• 제목/요약/키워드: references values

Search Result 147, Processing Time 0.025 seconds

Correction and Experimental Verification of Velocity Circulation in a Double-blade Pump Impeller Outlet

  • Kai, Wang;Qiong, Liu
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.4
    • /
    • pp.311-317
    • /
    • 2015
  • It is difficulty to calculate velocity circulation in centrifugal pump impeller outlet accurately. Velocity circulations of a double-blade pump impeller outlet were calculated with Stodola formula, Weisner formula and Stechkin formula. Simultaneously, the internal flow of impeller for the double-blade pump were measured with PIV technology and average velocity circulations at the 0.8, 1.0 and 1.2 times of design flow were obtained. All the experimental values were compared with the above calculation values at the three conditions. The results show that calculation values of velocity circulations with Weisner formula is close to the experimental values. On the basis of the above, velocity circulations of impeller outlet were corrected. The results of experimental verification show that the corrected calculation errors, whose maximum error is 3.65%, are greatly reduced than the uncorrected calculation errors. The research results could provide good references for establishment of theoretical head and multi-condition hydraulic optimization of double-blade pumps.

On-Chip Full CMOS Current and Voltage References for High-Speed Mixed-Mode Circuits (고속 혼성모드 집적회로를 위한 온-칩 CMOS 전류 및 전압 레퍼런스 회로)

  • Cho, Young-Jae;Bae, Hyun-Hee;Jee, Yong;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.3
    • /
    • pp.135-144
    • /
    • 2003
  • This work proposes on-chip full CMOS current and voltage references for high-speed mixed-mode circuits. The proposed current reference circuit uses a digital-domain calibration method instead of a conventional analog calibration to obtain accurate current values. The proposed voltage reference employs internal reference voltage drivers to minimize the high-frequency noise from the output stages of high-speed mixed-mode circuits. The reference voltage drivers adopt low power op amps and small- sized on-chip capacitors for low power consumption and small chip area. The proposed references are designed, laid out, and fabricated in a 0.18 um n-well CMOS process and the active chip area is 250 um x 200 um. The measured results show the reference circuits have the power supply variation of 2.59 %/V and the temperature coefficient of 48 ppm/$^{\circ}C$ E.

Management of Historical Images by Time Interval and Interrelation (이력 영상의 시간 간격과 연관성에 의한 데이터 관리 기법)

  • 윤홍원
    • Journal of Korea Multimedia Society
    • /
    • v.4 no.6
    • /
    • pp.543-553
    • /
    • 2001
  • In this paper, we proposed management strategy of medical image data in order to solve the problem in traditional medical images migration method. As management strategy of medical image data we proposed EAT(Expanded Average Transaction time) data migration method and data storing method based on temporal interrelation. In EAT data migration strategy, we define the dividing criterion which distinguish entity versions to be stored in each storage and also define entity versions to be stored in each storage. We defined degree of overlap and degree of difference for any two entity versions, and integrated those values and described method which place entity versions to storage. In order to compare the number of cluster references when we change rate of temporal queries, the number of cluster references of proposed method is smaller than that of traditional method.

  • PDF

A Multistage In-flight Alignment with No Initial Attitude References for Strapdown Inertial Navigation Systems

  • Hong, WoonSeon;Park, Chan Gook
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.3
    • /
    • pp.565-573
    • /
    • 2017
  • This paper presents a multistage in-flight alignment (MIFA) method for a strapdown inertial navigation system (SDINS) suitable for moving vehicles with no initial attitude references. A SDINS mounted on a moving vehicle frequently loses attitude information for many reasons, and it makes solving navigation equations impossible because the true motion is coupled with an undefined vehicle attitude. To determine the attitude in such a situation, MIFA consists of three stages: a coarse horizontal attitude, coarse heading, and fine attitude with adaptive Kalman navigation filter (AKNF) in order. In the coarse horizontal alignment, the pitch and roll are coarsely estimated from the second order damping loop with an input of acceleration differences between the SDINS and GPS. To enhance estimation accuracy, the acceleration is smoothed by a scalar filter to reflect the true dynamics of a vehicle, and the effects of the scalar filter gains are analyzed. Then the coarse heading is determined from the GPS tracking angle and yaw increment of the SDINS. The attitude from these two stages is fed back to the initial values of the AKNF. To reduce the estimated bias errors of inertial sensors, special emphasis is given to the timing synchronization effects for the measurement of AKNF. With various real flight tests using an UH60 helicopter, it is proved that MIFA provides a dramatic position error improvement compared to the conventional gyro compass alignment.

