Evaluation of dimension stability according to UV-C ultrasonic cleaning of full arch artificial teeth made with DLP printer for photopolymerization (광중합용 DLP 프린터로 제작한 전악 인공치아의 UV-C 초음파 세척에 따른 체적 안정성 평가)

  • Kim, Dong-Yeon;Lee, Gwang-Young
    • Journal of Technologic Dentistry
    • /
    • v.43 no.3
    • /
    • pp.84-92
    • /
    • 2021
  • Purpose: The purpose of this study was to compare the dimension safety evaluation between a general ultrasonic cleaner and an ultrasonic cleaner equipped with UV-C (ultraviolet-C). Methods: An edentulous model was prepared. A denture base and an occlusal rim were fabricated, and scanning was performed. After scanning, a denture base and full arch artificial teeth were designed. The full arch artificial teeth were printed using a three-dimensional printer (n=10). The residual resin was washed with alcohol and then scanned (reference data). The printed specimens were classified and cleaned using a general ultrasonic cleaner (GU group) and an ultrasonic cleaner equipped with UV-C (UC group). After each washing, a rescan was performed (scan data). Reference data and scan data were superimposed using overlapping software. Data were statistically analyzed using the Mann-Whitney test (α=0.05). Results: In the deviation values of full arch artificial teeth, the GU group showed a high deviation of 18.02 ㎛ and the UC group showed a low deviation of 15.02 ㎛. The two groups demonstrated a statistically significant difference (p<0.05). Conclusion: Full arch artificial teeth prepared using photopolymerized resin were deformed according to the temperature of water generated in the ultrasonic cleaner. It is judged that there is no deformation according to the UV-C ultrasonic cleaner.

Selection of mAs with Using Table Strap in Computed Tomography Scan (전산화단층촬영 시 환자 고정 밴드를 이용한 선량의 선택)

  • Lee, Young-Hyen;An, Hyeong-Theck
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.63-69
    • /
    • 2011
  • Table strapis patient fixture for securing the patient movements and falls. if it designed to measure the abdominal circumference and used as an indicator of dose selection at CT scan. it will prevent the overexposure of dose without degradation of image quality and efficiently manage dose of each type of body to technician to deal with CT. First, in order to compare the dose used in CT image and qualitative characteristics. reference image is obtained by examining the abdominal phantom in same conditions with the hospital 120 kVp, 200 mAs, D-Dom (Dynamic Dose Of Modulation). SNR, PSNR, RMSE, MAE, CTDIvol of CT images are compared with reference image. for comparing with reference image, the image that Umbilicus level image of Abdomen CT is stored in the PACS were used. For comparison, the top 12 o'clock portion of the air drawn from the same ROI was measured. CTDIvol, mAs, etc. In order to analyze the characteristics of the image, by measuring the length of the umbilicus circumference, pattern of the dose was analyzed. by using the analyzed perimeter and dose information, To be identified visually, fixed band that scale marked were produced. Use them, If the length of circumference of less than 60 cm 100 mAs, Case of 61~80 cm 120 mAs, Case of 80~100 cm 150 mAs, more than 100 cm 200 mAs, dose selection based on the perimeter, the image was applied. by compare analyzed with the Reference Image, image quality was assessed. by compare with existing tests that equally 200 mAs applied, How much was confirmed that the dose reduction. 1. Depending on the Abdominal circumference, the average PSNR(dB) of the image that differently dose applied was 45.794. 2. Comparing with existing test. the dose of scan that adjusted the mAs depending on the circumference was decreased about 40%. SNR and PSNR of the image that obtained by adjusting the standard mAs based on dose modulation were not much different. Therefore, By choosing a low mAs. dose reduction can be obtained. and the dose selection method that measured Abdominal circumference using a fixed band can protect the overexposure and uniformly apply dose of each type of body to technician to deal with CT.

