental LRE with water-cooled regenerative cooling system can be directly applicable to the real LRE.

Design of Super-regenerative Oscillator for Ultra Low Power Receiver Implementation (극소전력 수신기 구현을 위한 Super-regenerative Oscillator 설계)

  • Kim, Jeong-Hoon;Kim, Jung-Jin;Kim, Eung-Ju;Park, Ta-Jun
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.625-626
    • /
    • 2006
  • An Ultra low power super-regenerative oscillator was implemented with on-chip inductor and quench signal generator. The super-regenerative oscillator detects the signal level as low as -70dBm while consuming only 0.48mA at 1.5V supply voltage. These results indicate that the super-regenerative oscillator can be outstanding candidate the simple, ultra low power receiver design.

  • PDF

Performance Test for a Horizontal Regenerative Evaporative Cooler (수평형 재생증발식 냉방기의 성능시험)

  • Song, Gwi-Eun;Lee, Dae-Young
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.621-626
    • /
    • 2006
  • Regenerative evaporative cooling is known as an environment-friendly and energy efficient cooling method. A regenerative evaporative cooler (REC) consisting of dry and wet channels is able to cool down the air stream below the inlet wet-bulb temperature. In the regenerative evaporative cooler, the cooling effect is achieved by redirecting a portion of the air flown out of the dry channel into the wet channel and spraying water onto the redirected air. In this study, a horizontal regenerative cooler is considered. In the horizontal regenerative cooler, the flow direction of evaporating water has a right angle to the flow direction of supply air. This difference was investigated with visualization technique and simplified 2-module performance test was done in a thermo-environment chamber. Optimum design configuration is changed due to the wet channel which are easily fully covered with evaporating water and block the air flow inside the channel. Applying the optimized fin configuration design with the highly wetting surface treatment, a regenerative evaporative cooler was fabricated and tested to Identify the cooling performance improvement and operation characteristics. From the experimental results at the intake condition of $32^{\circ}C$ and 50% RH, the supply temperature was measured to be around $23.4^{\circ}C$. The cooling effectiveness based on the inlet dewpoint temperature was evaluated 73% which is almost close to the design expectation.

  • PDF

Development of An Integrated Optimal Design Program for Design of A High-Efficiency Low-Noise Regenerative Fan (재생형 송풍기의 고효율 저소음 설계를 위한 통합형 최적설계 프로그램 개발)

  • Heo, Man-Woong;Kim, Jin-Hyuk;Seo, Tae-Wan;Koo, Gyoung-Wan;Lee, Chung-Suk;Kim, Kwang-Young
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.1
    • /
    • pp.35-40
    • /
    • 2014
  • A multi-objective optimization of a regenerative fan for enhancing the aerodynamic and aeroacoustic performance was carried out using an integrated fan design system, namely, Total FAN-Regen$^{(R)}$. The Total FAN-Regen$^{(R)}$ was developed for non-specialists to carry out a series of design process, viz., computational preliminary design, three-dimensional aerodynamic and aeroacoustic analyses, and design optimization, for a regenerative fan. An aerodynamic analysis of the regenerative fan was conducted by solving three-dimensional Reynolds-averaged Navier-Stokes equations using the shear stress transport turbulence model. And, an aeroacoustic analysis of the regenerative fan was implemented in a finite/infinite element method by solving the variational formulation of Lighthill's analogy based on the results of the unsteady flow analysis. An optimum shape obtained by Total FAN-Regen$^{(R)}$ shows the enhanced efficiency and decreased sound pressure level as much as 1.5 % and 20.0 dB, respectively, compared to those of the reference design. The performance test was carried out for an optimized regenerative fan to validate the performance of the numerically predicted optimal design.

Hydraulic Design Procedure for Regenerative Flow Pumps (재생형 펌프의 수력학적 설계)

  • Yoo, Il-Su;Park, Mu-Ryong;Chung, Myoung-Kyoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.1 s.244
    • /
    • pp.16-23
    • /
    • 2006
  • The present study aims at establishing the design procedure of regenerative pumps. It is based on the new momentum exchange theory proposed in Yoo, Park and Chung. Salient feature of the present design procedure is that it does not require input of any kinds of empirical design data. Using the design procedure, a prototype regenerative pump has been designed and manufactured to confirm its validity. Comparison between the predicted performance and the experimental measurement reveals that the prototype pump has its maximum efficiency at the design flow rate and that the proposed performance analysis method satisfactorily predicts the machine performance.