Evaluation of Integral Seat Desk used in Universities based on KS/ISO Standard and Questionnaire Survey

  • Kee, Dohyung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.2
    • /
    • pp.125-134
    • /
    • 2014
  • Objective: The purpose of this study is to evaluate integral seat desk used in universities through comparison of real dimension values of the desk with KS/ISO standard and questionnaire survey. Background: School furniture that helps students sit comfortably for longer periods of time and allows for better concentration on learning is important. However, seat and desk have been generally designed based on the industry practice rather than user's anthropometry, and seats and desks used in universities of Korea have not been ergonomically evaluated. Method: Real 13 dimensions of the desk used in K University were measured using tape measure and inclinometer, and the dimension values were compared to the KS standard of desk and chair for lecture room (KS G 4210) and ergonomic design principles found in relevant references. Subjective appropriacies and preference for the desk were investigated based on questionnaire survey, in which 121 (male: 91, female: 30) college students participated. Results: Several dimensions for the desk and chair investigated except desk depth and width, leg room width, seat width have not met the KS standard, but all dimensions satisfied ergonomic design principles available in references. The questionnaire survey revealed that appropriacies for desk surface size, seat pan depth, seat pan cushion and backrest curvature were under middle point of 3.0, and that those for the other dimensions showed higher scores exceeding 3.0. Conclusion: The integral seat desk widely used in universities showed some design problems in terms of standards of KS G 2010 and KS G 4210, and ergonomic design principles. Compared to the general desk with separated desk and seat, subjective preference on the integral seat desk was low. Application: This would be used as a valuable guideline when designing or choosing new integral seat desk with high satisfaction of students.

Inhibition of monoamine oxidase A and B by demethoxycurcumin and bisdemethoxycurcumin

  • Baek, Seung Cheol;Choi, Bomee;Nam, Sang-Jip;Kim, Hoon
    • Journal of Applied Biological Chemistry
    • /
    • v.61 no.2
    • /
    • pp.187-190
    • /
    • 2018
  • Two curcumin derivatives, demethoxycurcumin (DMC) and bisdemethoxycurcumin (BDMC), isolated from Curcuma longa were analyzed for their inhibitory activities against two isoforms of monoamine oxidase (MAO), which is involved in the catalysis of neurotransmitting monoamines. In the study, DMC and BDMC potently inhibited human MAO-B, with $IC_{50}$ values of 2.45 and $2.59{\mu}M$, respectively, and both compounds showed effective inhibitory activities against human MAO-A, with $IC_{50}$ values of 3.24 and $3.09{\mu}M$, respectively. The inhibitory activities of the two compounds were higher than those of curcumin. The removal of the methoxy or dimethoxy groups in curcumin might increase the inhibitory activities against human MAO-A and MAO-B. The inhibited activities were recovered to almost the values of the reversible references in the dialysis experiments with DMC and BDMC. DMC and BDMC showed competitive inhibition for MAO-A and MAO-B, respectively, with $K_i$ values of 0.91 and $0.80{\mu}M$, respectively. These results suggest that the two curcumin derivatives may be useful or lead compounds in the treatment of related disorders as potent reversible MAO inhibitors.

A Study on Field Behavioral Characteristics of the Roadbed according to the Speed Increase in High-Speed Train (HEMU-430x)

  • Eum, Ki-Young;Lee, Jee-Ha;Park, Young-Kon
    • International Journal of Railway
    • /
    • v.6 no.2
    • /
    • pp.78-84
    • /
    • 2013
  • This paper is about the first experiment in Korea that was conducted on speeding increase up with rail speeds at 430km/h at high speed railway of designed 350km/h. and analysis data collected on vibration accelerations of roadbed. There are barely references on roadbed behavior measurement with rail speeds more than 350 km/h in Korea as it has never been conducted the experiment on it. So the experiments were confirmed the reliability through crosschecking the figures/values from respective sensors and measuring devices after measuring EMS and ICP types. Based on the study, values of vibration acceleration were less than 12% compared with the ones that conducted while speeding up of HEMU-430X. Also, figures of HSB for concrete bed tracks were 52% against the standard. According to the results, all the performance evaluation of vibration acceleration for roadbeds in transition zones is under the standard.

Establishment of Maintance Methods for Express railway Bridges using High Rail Monitoring Systems (상시 계측결과를 이용한 고속철도 교량의 유지관리 기준치 설정)

  • Seo, Hyeong-Lyel;Han, Sang-Chul;Ji, Ki-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.322-327
    • /
    • 2006
  • Banwol bridge with steel plate girder and Pyongtaek bridge with PSC bos girder have been operated maintenance measuring system by the Seoul-Chonan of Kyongbu express railway. By analyzing the theoretical and experimental values of design load for these two bridge, the establishment of reference maintenance for measuring items was deduced from research. Two materials, steel and concrete plates, were considered as the upper structure. Actual measurement data for the behavior under speed, structural analysis results, and the presented references were analyzed and used to set up the reference establishment. The measuring items are stress(strain), displacement, dynamic acceleration, expansion movement, and dynamic frequency. The maintenance reference was established by comparing analytical and measuring values of the five items with respect to structural state class.