  • PDF

The Verification of Accuracy of 3D Body Scan Data - Focused on the Cyberware WB4 Whole Body Scanner - (3차원 인체 스캔 데이터의 정확도 검증에 관한 연구 - Cyberware의 WB4 스캐너를 중심으로 -)

  • Park, Sun-Mi;Nam, Yun-Ja
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.14 no.1
    • /
    • pp.81-96
    • /
    • 2012
  • The purpose of this study is to provide fundamental information for standardization of 3D body measurement. This research analyzes errors occurring in the process of extracting body size from 3D body scan data. First, as a result of analyzing basic state of the 3D body scanner's calibration, the point number of each section was almost the same, while the right and left as well as the front and back coordinates of the center of gravity are not, showing unstable data. Nevertheless, the latter does not influence on the size of cylinder such as width and circumference. Next, we analyzed point coordinates variations of scan data on a mannequin nude by life casting. The result was great deflection in case of complicated or horizontal sections including the reference point beyond proper distance from centers of four cameras. In case of the mannequin's size, accuracy proves comparatively high in that measurement errors in height, width, depth, and length dimension occurred all within allowable errors, only except chest depth, while there were a lot of measurement errors in a circumference dimension. Secondly, analysis of accuracy of automatic extraction identification program algorithm presented that a semi-automatic measurement program is better than an automatic measurement program. While both of them ate very acute in parts related to crotch, they are not in armpit related parts. Therefore, in extracting of human body size from 3D scan data, what really matters seems to parts related to armpits.

  • PDF

Calibration Method of the Tomographic Gamma Scan Techniques Available for Accurately Characterizing 137Cs from 110mAg Interference (110mAg 간섭으로부터 137Cs 정량평가를 위한 드럼핵종분석 교정기술)

  • Jeong, Sung Yeop
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.1
    • /
    • pp.57-61
    • /
    • 2016
  • The Tomographic Gamma Scan (TGS) technique partitions radioactive waste drums into $10{\times}10{\times}16$ voxels and assays both the density and concentration of radioactivity for each voxel thus providing for improved accuracy, when compared to the traditional Non-Destructive Assay(NDA) techniques. It could decrease the degree of precision measurement since there is a trade-off between spatial resolution and precision. This latter drawback is compensated by expanding the Region of Interest (ROI) that differentiates the full energy peaks, which, in turn, results in an optimized degree of precision. The enlarged ROI, however, increases the probability of interference among those nuclides that emit energies in the adjacent spectrum. This study has identified the cause of such interference for the reference nuclide of the TGS technique, $^{137}Cs$ (661.66 keV, half-life 30.5 years), to be $^{110m}Ag$ (657.75 keV, half-life 249.76 days). A new calibration method of determining the optimized ROI was developed, and its effectiveness in accurately characterizing $^{137}Cs$ and eliminating the interference was further ascertained.

A Study on the PET/CT Fusion Imaging (PET/CT 결합영상진단 검사에 관한 연구)

  • Kim, Jong Gyu
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.193-198
    • /
    • 2004
  • PET/CT combines the functional information from a positron emission tomography (PET) exam with the anatomical information from a computed tomography (CT) exam into one single exam. A CT scan uses a combination of x-rays and computers to give the radiologist a non-invasive way to see inside your body. One advantage of CT is its ability to rapidly acquire two-dimensional pictures of your anatomy. Using a computer these 2-D images can be presented in 3-D for in-depth clinical evaluation. A PET scan detects changes in the cellular function - how your cells are utilizing nutrients like sugar and oxygen. Since these functional changes take place before physical changes occur, PET can provide information that enables your physician to make an early diagnosis. The PET exam pinpoints metabolic activity in cells and the CT exam provides an anatomical reference. When these two scans are fused together, your physician can view metabolic changes in the proper anatomical context of your body. PET/CT offers significant advantages including more accurate localization of functional abnormalities, and the distinction of pathological from normal physiological uptake, and improvements in monitoring treatment. A PET/CT scan allows physicians to measure the body's abnormal molecular cell activity to detect cancer (such as breast cancer, lung cancer, colorectal cancer, lymphoma, melanoma and other skin cancers), brain disorders (such as Alzheimer's disease, Parkinson's disease, and epilepsy), and heart disease (such as coronary artery disease).