Performance Enhancement of 20kW Regenerative Blower Using Design Parameters

  • Jang, Choon-Man;Jeon, Hyun-Jun
    • International Journal of Fluid Machinery and Systems
    • /
    • v.7 no.3
    • /
    • pp.86-93
    • /
    • 2014
  • This paper describes performance enhancement of a regenerative blower used for a 20 kW fuel cell system. Two design variables, bending angle of an impeller and blade thickness of an impeller tip, which are used to define an impeller shape, are introduced to enhance the blower performance. Internal flow of the regenerative blower has been analyzed with three-dimensional Navier-Stokes equations to obtain the blower performance. General analysis code, CFX, is introduced in the present work. SST turbulence model is employed to estimate the eddy viscosity. Throughout the numerical analysis, it is found that the thickness of impeller tip is effective to increase the blower efficiency in the present blower. Pressure is successfully increased up to 2.8% compared to the reference blower at the design flow condition. And efficiency is also enhanced up to 2.98 % compared to the reference one. It is noted that low velocity region disturbs to make strong recirculation flow inside the blade passages, thus increases local pressure loss. Detailed flow field inside the regenerative blower is also analyzed and compared.

Performance Evaluation of Side Channel Type Regenerative Blower (사이드채널형 재생블로워의 성능평가)

  • Lee, Kyoung-Yong;Choi, Young-Seok
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.378-383
    • /
    • 2005
  • The performances of side channel type regenerative blowers were evaluated by the blower performance test, 1-D performance prediction and CFD. The performance prediction method was modified using the results of the performance test and CFD and applied to the design of the new regenerative blowers. The major geometric parameters such as channel height, channel area and expansion angle were decided from the performance prediction method for the improved models and the predicted results were compared with CFD and experimental data. Both of the modified models showed improved efficiency at the operating condition. Especially, model3 could be possible to reduce operating rotating speed, that is benefit to noise performance, because of the high head performance at the design point. The CFD results showed that the performance of the regenerative blower was influenced by the secondary circulatory flow in the channel.

  • PDF

Development of Regenerative Braking Control Algorithm for a 4WD Hybrid Electric Vehicle (4WD HEV의 회생제동 제어로직 개발)

  • Yeo Hoon;Kim Donghyun;Kim Talchol;Kim Chulsoo;Hwang Sungho;Kim Hyunsoo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.6
    • /
    • pp.38-47
    • /
    • 2005
  • In this paper, a regenerative braking algorithm is proposed to make the maximum use of the regenerative braking energy for an independent front and rear motor drive parallel HEV. In the regenerative braking algorithm, the regenerative torque is determined by considering the motor capacity, motor efficiency, battery SOC, gear ratio, clutch state, engine speed and vehicle velocity. To implement the regenerative braking algorithm, HEV powertrain models including the internal combustion engine, electric motor, battery, manual transmission and the regenerative braking system are developed using MATLAB, and the regenerative braking performance is investigated by the simulator. Simulation results show that the proposed regenerative braking algorithm contributes to increasing the battery SOC, which recuperates 60 percent of the total braking energy while satisfying the design specification of the control logic. In addition, a control algorithm which limits the regenerative braking is suggested by considering the battery power capacity and dynamic response characteristics of the hydraulic control module.

Preliminary Design Plan for Determining Combustor Configuration of Regenerative-cooled Liquid Rocket Engine (재생냉각식 액체로켓엔진의 연소기 형상 결정을 위한 예비 설계 방안)

  • Son, Min;Seo, Min-Kyo;Koo, Ja-Ye;Cho, Won-Kook;Seol, Woo-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.1
    • /
    • pp.83-89
    • /
    • 2011
  • A design plan was proposed for determining combustor configuration of regenerative- cooled liquid rocket engine in the process of preliminary design. Rocket performance and regenerative cooling results were calculated using the properties of combustion gas estimated in CEA. For required thrust, chamber pressure, atmosphere pressure and propellant mixture ratio the mass flow rate of propellants and combustor performance were predicted by one-dimensional and experimental correlations. Finally, determinable plan for the contour of combustor were presented through Rao nozzle design method.

Preliminary Design Plan for Determining Combustor Configuration of Regenerative-cooled Liquid Rocket Engine (재생냉각식 액체로켓엔진의 연소기 형상 결정을 위한 예비 설계 방안)

  • Son, Min;Seo, Min-Kyo;Koo, Ja-Ye;Cho, Won-Kook;Seol, Woo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.37-42
    • /
    • 2010
  • A design plan was proposed for determining combustor configuration of regenerative- cooled liquid rocket engine in the process of preliminary design. Rocket performance and regenerative cooling results were calculated using the properties of combustion gas estimated in CEA. For required thrust, chamber pressure, atmosphere pressure and propellant mixture ratio the mass flow rate of propellants and combustor performance were predicted using one-dimensional and experimental equations. Finally, determinable plan for contour of combustor were presented through Rao nozzle design method.

  • PDF