  • PDF

A Study on the Yi'an (醫案) of Euibangyoochui (醫方類聚) - Focusing on the Dispersion of Yi'an for each Chapter and its References - (『의방류취(醫方類聚)』의 의안(醫案)에 대한 연구 - 각(各) 문별(門別) 분포와 인용서(引用書)를 중심으로 -)

  • Ku, Minseok;Byun, Jung-Wuck;Cha, Wung-Seok;Kim, Namil
    • The Journal of Korean Medical History
    • /
    • v.30 no.1
    • /
    • pp.23-31
    • /
    • 2017
  • Euibangyoochui (醫方類聚), the largest medical book in Korea, has medical and historical significance in that it had classified almost all East Asian medical accomplishments before Joseon Dynasty (1392-1910). Focusing on these values, this research investigates Yi'an (醫案), an East Asian tradition of describing clinical encounters and the therapies employed, in Euibangyoochui. By this investigation, this study expected to not only establish how the genre of Yi'an is employed for what purpose in Euibangyoochui, but also to shed a light on the appearance of Yi'an before Joseon Dynasty. At first, this study extracted Yi'an from Euibangyoochui (醫方類聚), as Yi'an does not have a standardized format. In total, the number of extracted Yi'ans is 1,025 with handwork results. Extracted Yi'ans are analyzed statically, in order to find dispersion of Yi'ans for each chapter and its references. Overall, there are 73 chapters of Euibangyoochui, which has a total of 93 chapters, containing Yi'an, while the chapter on gynecology contains the highest number of Yi'ans, 86. Judged from these result, the genre of Yi'an was used diversely and frequently, indicating various messages in Euibangyoochui. To categorize the usage and purpose of writing of Yi'ans in Euibangyoochui, this study considers some examples of Yi'ans and concludes that 3 types of Yi'ans are employed in Euibangyoochui in order to deliver the adequate medical message. One is result-centered Yi'an delivering a broader medical lesson, such as a taboo in treatment or a doctrine in medicine. The second is the concise-styled Yi'an presenting a short effective medical method. The third is multiple-information Yi'an that describes complex information of patients and medical theories, transmitting diverse lessons. Yi'ans in Euibangyoochui refer to 58 medical books. Books written by JangJaHwa (張子和; 1156-1228) are the most cited books, offering almost a quarter of total amount of Yi'ans in Euibangyoochui. This study is meaningful in that it provides basic information, such as numbers, applications, purpose of writing and references of Yi'an in Euibangyoochui. Moreover considering the historic values of Euibangyoochui, this information reflects, on the other hands, overall figures of Yi'an written before publication of Euibangyoochui.

Normal Physiologic Data of Korean Mongrel Dogs (한국산 잡견의 정상 생리학적 기준치)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.2 no.1
    • /
    • pp.115-132
    • /
    • 1969
  • The normal physiological values of Korean mongrel dogs were studied, comparing them with foreign references, on the basis of control physiological data measured on 110 cases out of the dogs submitted to the experiments in our department. The hemodynamic measurements varied widely between the both limits of reported normal control data, with the mean value of heart rate $140.4{\pm}26.6$/min., and both the systolic and diastolic arterial blood pressures $137.2{\pm}31.7$mmHg and $104.7{\pm}14.4$ mmHg, as well as the venous pressure of $9.11{\pm}2.18$ cm.$H_2O$. Hematologically, the number of red blood cells $4,571,000{\pm}767,000$per cu.mm., the amount of hemoglobin $11.57{\pm}3.74$ gm/dl and the hematocrit $37.3{\pm}7.2$ per cent, were equally the values a little lower than the reported normal means. However, the white blood cells were within the reported normal limits both in number, $10,384{\pm}4,877$ per cu. mm and their differential counts with slightly broader ranges of variation. The platelet count was $149,800{\pm}47,000 $per cu. mm and was also far below the normal, while the coagulation time $9.03{\pm}2.69$min. and the prothrombin time $13.17{\pm}6.52$sec were within normal limits, though a little prolonged. The serum electrolytes, Na $146.6{\pm}10.44$mEq/L.,K $4.46{\pm}0.84$mEq/L., CI $118.3{\pm}7.88$mEq/L. and Ca $11.45{\pm}5.62$mg./dl, and the blood glucose level of $94.9{\pm}31.79$mg./dl were essentially not different from the reported normal values. The serum proteins, total protein $7.15{\pm}1.41$gm/dl., albumin $4.09{\pm}0.77$gm./dl. and globulin $3.18{\pm}0.88$gm/dl. were included near the higher limits of the reported normal levels. The thymol turbidity 0.1-3.04 units were normal in 10 cases, and the cephaline flocculation was within normal range except 2 cases out of 26 dogs, showing two positive in 24 hours. And the nitrogen series, NPN $34.61{\pm}10.29$mg/dl. and BUN $12.77{\pm}6.37$mg./dl. were normal. It may be concluded that from the point of view of hereby measured physiological data compared with the foreign references, the Korean mongrel dogs have a compatible laboratory data with only the special regards to their tendency toward anemia in red blood cell series.

  • PDF