  • PDF

Comparison of Lens Dose in accordance with Bismuth shielding and Patient position in Brain perfusion CT (Brain Perfusion CT에서 Bismuth 차폐와 환자의 자세 변화에 따른 수정체 선량 비교 연구)

  • Gang, Eun Bo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.47-52
    • /
    • 2018
  • Brain perfusion CT scanning is often employed usefully in clinical conditions as it accurately and promptly provides information about the perfusion state of patients having acute ischemic stroke with a lot of time constraints and allows them to receive proper treatment. Despite those strengths of it, it also has a serious weakness that Lens may be exposed to a lot of dose of radiation in it. In this study, as a way to reduce the dose of radiation to Lens in brain perfusion CT scanning, this researcher conducted an experiment with Bismuth shielding and change of patients' position. TLD (TLD-100) was placed on both lens using the phantom (PBU-50), and then, in total 4 positions, parallel to IOML, parallel to IOML (Bismuth shielding), parallel to SOML, and parallel to SOML (Bismuth shielding), brain perfusion scanning was done 5 times for each position, and dose to Lens were measured. Also, to examine how the picture quality changed in different positions, 4 areas of interest were designated in 4 spots, and then, CT number and noise changes were measured and compared. According to the results of conducting one-way ANOVA on the doses measured, as the significance probability was found to be 0.000, so there was difference found in the doses of radiation to crystalline lenses. According to the results of Duncan's post-hoc test, with the scanning of being parallel to IOML as the reference, the reduction of 89.16% and 89.66% was observed in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding) respectively, so the doses to Lens reduced significantly. Next, in the scanning of being parallel to IOML (Bismuth shielding), the reduction of 37.12% was found. According to the results, reduction in the doses of radiation was found the most significantly both in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding). With the limit of the equivalent dose to Lens as the reference, this researcher conducted comparison with the dose to occupational exposure and dose to Public exposure in the scanning of being parallel to IOML and found 39.47% and 394.73% respectively; however in the scanning of being parallel to SOML (Bismuth shielding), considerable reduction was found as 4.08% and 40.8% respectively. According to the results of evaluation on picture quality, every image was found to meet the evaluative standards of phantom scanning in terms of the measurement of CT numbers and noise. In conclusion, it would be the most useful way to reduce the dose of radiation to Lens to use shields in brain perfusion CT scanning and adjust patients' position so that their lens will not be in the field of radiation.

Comparison of the accuracy of intraoral scanner by three-dimensional analysis in single and 3-unit bridge abutment model: In vitro study (단일 수복물과 3본 고정성 수복물 지대치 모델에서 삼차원 분석을 통한 구강 스캐너의 정확도 비교)

  • Huang, Mei-Yang;Son, Keunbada;Lee, Wan-Sun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.102-109
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate the accuracy of three types of intraoral scanners and the accuracy of the single abutment and bridge abutment model. Materials and methods: In this study, a single abutment, and a bridge abutment with missing first molar was fabricated and set as the reference model. The reference model was scanned with an industrial three-dimensional scanner and set as reference scan data. The reference model was scanned five times using the three intraoral scanners (CS3600, CS3500, and EZIS PO). This was set as the evaluation scan data. In the three-dimensional analysis (Geomagic control X), the divided abutment region was selected and analyzed to verify the scan accuracy of the abutment. Statistical analysis was performed using SPSS software (${\alpha}=.05$). The accuracy of intraoral scanners was compared using the Kruskal-Wallis test and post-test was performed using the Pairwise test. The accuracy difference between the single abutment model and the bridge abutment model was analyzed by the Mann-Whitney U test. Results: The accuracy according to the intraoral scanner was significantly different (P < .05). The trueness of the single abutment model and the bridge abutment model showed a statistically significant difference and showed better trueness in the single abutment (P < .05). There was no significant difference in the precision (P = .616). Conclusion: As a result of comparing the accuracy of single and bridge abutments, the error of abutment scan increased with increasing scan area, and the accuracy of bridge abutment model was clinically acceptable in three types of intraoral scanners.

A Survey on the Radiation Exposure Doses Reduction Plan through Dose Index Analysis in the Pediatric Brain Computed Tomography (소아 두부 컴퓨터단층촬영검사에서 선량지표 분석을 통한 방사선 피폭선량 감소 방안에 대한 연구)

  • Kim, Hyeon-Jin;Lee, Hyo-Yeong;Im, In-Chul;Yu, Yun-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.161-169
    • /
    • 2016
  • In this study, the proposal to seek ways to reduce the amount of radiation is drawn by comparing and analyzing CT Dose Index(CTDI) on the pediatric head CT which was performed at the busan regional hospitals, to the national diagnostic reference levels. As a result, it was appeared to exceed the amount of the dose recommendation in order of hospital, general hospital and senior general hospital in the hospital-specific classification and from 2 to 5 year, from 1 month to 1 year and from 6 to 10 year in the age-specific classification. In addition, the amount of the dose recommendation was exceed in order of helical, axial and volume in the scan-specific classification. As the results of the scan range reset to match the diagnostic reference level, the dose reduction showed 11.68%, 15.79% and 20.66% in senior general hospital, general hospital and hospital respectively. In the results of analysing patient average scan ranges which does not deviate from the guideline of patient dose recommendation, there was age of 1 month to 1 year, 2 to 5 year and 6 to 10 year of $03.2{\pm}11.8mm$, $110.5{\pm}14.5mm$, and $117.8{\pm}17.2mm$ respectively.

Marginal and internal discrepancy of 3-unit fixed dental prostheses fabricated by subtractive and additive manufacturing (절삭 및 적층 가공법으로 제작된 3본 고정성 국소의치의 변연 및 내면 적합도에 관한 연구)

  • Choi, Jae-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.1
    • /
    • pp.7-13
    • /
    • 2020
  • Purpose: This study was to evaluate marginal and internal discrepancy of 3-unit fixed dental prostheses (FDP) fabricated by subtractive manufacturing and additive manufacturing. Materials and methods: 3-unit bridge abutments without the maxillary left second premolar were prepared (reference model) and the reference model scan data was obtained using an intraoral scanner. 3-unit fixed dental prostheses were fabricated in the following three ways: Milled 3-unit FDP (MIL), digital light processing (DLP) 3D printed 3-unit FDP (D3P), stereolithography apparatus (SLA) 3D printed 3-unit FDP (S3P). To evaluate the marginal/internal discrepancy and precision of the prosthesis, scan data were superimposed by the triple-scan protocol and the combinations calculator, respectively. Quantitative and qualitative analysis was performed using root mean square (RMS) value and color difference map in 3D analysis program (Geomagic control X). Statistical analysis was performed using the Kruskal-Wallis test (α=.05), MannWhitney U test and Bonferroni correction (α=.05/3=.017). Results: The marginal discrepancy of S3P group was superior to MIL and D3P groups, and MIL and D3P groups were similar. The D3P and S3P groups showed better internal discrepancy than the MIL group, and there was no significant difference between the D3P and S3P groups. The precision was excellent in the order of MIL, S3P, and D3P groups. Conclusion: Within the limitation of this study, the 3-unit fixed dental prostheses fabricated by additive manufacturing showed better marginal and internal discrepancy than the those of fabricated by subtractive manufacturing, but the precision was poor.

Analysis and Evaluation of Computed Tomography Dose Index (CTDI) of Pediatric Brain by Hospital Size (병원규모별 소아 두부 CT 검사 선량지표 분석 평가)

  • Kim, Hyeonjin;Lee, Hyoyeong;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.503-510
    • /
    • 2016
  • Even though children are exposed to the same amount of radiation, their effective dose amount is higher than those of adults. Therefore, it is very important to reduce the amount of unnecessary radiation exposure because children have a higher radiosensitivity and a smaller body size than adults. In this study, the proposal to seek ways to reduce the amount of radiation is drawn by comparing and analyzing CT Dose Index(CTDI) on the pediatric head CT which was performed at the Busan regional hospitals, to the national diagnostic reference levels. For this, the pediatric head CT scan was conducted among the CT equipments that were installed in downtown Busan. From 2,043 children 10 years old or less who were referred to the pediatric head CT scan, targeting the 28 CT equipments in the 24 hospitals that transmit dose reports to PACS, were examined retrospectively. As a result, the average value of CTDIvol, computed tomography dose index (CTDI) of infant brain, across the hospital, was 31.18 mGy, with DLP of $444.73mGy{\cdot}cm$, which exceeded the diagnostic reference level. The lower the age, the more management is needed for radiation. However, the reality is that the CT examinations are being conducted with a dose that exceeds the reference level as the age of the aged is exceeded. For this purpose, the study seeks to determine the degree of doses of doses outside the diagnostic reference level and analyze the cause of the excess dose and devise measures to reduce the dose reduction.